Tender For Day To Day Maintenance And Repair Such As Switch Board, Switches, Mcb Obs, Led Tube Light Fittings, Post Top Lantern Fittings, Street Lights, Security Lights, Gate Lights, Frp Junction Boxes, Electric Geysers, Air Circulators, Ceiling Fans, panvel-Maharashtra

Military Engineer Services-MES has published Tender For Day To Day Maintenance And Repair Such As Switch Board, Switches, Mcb Obs, Led Tube Light Fittings, Post Top Lantern Fittings, Street Lights, Security Lights, Gate Lights, Frp Junction Boxes, Electric Geysers, Air Circulators, Ceiling Fans. Submission Date for this Tender is 13-02-2024. Electrical Maintenance Tenders in panvel Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

41596691
Corrigendum : Tender For Day To Day Maintenance And Repair Such As Switch Board, Switches, Mcb Obs, Led Tube Light Fittings, Post Top Lantern Fittings, Street Lights, Security Lights, Gate Lights, Frp Junction Boxes, Electric Geysers, Air Circulators, Ceiling Fans
Open Tender
Indian
Maharashtra
panvel
13-02-2024

Tender Details

Day To Day Maintenance And Repair Such As Switch Board, Switches, Mcb Obs, Led Tube Light Fittings, Post Top Lantern Fittings, Street Lights, Security Lights, Gate Lights, Frp Junction Boxes, Electric Geysers, Air Circulators, Ceiling Fans, Exhaust F

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-02-2024
2 08-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 48600.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: DAY TO DAY MAINTENANCE AND REPAIRS SUCH AS SWITCH BOARD, SWITCHES, MCB, MCB DBs, LED TUBE LIGHT FITTINGS , POST TOP LANTERN FITTINGS, STREET LIGHTS, SECURITY LIGHTS, GATE LIGHTS, FRP JUNCTION BOXES, ELECTRIC GEYSERS, CEILING FANS, EXHAUST FANS, ETCAT POWAI,WORLI, CG MALAD , CGSD MANKHURD AND PANVELUNDER GE DAMAN.
Sl. No. Item Description
1Taking down carefully copper/ aluminium point wiring (light ,fan ,socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets ,light fittings etc. Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc to match with the existing surface / location.all as directed.
2M&L for point wiring with 1.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed FRLS cable, ISI marked 1100 volts grade draw through and including rigid non metallic PVC casing and caping ( of suitable size) and all necessary fittings accessories fixed on walls/ceilng etc including 1.5 sqmm single core PVC insulated unsheathed cable (green colour) 1100 volts grade with multi stranded copper conductor earth continuity conductor to commom earth and connected to earth continuity conductor to common earth and connected to earth dolly terminated in and including sunk pressed steel terminal box for modular plate and including modular plate complete including cutting chases, refilling and making good to disturbed surfaces all as specified and as directed, for one light/fan/bell point controlled by one switch.
3All as per item no. 2 here in beforbut for One three pin switch socket outlet 5 amps on same board.
4All as per item no. 2 here in before but for One three pin switch socket outlet 5 amps on independent board.
5All as per item no. 2 but for two way light point wiring controlled with two 2 way 5 amps switches
6M&L for point wiring using proper colour coding complete all as specified with 1100 Volts grade, 2.5 Sqmm PVC insulated, FRLS, unsheathed, wire confirming to IS-694,PartII, ISI marked with Multistranded copper conductor in and including PVC casing caping (suitable size ) ISI marked ,with all accessaries on wall/ceiling/floor/ roof etc, sunk pressed steel terminal box not less than 2 mm thick, 50 mm deep, covered with 3 mm thick plastic laminated, ISI marked, sheet top cover fastened with chromium plated brass screw including 2.5 Sqmm, PVC insulated, FRLS, unsheathed, multistranded, copper conductor 1100 Volts grade, green colour, continuous earth wire connected to common earth doly for 15 Amps, 3 Pin, socket outlet independent all as specified and directed.
7Supply and fix in repair LED tube lightfitting 1X 20 Watt including LED light 20 watt,complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of 0.75 Sqmm size and PVC square block for fixing LED tube fitting complete all as specified and directed. Make:-HalonixBajaj/Philips/ CG
8Supply and fix in repair LED tube lightfitting 1X 10 Watt including LED light 10 watt,complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of 0.75 Sqmm size and PVC square block for fixing LED tube fitting complete all as specified and directed. Make:-HalonixBajaj/Philips/ CG
9S & F modular socket5 Amps 2 module,2/3 pinISI marked, 240 Volts, all as specified and directed.
10S & F modular socket 6/16 Amps and 2/3 pin, 2 modules ,ISI marked 240 Volt , completeall as specified and directed.
11S & Fmodularswitch, single pole, ISI marked ,one way 6 Amps 1 module 250 volts , completeall as specified and directed.
12S & Fmodular switch 15 amps ,ISI marked, flush type, multipurpose1way ,I module , completeall as specified and directed.
13S & Fmodular type fan regulator, 230 volts, ISI marked , stepped and flush type and connecting up complete all as specified and directed.
14S&F in repair switch modular type,5 amps, 2 ways, ISI marked, 250 volts , complete all as specified and directed.
15S & Fmodular bell push , 1 module ,6 Amps , ISI marked,250 volts , complete all as specified and directed. Make for item No:- 9 to 15 -Anchor Roma/ Crabtree/Legrand
16S & Ffan regulators,230 volts, ISI marked, stepped and flush type and connecting up , complete all as specified and directed.
17S&F Switch piano , flush type ,single pole, ISI marked ,one way 5 Amps ,230 volts, complete all as specified and directed.
18S&F in repair bell push, flush button , single pole ,ISI marked, one way 5 Amps, 230 volts , complete all as specified and directed.
19S&F in repair switch socket combination 2 in one, 5 Amps flush type ISI marked 240 Volt all as specified.
20S&F in repair Socket 5 Amp flush type piano, 2 module , 3 pin flush type ISI marked 240 Volts all as specified and direcetd.
21S&F in repair switch socket combination, ISI marked flush type, multipurpose 5/15 amps , controlled by one switch , complete all as specified and directed.
22S&F in repair ceiling rose,3 phase/PVC/polycarbonate isolated body, ISI marked, complete all as specified and directed. Make for item No:- 16 to 22 Anchor/Legrand/Havells
23S&F in repair bell ding dong AC 230 Volts, ISI markedsingle pole all as specified.
24supply and fix newwhite cover modular plate with frame of 8 module alll as specified.Make for Item No-24 to 27 :- Anchor Roma/Crabtree/Legrand
25supply and fix newwhite cover modular plate with frame of 6 module all as specified.
26supply and fix newwhite cover modular plate with frame of 3 module all as specified.
27Supply and fixing modular white cover plate with frame 4 module
28supply and fix newwhite cover modular plate with frame of 12 module alll as specified.
29Supply and Fixing Modular PVC rectangular blockfor mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet suitable for 3 module white cover plate.
30Supply and Fixing Modular PVC rectangular blockfor mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet suitable for 4 module white cover plate.
31Supply and Fixing Modular PVC rectangular blockfor mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet suitable for 6 module white cover plate.
32Supply and Fixing Modular PVC rectangular blockfor mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet suitable for 8 module white cover plate.
33Supply and Fixing Modular PVC rectangular blockfor mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet suitable for 12 module white cover plate.
34Taking down old unserviceable MCCB 63 amp and supply and fix newMCCB,415 volt,3 pole 16 KA capacity, 63 Amps, complete all as specified and directed. Make : Siemens /Havells /Legrand/L & T .
35Supply & fix in repair MCB DP 40 Amps,10 KA,240 volts complete all as specified and as directed.
36Taking down old unserviceable MCB TPN 63 amp and supply and fix newMCB,TPN, 63 Amp, 415 Volt, 50 HZ, 10 KA, `C` Series, ISI marked, making electrical connection with the help of Lugs/thimbles all as speacified. Make :Havells/L&T/Siemens/Legrand .
37Taking down old unserviceable MCB SPN 6-32 amp and supply and fix newMCB,SPN, 6-32 amp, 240 Volt, 50HZ, 10 KA, `C` Series, ISI marked making electrical connection with the help of Lugs/thimblesall as speacified. Make :Havells/L&T/Siemens/Legrand .
38Taking down old unserviceable MCB SP 6-32 amp 240 volt and supply and fix newMCB,SP, 6-32 amp, 240 Volt, 50HZ, 10 KA, `C` Series, ISI marked making electrical connection with the help of Lugs/thimbles ,complte all as speacifiedand directed. Make :Havells/L&T/Siemens/Legrand . Make Item No 34 to 39 :-Standard/L&T/ Legrand/Schneider/Havells/Siemens ISI Marked
39S&F vertical TPN DB Box with MCCB Incomer, metal door, IP-43 , 6 Way with MCCB 150 Amps as incomer and remaining 18 modules as outgoing for mcb Sp, MCB SPN, MCB TPN, the DB box should be duly concealed inside the wall surface, this includes removal od old U/s MCCB Box and securing the rwmoved wiring connection with help of cable tie and lugs for serviciable MCB"s or new MCB"s complete in all respect along with making any disturbed surface good all as directed by engineer-in-charge.Note- Price for MCCB 150 Amps as incomer is deeemed to be inclusive in quoted rates.
40Supply and fix in repairs MCB distribution board TPN 4 way , double door 415 volts duly painted with epoxy based powder coated painting suitable for mounting MCB TP/FP as incomer of rating upto 63Amps, FP and MCB SP /TP as outgoings complete with 200 amps rated busbar, neutral bar, earth bar connecting cable links with top and bottom removable gland platewithIP 42 protection including removing old unserviceable item all as specified and as directed.Make:-Standard/ Legrand/Schneider/Havells/Siemens
41Supply and fix in repairs MCB distribution board SPN 8 way 240 volts, double door withIP 42 protection duly painted with epoxy based powder coated painting suitable for mounting MCB DP/SPN as incomer and MCB SP/DP as outgoings complete with 200 Amps rated busbar, neutral bar, earth bar connecting cable links with top and bottom removable gland plate including removing old unserviceable item complete all as specified and as directed. Make:-Standard/ Legrand/Schneider/Havells/Siemens
42Taking down old unservicable MCB, DB SPN 4 way and supply and fix newMCB, DB,SPN, 240 V double door, IP-42, 4 Way, ISI marked having earth terminal, Neutral bus terminal for 8 way circuits complete in all respect Concealed in wall including making electrical incoming and outgoing connection with legs/thimbles all as speacified and directed. Make:-Standard/ Legrand/Schneider/Havells/Siemens
43Material and labour for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi strandedduly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable item complete all as specified and directed. Note : -02 run of 6 sqmm single core copper conductor cable and 01 run of 4 sqmm single core copper conductor and 01 run of PVC casing and caping shall be measured as one unit.
44Material and labour for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi strandedduly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 2.5 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable itemcomplete all as specified and directed. Note : -02 run of 4 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable and 01 run of PVC casing and caping shall be measured as one unit.Make for item No 43 & 44 :-(i) copper cable:-Havells/Finolex/Plaza /Polycab (ii) PVC casing/caping:-Press fit/classic/precision/supreme
45Taking down old unserviceable cable 3 core 2.5 sq mm and supply and fix new1100 volt grade cable PVC insulated 3 core 2.5 sq mm multistranded copper conductor , complete all as per specified and directed. Make : KEI/Havells/Polycab
46Taking down old unserviceable cable 3 core 1.5 sq mm and supply and fix new1100 volt grade PVC insulated multistranded copper conductor , complete all as per specified and directed. Make : KEI/Havells/Polycab
47S & F in repair slimsurface mounted LED panel 2"x2" fitting aluminium die cast body with premium diffuser to ensure glare free and even distribution of light 36 watts LED, 6000K , including all necessary connections , completeall as specified and directed. Make : Havells / Halonix/ Bajaj /philips/Wipro.
48Supply and fix LED post top lantern light fitting 40 watt made in die cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP65 protection complete with all accessories including fixing arrangement on boundary wall pillar by providingGI pipe top on surface of boundary wall of suitable size and lengthas per site requirement and making good the disturbed portion ofcompound wall to match with existing surface completeall as specified and directed. Make :- Halonix/ Havells/Philips/Bajaj/crompton
49Taking down old unserviceable ceiling light fittings and supply and fix newLED Ceiling light fitting, recess mounting/surface mounting 36 watt, ISI marked,white powder coated CRCA housing with highpower LEDs, aluminium front frame with flat acrylic cover white high transmission .Make :Bajaj/Havells/Philips/Wipro with all connected accessories complete all as specified and directed.
50Taking down old U/S LED lamp holder and supply an fix in new lamp holder with angular meta ring with heavy duty brass contactsuitable for 9/12/15/20 watt LED bulbs complete all as specified and directed.
51Taking down old U/S round type LED fittings and supply and fix in new LED round type light fitting 15 W, 240 V complete all as specified and directed.
52Taking down old U/S Square8 x8 inch LED fittings and supply and fix in new LED 8 x 8 squaretype light fitting 15 W, 240 V complete all as specified and directed.
53Taking down old u/sLED Square 4 x4 , 6 Watt and supply and fix in new led square type fitting 6 W, 240 V complete all as specified and directed.
54Taking Down old U/s FRP junction Boxes and supply and fix in new junction boxes including MCB SP 6-10 Amp,with proper claming attachment complete all as specified and directed.
55Supply only fan capacitor 2.25/2.5 mfd, 240 volts, 50Hz complete all as specified and directed. Make :- Epcos / Havells or equivalent
56Taking down carefully existing unserviceable wall mouted fans of any sweep and make models type after disconnecting and taking out burnt copper winding from wall mounted fan motor and rewinding the same with new super enamelled copper wire of similer gauge and number of turns as exists for full speed,including cleaning and greasing of bearing/ bushes taping ,varnishing and replacement of defective parts and reassembling of fan and refixing after testing complete to the satisfaction of Engineer-in -Charge.
57Cutting the existing surface wall of brick/ stone masonary and making round hole at any height including providing anchoring stud in wall for fixing of exhaust fan and making good the disturbed surface area to match with existing surface complete all as specified and directed.
58Removing old unserviceableblade assembly fromexhaust fanand supply and fix new blade assembly suitable for exhaust fan upto 300 mmsweep andincluding locking nuts and testing complete all as specified and directed.
59Taking down storage type electric water heater (Geyser)25 Ltrs capacity of any make/model/type from existing wall after disconnecting of electric connection and water pipe connections for carrying out repairs and replacement of unserviceable spare parts/ components such as heating element, thermostat, pilot lamp, insulating glass wool, thermal cut out, pressure release valve, safety valve, aperature plate assembly etc and making water tightness of inner storage tank and renewal of rubber washer/ gasket and nut, bolts and washers etc and assembling all parts/ accessories and adjust to required range of thermostat control including fixing back in same location and makingwater pipe connections and cable connections and testing for its satisfatory functioning complete all as specified and directed.Note:-(i) Spares/ components will be measured and paid separately under relevant item of schedule as supply only (ii) Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate.
60Supply only heating element of 2.0 KW suitable for storage type water heater (geyser)
61Supply onlythermostat adjustable type suitablefor storage type water heater (geyser) suitable for existing type and any capacity complete all as specified and directed.
62Supplyonlythermal cut out storage type water heater(geysers) suitable for existing type and any capacitycomplete all as specified and directed.
63Supply only pressure release valve suitable for storage typewater heater(geysers) of any capacity complete all as specified and directed.
64Supply onlygeyser indicator pilot lamp(red and green colour) prewired in round/square/rectangle shape suitable for geysers of any type complete all as specified and directed.
65Supply and fix PVC connection pipe15 mm dia, 450mm long with end nuts and washer suitable for hot water outlet of geyser inlcuding removing old unserviceable item completeall as specified and directed.
66Supply and fix PVC connection pipe15 mm dia, 450mm long with end nuts and washer suitable for cold water inlet of geyserinlcuding removing old unserviceable item completeall as specified and directed.
67Supply and fix stop valve 15 mm dia, cast copper alloy chromium plated with crutch handle screwed both ends for GI pipe/fittings inlcuding removing old unserviceable item complete all as specified and directed
68Supply and fix sheet metal enclosure with two pin and earth plug and socket including MCB SP 20 Amp,10KA,"C" seriesinlcuding removing old unserviceable item complete all as specified and directed. . Make:-Indo Asian/Standard/L&T/ Legrand/Schneider/Havells/Siemens ISI Marked
69Material and labour for painting to storage type water heater(Geyser)of capacity 25litre of any make/type to completeexternal body with two coat of synthetic enamel paint similar to match withexisting colour after preparation of surfaces including marking MES Number with black paintcomplete all as specified and directed directed.Make of paint:-Asian/Berger/Nerolac Note:-Painting work to be carried out after dismantling of storage type water heater(geyser)
70Taking down ceiling fan1200 mm sweep to 1400 mm sweep of any make from its existing position after disconnecting of electric connection for carrying out repairsincluding servicing, overhauling, greasing etc after cleaning the body internally and externally with cleaning agent including renewal of minor spare parts such as split pins, cater pins, coupling bolt, capacitor holder, terminal adoptor, screws, nuts and washers etc and replacement of spare parts/accessories such as ball bearings, gun metal bushes, capacitor, canopy top and bottom, shackle clip assembly, rewinding of fan motor, painting and including hanging/ fixing back in existing location and making cable connections and testing for its satisfactory performance inclusive of all complete all as specified and directed.
71Taking down exhaust fans 250 mm sweep to 300 mm sweep of any make from any height after disconnecting of electric connection for carrying out repairs including servicing, overhauling, greasing etc after cleaning the body internally and externally with cleaning agent and renewal of minor spare parts such as split pins,cater pins, capacitor holder, terminal adoptor, nuts, bolts and washers etc and replacement of components/accessories such as ball bearings, gun metal bushes, capacitor, rewinding of fan motor including fixing back in existing location and making cable connections and testing for its satisfactory performance inclusive of all complete all as specified and directed.
72Supply onlyball bearingMake:- SKF Cat No 6201/ 6202 or equivalent in NBC/NRB
73Supplyonly gun metal bush suitable for ceiling fan/ Exhaust fanof any sweepcomplete all as specified and directed.
74Supply only shackle clip assembly with rubber bush reel and nuts, bolts and washers suitable for ceiling fan of any sweep complete all as specified and directed.
75Supply only PVC canopy top and bottom with tighten screwsuitable for ceiling fan of any sweepcomplete all as specified and directed.
76Supply and fix galvanised louvre shutter suitable for exhaust fan 250mm to 300mm sweep and fixing arrangement at out side of wall surface at any height complete all as specified and directed.
77Supply and fix down rodmade of MS pipe medium grade 15mm dia of 450 mm long duly drilled holes both ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and painting to of down rodwith two coat of synthetic enamel paintover one coat of red oxide primer complete all as specified and directed.
78Supply and fix down rodmade of MS pipe medium grade 15 mm dia of 600 mm long duly drilled holes both ends and slot with hole in other end suitable for fixing of ceiling fan of any sweep and painting to down rodwith two coat of synthetic enamel paintover one coat of red oxide primer complete all as specified and directed.
79Material and labour for painting to ceiling fan of any sweep complete body, blades and down rod with two coat of synthetic enamel paint similar to match with existing colour after preparation of surfaces including marking of MES Number with black paint complete all as specified and directed directed.Make of paint:-Asian/Berger/Nerolac
80Material and labour for painting to exhaust fan complete body, blade assembly, frame of 250 mm sweep to 300 mmsweep withtwo coat of synthetic enamel paint similar to match with existing colourafter preparation of surfaces including marking of MES Number with black paint complete all as specified and directed directed.Make of paint:-Asian/Berger/Nerolac
81Taking down old unserviceable street light fittings and supply and fix newLED street light fitting,120 watt, IP-65/66, ISI marked,white powder coated CRCA housing with highpower LEDs, aluminium front frame with flat acrylic cover white high transmission .Make :Bajaj/Havells/Philips/Wipro with all connected accessories complete all as specified and directed.
82Taking down old unserviceable security lightfittings and supply and fix newLED street light fitting, 35watt, IP-65/66, ISI marked,white powder coated CRCA housing with highpower LEDs, aluminium front frame with flat acrylic cover white high transmission .Make :Bajaj/Havells/Philips/Wipro with all connected accessories complete all as specified and directed.
83M& labour for fault finding in main line/submain line/wiring circuit and after detection including repais needed thoroughly making the disturbed surface good all as per directions of Engineer-in-charge. Note : items needed for fault rectification will be paid saparetly from the respective items. Note : Contractor supervisor to report on daily basis to the concerned JE as detailed by the Engr-in-Charge on daily basis to collect the complaints in morning by 9.15 am on working days, supervise the work and again report to AGE/JE in evening by 4.45 pm to submit the progress and details. In case of absence of supervisor penalty will be imposed at the rate of Rs.1200 per day.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail