Assam Rifles-AR has published Tender For Provision Of Borewell Alongwith Connected Water Supply Line In Cob Senua And Niausa Of Under 32 Assam Rifles (Now 40 Assam Rifles).. Submission Date for this Tender is 06-02-2024. Water Supply Project Tenders in Longding Arunachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Part -ICOB SenuaM/L for carring out Geo physical survey for ground water exploration by electrical resistivity technique at different location spread at suitable intervals to find out delineation of litho logical features of area thickness of layers and most favorable site for ground water strate based on geo-logical paramiteres and deposition of sub surface formation aquifer upto the depthof 220 mtrs andsubmit adetailed report in regards (at least 02 spots in each locations). |
2 | Boring/Drilling bore well of required dia for casing/strainer pipe by suitable method prescribed in IS : 2800 (Part-I), including collecting samples from different strata chest/bore leg, including hire & running charges of all equipments, tool plants machineries required fo the job, all completed as per direction of Engr-In-charge, upto 90 mtr depth below ground level,(All Type of Soil) of 300 mm Dia. |
3 | Ditto as per items No 2 above but rocky strata including boulders. |
4 | Boring/Drilling bore well of required dia for casing/strainer pipe by suitable method prescribed in IS : 2800 (Part-I), including collecting samples from different strata chest/bore leg, including hire & running charges of all equipments, tool plants machineries required fo the job, all completed as per direction of Engr-In-charge, beyond 90 mtr depth below ground level,(All Type of Soil) of 300 mm Dia. |
5 | Gravel Packing of in tube well construction in accordance with IS4097 including providing Gravel/fine/medium coarse in required grading and sizes as per actual requirement all completed as per direction of Engr-In-charge. |
6 | Supply, assembling lowering and fixing in vertical position in bore well, ERW(Electric Resistance Welded) FE410 plain slotted having slot size 1.6/3.2mm mild steel threaded and socketed plain bevel ended pipe (type-A) of required dia confirming to IS8110 of reputed and approved make, having wall thickness not less than 5.40 mmincluded painted outside surface with two coats of anticorrosive bitumenstic paint of approved brand and manufacture, included hire & labour charges, fittings and accessories all completed for all depths, as per direction of Engr-In-Charge of 200 mm Nominal size dia. having minimum wall thickness 5.40 mm (Make : Tata/Jindal/Any ISI Marks) |
7 | Development of tubewell in accordance with IS 2800 (Part-I) and IS 11189, to establish maximum rate usable water yield without sand content (beyond the permissible limit) with required capacity aire compressor, running the compressor required time til well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc by draw down method, collecting water samples getting tested in approved laboratory, i.e dishing faction of tube well, all complete including hire and lobour charges Air compressor, tools & accessories etc, all as per requirement and direction of Engr-In-Charge. |
8 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing casing pipe removable as per requirement, all completed OD 200 mm dia |
9 | Providing and fixing MS clamp of required dia to the top of casing / housing pipe of tube well as per IS 2800 (part-I) including necessary bolts and nuts of required size complete |
10 | Providing and fixing bail plug/bottom plug of 200 mm dia to the bottom of pipe assembly of tube well as per IS 2800 (Part-I) |
11 | Supply, Installation, testing and commissioning of submersible pumping set of capacity 7.5 HP completed of AC 3 Phase, 415 Volts complete slection of suitable delivery head will be ascertained after finalization of yield including delivery pipe. One year warranty, maint will be provided by contractor to the Deptt. (Make : KSB/Kirloskar) |
12 | Supply, Installation, testing and commissioning of starter unit (FASD) three phase, 415 Volt starter unit suitable for operating 3 phase submersible motor pump of capacity 7.5 HP (Make-L&T or equivlent make) all as specified and directed |
13 | Providing and fixing PN-10 Pipe, 50 mm OD(SDR-11) 3 LayerPP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP-R plain & brass threaded Propylene Random fittings, included trenching, refilling & testing of joints complete as per direction of Engr-In Charge |
14 | All as per Item No-13 above but of dia 63 mm |
15 | Supply and fixing Submersible copper cable 3 core 6 Sqmm size weather proof including necessary connected items as per site requirment will be provide and as per direction of Engr-In-Charge (Make : Havells/Finolex/Anchor) |
16 | Supply & Fixing PVC Water Tank of Capacity 3000 Ltrs of Approved make (Sintex) including inlet/outlet arrangement with float valve and gate valve etc on PCC base as directed by Engr-In-Charge at work site (3000 Ltrs x 04 = 12000 Ltrs) (Make : Sintex/polycon) |
17 | Part -IICOB NiausaM/L for carring out Geo physical survey for ground water exploration by electrical resistivity technique at different location spread at suitable intervals to find out delineation of litho logical features of area thickness of layers and most favorable site for ground water strate based on geo-logical paramiteres and deposition of sub surface formation aquifer upto the depthof 220 mtrs andsubmit adetailed report in regards (at least 02 spots in each locations). |
18 | Boring/Drilling bore well of required dia for casing/strainer pipe by suitable method prescribed in IS : 2800 (Part-I), including collecting samples from different strata chest/bore leg, including hire & running charges of all equipments, tool plants machineries required fo the job, all completed as per direction of Engr-In-charge, upto 90 mtr depth below ground level,(All Type of Soil) of 300 mm Dia. |
19 | Ditto as per items No 2 above but rocky strata including boulders. |
20 | Boring/Drilling bore well of required dia for casing/strainer pipe by suitable method prescribed in IS : 2800 (Part-I), including collecting samples from different strata chest/bore leg, including hire & running charges of all equipments, tool plants machineries required fo the job, all completed as per direction of Engr-In-charge, beyond 90 mtr depth below ground level,(All Type of Soil) of 300 mm Dia. |
21 | Gravel Packing of in tube well construction in accordance with IS4097 including providing Gravel/fine/medium coarse in required grading and sizes as per actual requirement all completed as per direction of Engr-In-charge. |
22 | Supply, assembling lowering and fixing in vertical position in bore well, ERW(Electric Resistance Welded) FE410 plain slotted having slot size 1.6/3.2mm mild steel threaded and socketed plain bevel ended pipe (type-A) of required dia confirming to IS8110 of reputed and approved make, having wall thickness not less than 5.40 mmincluded painted outside surface with two coats of anticorrosive bitumenstic paint of approved brand and manufacture, included hire & labour charges, fittings and accessories all completed for all depths, as per direction of Engr-In-Charge of 200 mm Nominal size dia. having minimum wall thickness 5.40 mm (Make : Tata/Jindal/Any ISI Marks) |
23 | Development of tubewell in accordance with IS 2800 (Part-I) and IS 11189, to establish maximum rate usable water yield without sand content (beyond the permissible limit) with required capacity aire compressor, running the compressor required time til well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc by draw down method, collecting water samples getting tested in approved laboratory, i.e dishing faction of tube well, all complete including hire and lobour charges Air compressor, tools & accessories etc, all as per requirement and direction of Engr-In-Charge. |
24 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing casing pipe removable as per requirement, all completed OD 200 mm dia |
25 | Providing and fixing MS clamp of required dia to the top of casing / housing pipe of tube well as per IS 2800 (part-I) including necessary bolts and nuts of required size complete |
26 | Providing and fixing bail plug/bottom plug of 200 mm dia to the bottom of pipe assembly of tube well as per IS 2800 (Part-I) |
27 | Supply, Installation, testing and commissioning of submersible pumping set of capacity 7.5 HP completed of AC 3 Phase, 415 Volts complete slection of suitable delivery head will be ascertained after finalization of yield including delivery pipe. One year warranty, maint will be provided by contractor to the Deptt. (Make : KSB/Kirloskar) |
28 | Supply, Installation, testing and commissioning of starter unit (FASD) three phase, 415 Volt starter unit suitable for operating 3 phase submersible motor pump of capacity 7.5 HP (Make-L&T or equivlent make) all as specified and directed |
29 | Providing and fixing PN-10 Pipe, 50 mm OD(SDR-11) 3 LayerPP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP-R plain & brass threaded Propylene Random fittings, included trenching, refilling & testing of joints complete as per direction of Engr-In Charge |
30 | All as per Item No-13 above but of dia 63 mm |
31 | Supply and fixing Submersible copper cable 3 core 6 Sqmm size weather proof including necessary connected items as per site requirment will be provide and as per direction of Engr-In-Charge (Make : Havells/Finolex/Anchor) |
32 | Supply & Fixing PVC Water Tank of Capacity 3000 Ltrs of Approved make (Sintex) including inlet/outlet arrangement with float valve and gate valve etc on PCC base as directed by Engr-In-Charge at work site (3000 Ltrs x 04 = 12000 Ltrs) (Make : Sintex/polycon) |