Tender For Repair And Maintenance Of Community Hall, (Near Sitala Mandir And Kali Mandir) At Ward No.07 At Sitanagar.
Tender Value
21.02 Lakhs
Estimated cost
Bid Submission
23 Jan 2024
0 days left
EMD
42048
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
diglipur → Andaman And Nicobar Islands
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair And Maintenance Of Community Hall, ( Near Sitala Mandir And Kali Mandir ) At Ward No.07 At Sitanagar.
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 2 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 4 | Asbestossheet |
| 5 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 6 | Of area 3 sq. metres and below |
| 7 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20mmnominalsize derivedfromnatural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling&dressing & finishing the top smooth. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 9 | 1:3:6 (1 Cement : 3 coarse sand(zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 11 | Foundations, footings, bases of columns, etc. for mass concrete |
| 12 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
| 13 | Kiln seasoned and chemically treated hollock wood. |
| 14 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, (weight not less than 10kg per sqm)including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. |
| 15 | Kiln seasoned and chemically treated hollock wood |
| 16 | 35 mm thick |
| 17 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 18 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 19 | 300x16 mm |
| 20 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 21 | 150x10 mm |
| 22 | 100x10 mm |
| 23 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 24 | 125 mm |
| 25 | 100 mm |
| 26 | Applying priming coat : |
| 27 | With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 28 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 29 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 30 | Ridges plain (500 - 600mm) |
| 31 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : |
| 32 | Two or more coats on new work |
| 33 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 34 | Two or more coats on new work |
| 35 | Finishing walls with textured exterior paint of required shade : |
| 36 | Old work (One or more coats) applied @ 1.82 ltr/10 sqm. |
| 37 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : |
| 38 | Old work (one or more coats) |
| 39 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 40 | Size of Tile 600x600 mm |
| 41 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer-in-charge |
| 42 | Extruded section profile size 48x40 mm |
| 43 | Providing and fixing to existing door frames. |
| 44 | 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). |
| 45 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In- Charge. |
| 46 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
| 47 | 1:4 (1 cement: 4 fine sand) |
| 48 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 49 | 10 litre capacity - White |
| 50 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: |
| 51 | 15 mm nominal bore. |
| 52 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 53 | Using M.S. angels 40x40x6 mm for diagonal braces |
| 54 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work |
| 55 | 15 mm dia. nominal bore |
| 56 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 57 | Semi rigid pipe |
| 58 | 32 mm dia |
| 59 | Providing and Fixing Eaves or facia boards with precoated profile sheet30 cm wide i/c fixing wherever necessary all complete as directed by Engineer incharge (factory made) |
| 60 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. |
| 61 | Selected Planks of hard wood cat -II A |
| 62 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured).panelling forpanelled or panelled and glazed shutters 25 mm to 40 mm thick: |
| 63 | Selected Planks of hard wood cat -II A |
| 64 | Providing Cement Concrete surface drain including earth excavation, 10 cm thick base concrete & 23 cm thick side walling with 1:3:6 (1 cement : 3 Pulverized sand :40mm 4Sand) i/c 6stone aggregate floating coat of neat nominalsize) finishing with 1:4 ( 1Cement including down and its top exposed surface drain). |
| 65 | 23*23 cm surface drain |
| 66 | Electrical Works |
| 67 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steelconduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required |
| 68 | Group-C |
| 69 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVCConduit as required. (Havells/standarad/Anchor/Polycab) or Equivalent to ISI Standarad. |
| 70 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 71 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 72 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 73 | Supplying and fixingSuitable sizePVC box with modular plate and cover in front of on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection,etc. as required. |
| 74 | Supplying and fixingSuitable sizePVC box with modular plate and cover in front of on surface or in recess, including providing and fixing 6 pin 5/6 amps modular socket outlet and 15/16 amps modular switch, connection,etc. as required. |
| 75 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ PVC block including connection etc as required. |
| 76 | Installation, testing and commissioning of pre-wired, LED FITINGof all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 77 | Installation, testing and commissioning of ceiling fan, including down road and wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 78 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB /Isolator) |
| 79 | 12 way, Double door |
| 80 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 81 | Single Pole |
| 82 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 83 | 63 Amps, 2 Pole Isolator |
| 84 | Earthing with G.I.earth pipe 4.5 mtr long,40mm dia i/c accessories,and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal and salt as required. |
| 85 | Providing and laying earth connection from earth electrode with 4.00 sq.mm dia copper wire in 15mm diaG.I. pipe from earth electrodeas required. |
| 86 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 87 | Supplying of A.C. Ceiling fan(1200mm sweep ) suitable for operation on 230 Volts, single Phase, 50Hz, A.C Supply including 300mm long rod and without regulator as required.(Make: Bajaj/ Usha/ Orient/Crompton or equivalent to ISI standard). |
| 88 | supplying and fixing two module stepped type electronic fan regulater on the existing modular plate switch box i/c connections but excluding modular plate etc(Make: anchor/polycab/havells etc. or or equivalent to ISI standarad. |
| 89 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 90 | Supplying and fixing of syntex meter box for fixing of energy meter (\"PRODUCT CODE GS-JB2520). MAKE: sintex/hanger or equivalent to ISI standarad. |
| 91 | Supplying and prewire of LED tube light 36W (MAKE: INTENSO LED BATTEN AL4 FEET 36W) or equivalent to ISI standarad. |
| 92 | Supplying and fixing of julbiee clamp 4 inch dia and thickness of 0.6mm. |
| 93 | Supplying and fixing rewirable porceline with fuse unit of 32 to 40 amps on energy meter board. |
AI Tender Summary
Tender Timeline
Jan 11, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedJan 23, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 23, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender