Tender For Repair/Maintenance/Servicing Of Summer/Cooling Appliances At Ch (Cc) Cmdc Sho Echs Base Hosp And Other Area Of Age E/M (Hosp) Under Ge E/M Lucknow, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/Maintenance/Servicing Of Summer/Cooling Appliances At Ch (Cc) Cmdc Sho Echs Base Hosp And Other Area Of Age E/M (Hosp) Under Ge E/M Lucknow. Submission Date for this Tender is 08-02-2024. Air Conditioner Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41596758
Corrigendum : Tender For Repair/Maintenance/Servicing Of Summer/Cooling Appliances At Ch (Cc) Cmdc Sho Echs Base Hosp And Other Area Of Age E/M (Hosp) Under Ge E/M Lucknow
Open Tender
Indian
Uttar Pradesh
lucknow
08-02-2024

Tender Details

Tender For Repair/Maintenance/Servicing Of Summer/Cooling Appliances At Ch (Cc) Cmdc Sho Echs Base Hosp And Other Area Of Age E/M (Hosp) Under Ge E/M Lucknow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINT/SERVICING OF SUMMER/COOLING APPLIANCES AT CH (CC) CMDC SHOECHS BASE HOSP AND OTHER AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW
Sl. No. Item Description
1Attending the Complaints of Split AC/ Window AC/ Tower AC by AC mechanic at any location of Cantt area complete all as directed by EIC
2M&L for dismantling of burnt contactor and Supply & fix power contactor 1ph suitbale for Tower AC/ split AC/ Window AC of any make , model and capacity complete all as specified and directed by Engineer-in- Charge.
3M&L for dismantling of defective outdoor stand of split ACand supply & fixing outdoor stand of split AC at suitable location complete all as specified and directed by EIC.
4M&L for dismantling of burnt capacitor and Supply & Fix capacitor of capacity 36 Mfd in plastic/ metal container complete all as directed by EIC.
5M&L for dismantling of burnt capacitor and Supply & Fix capacitor ofcapacity 50+5Mfdin plastic/ metal container complete all as directed by EIC.
6M&L for dismantling of burnt capacitor and Supply & Fix capacitor ofcapacity 45 Mfdin plastic/ metal container complete all as directed by EIC.
7M&L for dismantling of burnt Indoor unit Censor and Supply & Fix Censor (in each set) of Indoor unitSplit ACInverter type (Cooling / Hot and cold type)of any make and model for 1.5 TR / 2 TR capacities completed all as directed by EIC.
8M&L for dismantling of burnt Outdoor unit Censor and Supply & Fix Censor (in each set) of Outdoor unitSplit ACInverter type (Cooling / Hot and cold type)of any make and model for 1.5 TR / 2 TR capacities completed all as directed by EIC
9M&L for dismantling of burnt Swing motor and Supply & Fix Swing motor for 1.5 TR / 2 TR indoor unit of split AC all as directed by EIC.
10M&L for dismantling of burnt Swing motor and Supply & Fix Swing motor for 1.5 TR / 2 TR indoor unit of split AC Inverter type (cooling only / hot & cold type) all as directed by EIC.
11M&L for dismantling of burnt Swing motor and Supply & FixSwing motor for 1.5 TR / 2 TR window AC all as directed by EIC.
12M&L for dismantling of defected brass suction valve and Supply & fix brass suction valve size 3/8" complete all as specified and directed
13M&L fordismantling of defected Discharge valve and Supply & fix Discharge valve size 1/2" complete all as specified and directed .
14M&L for dismantling of defectedcharging valve and Supply & fix charging valve size 1/4" complete all as per directed by EIC
15M&L for dismantling of defected flare nuts and Supply & fix flare nuts size 3/8" complete all as specified and directed
16M&L fordismantling of defected flare nuts and Supply & fix flare nuts size 1/4"complete all as specified and directed
17M&L fordismantling of defected flare nuts and Supply & fix flare nuts size 1/2" complete all as specified and directed
18M&L fordismantling of defected flare nuts and Supply & fix flare nuts size 5/8" complete all as specified and directed
19M&L fordismantling of defected copper gas filter and Supply & fix copper Gas filter for AC 1.5 TR / 2 TR capacity all as specified and directed
20M&L for dismantling of burnt connector and Supply & fix connector suitbale for Tower AC/ split AC/ Window AC of any make , model and capacity complete all as specified and directed by Engineer-in- Charge.
21M&L for renew PVC insulated three core stranded copper cable of size 80/0.20 ( 2.5 sqmm)all as specified and directed .
22M&L for renew MCB SP -6 to 32 Amps ratingto be housed in DBs catered here in after complete all as specified and directed :-(Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating):-
23M&L for renew Mettalic Plugs ( top) of AC box 20A, specified make , 2P+Eand connectingall as specified and directed
24M&L for repair/ renew copper capillary of size 0.60 mm complete all as specified and directed
25S&F in repair plug and socket DBs with single pole MCB rated 32 Amps capacity with socket plug top 2 pin and earth plug complete all as specified including making niche in wall and mounted flush complete all as specified
26M&Lfor copper tube leaked repaired of Tower AC, Split AC, Window AC of 1.5 TR/ 2.0TR capacity any make and model at any location of cantt area after repaired of tube by brazing, testing of leakage, vaccumnisation andcharging full/ top up of refrigerant (R-22/R-32/R-410) required to make it fully functionalcomplete all as directed by EIC. Note :- Refrigerant gas will be provided by Contractor
27Supply only of puff insulation of size1/2" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC
28Supply only of puff insulation of size1/4" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC
29Supply only of puff insulation of size5/8" suitable for 1.5 TR/2.0 TR Ac complete all as per specified and directed by EIC
30Supply and fix PVC pipe nylon imbraided 15 mm dia forcondensed waterdrain fitted with clamps/concealed in wall all as specified and directed.
31Supply and fix in repairof copper tubing 3/8"diawith puff insulation complete all as specified and directed .
32Supply and fix in repairof copper tubing 1/2" dia with puff insulation complete all as specified and directed .
33Supply and fix in repairof copper tubing 1/4" dia with puff insulation complete all as specified and directed .
34Supply and fix remote hand set of window type air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed (Make:- LG / Samsung / Bluestar)
35Supply and fixremote hand set of Split type air conditioner of cap 1.5/2.0 TR of existing make with and includingpencil cells complete all as specified and directed
36Supply and fixremote hand set of Inverter type Split air conditioner of cap 1.5/2.0 TR of existing make with and includingpencil cells complete all as specified and directed
37Supply and fix in repair Air Censor for temperature control for 1.5 TR/ 2.0 TR Split AC/ Tower AC/ Window AC complete all as specified and directed.
38Supply and fix PVC fan blade with gun metal bush of blower , Screw complete as per complete all as directed by EIC
39Supply and fixPVC blower for window A.C. as per sample complete all as specified and directed
40M&L for taking down of Split type AC (Indoor & outdoor complete) of any capacity or model and transporting and refixing at New Location to make it fully functional again at new location withall as specified and directed by Engr-In -Charge.
41M&L for taking down of Window AC any capacity or model, transporting and refixing at New Location to make it fully functional again all as specified and directed by Engr-In -Charge.
42Taking out defective blower motor from window type AC of cap 1.5/2.0 TR and transporting defective motor of any make & capacity from site to contractor workshop dismantling the burnt winding & rewinding of 1 / 5 to 1 / 8 HPblower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed.
43Dismantling of burnt blower motor of 1.5 TR/2.0 TR split AC ( indoor unit)and supply & fixing new blower motor Suitable for Carrier/Voltas/Blue star/LG/Samsung MakeACs as per sample complete all as specified and directed.
44Dismantling of burnt outdoor fan motor of 1.5 TR/2.0TR split AC (outdoor unit)and supply & fixing new outdoor fan motor Suitable for Carrier/Voltas/Blue star/LG/Samsung MakeACs as per sample completeall as specified and directed.
45Dismantling of defective indoor unit of 2.0 TR capacity Tower AC and supply & fixing new indoor unit Tower AC of the same capacitywith blower motor, front grill, Remote hand set with pencil cell, flexible cable and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit all as specified and directed.( Make :- Bluestar/ Voltas//LG/ Hitachi)
46Dismantling of existing window type AC. from its location andrefixingafter doing by Servicingby oiling & cleaning with liquid soap , cleaning of fins by means of air blower and water with pressure jet and changing of air filtercomplete with cleaning of Cooling & Condensing coil all as directed by EIC.
47M&L forpainting of outer cage and front grillof window type AC or indoor unit & outdoor unit of Split type AC or Tower AC of any make & capacity with two coats of synthetic enameled paint of approved shade and tint including preparation of steel surface by emery paperincluding writing SM No. / MES No. etc complete all as directed by EIC
48Taking down outdoor unit of Tower Ac/ split AC any make/ model/ capacity and transporting from site to contractor workshop for carrying out repairs and renewal/ replacements of Parts including servicing and liquid soap washing, after repaired the same, transporting back to site, required to make it fully functional reassemble and installation on existing same location with complete all as specified and directed. (Note :- M&L for parts renew/ replacements shall be measured and paid separately under appropriate item(s)
49M&Lfor Water dropping leaked repaired of Tower AC, Split AC, Window AC of any make, model and capacity by AC mechanic at any location of cantt area with complete all as directed by EIC
50M&Lfor convert to heating/ cooling mode (only reverse cycle connection) in Split AC, Window AC of any make, model and capacity by AC mechanic at any location of cantt area with complete all as directed by EIC
51M&L for Renewal ofplywood 6 mm thick,BWR, grade 1, one side decorative teak veneers and other side commercial veneered finished to cover space of window or wall for fix of window AC any capacity to complete as directed by EIC
52M&L for Renewal of2nd class HW (SAL) fillets, cross sectional area excd 3 and not excd 6 sqcm on all four sides of window type AC splayed or chamfered edge including polishing etc complete all as specified and directed.
53Dismantling of defective indoor unit of 1.5 TR capacity split type AC and supply & fixing new indoor unit Inverter type (hot & cold) type of the same capacitywith blower motor, front grill, Remote hand set with pencil cell, flexible cable and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit in wall/ceiling mounted all as specified and directed.( Make :- Bluestar/ Voltas//LG/ Hitachi)
54Dismantling of defective cooling coil of 1.5 TR/2.0 TR window type AC of any make and S&Fcooling coil in copper by brazing, leak proove and vaccumination complete all as specified and directed
55Dismantling of defective condencing coil of 1.5 TR/2.0 TR window type AC of any make and S&Fcondencing coil in copper by brazing, leak proove and vaccumination complete all as specified and directed
56Dismantling of defective cooling coil of 1.5 TR/2.0TR Split AC of any make and S&Fcooling coil in copper by brazing, leak proove and vaccuminationcomplete all as specified and directed
57Dismantling of defective condencing coil of 1.5 TR/2.0TR Split AC of any make and S&F condencing coil in copper by brazing, leak proove and vaccumination complete all as specified and directed
58Dismantling of burntfan motor of 1.5 TR/2.0TR window AC double shaft and supply & fixing newfan motor Suitable for Carrier/Voltas/Blue star/LG/Samsung MakeACs as per sample completeall as specified and directed.
59Dismantling of unserviceable compressors of 1.5 TRcapacitiesincluding disconnecting suction / discharge copper tubing and S&F new compressor rotary type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushingby nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii) The electrical accessories required will be measured and paid for separately.
60Dismantling of unserviceable compressors of2 TRcapacitiesincluding disconnecting suction / discharge copper tubing and S&F compressor rotary type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushingby nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii) The electrical accessories required will be measured and paid for separately.
61Dismantling of unserviceable compressors of 1.5 TRcapacities of window/split type ACs including disconnecting suction / discharge copper tubing and S&F compressor reciprocating type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushingby nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii) The electrical accessories required will be measured and paid for separately.
62Dismantling of unserviceable compressors of 2 TRcapacities of window/split type ACs including disconnecting suction / discharge copper tubing and S&F compressor reciprocating type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushingby nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii)The electrical accessories required will be measured and paid for separately.
63Supply and fixing in repairs front grill quality for window AC of 1.5 TR/ 2 TRof Make National/ Casmo/LG/Carrier / Blue Star/Samsung/ Voltas all as specified and directed
64M&L for fabrication of Tray for Window AC made out of 24 SWG 10mm apertureincluding rivetting brazing /soldering including painting with two coat of (black) enameled paint over a coat of red oxide primer and installed at locations complete all as specified and directed.
65Dismantling of defective condensing unit ( outdoor unit) of Tower AC of 2.0 TR capacityand supply & fixing new condensing unit (outdoor unit) of Tower AC 2.0 TR capacitycomplete with compressor, Copper condensing coil, coil frame, wiring kit and running capacitor, relay,condensing motorwith blade and including copper tube with puff insulation of suction and discharge suitable size complete all as directed . ( Make :- Bluestar/ Voltas//LG/ Hitachi)
66M & L for servicing of Split AC, and tower AC s 1.5/2.0/3.0/4.0 TR Indoor/out door unit by means of electric blower & water under pressure,cleaning & washing of cooling/condencing coilby soap solution or recommended chemical ,oiling & greasing of moving parts such as blower motor etc completeall as specified and directed by EIC.
67M & L for Nitrogen pressure testing,flushing out the system by Nitrogen ,vacumrnation andcharging/ topup of refrigerant gas R-22/R-32/R-410 into the system for 1.5 TR/2.0 TR capacity split type AC all as specified and directed. (The refrigerant gas will be providedby Contractor)
68M & L for Nitrogen pressure testing,flushing out the system by Nitrogen ,vacumrnation andcharging of refrigerant gas R-22/R-32/R-410 into the system for 1.5/2.0 TR capacity window type AC all as specified and directed. (The refrigerant gas will be providedby Contractor)
69Supply & Charging in full or Top up the AC unit of 1.5 TR / 2 TR split AC/window AC unit with refrigerant gas R-22/R-32/R-410 in required Qty complete all as specified and directed (The refrigerant gas will be providedby Contractor)
70Supply & fix in repair/ renew of New display suitable for Split AC/ window AC/ Tower AC of any make/ model & capacity complete all as directed by EIC
71Supply & fix in repair/ renew of New display suitable for Inverter Split AC (cooling or Hot & cold type) of any make/ model & capacity complete all as directed by EIC
72M&L for dismantling of defective display of 1.5/2.0 TR capacity Split AC/ Window AC of any make and transporting to contractors workshop for repair of the same,transporting back to site & refixing to ensure proper functioning of the AC complete all as specified and directed.
73Dismantling of burnt blower motor of 1.5 TR/2.0 TR split AC ( indoor unit) Inverter Split AC and supply & fixing new blower motor of Inverter Split AC (Cooling or hot & cold type) Suitable for Carrier/Voltas/Blue star/LG/Samsung MakeACs as per sample complete all as specified and directed.
74Dismantling of burnt outdoor fan motor of 1.5 TR/2.0 TR split AC ( outdoor unit) Inverter Split AC and supply & fixing new outdoor fan motor of Inverter Split AC (Cooling or hot & cold type) Suitable for Carrier/Voltas/Blue star/LG/Samsung MakeACs as per sample complete all as specified and directed.
75S&F reverse cycle solenoid valve in splittype AC 1.5 / 2 TR capacitywithnecessaryextension to suction/ discharge copper tubing & toggle switch complete all as specified and directed by Engineer-in- Charge.
76Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 1.5 TR capacityand supply & fixing new condensing unit (outdoor unit) Inverter type (hot & cold) of the same capacitycomplete with compressor,copper condensing coil, coil frame, wiring kit and running capacitor, relay,condensing motorwith blade and including copper tube with puff insulation of suction and discharge suitable size complete all as directed . ( Make :- Bluestar/ Voltas//LG/ Hitachi)
77S&F in replacement New PCB for indoor unit of (Make-Samsung/LG/Voltas/Daikin/Hitachi/Carrier) of Cap 1.5/2.0 TR Split ACcomplete all as specified and directed.
78M&L for dismantling of defective PCB of 1.5/2.0 TR capacity Split AC of any make from indoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed.
79All as per item 78above but for 1.5/2.0 TR WINDOW AC OF any make.
80S&F in replacement New PCB for window AC of Cap 1.5/2.0 TR of any make/ modelcomplete all as specified and directed.
81S&F in replacement New PCB for indoor unit of (Make-Samsung/LG/Voltas/Daikin/Hitachi/Carrier) of Cap 1.5/2.0 TR Split AC Inverter type( cooling only/ hot & cold) complete all as specified and directed.
82S&F in replacement New PCB for Outdoor unit (Make-Samsung/LG/Voltas/Daikin/Hitachi/Carrier) of Cap 1.5/2.0 TR Split AC Inverter type( cooling only/ hot & cold) complete all as specified and directed.
83M&L for dismantling of defective PCB of 1.5/2.0 TR capacity SplitAC inverter type (cooling only/ hot & cold) of any make from indoor or outdoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC complete all as specified and directed.
84Dismantling desert cooler of any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts & motor, reassembling andinstallation of the same on same location and making electric connection required to make fully functional etc. complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
85Supply only of PVC front grill complete all as specified and directed.
86Supply onlyof Piano switch (5/6 Amp) suitable for desert cooler complete all as specified and directed. ( Make :-Anchor/ABB/Havells)
87Supply onlyof PVC distribution box suitable for piano switch (5/6 Amp) suitable for desert cooler complete all as specified and directed.
88Supply only of sprinkle pipe, PVC heavy duty 15 mm dia with tee, elbow etc. for 24"/18" sweep desert cooler complete all as specified and directed.
89Supply onlyofPVC distributor suitable for 15 mm dia PVC Pipe, PVCelbow & connection of PVC pipe from pump to distributor suitable for 18"/24" sweep desert cooler complete all as specified and directed.
90Supply Onlyof PVC connection 15 mm dia with brass ferule both and length 600 mm complete all as specified and directed.
91Supply only of PTMT float valve , 15 mm dia complete all as specified and directed(Make Prayaga)
92Supply only of copper conductor twin core PVC insulated and sheathed cable size 1.50 sqmmISI mark for pannel wring of desert cooler complete all as specified and directed.
93Supply only of copper conductor three core PVC insulated and sheathed cable size 1.50 sqmmISI mark for pannel wring of desert cooler complete all as specified and directed.
94Supply only of PVC pipe heavy duty 15 mm dia for desert cooler pump to distributor complete all as specified and directed.
95Supply only of replacement submersible pump for desert cooler single phase, 1/40 HP,230volts complete all as specified and directed.
96Supply only of Exhaust fan blades 18"/20" sweep heavy duty(as per sample) complete all as specified and directed.
97Supply only of wood wool pad (As per sample) including wiremesh (jali) suitable for desert cooler325 mm to 500mm sweep complete all as specified and directed.
98Supply only kit fan, motor, minimum 1 inch core, copper winding, less consumption of electricity, more durable, heavy duty, single phase, 230 volt AC, 1/3 HP, complete with blade arm 18"sweep size suitable for desert cooler complete all as specified and directed.
99Supply only exhaust fan motor, single phase, 230 volt AC, 1/3 HP, copper winding less consumtion of electricity, more durable heavy duty complete with blade arm 18"/20"sweep size suitable for desert cooler complete all as specified and directed. (
100Renewal of set of 3 panels made out of PGI sheet24 gauge thick with wood wool pads and wiremesh, in required quantity duly filled complete all as specified and directed.
101Taking out defective burnt exhaust fan offollowing sweep and of any makeand transporting tocontactor"s workshop, opening of exhaust fan/taking out rotor and cutting out the burnt winding and cleaning the slots and rewinding of the same with the existing size of super enameled copper winding wire including insulation varnishing, greasing, reassembling testing and fixing in position 18"/24" size (exhaust fan) complete all as specified and directed.
102Taking out carefully 325 to 500/600 mm sweep desert cooler from its existing position from stand or pillar, removing the side panels, taking out cut wood pads or loose pads and disposed to a distance not exceeding 50 metres away as directed by EIC and spray painting with synthetic enamel paint of approved color (inside and outside) including one coat of black japan paint in side the base of tank tank after preparation of old painted surfaces and reassembling and fixing in positioncomplete all as specified and directed.
103M&L for repairing of leakage of tank by brazing/solderingof any size of desert cooler, testing the leakage water complete all as specified and directed.
104Renewal of desert cooler body, suitable for 450 mm/500 mm sweep exhaust fan made out of 24 gauge PGI sheet with front grill, side panel include wood wool pad/ wiremesh set, switch, regulator, flexible cable include plug top complete all as specified and directed.
105M&L for fabrication of GI water storage tank for desert coolerof 18"/24" any makemade out of 24 SWG 10mm apertureincluding rivetting brazing /soldering including painting with two coat of (black) enameled paint over a coat of red oxide primer and installed at locations complete all as specified and directed.
106Dismantling of existing repairable water coolerof any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts, reassembling andinstallation of the same on same location and making electric connection etc. to make it fully functional complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
107Supply only ofCP pipe connectorincluding flange, screw, CP nozzle of nipple, female nozzle and extentioncomplete all as specified and directed
108supply only of blower motor with bladeAC 240 volts, 50 HZ single phase, of 1/10 hp capaciitescomplete all as specified and directed.
109Supply only of blower motor with bladeAC 240 volts, 50 HZ single phase, of 1/16 hp capaciitescomplete all as specified and directed.
110Supply only of blower motor with bladeAC 240 volts, 50 HZ single phase, of 1/8 hp capaciitescomplete all as specified and directed.
111Supply only of aluminium fan blade of blower motor of 1/16 HP complete all as specified.
112Supply only ofPVC fan blade of blower motor of 1/8 or 1/10 HP complete all as specified.
113Supply and fix in repaircondensing coil for 150 litres Capacity water cooler of any make all as specified and directed by Engineer-in-Charge.
114Supply and fix in repaircondensing coil for 60/120 litres Capacity water cooler of any make all as specified and directed by Engineer-in-Charge.
115Supply and fix in repaircondensing coil for 40/80 litres Capacity water cooler of any make all as specified and directed by Engineer-in-Charge.
116Supply onlyCP Brass push cock(inner or outer threaded) of 15 mm bore size completeall as directed by the Engineer-in-Charge.
117Supply only of 32 mm PVC pipe with clip and strainer tee Elbow all as specified and directed by Engineer-in-Charge.
118Supply only of starting relay for 1 TR water cooler complete all as specified and directed .
119Supply only of starting relay for 1/3 TR water cooler complete all as specified and directed .
120Supply only of runnuing capacitor (conforming to IS:2993 - 1975) AC 230 volts in plastic container 6 mfd complete all as specified and directed .
121Supply only ofcapacitor for blower motor of water cooler of 2.5 Mfd capacity all as specified and directed
122Supply onlyof capacitor for blower motor of water cooler of 4.00 Mfd capacity all as specified and directed
123Supply only of running capacitor(conforming to IS:2993 - 1975) AC 440 volts in plastic containerof 10 mfd capacities complete all as specified and directed.
124Supply only of overload protector for 1.00 TR compressor complete all as specified and directed .
125Supply only of overload protector for 1/3TR compressor complete all as specified and directed .
126Supply only of Thermostat long tail for water coolercomplete all as specified and directed by Engineer-in-Charge .
127Supply only of Thermostat short tail for water coolercomplete all as specified and directed by Engineer-in-Charge.
128Supply only of gas filter, flare type, 3/"x 1/2" flare, all as specified and directed by EIC.
129Supply only offloat valve , 15 mm bore of brass with nipple and polyethylene float ball complete all as specified.
130M&L for disconnecting of water cooler of 150 litres capacities from its position, taking out water from its water tank, cleaning of water tank by washing with washing powder and with fresh water externally and internally andspray painting with synthetic enamel paint of approved tint/colour to all painted surface of water cooler of following capacities after preparation of old painted surfaceswithout disturbing the components & wiring etc. complete and reconnceting complete all as specified and directed.
131All as per item No 130 above but for 40 / 80 Litres capacities of water coolers
132All as per item No 130 above but for 60 / 120 Litres capacities of water coolers
133Checking of leakage in refrigerant system of water cooler of 150 litrescapacity by putting nitrogen under pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuumising the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
134Checking of leakage in refrigerant system of water cooler of 60/120 litrescapacity by putting nitrogen under pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuumising the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
135Checking of leakage in refrigerant system of water cooler of 40/80 litrescapacity by putting nitrogen under pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuumising the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
136Transporting defective blower motor of 1/ 16 HP capacities from AGE E/Myard to contractor"s workshop, dismantling the burnt winding & rewinding of blower motor with the existing size super enameled copper winding wireincluding insulation, varnishing, greasing, testing and transporting back to AGE E/M yard for refixing at the site complete all as specified and directed.
137All as per item No 136 above but for capacity of 1/8 HP
138Dismantling of unserviceable compressor of any make/brand from water cooler including disconnecting suction / Discharge copper tubing andSupply&fixing new compressor(sealed unit) with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas matching with R-22, of 1 TR Capacity ( Make Emmerson Model HR-13) or equivalent of other specified make& Modelcomplete all as specified and directed. Note : Refrigerant gas will be provided by contractor.
139Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,compressor rubber grooves and refixing it including N2 flashing and charging of refrigerent with non CFC refrigerant gas matching with R-22 in required quantities and testingof 120/150 litres capacities of water coolers complete all as specified and directed by Engineer-in- Charge.(Make Make Emmerson Model KCJ 34) Note : Refrigerant gas will be provided by contractor.
140Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,compressor rubber grooves and refixing it including N2 flashing and charging of refrigerent with non CFC refrigerant gas matching with R-22 in required quantities and testingof 40/80 litres capacities of water coolers complete all as specified and directed by Engineer-in- Charge.(Make Make Emmerson Model KCJ 444). Note : Refrigerant gas will be provided by contractor.
141Dismantling of existing repairable refrigerator any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts, reassembling andinstallation of the same on same location and making electric connection etc. to make it fully functional complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
142Supply only starting relay, open type for refrigerator of capacity 165/300/310 litres complete all as specified and directed.
143Supply onlyover load protector for 1/6 HP refrigerator of capacity 165/300/310 litres complete all as specified and directed.
144Supply onlythermostat defrost type for refrigerator complete all as specified and directed.
145Supply onlys thermostat non defrost type for refrigerator complete all as specified and directed.
146Supply only Fan motor with blade of Refrigerators suitable for any make/ model & capacities complete all as specified and directed.
147Supply only Tharmal fuse of Refrigerators suitable for any make/ model & capacities complete all as specified and directed.
148Supply only Timer of Refrigerators suitable for any make/ model & capacities complete all as specified and directed.
149Supply only Bimetal of Refrigerators suitable for any make/ model & capacities complete all as specified and directed.
150Supply only Door switch of Refrigerators suitable for any make/ model & capacities complete all as specified and directed.
151Supply only lamp of Refrigerators suitable for any make/ model & capacities complete all as specified and directed.
152Supply only Defrost Heater of Refrigerators suitable for any make/ model & capacities complete all as specified and directed.
153S&F in reapairPCB for 300/310 ltr refrigerators, complete all as specified and directed. (Make-Samsung/LG or others as required)
154S&F in repair PCB for 300/310 ltr refrigerators (Inverter type), complete all as specified and directed. (Make-Samsung/LG or others as required)
155M&L for dismantling of defective PCB of Refrigerator any make, model and capacity and transporting to contractors workshop for repair of the same,transporting back to site & refixing to Refrigerator to ensure proper functioning of the AC complete all as specified and directed.
156M&L for dismantling of defective PCB of Refrigerator Inverter type any make, model and capacity and transporting to contractors workshop for repair of the same,transporting back to site & refixing to Refrigerator to ensure proper functioning of the AC complete all as specified and directed.
157Renewal of Refrigerator body, capacity 190 Ltrwith front door, cooling coil, freezer and internal accessories include flexible cable include plug top complete all as specified and directed. Make ;- Whirlpool/ LG/ Godrej/Samsung.
158S&F in repair Freezer for capcity 165/180/210 ltrs complete all as specified and directed. (Make-Samsung/LG or others as required)
159S&F in repair Freezer for capcity 300/310 ltrs complete all as specified and directed. (Make-Samsung/LG or others as required)
160M&L for disconnecting of Refrigerator of various capacities from its position, cleaning by washing with washing powder and with fresh water externally and internally andspray painting with synthetic enamel paint of approved tint/colour to all painted surface of Refrigerator after preparation reconnceting and to make it fully function complete all as specified and directed.
161S&F condensing coilof 165/190/195 litres capacitiesrefrigerator by disconnecting condensing coil from refrigerator, N2 pressure testing and flushing out the system and charging ofNon CFC gas as per required quantity and testing complete all as specified and directed. Note : Refrigerant gas will be provided by contractor.
162All as per item 161 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators
163Checking of leakage in refrigerant system ofrefrigerator of 165/190/195 litrescapacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
164Checking of leakage in refrigerant system ofrefrigerator of 286 /300/310 litrescapacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
165Renewal of Refrigerator body, capacity 240 Ltrwith front door, cooling coil, freezer and internal accessories include flexible cable include plug top complete all as specified and directed. Make ;- Whirlpool/ LG/ Godrej/Samsung.
166Taking down unsv compressor from the regrigerator and Supply and fixing new sealed unit compressor suitable for 165/190/195 litres refrigerator ( 1/8 TR) capacities , charging with gas and making connections and testing complete all as specified and directed by Engineer-in- Charge. Make- LG/Whirlpool/Samsung/Godrej). Note : Refrigerant gas will be provided by contractor.
167Description all as per item 166above but for capacity of 240/286/300/310 ltrs (1/6 TR) refrigrators.(Make-LG/Whirlpool/Samsung/Godrej)
168Dismantling of existing repairableDeep freezer any make and capacity from its position after disconnecting electric connections, for carrying out repairs and renewal/ replacements of Parts, reassembling andinstallation of the same on same location and making electric connection etc. complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
169Supply onlystarting relay for 200 Ltr. Capacity deep freezer complete all as specified and directed.
170Supply only starting relay for 300 Ltr. Capacity deep freezer complete all as specified and directed.
171Supply only over load protector suitable for 200/300 Ltr deep freezer complete all as specified and directed.
172Supply only running capacitor for deep freezer any make and capacities complete all as specified and directed.
173Supply only thermostate suitable for 200/300 Ltr. Capacity deep freezer complete all as specified and directed.
174Supply only starting capacitor for deep freezer any make and capacities complete all as specified and directed.
175Taking down defective compressor of following capacity of deep freezer of any Make and depositing ,supply andfixing sealed unit compressor as specified here underincluding brazing and with necessary nuts and bolts, copper filter, capalary and supply & charging of refgn Gas Non CFC in required Qty and testing 200 Litres capacity deep freezer compressor Model No. KCN 372 of Kirloskar complete all as specified and directed. Note : Refrigerant gas will be provided by contractor.
176All as per item No above 175 but 300 Litres capacity deep freezer compressor Model No. KCN 411 of Kirloskar
177Checking of leakage in refrigerant system of deep freezer of 200 / 300 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
178Renewal of Fan Motor with blade of deep freezer, 230Volts rating, AC, Single Phase, 50 Hzincluding disconnection and reconnecting and testing complete all as specified and directed.
179M&L for taking down unserviceable voltage stablizers ofany make of following capacities and dismantling the stablizers of any size for repair of the defective parts/spares & ressembling including repairs of defective screws, rubber shose testing and after repair refixing the same at existing location complete all as specified and directed Note:- Spare parts measured and paid seprately
180Supply only relay 25/30 Amps 24 volts for 4 KVA/5KVA voltage stablizers complete all as specified and directed
181Supply only main PCB with high & low voltage cut off suitable for 4 KVA/5 KVA voltage stablizers of any make complete all as specified and directed
182Supply only Relay PCB with high & low voltage cut off suitable for 4 KVA/5 KVA voltage stablizers of any make complete all as specified and directed
183Supply only 2 mtr long copper cable 3 core PVC insulated and sheathed 80/.20(2.5 Sqmm) size duly fitted with 3 pin top 20 Amps all as specified and directed
184Supply only power transfromers suitable for voltage stablizers of capacity 4/5 KVAall as specified and directed
185Supply only AC volt meter square/round type 0-300 volts suitable for 5/4 KVA single phase voltage stablizers complete all as specified and directed
186supply and fix in repair of dimmer type transfromer for 4KVa/5KVA Voltage stablizers all as specified and directed by EIC
187Supply and fix in repair Polycarbonate Plug top 3 pin 5/6 Amp complete all as specified and directed.
188Supply and fix in repairPolycarbonate Plug top 3 pin 16 Amp complete all as specified and directed.
189Dismantling of unserviceable compressors of3 TRcapacitiesincluding disconnecting suction / discharge copper tubing and S&F compressor scrolltype with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushingby nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii)The electrical accessories required will be measured and paid for separately. (
190Dismantling of unserviceable compressors of4 TRcapacitiesincluding disconnecting suction / discharge copper tubing and S&F compressor scrolltype with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushingby nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i) Refrigerant gas will be provided by contractor (ii)The electrical accessories required will be measured and paid for separately.
191Dismantling of unserviceable compressors inverter type of 1.5 TRcapacitiesincluding disconnecting suction / discharge copper tubing and S&F new compressor rotary inverter typetype with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushingby nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note : (i) Refrigerant gas will be provided by contractor (ii)The electrical accessories required will be measured and paid for separately.
192M & L for servicing of Split AC,s 8.5 TR Indoor/out door unit by means of electric blower & water under pressure,cleaning & washing of cooling/condencing coilby soap solution or recommended chemical ,oiling & greasing of moving parts such as blower motor etc completeall as specified and directed by EIC. Note :- Parts renewed shall be measured and paid separately under appropriate items
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail