| 1 | N.S. Item |
| 2 | Supply erection testing of reputed make LED light 100watt complete in all respect |
| 3 | Provision for 16 sqm Wire Electric wiring to Electric Motor complete in all respect.(16 Sqm) |
| 4 | Provision for 10 sqm Electric wiring to Electric Motor complete in all respect. (10 Sqm) |
| 5 | Providing and installation new household tap connection etc. complete in all respect (AMRUT-2.0). (Providing and installation new household tap connections etc. complete in all respect (AMRUT-2.0). including wate rmeter (make caranity,desemash,NBSON. etc) |
| 6 | Supply errection, testing and commissioning of ATS (Auto Transformer Starter) panel make Siemens, L and T, BCH with copper bus bas solid connection of suitable rating (with specification, general conditions and accessories consisting 1 no. incoming LT MCCB 250 Amp. with IDMT relay TP one set of metering (Amp. Meter with CT volt meter with CT with control fuse 4 nos.) Each starter state above should contain following items complete for 100 BHP pumping machinery. (a) MCCB Amp. TP 1 no. (b) Contactor 185 Amp- 3 no. (C ) Over load relay (CT operated 100-150 Amp.) 1 no. (d) Timer Electronic 0.60 second- 1 no. (e) Single phase preventer - 415 voltage AC-1 (f) Motor protection reply - 0.5-0.60 A 220 V AC- 1 no. (g) Push button - 1 no (h) Amp meter 0-200 Amp. 1 no. (i) CTS 200/5 Amp - 3 no. (j) Amp. Selector switch- 1 no. (k) Control fuse - 3 no. (l) Temp sensor relay, Moisture sensor relay.(for old water works = 2 nos. for b/stn yog nagar = 4 nos. for b/stn ratiachungi = 2 nos. total = 8 nos.) |
| 7 | Supply errection, testing and commissioning of ATS (Auto Transformer Starter) panel make Siemens, L and T, BCH with copper bus bas solid connection of suitable rating (with specification, general conditions and accessories consisting 1 no. incoming LT MCCB 300 Amp. with IDMT relay TP one set of metering (Amp. Meter with CT volt meter with CT with control fuse 4 nos.) Each starter state above should contain following items complete for 200 BHP pumping machinery. (a) MCCB Amp. TP 1 no. (b) Contactor 185 Amp- 3 no. (C ) Over load relay (CT operated 100-150 Amp.) 1 no. (d) Timer Electronic 0.60 second- 1 no. (e) Single phase preventer - 415 voltage AC-1(f) Motor protection reply - 0.5-0.60 A 220 V AC- 1 no. (g) Push button - 1 no (h) Amp meter 0-200 Amp. 1 no. (i) CTS 200/5 Amp - 3 no. (j) Amp. Selector switch- 1 no. (k) Control fuse - 3 no. (l) Temp sensor relay, Moisture sensor relay. (for old water works ) |
| 8 | Supply errection, testing and commissioning of ATS (Auto Transformer Starter) panel make Siemens, L and T, BCH with copper bus bas solid connection of suitable rating (with specification, general conditions and accessories consisting 1 no. incoming LT MCCB 100 Amp. with IDMT relay TP one set of metering (Amp. Meter with CT volt meter with CT with control fuse 4 nos.) Each starter state above should contain following items complete for 40 BHP pumping machinery. (a) MCCB Amp. TP 1 no. (b) Contactor 185 Amp- 3 no.(C ) Over load relay (CT operated 100-150 Amp.) 1 no.(d) Timer Electronic 0.60 second- 1 no.(e) Single phase preventer - 415 voltage AC-1(f) Motor protection reply - 0.5-0.60 A 220 V AC- 1 no. (g) Push button - 1 no(h) Amp meter 0-200 Amp. 1 no.(i) CTS 200/5 Amp - 3 no.(j) Amp. Selector switch- 1 no.(k)Control fuse - 3 no. (l) Temp sensor relay, Moisture sensor relay. (For old water works = 2 nos. For Kherati khera b/Stn = 2 nos) |
| 9 | Supply errection, testing and commissioning of ATS (Auto Transformer Starter) panel make Siemens, L and T, BCH with copper bus bas solid connection of suitable rating (with specification, general conditions and accessories consisting 1 no. incoming LT MCCB 250 Amp. with IDMT relay TP one set of metering (Amp. Meter with CT volt meter with CT with control fuse 4 nos.) Each starter state above should contain following items complete for 120 BHP pumping machinery. (a) MCCB Amp. TP 1 no. (b) Contactor 185 Amp- 3 no. (C ) Over load relay (CT operated 100-150 Amp.) 1 no. (d) Timer Electronic 0.60 second- 1 no. (e) Single phase preventer - 415 voltage AC-1 (f) Motor protection reply - 0.5-0.60 A 220 V AC- 1 no. (g) Push button - 1 no (h) Amp meter 0-200 Amp. 1 no. (i) CTS 200/5 Amp - 3 no. (j) Amp. Selector switch- 1 no. (k) Control fuse - 3 no. (l) Temp sensor relay, Moisture sensor relay.(or old waterworks (Bhatu Road) |
| 10 | Supply errection, testing and commissioning of ATS (Auto Transformer Starter) panel make Siemens, L and T, BCH with copper bus bas solid connection of suitable rating (with specification, general conditions and accessories consisting 1 no. incoming LT MCCB 100 Amp. with IDMT relay TP one set of metering (Amp. Meter with CT volt meter with CT with control fuse 4 nos.) Each starter state above should contain following items complete for 10000 LPM with 12 Mtr. Head pumping machinery. (a) MCCB Amp. TP 1 no. (b) Contactor 185 Amp- 3 no. (C ) Over load relay (CT operated 100-150 Amp.) 1 no. (d) Timer Electronic 0.60 second- 1 no.(e) Single phase preventer - 415 voltage AC-1(f) Motor protection reply - 0.5-0.60 A 220 V AC- 1 no.(g) Push button - 1 no(h) Amp meter 0-200 Amp. 1 no.(i) CTS 200/5 Amp - 3 no.(j) Amp. Selector switch- 1 no.(k) Control fuse - 3 no.(l) Temp sensor relay, Moisture sensor relay. |
| 11 | Supply errection, testing and commissioning of ATS (Auto Transformer Starter) panel make Siemens, L and T, BCH with copper bus bas solid connection of suitable rating (with specification, general conditions and accessories consisting 1 no. incoming LT MCCB 250 Amp. with IDMT relay TP one set of metering (Amp. Meter with CT volt meter with CT with control fuse 4 nos.) Each starter state above should contain following items complete for 8340 LPM 30 Mtr. Head pumping machinery.(a) MCCB Amp. TP 1 no.(b) Contactor 185 Amp- 3 no.(C ) Over load relay (CT operated 100-150 Amp.) 1 no. (d) Timer Electronic 0.60 second- 1 no.(e) Single phase preventer - 415 voltage AC-1(f) Motor protection reply - 0.5-0.60 A 220 V AC- 1 no.(g) Push button - 1 no(h) Amp meter 0-200 Amp. 1 no.(i) CTS 200/5 Amp - 3 no.(j) Amp. Selector switch- 1 no.(k) Control fuse - 3 no.(l) Temp sensor relay, Moisture sensor relay. |
| 12 | Supply errection, testing and commissioning of ATS (Auto Transformer Starter) panel make Siemens, L and T, BCH with copper bus bas solid connection of suitable rating (with specification, general conditions and accessories consisting 1 no. incoming LT MCCB 100 Amp. with IDMT relay TP one set of metering (Amp. Meter with CT volt meter with CT with control fuse 4 nos.) Each starter state above should contain following items complete for 1700 lpm 45 mtr head pumping machinery. (a) MCCB Amp. TP 1 no. (b) Contactor 185 Amp- 3 no. (C ) Over load relay (CT operated 100-150 Amp.) 1 no. (d) Timer Electronic 0.60 second- 1 no. (e) Single phase preventer - 415 voltage AC-1 (f) Motor protection reply - 0.5-0.60 A 220 V AC- 1 no. (g) Push button - 1 no (h) Amp meter 0-200 Amp. 1 no. (i) CTS 200/5 Amp - 3 no. (j) Amp. Selector switch- 1 no. (k) Control fuse - 3 no. (l) Temp sensor relay, Moisture sensor relay. (at boosting station) |
| 13 | Providing and Installing of Horizental Centrifugal Pumping set of 10000 LPM with 12 Mtr. Head electric Motor Complete in all respect. |
| 14 | Cubical type APFC panel made of Techno Modular construction with CRCA sheet steel suitable for 415 V, 3 phase, 4 wire 50 Hz AC supply system. Having required front surface area, fabricated in Fully compartmentalized design from CRCA sheet steel of 1.5 / 2mm thick for framework and covers, 3mm thick for gland plates i/c cleaning and finishing complete with 10 tank spray based tricationic phosphating treatment process for powder coating in approved shade, PU Foam Gasket without manual pasting, joint less (temperature withstand capacity -40degC toplus120degC) for maintain IP protection. Company made panel. 275 KVAR APFC PANEL (At main water works and AT OLD WATER WORKS AND B/STN BHATTU ROAD) |
| 15 | Cubical type APFC panel made of Techno Modular construction with CRCA sheet steel suitable for 415 V, 3 phase, 4 wire 50 Hz AC supply system. Having required front surface area, fabricated in Fully compartmentalized design from CRCA sheet steel of 1.5 / 2mm thick for framework and covers, 3mm thick for gland plates i/c cleaning and finishing complete with 10 tank spray based tricationic phosphating treatment process for powder coating in approved shade, PU Foam Gasket without manual pasting, joint less (temperature withstand capacity -40degC toplus120degC) for maintain IP protection. Company made panel. 150KVAR APFC PANEL AT YOG NAGAR |
| 16 | Cubical type APFC panel made of Techno Modular construction with CRCA sheet steel suitable for 415 V, 3 phase, 4 wire 50 Hz AC supply system. Having required front surface area, fabricated in Fully compartmentalized design from CRCA sheet steel of 1.5 / 2mm thick for framework and covers, 3mm thick for gland plates i/c cleaning and finishing complete with 10 tank spray based tricationic phosphating treatment process for powder coating in approved shade, PU Foam Gasket without manual pasting, joint less (temperature withstand capacity -40degC toplus120degC) for maintain IP protection. Company made panel. 70KVAR APFC PANEL (AT RATIA CHUNGI) |
| 17 | Less credit for Old panel boardforRaw Water Pump Suitable and Clear Water Pump for Complete in all respect. (3 nos. for clear water - 75 bhp and 3 nos. for raw water - 30 bhp) |
| 18 | Less credit of 100 BHP old starter with accessories complete in all respects. (old waterworks, 2 nos yog nagar b/s, 4 nos. Ratia chungi b/s - 2 nos.) |
| 19 | Less credit of 120 BHP old starter with accessories complete in all respects. (old waterworks) |
| 20 | Less credit of 200 BHP old starter with accessories complete in all respects. (Old water works - 2 nos. ) |
| 21 | Less credit of 40 BHP old starter with accessories complete in all respects. (Old water works - 2 nos. kharti road - 2 nos.) |
| 22 | Less credit of old Machinary 7260 LPM x 12 Mtr. Head (Raw old water machinery) |
| 23 | Less Credit for NRV, S/V (NRV - 3Nos. S/V - 6 Nos.) |