Tender For Provision Of 3 X 10 Lakh Ltr Capacity Rcc Reservoir Water Tank With Connected Items At 28 Ar Tuensang, tuensang-Nagaland

Assam Rifles-AR has published Tender For Provision Of 3 X 10 Lakh Ltr Capacity Rcc Reservoir Water Tank With Connected Items At 28 Ar Tuensang. Submission Date for this Tender is 02-02-2024. Water Tank Tenders in tuensang Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

41641703
Tender For Provision Of 3 X 10 Lakh Ltr Capacity Rcc Reservoir Water Tank With Connected Items At 28 Ar Tuensang
Open Tender
Indian
Nagaland
tuensang
02-02-2024

Tender Details

Provision Of 3 X 10 Lakh Ltr Capacity Rcc Reservoir Water Tank With Connected Items At 28 Ar Tuensang

Key Value

Document Fees
INR 1500 /-
EMD
INR 448800.0 /-
Tender Value
INR 1.49 Crore /-

BOQ Items

Name of Work: PPROVISION OF 3 X 10 LAKH LTR CAPACITY RCC RESERVOIR WATER TANK WITH CONNECTED ITEMS AT 28 AR TUENSANG
Sl. No. Item Description
1Earth work in excavation by mechanical means(Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.L=20.00+1.50x2=23.00 B=15.00+1.50x2+18.00
2Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks. L= 20.00+0.35x2+0.15x2=21 B=15.00+0.35x2+0.15x2=16.00
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth levelL=20.00+0.35x2+20.70 mtrB=15.00+0.35x2=15.70 mtr
4ProviIding and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to loor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) cum 10185.05
6Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
7Ditto but to side of walls including attached pilasters, buttress, plinth and string cources etc L=(20+15)x2=70.00, Ht = 3.69 mtr
8Ditto but to sides softs of beams L=20.50 sides of beams L=26.5x0.25=18.50
9Ditto but to sides softs of beams (0.25+0.20)ht=1.50-0.20=1.30
10Providing and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:
1112 mm cement plaster finished with a floating coat of neat cement of mix :13.7.1 1:3 (1 cement: 3 fine sand)
12Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
13Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks
141:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
15Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
1615 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand) sqm 339.70
17Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat ofapproved steel primer
18Providing and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) 150 mm dia C.I. Double Flanged Pipe metre
19Providing and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) : 18.71.1 100 mm dia C.I. Double Flanged Pipe metre
20Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc
21Ditto but 100 mm
22Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge. All kinds of soil
23Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
241:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
25Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources)
26Centering and shuttering including strutting, propping etc. and removalof form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
27Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. 5.22.1 Mild steel and Medium Tensile steel bars Nos reqd = 7.00/0.15+1=48 Nos10 mm horizontal barsNos reqd = 2.80/0.10 = 1 = 29 Nos
28Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete
29Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size) 20.83+5.54/2 = 4.185
3012 mm thick cement plaster in cm 1:4 on external surface (20.50+15.50)2= 72.00 On wall surface (0.25+0.20) = 0.90 On column surface (0.2x2+0.25 = 0.65 On beambs
31Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes RafterMS rectangular hollow tubes 100/50 mm4.05 mm thickv1.5+15.25=15.32m L = 15.32+0.90x2 = 17.12Purlins MS rectangular hollow tubes 76.2/50.8 mm 3.65mm thick cleatsMs rectangular hollow tubes 40/25mm 3.25 mm thick Base Plate (MS plate6mm thick) Gusset plate 02 for out late pipe 02 for wash out pipe.
32Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.12.1.1 1.00 mm thick with zinc coating not less than 275 gm/m²
33Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. 30x30x4mm for posts for wire mesh Gabble sides at ht = 1+1.5x2=0.75Front side Door = (0.90+1.30) x 2 = 4.40 FI 30x4 mmHard Drawn steel wire fabric of required meety of size 50mm with dia of wire 3.00 mtr each way 50x50x6mm for ladderL = 3030x2+0.30 = 6.902/0/0/60=12.00 mtr
34Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. L = 20.00+0.35x2+1.00x2=22.70Total L=22.70x2+15.70x2+76.80
35Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc. complete 125x65x2.12mm
36Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete
37Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete
38Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. kg 88.50
39Extra for providing and fixing wind ties of 40x 6 mm flat iron section
40Finishing walls with water proofing cement paint of required shade :13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
41Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 13.61.1 Two or more coats on new work sqm
42Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Mild steel and medium tensile steel bars4.185/0.15+1=29 Nos1.36/0.15+1=10 Nos
431:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal sizederived from natural sources) cum 6833.40
44Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : 7.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 6653.45
4520 mm cement plaster of mix :13.3.1 1:4 (1 cement: 4 fine sand) sqmL=0.40+5.00+0.40+1.87+0.40=8.07, ht=0.60+0.40=1.00
4612 mm cement plaster finished with a floating coat of neat cement of mix :13.7.1 1:3 (1 cement: 3 fine sand) sqm
4712 mm cement plaster of mix : 13.1.1 1:4 (1 cement: 4 fine sand) sqm
48Steel reinforcement for R.C.C. work including straightening, cutting, 12mm and @ 10cm C/C both way for the floor Nos reqd= 20.25/0.10 +1=204.Nos 15.25/0.15=154 Nos deduction for mild portion at L/4 10.125/0.10+1=102 Nos 7.625/0.10=77 Nos12mm @ 10c/c as vertical external walls (15.25+20.25)x2=71.00nos reqd 71/0.10+1=711 Nos Buffler walls=(15.25/0.10+1=153.00 Nos ht = 3.00+0.3+3.30 10mm lb as in horinzontalbar L+71.00mtrNos reqd +3.70/0.15+1=26 NosBuffle wall L=15.25 mtr nos reqd=3.00 /0.15+1=21 Nos 12 mm@ in corner bar 10 mm c/c both gaps0.62/0.10 = 06 nos12mm in culumn
49Ditto as in item nmo 4 corner concrete L= 70.00mtr
50Finishing wall with water proofing cement paint, two or more coats applied @ 3.84 kg/ 10 sqm
51Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
52Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)
53Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail