Public Administrative Department Local Bodies Closing in 0 days TDR #41576048

Tender For Repair And Maintenance Of Community Hall, (Near Sitala Mandir And Kali Mandir) At Ward No.07 At Sitanagar.

Issued by Local Bodies · diglipur, Andaman And Nicobar Islands
Tender Value
21.02 Lakhs
Estimated cost
Bid Submission
23 Jan 2024
0 days left
EMD
42048
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
diglipur → Andaman And Nicobar Islands
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair And Maintenance Of Community Hall, ( Near Sitala Mandir And Kali Mandir ) At Ward No.07 At Sitanagar.

BOQ

Name of Work:Repair and Maintenance of Community Hall, (Near Sitala Mandir and Kali Mandir) at ward No.07 at Sitanagar.
Sl. No. Item Description
1Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
2Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
3Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
4Asbestossheet
5Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
6Of area 3 sq. metres and below
7Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20mmnominalsize derivedfromnatural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling&dressing & finishing the top smooth.
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
91:3:6 (1 Cement : 3 coarse sand(zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources).
10Centering and shuttering including strutting, propping etc. and removal of form for :
11Foundations, footings, bases of columns, etc. for mass concrete
12Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
13Kiln seasoned and chemically treated hollock wood.
14Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, (weight not less than 10kg per sqm)including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.
15Kiln seasoned and chemically treated hollock wood
1635 mm thick
17Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
18Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
19300x16 mm
20Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
21150x10 mm
22100x10 mm
23Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
24125 mm
25100 mm
26Applying priming coat :
27With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
28Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
29Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
30Ridges plain (500 - 600mm)
31Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :
32Two or more coats on new work
33Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
34Two or more coats on new work
35Finishing walls with textured exterior paint of required shade :
36Old work (One or more coats) applied @ 1.82 ltr/10 sqm.
37Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade :
38Old work (one or more coats)
39Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
40Size of Tile 600x600 mm
41Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer-in-charge
42Extruded section profile size 48x40 mm
43Providing and fixing to existing door frames.
4424 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
45Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In- Charge.
4612 mm cement plaster finished with a floating coat of neat cement of mix :
471:4 (1 cement: 4 fine sand)
48Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
4910 litre capacity - White
50Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931:
5115 mm nominal bore.
52Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
53Using M.S. angels 40x40x6 mm for diagonal braces
54Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work
5515 mm dia. nominal bore
56Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
57Semi rigid pipe
5832 mm dia
59Providing and Fixing Eaves or facia boards with precoated profile sheet30 cm wide i/c fixing wherever necessary all complete as directed by Engineer incharge (factory made)
60Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.
61Selected Planks of hard wood cat -II A
62Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured).panelling forpanelled or panelled and glazed shutters 25 mm to 40 mm thick:
63Selected Planks of hard wood cat -II A
64Providing Cement Concrete surface drain including earth excavation, 10 cm thick base concrete & 23 cm thick side walling with 1:3:6 (1 cement : 3 Pulverized sand :40mm 4Sand) i/c 6stone aggregate floating coat of neat nominalsize) finishing with 1:4 ( 1Cement including down and its top exposed surface drain).
6523*23 cm surface drain
66Electrical Works
67Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steelconduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required
68Group-C
69Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVCConduit as required. (Havells/standarad/Anchor/Polycab) or Equivalent to ISI Standarad.
702 X 4 sq. mm + 1 X 4 sq. mm earth wire
712 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
722 X 6 sq. mm + 1 X 6 sq. mm earth wire
73Supplying and fixingSuitable sizePVC box with modular plate and cover in front of on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection,etc. as required.
74Supplying and fixingSuitable sizePVC box with modular plate and cover in front of on surface or in recess, including providing and fixing 6 pin 5/6 amps modular socket outlet and 15/16 amps modular switch, connection,etc. as required.
75Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ PVC block including connection etc as required.
76Installation, testing and commissioning of pre-wired, LED FITINGof all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
77Installation, testing and commissioning of ceiling fan, including down road and wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
78Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB /Isolator)
7912 way, Double door
80Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
81Single Pole
82Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
8363 Amps, 2 Pole Isolator
84Earthing with G.I.earth pipe 4.5 mtr long,40mm dia i/c accessories,and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal and salt as required.
85Providing and laying earth connection from earth electrode with 4.00 sq.mm dia copper wire in 15mm diaG.I. pipe from earth electrodeas required.
86Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
87Supplying of A.C. Ceiling fan(1200mm sweep ) suitable for operation on 230 Volts, single Phase, 50Hz, A.C Supply including 300mm long rod and without regulator as required.(Make: Bajaj/ Usha/ Orient/Crompton or equivalent to ISI standard).
88supplying and fixing two module stepped type electronic fan regulater on the existing modular plate switch box i/c connections but excluding modular plate etc(Make: anchor/polycab/havells etc. or or equivalent to ISI standarad.
89Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
90Supplying and fixing of syntex meter box for fixing of energy meter (\"PRODUCT CODE GS-JB2520). MAKE: sintex/hanger or equivalent to ISI standarad.
91Supplying and prewire of LED tube light 36W (MAKE: INTENSO LED BATTEN AL4 FEET 36W) or equivalent to ISI standarad.
92Supplying and fixing of julbiee clamp 4 inch dia and thickness of 0.6mm.
93Supplying and fixing rewirable porceline with fuse unit of 32 to 40 amps on energy meter board.

AI Tender Summary

OUR REF NO 41576048
AUTHORITY Local Bodies
TENDER VALUE 21.02 Lakhs
LAST DATE 23-01-2024
Authority
Authority Name Zilla Parishad
Work Description Repair And Maintenance Of Community Hall, ( Near Sitala Mandir And Kali Mandir ) At Ward No.07 At Sitanagar.
Basic Detail
Tender No EE/N and MA/ZP/MB/2023-24/15
Bidding Type Tender
Location
City diglipur
State Andaman And Nicobar Islands
Key Dates
Publish Date 11 Jan 2024
Submission Date 23 Jan 2024
Open Date 23 Jan 2024
Finance
Tender Value 21.02 Lakhs
Tender Fee 500
EMD 42048
Exemption Not Available
Document List
65b55267-701a-40cd-a0b7-991dac05101c.html
BOQ_13788.xls
Notice.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 11, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 23, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 23, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

65b55267-701a-40cd-a0b7-991dac05101c.html

xls

BOQ_13788.xls

pdf

Notice.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders