Tender For Provision Of Lt Ug Cable From L And T Power House To Control Office Amn Sub Depot Of Cod And Provn Of Borewell With 5 Hp Three Phase Motor And Plumbing Of 1000M Of 506 Abw Under Age Em Of Ge (East) Jabalpur, jabalpur-Madhya Pradesh

Military Engineer Services-MES has published Tender For Provision Of Lt Ug Cable From L And T Power House To Control Office Amn Sub Depot Of Cod And Provn Of Borewell With 5 Hp Three Phase Motor And Plumbing Of 1000M Of 506 Abw Under Age Em Of Ge (East) Jabalpur. Submission Date for this Tender is 01-02-2024. Motor Work Tenders in jabalpur Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41596098
Corrigendum : Tender For Provision Of Lt Ug Cable From L And T Power House To Control Office Amn Sub Depot Of Cod And Provn Of Borewell With 5 Hp Three Phase Motor And Plumbing Of 1000M Of 506 Abw Under Age Em Of Ge (East) Jabalpur
Open Tender
Indian
Madhya Pradesh
jabalpur
01-02-2024

Tender Details

Tender For Provision Of Lt Ug Cable From L And T Power House To Control Office Amn Sub Depot Of Cod And Provn Of Borewell With 5 Hp Three Phase Motor And Plumbing Of 1000M Of 506 Abw Under Age Em Of Ge (East) Jabalpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 96700.0 /-
Tender Value
INR 48.30 Lakhs /-

BOQ Items

Name of Work : PROVN OF LT UG CABLE FROM L&T POWER HOUSE TO CONTROL OFFICE AMN SUB DEPOT OF COD AND PROVN OF BOREWELL WITH 5 HP THREE PHASE MOTOR AND PLUMBING OF 1000M OF 506 ABW UNDER AGE E/M OFGE (EAST) JABALPUR
Sl. No. Item Description
1M&L for excavation in trenches for laying of cables, poles and stay in any type of soil n.exc1.5 mtr wide and n.exc 1.50 mtr deep and getting outin soft/loose soil complete all as specified and dirtected.
2M&L for returning & filling in, including spreading and leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and dirtected.
3M&L for removing excavated materials (soil) n.exc 50 m and depositing where directed at a level n.exc 1.5m above the srarting point complete all as specified and dirtected.
4M&L for unwashed sand cushioning to under ground cable provided with a layer of 8 cm deepbefore laying and 15 cm covering above the top edge of cable after laying including gently punning complete all as specified and dirtected.Note : Measurement shall be done after puning down of sand.
5Supplyingand laying unreinforced precast cement concrete cable covers, Class LV, Type - 1 Flat, size 250mm x 150mm x 40 mm in trenches for cable protection, embossed with "LT 1100 Volts Electric" on the top surface complete all as specified and as directed.
6Demolition of cement concrete unreinforced in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
7M&L for PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in coping of pole ect including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and dirtected.
8M&L for PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregate as in filling in surface channels and drains etc complete all as specified and dirtected.
9M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 40 mm dia with all fittings complete all as specified and dirtected.
10M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 50 mm dia with all fittings complete all as specified and dirtected.
11M&L for crossing hole under road/hard stranding for passing cable through GI pipe including GI pipe light grade 80 mm dia with all fittings complete all as specified and dirtected.
12S&F XLPE insulated armoured and PVC sheated heavy duty electric cable with aluminium conductor 1100 Volt grade laid in tranches passing through pipes /ducts including testing complete of following cross sectional area and size.Note- Rate shall be inclusive of cable gland & cable lugs.
1325 Sqmm x 4 Core
1435 Sqmm x 3.0 Core
1535 Sqmm x 3.5 Core
1650 Sqmm x 3.5 Core
1770 Sqmm x 3.5 Core
18240 Sqmm x 3.5 Core
19S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 4 Core XLPE armoured Al conductor cable of size 240 to 300 sqmm indoor/outdoor type complete all as specified and as directed.
20Supply, fabricating and erecting/fixing/installation of outdoor LT panel with projected globe roof for rain water protection (feeder pillar box), CPRI approved outdoor type (approximate size 1500 x 1200 x 600mm), weather and vermin proof suitably ventilated for 440 Volts, 3 Phase 4 Wire system, AC supply, factory made fully compartmentalized made out of 3.15mm thick CRCA steel sheet for load bearing , degree of protectionIP 54 as per IS 2147 of 1962 with pretreatment and powder coated of approved colour, double door with both side opening alongwith locking arrangement, bus bar chamber to accommodate epoxy painted high conductivity Aluminium bus bars of 1200 Amps fixed with colour coated porcelain insulator (01 Set) sleeves including phase indication neon lamps set, danger notice plate, necessary cable connections with suitable size of cable lugs and glands, internal wiring with suitable size copper conductor cable, panel shall be fixed/ mounted on approx 75cm above from ground level on and including suitable size of Base Channel/ Angle Iron or any other section (Zinc metal coated) frame work/ support as per site requirement but not less than of angle iron frame of section 50 x 50 x 6mm including all necessary bolts, nuts and washers etc over and including PCC platform of size not less than 1.80 x 0.80 x 0.75M height (outer dimensions), 0.60M above ground level and 0.15m below ground level in PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregate, foundation 150mm thick and 150mm extending on both sides of PCC platform in PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate including necessary excavation & earth work and plaster/ rendering 15 mm thickin CM 1:4 on all sides of PCC platform upto 15cm below from ground level and two coats of white wash on plastered surfaces including prepration of surfaces etc including testing & commissioning with & including following fixtures/ fittings complete all as specified and directed :- (i)Ammeter of rating (0-200Amps) digital type with selector switch - 01 Set (ii) Volt meter of rating (0-600V) digital type with selector switch - 01 Set Make for Ammeter and Volt meter: AE/ L&T/ Legrand/ ABB as approved by GE.
21(a)INCOMING
22(i)Thermal magnetic and microprocessor release MCCB 630 Amps, 4 Pole, 50 KA with front operated locking device. - 01 Nos Make : Legrand catpart No -422075 , Havells, L&T
23(b)OUTGOING
24(i)Thermal magnetic MCCB 250 Amps, 4 Pole, 415V, 36 KA. Qty- 02 Nos.Make : Legrand cat part No. 420249, Havells, L&T.
25(ii)Thermal magnetic MCCB 200 Amps, 4 Pole, 415V, 36 KA. Qty- 02 Nos.Make : Legrand cat part No. 420248, Havells, L&T.
26(iii)Thermal magnetic MCCB 63 Amps, 4 Pole, 415V, 25 KA. Qty- 01 Nos. Make : Legrand cat part No. 420053, Havells, L&T.
27(iv)Thermal magnetic MCCB 25 Amps, 4 Pole, 415V, 16 KA. Qty- 01 Nos.Make : Legrand cat part No. 420011, Havells, L&T.
28(v) MCB 32 Amps, 2 Pole. Qty- 01 Nos.Make :Legrandcat part No. 408617, Havells, L&T.
29(c) Digital time switchincluding 3 phase power contactor 40 Amps. Make : Legrand cat part No. 412641 & 3 phase contactor 40 A, Code No - 412549, Havells, L&T.Qty - 01 Nos
30(d) (i)Digital Voltmeter 0 - 500 Volts with selector switch - 1 Set.
31(ii)Digital Amperemeter 0 - 200 Amps with selector switch - 1 Set.
32(iii) Indicator Lamp - R - Y - B (Set of three).
33(iv)Frequency meter 40-55 Hz - 01 Nos
34Supply, fabricating and erecting/ fixing/installation of outdoor LT panel with projected globe roof for rain water protection (feeder pillar box), CPRI approved outdoor type (approximate size 900 x 1200 x 600mm), weather and vermin proof suitably ventilated for 440 Volts, 3 Phase 4 Wire system, AC supply, factory made fully compartmentalized made out of 3.15mm thick CRCA steel sheet for load bearing and 2mm thick CRCA steel sheet for non load bearing, degree of protectionIP 54 as per IS 2147 of 1962 with pretreatment and powder coated of approved colour, double door with both side opening alongwith locking arrangement, bus bar chamber to accommodate epoxy painted high conductivity aluminium bus bars of 400 Amps fixed with colour coated porcelain insulator (01 Set) sleeves including phase indication neon lamps set, danger notice plate, necessary cable connections with suitable size of cable lugs and glands, internal wiring with suitable size copper conductor cable, panel shall be fixed/ mounted on approx 75cm above from ground level on and including suitable size of Base Channel/ Angle Iron or any other section (Zinc metal coated) frame work/ support as per site requirement but not less than of angle iron frame of section 50 x 50 x 6mm including all necessary bolts, nuts and washers etc over and including PCC platform of size not less than 1.20 x 0.80 x 0.75m height (outer dimensions), 0.60M above ground level and 0.15m below ground level in PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregate, foundation 150mm thick and 150mm extending on both sides of PCC platform in PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate including necessary excavation & earth work and plaster/ rendering 15 mm thickin CM 1:4 on all sides of PCC platform upto 15cm below from ground level and two coats of white wash on plastered surfaces including prepration of surfaces etc including testing & commissioning with & including following fixtures/ fittings complete all as specified and directed:- (i)Ammeter of rating (0-200Amps) digital type with selector switch - 01 Set (ii) Volt meter of rating (0-600V) digital type with selector switch - 01 Set Make for Ammeter and Volt meter: AE/ L&T/ Legrand/ ABB as approved by GE.
35(a)INCOMING
36(i)Thermal magnetic and microprocessor release MCCB 200 Amps, 4 Pole, 36 KA with front operated locking device. - 01 Nos.Make : Legrand cat part No. 420248, Havells, L&T.
37(b)OUTGOING
38(i)Thermal magnetic MCCB 125 Amps, 4 Pole, 415V, 16 KA. Qty- 02 Nos. Make : Legrand cat part No. 42001656, Havells, L&T.
39(i)Thermal magnetic MCCB 63 Amps, 4 Pole, 415V, 16 KA. Qty- 01 Nos. Make : Legrand cat part No. 420013, Havells, L&T.
40(ii) MCB 32 Amps, 2 Pole. Qty- 01 Nos. Make :Legrandcat part No. 408617, Havells, L&T.
41(c)Digital time switchincluding 3 phase power contactor 40 Amps. Make : Legrand Cat No. 412641 & 3 phase contactor 40 A, Code No. 412549, Havells, L&T.
42(d) (i)Digital Voltmeter 0 - 500 Volts with selector switch - 1 Set.
43(ii)Digital Amperemeter 0 - 200 Amps with selector switch - 1 Set.
44(iii) Indicator Lamp - R - Y - B (Set of three).
45(iv)Frequency meter 40-55 Hz - 01 Nos
46M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground levelconnecting to and including GI steel strip of size 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia medium grade pipe for protection ofGI strip to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR Part-I (2009) including PCC foundation/chamber in mix 1:2:4 type B-1 with angle iron frameCI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for LT Panels). Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
47M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground levelconnecting to and including GI earth wire of size 4.0 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade pipe for protection ofGI wire to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR Part-I (2009) including PCC foundation/chamber in mix 1:2:4 type B-1 with angle iron frameCI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for street light poles). Note :- Earth protection pipe & earthing wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
48Supply and laying 50mm dia pipe galvanized, “medium grade”, including fittings complete all as specified and directed.
49S&F Valves, Sluice, flanged of class 1.6 PN, 50 mm dia complete all as specified and directed.
50S&F gun metal Glove Valve conforming to IS-9338, 50 mm dia complete all as specified and as directed.
51Supply, installation, commissioning and testing CPRI approvedfactory fabricated, floor mounted outdoor type LT feeder pillar box of suitable size fabricated out of 3.15 mm thick CRCA sheet and angle iron 50 x 50 x 6 mm frame and 750 mm above the normal ground level complete factory made totally enclosed dust and vermin proof double door both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from botton with cable glands and gaskets, aluminium bus bar 250 Amps rating (01 Set) fixed on procelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connection of all switches/MCCB"s and Bus bar.Bus bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surface ecternally and internally over a coat of red oxide primer paint including necessary PCC 1:3:6 type C-2as in foundation complete all as specified and directed comprising of the following :-
52(a) INCOMING
53(i)MCCB 3 Pole, 415 V,fixed type, 42 Amps with breaking capacity 16 KA - 01 Nos.
54(b) OUTGOING
55(i)MCB 32 Amps, TPN/FP.Qty - 01 Nos.
56(ii)Thermal mangetic MCCB 32 Amps, TPN/FP pole, 415 V, 25 KA,Qty - 01 Nos.
57(c)(i)Digital Voltmeter 0-500 Volts with selector switch-01 Set.
58(ii)Digital Amperemeter 0-200 Amps with selector switch-01 Set.
59(iii)Indicator Lamp - R - Y - B (set of three) - 01 Nos
60(iv)Frequency meter 40-55 Hz - 01 Nos.
61M&L for 25 mm dia flexible PVC Heavy Duty Garden pipe/ Garden Water Pipe/PVC Pipe/Garden Outdoors Pipes/Hose Connector Long Flexible Pipe for Watering Home Garden complete all as specified ad dirtected.
62M&L for Spraying nozzle 25mm for gardening complete all as specified and as directed
63M&L for Cleaning and removing of all silt, dirt, mud, stone, etc. from inside the borewell andFlushing out / desilting of the bore well by using compresser hydro pressure jet for six hourstill clear the silt in the casing pipe by achiving clear water, and washing with hydro pressure jet using foam/oils, disinfecting the bore using sodium hypochloride solution and washing out till water is obtained to the required turbidity (clean water) to the entire satisfacton of Engr-In-Charge complete all as directed,including Lowering and re-fixing of submersible pump set of capacity upto 15 HP at different places including pump set fitting commissioning and testing after replacement of defective parts with new one alongwith coloumn pipe 50/80 mm bore with cable by suitable arrangment of chain pully system and connection with startor electrically and connection with pipe line mechanically complete all as specified and ditected.
64Supply, fixing testing and commissioning ofsubmersible pumps 415 volts, three Phase system of size 5 HP( KS6B-0508) , LPM 120 to 170 LPM Head 90 to 130 Mtr capacity 50 Hz, 8 to 12 stage with delivery size upto 80mm suitabelfor 6 " to 8" bore complete all as specified and as directed.
65M&L fully Automatic Star Delta Motor starter 5 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, three -Phase) and Relay Range 11-18 complete all as specified and directed. Make : L&T/SKN/SIEMENS
66Schedule of credit amount of Rs. 0.00 to be deducted during AOC