| 1 | Networking - SupplyOFC cable 6core |
| 2 | Pigtail |
| 3 | Splice Box |
| 4 | 12 Port LIU Loaded |
| 5 | 24 Port LIU Loaded |
| 6 | SC-LC Patch cord |
| 7 | HDMI Cable 10Mtrs |
| 8 | Ladder Type Cable Tray Dimension:100(H)x300(W),Thickness: 2MM |
| 9 | Cat6 4 Pair UTP Cable. |
| 10 | Cat6 Information outlet |
| 11 | Face plate Singlex. |
| 12 | 3 x 3 Surface mount box. |
| 13 | Cat6 patch cord, 2 Mtr / 3 Mtr |
| 14 | Cat6 patch cord, 1 Mtr |
| 15 | Cat6 patch panel 24 port Loaded |
| 16 | PVC Cable Management System (Conforms to IEC 61084 / BS 476 and BS 4678): 100x50mm Cable management system with base and lid Make: Legrand/ MK - ISI Approved |
| 17 | PVC Cable Management System accessories |
| 18 | 20mm ISI PVC Conduit with all accessories- Ivory Make: Toms/Balco/Konceal/ Hycount - ISI Approved |
| 19 | 25mm ISI PVC Conduit with all accessories- Ivory Make: Toms/Balco/Konceal/ Hycount - ISI Approved |
| 20 | 25mm HDPE Pipe with all accessories Make: Toms/Balco/Konceal/ Hycount - ISI Approved |
| 21 | 9U Rack with Accessories |
| 22 | Networking-Installation charges Laying OFC cable |
| 23 | OFC Splicing charge |
| 24 | LIU Fixing |
| 25 | Laying of 4 Pair UTP Cable |
| 26 | Laying of PVC Conduit |
| 27 | Fixing and termination of Information outlet. |
| 28 | Fixing and port termination of patch panel |
| 29 | Fixing of Ladder Type Cable Tray 100MM |
| 30 | Fixing/Laying of PVC Cable Management Systems with accessories |
| 31 | Fixing & Dressing of wall mount Rack |
| 32 | Fixing of Access point |
| 33 | Digging, Laying of HDPE/ Water Pipe in Hard Soil / Tar-Road / Concrete Excavation/ Trenching, Baked-Brick- Layering, Refilling & Restoration/Resurfacing with Bitumen or Concrete , upto 600mm depth. |
| 34 | Charges for Approval of Electrical Inspectorate & KSEB |
| 35 | Configuration, Testing & Commissioning of Network |
| 36 | Active ComponentsCore Switch 24 Port Switch 10/100/1000Mbps with 24x10G Uplink Managed Switch |
| 37 | 24 Port 10/100/1000 Gigabit manageableSwitch 10G Uplink |
| 38 | SFP Module 10G |
| 39 | 32\"\" TV Monitor for NMS |
| 40 | Wireless access point |
| 41 | PoE Injector |
| 42 | Wireless router |
| 43 | Media convertor |
| 44 | Electrical Items-Supply3 Phase 4 Way Vertical DB Double Door with provision for fixing 4P MCCB up to 125A as incomerMake: ABB/Legrand/L&T/Siemens/Schneider- ISI Approved |
| 45 | 80A-100A Four pole MCCBMake: ABB/Legrand/L&T/Siemens/Schneider- ISI Approved |
| 46 | 50A-63A Four pole MCCB Make: ABB/Legrand/L&T/Siemens/Schneider- ISI Approved |
| 47 | 3 Phase 4 Way Vertical DB Double Door with provision for fixing 4P isolator as incomer Make: ABB/Legrand/L&T/Siemens/Schneider- ISI Approved |
| 48 | 12 way double door SPN DBMake: ABB/Legrand/L&T/Siemens/Schneider- ISI Approved |
| 49 | 8 way double door SPN DBMake: ABB/Legrand/L&T/Siemens/Schneider- ISI Approved |
| 50 | 63A four Pole ELCB with 100ma Leakage Make: ABB/Legrand/L&T/Siemens/Schneider- ISI Approved |
| 51 | 40A Two Pole ELCB with 100ma LeakageMake: ABB/Legrand/L&T/Siemens/Schneider- ISI Approved |
| 52 | 40 Amp two pole Isolator Make: ABB/Legrand/L&T/Siemens/Schneider- ISI Approved |
| 53 | 10A Single Pole MCBMake: ABB/Legrand/L&T/Siemens/Schneider- ISI Approved |
| 54 | 6A Single Pole MCB Make: ABB/Legrand/L&T/Siemens/Schneider- ISI Approved |
| 55 | 3 Nos of 6Amps Socket controlled by three Switches with PVC Box [Modular Type] Make: Legrand-Mylinc/L&T-ORIS/Crabtree-Wraparound/MK Wraparound/Schneider-Verona : ISI Approved |
| 56 | 1 nos of 16A socket controlled by 1 switch with surface mounted box - ModularMake: Legrand-Mylinc/L&T-ORIS/Crabtree-Wraparound/Wraparound/Schneider-Verona : ISI Approved |
| 57 | PVC / XLPE insulated armoured cables: 4 core X16 sq.mm aluminium conductorsMake: Finolex/Havells/V-Guard -ISI Approved |
| 58 | Brass Compression Cable Glands (28mm) for 4 x 16 sq.mm 1.1KV grade Cable Make: ISI Approved |
| 59 | PVC / XLPE insulated armoured cables: 4 core X25 sq.mm aluminium conductors Make: Finolex/Havells/V-Guard -ISI Approved |
| 60 | Brass Compression Cable Glands (28mm) for 4 x 25 sq.mm 1.1KV grade CableMake: ISI Approved |
| 61 | 3 nos of 10 sq. mm and 1 nos of 6 sq. mm PVC insulated Copper WireMake: Finolex/Havells/V-Guard -ISI Approved |
| 62 | 3 nos of 6 sq. mm and 1 nos of 4 sq. mm PVC insulated Copper Wire Make: Finolex/Havells/V-Guard -ISI Approved |
| 63 | 2 nos of 2.5 sq. mm and 1 nos of 1.5 sq. mm PVC insulated Copper WireMake: Finolex/Havells/V-Guard -ISI Approved |
| 64 | All materials for Plate(Galvanised Iron) Earthing as per IS-3043-1987 ISI Approved |
| 65 | 1 run 10SWG copper Make: ISI Approved |
| 66 | ELECTRICAL-LabourFixing of 3 Phase 4 Way Vertical DB Double Door with provision for fixing 4P MCCB up to 125A as incomer |
| 67 | Fixing of 80A-100A Four pole MCCB |
| 68 | Fixing of 50A-63A Four pole MCCB |
| 69 | Fixing of 3 Phase 4 Way Vertical DB Double Door with provision for fixing 4P isolator as incomer |
| 70 | Fixing of 12 way double door SPN DB |
| 71 | Fixing of 8 way double door SPN DB |
| 72 | Fixing of 63A four Pole ELCB with 100ma Leakage |
| 73 | Fixing of 40A Two Pole ELCB with 100ma Leakage |
| 74 | Fixing of 40 Amp two pole Isolator |
| 75 | Fixing of 10A Single Pole MCB |
| 76 | Fixing of 6A Single Pole MCB |
| 77 | Fixing of 3 Nos of 6Amps Socket controlled by three Switches with PVC Box [Modular Type] |
| 78 | Fixing of 1 nos of 16A socket controlled by 1 switch with surface mounted box - Modular |
| 79 | Laying of PVC / XLPE insulated armoured cables: 4 core X16 sq.mm aluminium conductors |
| 80 | Glands termination for 4 x 16 sq.mm 1.1KV grade Cable |
| 81 | Laying of PVC / XLPE insulated armoured cables: 4 core X25 sq.mm aluminium conductors |
| 82 | Glands termination for 4 x 25 sq.mm 1.1KV grade Cable |
| 83 | Laying of 3 nos of 10 sq. mm and 1 nos of 6 sq. mm PVC insulated Copper Wire |
| 84 | Laying of 3 nos of 6 sq. mm and 1 nos of 4 sq. mm PVC insulated Copper Wire |
| 85 | Laying of 2 nos of 2.5 sq. mm and 1 nos of 1.5 sq. mm PVC insulated Copper Wire |
| 86 | Labour Charges for all materials for Plate(Galvanised Iron) Earthing as per IS-3043-1987 ISI Approved |
| 87 | Laying of 1 run 10SWG copper |
| 88 | Additional Labour charge/ Skilled Worker\"s Charge for Completion of Work (Charge Include Demolishing, Reroute, Rework of Existing Network/ Electrical Wiring, Seating arrangement, Dismantling of Old Cables & Conduits etc.). |