Tender For Repair Of Ei And Fans In Mpl. School-Repair Of E.I & Fans In Municipal School East Old Seelampur And Kaushik Puri At Ward No. 214 (Azad Nagar) Under Shahdara (South) Zone., Delhi-Delhi

Municipal Corporation Of Delhi has published Tender For Repair Of Ei And Fans In Mpl. School-Repair Of E.I & Fans In Municipal School East Old Seelampur And Kaushik Puri At Ward No. 214 (Azad Nagar) Under Shahdara (South) Zone.. Submission Date for this Tender is 18-01-2024. Electrical Maintenance Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

41589837
Tender For Repair Of Ei And Fans In Mpl. School-Repair Of E.I & Fans In Municipal School East Old Seelampur And Kaushik Puri At Ward No. 214 (Azad Nagar) Under Shahdara (South) Zone.
Open Tender
Indian
Delhi
Delhi
18-01-2024

Tender Details

Tender For Repair Of Ei And Fans In Mpl. School-Repair Of E.I & Fans In Municipal School East Old Seelampur And Kaushik Puri At Ward No. 214 ( Azad Nagar ) Under Shahdara ( South ) Zone. ; 1 Approved Rates 2 Od22195 / 2023-2024:Dsr22 7.7.1 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required.Upto 35 Sq. Mm ( Clamped With 1Mm Thick Saddle ) 3 Od22196 / 2023-2024:Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 4 Od22198 / 2023-2024:Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cmm / W ) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm ( Tolerance As Per Is : 374- 2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 5 Od22199 / 2023-2024:Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required. Upto 450 Mm Sweep 6 Od22200 / 2023-2024:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator 8 Way, Double Door 7 Od22201 / 2023-2024:Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C 8 Od22202 / 2023-2024:Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. 100 Amp, 16 Ka, Tpmccb 9 Od22204 / 2023-2024:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 4 Sq. Mm 10 Od22205 / 2023-2024:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 2.5 Sq. Mm 11 Od22207 / 2023-2024:Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required. Group C 12 Od22211 / 2023-2024:Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm 13 Od22212 / 2023-2024:Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps 14 Od22213 / 2023-2024:Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps 15 Od22557 / 2023-2024:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 1.5 Sq. Mm 16 Od22558 / 2023-2024:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 6 Sq. Mm 17 Od22560 / 2023-2024:Dsr 22 .1.23.1 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required.5 / 6 Amps Switch 18 Od22561 / 2023-2024:Dsr 22.1.23.4 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required. 3 Pin 5 / 6 Amp Socket Outlet 19 Od22562 / 2023-2024:Dsr22 1.23.5: Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet 20 Od22563 / 2023-2024:Dsr22 1.23.3: Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required.15 / 16 Amp Switch 21 Od22564 / 2023-2024:Dsr 22 1.21.2: Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm 22 Od22586 / 2023-2024:Supply And Fixing Of 3 Mm Thick Phenolic Laminated Sheet 23 Od22616 / 2023-2024:1.17.11 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 2 X 2.5 Sq. Mm 24 122.1.47:Supply Of 250 Mm ( 10 Inch ) Sweep 1250 Rpm Exhaust Fan Fresh Air Type Complete With Shutter Blades Etc. As Required. 25 122.2.2: P / Fhot Press Sheet Mouldedcompound ( Smc ) Fire Retardant ( Temp. Resistance Up To 200 C ) , Ip 55 Weather Proof Polebox Of Innerdimension 200X160x98mm ( Ns ) Complete With Suitable Arrangement For Fixing Of 2 Nosof 6 To 32 Amp Single Pole Mcb & 63 Amp. Doublepole Isolator ( Mcb / Isolator Excluded ) Withneutral Link Duly Shorting On Din Channel With2 Nos Of Ms Clamps With Ss Back Plateofsuitable Size With Danger Monogram Property Printed On The Coveretc Asreqd. Asreqd. 26 122.2.30.A:Sitc Of 150W Led Flood Light Luminaire Fitted With Lens, Made Of Pressure Die Cast Aluminium Housing & Toughened Glass Cover Complete With The Following Specification As Reqd With Ip 66 Protection ( A ) Total System Wattage =150 Watt + / - 5% ( B ) Luminaire Efficacy>=100 Lm / W ( C ) Power Factor>=0.95 ( D ) Protection Class- Ip-66 27 122.2.39:S / I / T / C Of Led Tube Type Luminaire 20 Watt Rating Complete With Polycarbonate Housing Batten Integrated Electronic Driver Prewired With High Efficient Leds With The Following: ( A ) Total System Wattage 20 Watt + / - 5% ( B ) Luminous Efficacy Lumens / Watt >=95 ( C ) Power Factor >=0.95 28 122.2.41:S / I / T / C Of Led Tubelight Lamp T-5 / T-8 20 Watt Rating Made Up Ofhigh Efficient Ledswith The Following Specifications: ( A ) Total System Wattage 20 Watt + / - 5% ( B ) Luminous Efficacy Lumens / Watt >=95 ( C ) Power Factor >=0.95 29 122.2.42:Repair / Rewinding Of Existing 1Hp Mono Block Pump Set Including Replacement Of Parts Like Gun Metal Bush / Bearing Condenser, Impeller Etc To Make The Pump Functional As Required. 30 122.2.188:S / I / T / C Of Led Tube Type Luminaire 2X20 Watt Rating Box Type Complete With Extruded Al. Batten Prewired With High Efficient Leds With The Following: ( A ) Total System Wattage 40 Watt+ / - 5% ( B ) Luminous Efficacy Lumens / Watt >=95 ( C ) Power Factor >=0.95. 31 122.2.236:Rewinding Of Ac Ceiling Fan Of All Sizes Andmake Including Oiling, Greasing As Required New Model ( Light Weight ) 32 122.2.238:Replacement Of Ball Bearing Of Size 117 / 120 Nbc Equivalent Skf Make As Required. 33 122.2.239:Replacement Of Fan Condenser 2.5 Mf As Required. 34 122.1.2:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-2C*6 Sqmm 35 122.1.30:Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-4C*25 Sqmm

Key Value

Document Fees
INR 590 /-
EMD
INR 10848.0 /-
Tender Value
INR 5.42 Lakhs /-

BOQ Items

Work Name:Repair of EI and Fans in Mpl. School-Repair of E.I & Fans in Municipal School East Old Seelampur and Kaushik Puri at Ward No. 214 (Azad Nagar) under Shahdara (South) Zone.
Sl. No. Item Description
1APPROVED RATES
2OD22195/2023-2024:DSR22 7.7.1 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
3OD22196/2023-2024:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
4OD22198/2023-2024:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
5OD22199/2023-2024:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required. Upto 450 mm sweep
6OD22200/2023-2024:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 8 way, Double door
7OD22201/2023-2024:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
8OD22202/2023-2024:Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 Amp, 16 KA, TPMCCB
9OD22204/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm
10OD22205/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
11OD22207/2023-2024:Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C
12OD22211/2023-2024:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
13OD22212/2023-2024:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
14OD22213/2023-2024:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
15OD22557/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
16OD22558/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 6 sq. mm
17OD22560/2023-2024:DSR 22 .1.23.1 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
18OD22561/2023-2024:DSR 22.1.23.4 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 amp socket outlet
19OD22562/2023-2024:DSR22 1.23.5: Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet
20OD22563/2023-2024:DSR22 1.23.3: Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch
21OD22564/2023-2024:DSR 22 1.21.2: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
22OD22586/2023-2024:Supply and fixing of 3 mm thick phenolic laminated sheet
23OD22616/2023-2024:1.17.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 2.5 sq. mm
24122.1.47:Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.
25122.2.2: P/FHot press sheet mouldedcompound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof polebox of innerdimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nosof 6 to 32 amp single pole MCB & 63 Amp. Doublepole isolator (MCB/Isolator excluded) withneutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plateofsuitable size with danger monogram property printed on the coveretc asreqd. asreqd.
26122.2.30.a:SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
27122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
28122.2.41:S/I/T/C of LED Tubelight lamp T-5/T-8 20 Watt rating made up ofhigh efficient LEDswith the following specifications:(a) Total system wattage 20 watt +/- 5% (b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
29122.2.42:Repair/Rewinding of existing 1HP mono block pump set including replacement of parts like gun metal bush/ bearing condenser, impeller etc to make the pump functional as required.
30122.2.188:S/I/T/C of LED Tube type luminaire 2X20 watt rating box type complete with extruded Al. batten prewired with high efficient LEDs with the following: (A) Total system wattage 40 watt+/- 5% (B) Luminous efficacy lumens/ watt >=95(C) Power Factor >=0.95.
31122.2.236:Rewinding of AC ceiling fan of all sizes andmake including oiling, greasing as required New Model (Light Weight)
32122.2.238:Replacement of ball bearing of size 117/120 NBC equivalent SKF make as required.
33122.2.239:Replacement of fan condenser 2.5 mF as required.
34122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
35122.1.30:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*25 sqmm