Tender For Supply, Installation, Testing And Commissioning Of Hvac (Retrofitted By Vrf Air Conditioning Works) For Spd Ground And First Floor Cel Campus, Sahibabad., sahibabad-Uttar Pradesh

Central Electronics Limited-CEL has published Tender For Supply, Installation, Testing And Commissioning Of Hvac (Retrofitted By Vrf Air Conditioning Works) For Spd Ground And First Floor Cel Campus, Sahibabad.. Submission Date for this Tender is 22-01-2024. Air Conditioner Tenders in sahibabad Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41564527
Corrigendum : Tender For Supply, Installation, Testing And Commissioning Of Hvac (Retrofitted By Vrf Air Conditioning Works) For Spd Ground And First Floor Cel Campus, Sahibabad.
Open Tender
Indian
Uttar Pradesh
sahibabad
22-01-2024

Tender Details

Tender For Supply, Installation, Testing And Commissioning Of Hvac ( Retrofitted By Vrf Air Conditioning Works ) For Spd Ground And First Floor Cel Campus, Sahibabad.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Jan-2024 Corrigendum-I Technical Bid 22-01-2024

Key Value

Document Fees
Refer document
EMD
INR 186800.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: SITC of HVAC (Retrofitted by VRF air Conditioning Works) for SPD Ground & First floor CEL Campus, Sahibabad
Sl. No. Item Description
1Supplying, Installation, Testing and commissioning ofVariable refrigerant volume/ Variable refrigerant flow modular type BMS compatible air conditioning system as per details given in Annexure-B.
2Outdoor Unit 46HP
3Outdoor Unit 44HP
4Outdoor Unit 20 HP
5Outdoor Unit 14 HP
6Supplying, installation, testing & commissioning of different types Indoor units as per details given in Annexure-B.
74.0 TR, 4 way flow as per details given in Annexure-B.
83.0 TR, 4 way flow as per details given in Annexure-B.
9Supplying, installation, testing & Commissioning of Refrigerant "Y" Joint with insulation required for distribution of refrigerant in copper piping etc. complete as reqd
10Providing& fixing Cordedremote for AHU"s
11Providing& fixing Cordless remote for above capacities of cassette units
12Supply, Installation, Testing and Commissioning offactory built Floor mounting skin type air handlingunits with 25 mm thick panels as per details given in Annexure-B.
13HorizontalAHU--36 TR, 14500 CFM, 60 mm static
14HorizontalAHU--33 TR, 13000 CFM, 60 mm static
15Ceiling suspended 16 TR AHU-6400 CFM, 60 mm static
16Supply & fixing of air handling unit control box in the existing VRF system for control the function of air handling units complete i/c testing & commissioning etc complete as required.
17Supply & fixing of air handling unit Expansion valve kit in the existing VRF system for control the function of air handling units complete i/c testing & commissioning etc complete as required.
18Supplying & Installation and interconnecting of following size of refrigerant copper pipe work with fitting duly insulated as per details given in Annexure-B.
196.40 mm (0.250 inches) dia (20 SWG thick) with 13mm thick nitrile rubber insulation
209.53 mm (0.375 inches) dia (20 SWG thick) with 13mm thick nitrile rubber insulation
2112.7 mm (0.50 inches) dia (20 SWG thick) with 13mm thick nitrile rubber insulation.
2215.86 mm (0.625 inches) dia (20 SWG thick)with 13mm thick nitrile rubber insulation
2319.1 mm (0.750 inches) dia (18 SWG thick) with 13mm thick nitrile rubber insulation
2422.2mm (0.875 inches) dia (18 SWG thick) with 19mm thick nitrile rubber insulation
2528.6 mm (1 1/8 inches) dia (18 SWG thick) with 19mm thick nitrile rubber insulation
2634.1 mm (1 1/8 inches) dia (18 SWG thick) with 19mm thick nitrile rubber insulation
2741.3 mm (1 1/8 inches) dia (18 SWG thick) with 19mm thick nitrile rubber insulation
28Providing & fixing of Rigid UPVC pipe complete with fittings as per details given in Annexure-B.
2940 MM
3032 MM
31Supplying and installing following size of perforated painted M.S. cable trays
32200 mm width X 75 mm depth X 1.6 mm thickness
33Cover for above cable tray
34Providing and fixing of 2 core 1.5 sqmm PVC insulated and PVC sheathed bright annealed copper conductor cable as per details given in Annexure-B.
35Power and Control Cabling: Power cabling of VRF Out door Unit including supply of cables etc as per details given in Annexure-B.
363.5C x 35 Sqmm Aluminium
374C x 16 Sqmm Aluminium
38Supplying and making indoor end termination with brass compression gland and aluminium lugs as per details given in Annexure-B.
393.5C X 35 SQMM
404C X 16 SQMM
41Wiring for circuit/ submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor etc as per details given in Annexure-B.
422x2.5 sqmm+1x2.5 sqmm earth wire
432x4 sqmm+1x4 sqmm earth wire
44Supplying and fixing suitable size GI box with modular plate and cover etc as per details given in Annexure-B.
45Supply of following cables for input power to LT panel
463.5 Cx 400 sqmm Al.Ar XLPE LT cable of 1.1 KV grade
473.5 Cx 300 sqmm Al.Ar XLPE LT cable of 1.1 KV grade
48Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade as per details given in Annexure-B.
49Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kv grade as required
503.5x 400 sqmm
513.5x 300 sqmm
52Providing and fixing 8 SWG dia G.I. wire on surface or in recessfor loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required
53Providing,fixing,testing and commissioningHVACElectrical ControlPanels Installation & Degree of Protection: Outdoor (IP-55) as per details given in Annexure-B.
54Supplying and Installation of starter panel for AHU motor having VFD, its bypass arrangement etc as per AHU motor capacity requirement.
55Breaking, cutting and providing/fixing new false ceiling for adjustment/cutting of air ducts, installation of new cassette AC"s etc as per site requirement.
56Site fabricated GSS Ducting: SITCofGSSRectangularDucting(siteFabricated)complete withfittings, flanges etc. as per details given in Annexure-B.
5724 G (0.63 mm)
5822 G (0.80 mm)
59Supply, installation & testing of acoustic lining within supply and returnairductsasper specifications as per details given in Annexure-B.
60Flexible connection: SITCofFlexibleConnectionbetweenIDUandductcomplete withfittings,flanges, supports,allaccessoriesasper specifications.
61Manual Volume Control Duct Dampers: SITC of 16 G GI Flanged Frame / 24 G GI aerofoil blades type VolumeControlDuctDampersasper specifications as per details given in Annexure-B.
62ITEMS CONSIDERED UNDER BUY BACK Following prices can only be filled in by prefixing MINUS (-) e.g. -100, -200 etc.
63Compressor scroll(Hermetic)- Denfoss commercial compressor( 14 TR), Make- Voltas
64Reciprocation compressor( 30 TR), Make- Voltas
65AHU unit( 8500 CFM approx)
66AHU unit( 15000 CFM approx)
67Chiller pump( 5 HP)
68Condenser Pump( 5 HP)
69Condenser Pump ( 7.5 HP)
70Cooling tower( 50 TR, 1.5 HP- CT fan)
71Cooling Tower ( 100 TR, 5 HP- CT fan)
72Compressor control panel- Electronics