Tender For Repair/Maintenance Of Lt Distribution Network And Street Lights Fitting At 39 Gtc Varanasi Under Ge (East) Prayagraj., varanasi-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Lt Distribution Network And Street Lights Fitting At 39 Gtc Varanasi Under Ge (East) Prayagraj.. Submission Date for this Tender is 10-02-2024. Street Lighting Tenders in varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41616559
Corrigendum : Tender For Repair/Maintenance Of Lt Distribution Network And Street Lights Fitting At 39 Gtc Varanasi Under Ge (East) Prayagraj.
Open Tender
Indian
Uttar Pradesh
varanasi
10-02-2024

Tender Details

Tender For Repair/Maintenance Of Lt Distribution Network And Street Lights Fitting At 39 Gtc Varanasi Under Ge (East) Prayagraj.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 100000.0 /-
Tender Value
INR 50 Lakhs /-

BOQ Items

Name of Work: Repair/maint of LT distribution network and street lights fitting at 39 GTC Varanasi unser GE (East) Prayagraj.
Sl. No. Item Description
1Excavation in trenches in soft/loose soil not exceeding 1.5 M wide and not exceeding 1.5 Mtr deep and getting out including filling bottom surface to required level or slope for laying of pipes/ cables complete all as specified and directed.
2Returning filling including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft soil complete all as specified and directed.
3Removing excavated surplus soil not exceeding 50 Mtr and depositing where directed ata level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
4M&L for sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches including punning the sand upto 18 cm thick and consolidated complete all as specified and directed.Note :Punned thickness18 cm shall be measured only.
5Supply and laying dry well burnt locally available brick sub class "B"od size bricks, laid flat with width equal to the length of whole bricks over cable as cable protection complete all as specified and directed.
6M&L for boring holeunder PCC road/ taxi track/ runway/ hard standing upto thedepth 450mm to 1200 mm for passing cable through / insertion of80/50mm dia GI pipe complete all as directed by Engineer-in-charge. NOTES :- (i)Cost of equipments, tools & plants,material required for boring shall deemed to be included in unit quotedrates. (ii)GI pipe shall be measured and paid separetely.
7S&F 32 mm dia GI pipe "light grade" ISI markedfixed on wall/pole or laid in trenches under road crossing/hard standingcomplete all as specified and directed.
8Ditto all as per item No. 07 above but 50mm GI pipe.
9Ditto all as per item No. 07 above but 80mm GI pipe.
10S&F in repairservice cable of size 4 sqmm 2 core,1100 volts grade,heavy duty cable with PVC insulated solidaluminium conductor served with an inner sheathing of PVC tape and overall PVCsheathed complete all as specified and directed.
11Ditto all as per item No. 10 above but 6 sqmm 2 core cable.
12Ditto all as per item No. 10 above but 10 sqmm 2 core cable.
13Supply anderrection of steel tubular pole (in repair)swaged type 410-SP 31(9.0m long pole)as per IS:2713 (part I to III) 1980with cast iron base plate, pole cap, mild steel bolt, nuts and screws including dismantling of exsiting pole complete all as specified and directed. The quoted unit rates includes the following works:- (i) Earth work (excavation, returning filling and removing surplus soil) required for pole foundation in soft/loose soil. (ii) PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) in foundation of size 900mmx600mmand planting depth 1.5 mtr below for concrete encasing the pole. (iii)PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) for plinth block/collar above GL, 500mm high and 450mm diaaround the pole. (iv) Painting of pole externally with one coat of black bituminous paint (upto planting depth before erection) and with two coat of aluminium paint over a coat of red oxide primer above plinth block /concrete collarincluding preparation of surface. (v)Marking 05 Nos 30 cm wide bands/ stripsin alternate layer with synthetic enamel paint of two shade/ coloursupto the height of 1.5mm above plinth block. (e) Writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of apprised shade for numbering of pole ( height not less than 5cm) NOTE : Manufacture"s test certificate will be produced before execution work.
14Supplying ,laying, commissioning & testing 16 Sqmm, 4.0 core XLPE cable insulated armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including taking down old / unserveciable existing cablecomplete all as specified & directed. Note:Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ.
15Ditto all as per item No. 14 above but 10 sqmm 4 core cable.
16Ditto all as per item No. 14 above but 10 sqmm 2 core cable.
17Ditto all as per item No. 14 above but 6 sqmm 2 core cable.
18Ditto all as per item No. 14 above but 240 sqmm 3.5 core cable.
19Ditto all as per item No. 14 above but 150 sqmm 3.5 core cable.
20Ditto all as per item No. 14 above but 120 sqmm 3.5 core cable.
21Ditto all as per item No. 14 above but 95 sqmm 3.5 core cable.
22Ditto all as per item No. 14 above but 70 sqmm 3.5 core cable.
23Ditto all as per item No. 14 above but 50 sqmm 3.5 core cable.
24Ditto all as per item No. 14 above but 35 sqmm 3.5 core cable.
25Ditto all as per item No. 14 above but 25 sqmm 3.5 core cable.
26M&L in repair cross arms bracing, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling hole for bolts, in any shape or size as indicated or directed and inclusive two coat of aliminium paint over a coat ofprimer including taking down of exsiting cross armscomplete all as specifiedanddirected.
27M&L for repairing ofindoor/outdoor electric panel of any size/type,removing dust,dirt by cleaning/scrubbing inside outside,welding as required, replacing burned out screw/nut bolts as required for smooth closing of panel doorrincludingpaintingexternaly with one coat of synthetic enamel paint after preparation of surface also without disturbing the existing fittings and fixture , proper taping to incomming outgoing LT UG conductor with flexible tape/ insulation tape and marking/ writing letter such as SM No. capacity etc,with safety precaution completeall as specified & directed.
28S&F in repair rubberinsulating matting as per ISI Mark (size 1m x 2m x19 mm)suitable for voltage upto 11 KV including taking down old/unserviceble insulating matting complete all as specified and directed.
29M&L for painting of9.00 mtr long steel tubular pole including cross arms, clampsof any length and shape foroverhead line/street light andwith two coat of aluminium paint after priparation of surface , marking pole number in a 15cm dia yellow circle and zebra painting with three black & two yellow bends of 30 cm width ulternatibly by fluorescent paintstarting from top of the coping of pole, applying one coat of white wash on coping with safety precaution complete all as specified & directed. Note - All the instruments and T&P required for the above job shall be arranged by the contractor at site including Ladder,Safety Harness and cost of the above deemed to be included in the rates.
30S&F in repair sheet metal enclosure (DB)VTPNtype for MCCB, double door 415 Volt with 200 amp rated bus barsuitable for1 x 63Amp MCCB as incomer and MCB SPN as outgoingcomplete all as specified and directed. NOTE : MCCB and MSBs shall be measured and paid seperatly under respecitve item of BOQ.
31S&F MCCB 63 Amp,4 pole ,415 VoltISI marked conforming to "B" curve, breaking capacity 16 KA complete all as specified and directed.
32S&F in repair ACB,4 pole, 415 volts, 630Amps,with thermal megnetic release ((Manual Fixed type) breaking capacity 50 KA,complete all as specified and directed.
33S&F in repair MCCB, 4 pole, 415 volts, 400 Amps,breaking capacity 50 KA, with thermal magnetic release adjustable type complete all as specified and directed.
34S&F in repair MCCB , 4 pole, 415 volts, 250 Amps,breaking capacity 35KA/36 KA, with thermal magnetic release adjustable type complete all as specified and directed.
35S&Fin repair MCCB , 4 pole, 415 volts, 200 Amps,breaking capacity 35KA/36 KA, with thermal magnetic release adjustable typecomplete all as specified and directed.
36S&F in repair MCCB , 4 pole, 415 volts, 160 Amps,breaking capacity 35KA/36 KA, with thermal magnetic release adjustable type complete all as specified and directed.
37S&F in repair MCCB , 3 pole, 415 volts, 100 Amps,breaking capacity 35 KA/36 KA, with thermal magnetic release adjustable type complete all as specified and directed.
38S&F in repair MCCB , 3 pole, 415 volts,63 Amps, breaking capacity 25KA, with thermal magnetic release adjustable typecomplete all as specified and directed.
39S&Fin repair MCB TPN, 4 pole, 415 volts, 63 Amps,"B" curve 10 KAserviceble MCB complete all as specified and directed.
40S&F in repair LED integral flood lightluminaires 200 watt in powder coated with aluminium die casthousing and frame,high efficiency,long life LEDs,loop in loop out connector,10 A G.F.P for each wiring heat resistanttoughned glass in the front with unique flood optics to ensure uniform distribution and IP 66 protection complete assembly with LEDs,driver and accessaries pre wired up to terminal block including connection on polecompleteall as specified and directed. Make- Orient cat No. - ALPHA-LFAP-200-C or techno-commercially equivalent model in any make as approved by GE
41S&F in repair LED street lightluminaires 60 watt with pressuredie cast aluminium housing with heat resistanttoughned glass and IP66 protection complete including connection on pole or buildingcompleteall as specified and directed. Make- Crompton cat part No- LST-60-CDL-M, Havells Cat Part No.- LHETAXU7PN6J060
42S&F in repair LED street lightluminaires 90 watt with pressurealuminium -die- cast powder coating housing & frame with heat resistant,high efficiency toughned glass with EPDM gasket forIP66 protection complete assembly with LED ,driver& accessories pre-wiredup to terminal block including connection on pole or building completeall as specified and directed. Make- Crompton cat Part No.- LSTP-90-CDL orHavells cat Part No.- LHETAXU7IN6J090 or C&S cat Part No. LTESS40X25HPLED/LS
43M&L forsheet metal enclsure (Feeder pillar box), outdoor type, made out of3 mm thick powder coated CRCA sheet, with hinged door& locking arrangementfixed on MSframe made of angle iron of size 40 X 40 X 6 mm having 90cm long lagsgrouted/embeded 30cm below GL ( 60 cm above ground level) in PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) duly painted exposed surfaces of framwith two coat of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed. Feeder pillar box shall comprising the following:- (i) 4x aluminium bus bar of rating 200 Amp mounted on insulator. (ii) 1x MCCB 4 pole 63 Amp 415 volts with thermal magnetic release breaking capacity 25 KA as incomer,
44S&F in repair off load type change over switches panel mountedin open execution, front operated rotary handleof 200 Amp rating, 4 pole, 415 Volt complete all as specified and directed.
45S&Fin repair off load type change over switch panel mountedin open execution, front handle operated of 100 Amp rating, 4 pole, 415 Voltcomplete all as specified and directed.
46S&Fin repair onload type change over switch in open execution, side handle operated of 100 Amp rating, 4 pole, 415 Voltcomplete all as specified and directed.
47S&Fin repaironload change over switch in open execution, side handle operated of 63 Amp rating, 4 pole, 415 Voltcomplete all as specified and directed.
48M&L forrepair of fault in in HT/LT UG cableof any size after Locating faultusing Fault locator Megger machine, preparing both ends of cable for connrcting to the jointing kit including necessary earth work, if required complete all as specified anddirected . NOTE : (i) All the instruments,and T&P required for the above job shall be arranged by the contractor at site and cost of the same deemed to be included in the above rates. (ii) Jointing kit shall be measured and paid seperatly under respective item of BOQ.Contractor should be provide two labours for Joining and dismentling of cable at both the end and excavation above the faulty cable if reqd
49Supply, jointing and testing cable jointing kitcable for cable end termination heat shrink type joint complete with jointing material & accessories suitable for 1100 volt grade XLPEcable of size 25 sqmmto 50 sqmm 3.5 corecomplete all as specified and directed.
50Ditto all as per item No. 49 above but suitable for cable of size 70 sqmmto 120 sqmm
51Ditto all as per item No. 49 above but suitable for cable of size 150 sqmmto 185 sqmm
52Ditto all as per item No. 49 above but suitable for cable of size 240 sqmmto 300 sqmm
53Ditto all as per item No. 49 above but suitable for cable of size 400 sqmmto 500 sqmm
54Supply, installation and testing of factory made, CPRI Approved cubical outdoor (Kiosk) type feeder pillar box 415 volt, 4 wire, AC 50 Hz, made out of 3.15 mm thick CRCA sheet, weatherand vermin proof powder coating finish bothside(interior & exterior) for outdoor mounting withhaving degree of protection as per IP-56 complete factory lock two earth terminal suitable cable gland for all incoming and outgoing and removable neutral link, Both Side openable double door Indicating light LED type RYB - 01 Set, Ammeter-01, Voltmeter-01, connecting strip/solid conductor brought out to cable chamber brass/copper nut, bolts/washer etc , placing /fixing feeder pillar box 60 cm above ground level onsuitable size angle iron stand made up of65 x 65 x 6 mmembedded in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) upto depth not less than 30 cm includingnecessary excavation and earth work complete all as specified and directed.Feeder pillar box shall comprises the following asseccories:- (a) copper insulatd busbar high conductivity 400 Amp rated 4 phase including neutral bus bar complete - 01 No. Incoming :- (b) MCCB4 -pole 250 Amp make-Havells ,415 Volt,breaking capacity 36 KA,50 HZ with thermal magnetic release - 01 No. Outgoing :- (c) MCCB 4 - pole 160 Ampsbreaking capacity 25 KA, 50 HZ- 01 Nos. (d)MCCB 4 - pole 125 Ampsbreaking capacity 25 KA, 50 HZ- 03 Nos. (e)MCCB 4 - pole 63 Ampsbreaking capacity 25 KA, 50 HZ- 01 Nos.
55Earthing complete with GI earth plate electrode 600mm x 600mm x 6mmthick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth lead of 24x4mm flat iron strip by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 15mm dia GI pipe "medium grade", GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:2:4) type B-1 earth chamber and mild steel angle iron frame 25mm x 25mm x 6 mm and40mm thick pre-cast RCC cover (1:2:4), type B-1 (using 20mm graded crushed aggregate) mix with 6mm dia MS bars @75mm c/c both ways, mild steel handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe light grade(ISI marked) for watering, etc complete all as shown in electrical plate No.3 of SSR Part-1, connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- The quoted rates shall also deemed to include the cost of Earth Test point and earth wire and protection pipe upto 7.5 metre beyond the earth plates electrode.
56All as per item No. 55 above butusing 4mm dia GI wire as earth lead.
57S&F in repair sheet metal enclosure factory fabricated compartmental , recess/wall mounting type made with 3.0mm thick CRCA sheet, powder coated epoxy painted, protection class IP-65of size of size 900mm x 750mm x 200mm for fixing 04Xelectric energy meter (one in each compartment) complete all as specified and directed. The encloser have comprisesof the following:- Provn of1 x 63A four pole MCCB 25KA with adjustable thermal magnetic release as incommer, (ii) Copper bus bar, 200A rating 415 V TPNmounted on heavy duty porcelene insulators. (iii) 3x LED indicator lamps andthree phase 415 Volts 96 X 96mm tin case 80mm depth (iv) Digital electronic Volt meter accuracy class 1.0 with built-in selector switch flush mouting (v) Provn of 4 x compartment of apropriate size, each compartment shall suitable for mounting of1x energy meter and 1x40 Amp Two pole MCB and having single door front opening seperatly and fixed with PU gasketwith individual locking arrangement, cut to shape and fixed with 1xtoughned clear glass sealed with PU/PVC gasketto visualise the energy meter without opening the door. (vi) cable glands suitable for 16 to 70 Sqmm 4 core as one incoming cableand 4 ways for outlet. in each compartment. (vii) Refixing the electric energy meter in each compartment incl internal rewiring with 10 Sqmm single core multi stranded FRLS copper conductor cable for all meters, MCBs and MCCBswith proper end termination lugs etc. NOTE : (a) Old meters, MCB, MCCBs shall be used for refix, The cost oftaking out thease accessories from old panel, any other location etc deemed included in the unit quoted rates.
58M&L for Earth continuity conductor or main earthing lead made out of 25x4mm galvanised iron strip, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required completeall as specified and directed.
59M&L for loose filling spreading and leveling hard core 40mm graded corse aggregate completeall as specified and directed
60M&L for surface excavation in soft/loose soil not exceeding 30cm deep and averaging 15 cm and getting out including leveling the surface completeall as specified and directed.
61S&F Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole completeall as specified and directed.
62S&F Danger notice plate of 20x15cm size, made out of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT completeall as specified and directed.
63Ditto all as per item No. 62 above but suitable for HT of size 25x20cm
64Cleanning of grass, surbs, bushes small trees etc from inside the installations as well as around the installation premisses (max upto the 2 mtr all around the wall), removing garbage and depostingwhere directed complete all as specified and directed. Note-Necessary T&P shall be provided by the contractor and rates are deemed to be included the quoted rates.
65Repairing of existing non functional LED security/ street light fittings fixed on pole/ wall/ pipe of any type & wattage by means of removing cabon on contacts, tightning loos connection, replacing unserviceable accessories like SPD, LED Driver etc, tightening of brackets, clamp and includingtesting after refixing the fitting and reconecting electric connection, complete all as specified and directed. NOTE : (i) Accessories required for replacement shall be measured & paid separately under respective items of this BOQ. (ii) The cost of diconnecting electric connections, taking down, dismantling reassembling , refixing of fitting, reconnection of electric connections if required , minor items like nut, bolt, washers, screws insulation tap etc shall deemed included in quoted unit rates. (iii) connecting electric wire / cable, if required to replace shall be measured and paid in relevent items of BOQ. (iv) Any type of T&P like Ladder etc or arrangement for dismantling of light from pole/ hanger pole shall be arranged by the contractor cost of the same demmedincluded in quoted unit rates.
66S&F in repair surge protection device 10 KV, suitable for LED street lights of capacity 45 watt to 250 watts, single phase, 230 volt, 50 Hz, AC supply complete all as specified and directed.
67S&F in repair LED street light/Flood light fitting driver/ choke 36/40/45/60 watts, 240 volts AC 50 Hz electronic typecomplete all as specified and directed.
68S&F in repair LED light fitting driver/ choke 70/75 watts, 240 volts AC 50 Hz electronic typecomplete all as specified and directed.
69S&F in repair LED street light/Flood light fitting driver/ choke 90 watts, 240 volts AC 50 Hz electronic type.complete all as specified and directed.
70S&F in repair LED street light driver/ choke 25/30 watts, 240 volts AC 50 Hz electronic typecomplete all as
71S&F in repair LED street lightluminaires 25 watt with pressuredie cast aluminium housing with heat resistanttoughned glass and IP66 protection complete including connection on pole or building including taking down of old /unserviceble street light fitting complete all as specified and directed. Make- Crompton Cat Part No-LSTS-25-CDL/NL-M, Havell Cat Part No.- LHETAXU7PA6J025, Bajaj Cat part No. ENXT P 25L WH PO PC SD.
72S&F in repair LED street lightluminaires 35 watt with pressuredie cast aluminium housing with heat resistanttoughned glass and IP66 protection complete including connection on pole or building including taking down of old /unserviceble street light fitting completeall as specified and directed. Make- Bajaj Cat part No. ENXT P 35L WH PO PC SD or Crompton cat No- LSTS-36- CDL-M or techno-commercially equivalent model in make Havells/Wipro
73S&F in repairGI bracket for security light & street light fittings fabricated with GI tubing 40 mm dia "medium grade" 1.2 m long includingand bending to angle of 120 degree complete all as specified and directed.
74S&F in repair mild steel clamp fabricated with mild steel flat iron 50mm x 6 mm including nut and bolts with washer suitable for fixing of GI bracket on PCC/ steel poles complete all as specified and directed.
75Fixing only in repairold street light GI pipe/ bracket with clamp and nut, bolt, washers etcin same or in other locating complete all as specified and directed. Note : (i) New nut/ bolt/ washers if required shall be provided by the contractor and quoted rates shall deemed included the same.
76S&F in repair hot press moulded PVC junction box of size 230mm x 170 mm x 105 mm with 200A TPN Aluminium bus bars mounted/ fixed on porcelien insulator shock and rust proof,cable entry from bottom and other sides, 100% weatherproof, with pole mounting arrengement temperproof,fire retardant class FV-0 as per IS 11731 part -II or V-O as per UL-94 including flat iron clamp of size 25 x 3 mm with nut and bolt, washers complete all as specified and directed.
77S&F in repair Electronicstreet light Astronomical control timer switch, operating automatic/ mannuallyof capacity 6 KW, conforms to IS/IEC 60947-4-1, 3 phase, 415/230 volts, 50 Hz, ISI markedwith sheet metal encloser box wall/pole mounting type including heavy duty clamp made out of mild steel sheet 3.15 mm thickduly painted with two coat of synthetic enameled paint over a coat of red oxide primer suitable to accommodate the following :- (a) Three phase control switch MCB TPN 40A 10 KA - 01 No (Incoming) (b) Auto/Manual control switch (c) Heavy duty 3 Phase Contactor ML-3 with axulllary contact - 01 No (d) sun light senser cat eye type complete to operate before sun rise & after sun set (d) Astronomical Timer - 01 No. Make - Havells cat Part No - IHXTS0306A or equivalent make in L&T, Legrand
78S&F in repair energy saving LED garden light fitting, decorative, bollard ofcapacity 10 watt with opal diffuser & aluminium reflector complete with all accessaries and fixing arrengement on PCC blockalogwith fixing nuts, bolts and4.0 sqmm 2core PVC insulated aluminium conductorcable complete all as specified and directed. Make - Orient Step Bollard Cat part No.LLSBL-10-W or Crompton Cat Part No. LBLA3-10-CDL or Bajaj Cat part No. BGBOM 1000 9W LED WW ortechno commercial equivalent make in Havells/C & S
79Taking down existing non functional high mast/semi High mast pole light any type/wattage for repair including replacement of unserviceable spares/accessories like ballast, starters, ignitors, lamps, service connection etc & errecting the same after cleaning & greasing of SWR rope in position after complete repair and testing complete all as specified and directed. NOTE :(i) Replacement and fixing of unserviceable component etc required will be measured & paid separately under respective items of this schedule. (ii) Fitting shall be connected with existing electric wire / cable, in case of existing wire / cable found unserviceable same shall be measured and paid seperatly in relevent items. (iii) Any type of Ladder or arrangement for dismantling of light from pole/hanger/high mast pole shall be arranged by the contractor.
80M&L for Rewinding ofmotor with super enameled copper wire of high mast light any type (gauge/weight of copper coils shall be same as per existing dismantled motor strata), including varnishingcomplete all as specified and directed by Engineer-in-Charge. Notes :- (a) Removing the defective motor & rectifying after repair including removing defective parts, burnt winding carefully, cleaning & re-assembling the motor after repair/servicing including oiling, greasingetc.complete to the entire satisfaction of Engineer-in-charge.
81S&F in repair PVC insulated & FR PVC roundstranded sheathed conductor copper multi core round (flexible) industrial cable 1100 volt with bright concealed electrolytic bare copper conductor for voltage 1100 volts grade of size 16 sqmm, 4 core confirming to IS-694-1990 on semi high/high mast poles of any height and connecting complete all as specified and directed.
82S&F in repairPVC insulated & FR PVC round stranded sheathed conductor copper multi core round (flexible) industrial cable 1100 volt with brightannealed electrolytic bare copper conductor for voltage 1100 volts grade of size 10 sqmm,4 core confirming to IS-694-1990 on semi high/high mast poles of any height and connecting complete all as specified and directed.
83S&F in repair LED integral flood light luminaires 170 watt in powder coated with aluminium die casthousing and frame,high efficiency,long life LEDs,loop in loop out connector,10 A G.F.P for each wiring heat resistanttoughned lear glass cover and IP 66 protection complete assembly with LEDs,driver and accessaries pre wired up to terminal block in control gear compartment including connection on pole or buildingcompleteall as specified and directed.
84Supply and fix in repair LED integral flood light luminaires 120 watt in powder coated with aluminium die casthousing and frame,high efficiency,long life LEDs,loop in loop out connector,10 A G.F.P for each wiring heat resistanttoughned lear glass cover and IP 66 protection completeassembly with LEDs,driver and accessaries pre wired up to terminal block in control gear compartment including connection on pole or building including taking down of old /unserviceble street light fitting completeall as specified and directed. Make- Wipro Cat Part No-LR18-132-XXX-57-XX, C&S Cat Prat No.- LTEFI120WHPLED, Havells-LHEPCZU7P46J120.
85S&F in repair under water luminiaries 7 watt LED lightfor connecting under water lighting purpose of fountain, Corrosion resistant, Nickel plated brass housing, water proof with flanges of top coloured glass with rubber gasket on both sides , mounted in brass framewith all accessiories and LED complete all as specified and directed.
86Trimming of tree branches touching to overhaul bare electric condutor lines/ electric installation to thr entire setisfection of Enng-in-charge, removing the garbage and depostingwhere directed complete all as specified and directed. Note-(i) Proper safety kit and cuttings tools, ledder, electric saw/generator set, wire rope etc shall be provided by the contractor and rates are deemed to be included the quoted rates. (ii) contractor shall insure Taking proper electric shutdown from the department befor strting this work and detail a apropriate person to keep close monitoring of shutdowm during the work. after closing the work he shall responcible to report engineer -in-charge/ JE concernfor restoration of shutdown.