| 1 | EARTHWORK |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding1.5 m in width or 10 sqm on plan) including dressing of sides andramming of bottoms, lift upto 1.5 m, including getting out theexcavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 50 meters lift upto 1.5 metre. |
| 4 | Supply and filling in plinth with sandy soil under floor including watering, ramming,consolidation and dressing complete. |
| 5 | CEMENT CONCRETE WORKS |
| 6 | Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering. a).1:4:8(1cement:2coarse/sand:4 graded stone aggt. 20 mm size) |
| 7 | Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 8 | RCC WORK |
| 9 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All works up to plinth level: 1:1.5:3(1 cement :1.5 coarse sand:3 graded stone aggregate 20mm nominal size) |
| 10 | Reinforced cement concrete work in wall (any thickness) including attached pilasters, buttress plinth and string course fillets, column, pillars, piers, abutments, post and sntrut etc, up to floor five level excluding cost of centering, shuttering, finishing and reinforcement:1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 ( 1cement :1.5 coarse/sand :3 graded stone aggregate 20 mm nominal size) |
| 12 | STEEL REINFORCEMENT |
| 13 | Reinforcement for R.C.C work I/c straightening,cutting,bending, placing in position and binding all complete upto to plinth & aboveplinthlevel.(Thermo-Mechanically Treated bars ) |
| 14 | FORM WORK |
| 15 | Centering and shutterig including struting ,propping etc.and removal of form for |
| 16 | Foundation,footings,bases of columns etc.and mass concrete |
| 17 | Columns, Pillars, Piers, Abutments, Posts and struts. |
| 18 | Lintels beams, plith beams, girders, bressumers and cantilevers. |
| 19 | Suspended floors,roofs,landing, balconies and access plaform |
| 20 | Stairs(excluding landings) except spiral-staircases |
| 21 | BRICK WORKS |
| 22 | Brick work with 1st class common burnt clay F.P.S. (non modular) brick in foundation and plinth in :Cement mortar 1:4 (1 cement :4 coarse sand ) |
| 23 | Half brick masonary 1st class common burnt clay F.P.S. (non modular) brick in susperstructure above plinth level upto floor V levelin cement mortar 1:4 (1 cement: 4 coarse sand) |
| 24 | WOOD WORKS |
| 25 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wronght framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately: (a) Local best qualityUningthou |
| 26 | Providing and fixing panelled or panelled and plazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, ecluding panelling which will be paid for separately, all complete as per direction of Engineer -in chargge . Local best quality Teak wood 35 mm thick shutters |
| 27 | Providing and fixing bright finished brass 100 mm mortise latch with one dead boltand a pair of lever handles with necessary screws complate (best make of approved quality) |
| 28 | Providing and fixingbright finished brass door latch with necessary screws etc. Complete . 300 x16 x5 mm |
| 29 | Providing and fixing bright finished brass Tower bolts (barrel type) with screws etc. complete. |
| 30 | 250 x 10 mm |
| 31 | 100 x 10 mm |
| 32 | Providing and fixing bright finished brass handles with necessary screws etc. complete. |
| 33 | 125 mm |
| 34 | 75 mm |
| 35 | Providing and fixing bright finished brass casement window fastener with necessary screws etc. complete. |
| 36 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 37 | STEEL WORKS |
| 38 | Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 39 | FLOORING |
| 40 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. 600x600mm |
| 41 | Providing and Laying vitrified floor tiles in different sizea (thickness to be specified by the manufacturer)with waterabsorption\"s less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades,in skirting,riser of stepsover 12mm thick bed of cement mortar 1:3 (1cement:3 coarse sand)including grouting the joints with white cement and matching pigment etc.,complete. Size of Tile 600 x 600 mm |
| 42 | Marble stone flooring with18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : Raj Nagar plain. |
| 43 | Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. Marble tiles (polished) Raj Nagar. |
| 44 | Extra for prefinished nosing to treads of steps of marble stone. |
| 45 | ROOFING AND CEILING: |
| 46 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, |
| 47 | shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to |
| 48 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I, |
| 49 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with Precoated galvanised iron profile sheets0.50 mm thick |
| 50 | Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Ridges plain (500 - 600mm).Precoated galvanised iron profile sheets0.50 mm thick |
| 51 | Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Gutter (600 mm over all girth). Precoated galvanised iron profile sheets0.50 mm thick |
| 52 | Steel work in built up tubular trusses includidng cutting, hoising, fixing in position and applying a coat ofapproved steel primer red oxide zinc chrome primer (conforming to IS :2079 ) welded and bolted inclusing special shape washer etc. complete. Electrical resistance welded tube (Conforming to IS:1611-1979). |
| 53 | FINISHING: |
| 54 | 12mm cement plaster 1:4 (1 cement: 4 coarse sand). |
| 55 | 15 mm cement plaster on rough side of single or half brick wall of mix : : 1:4 (1 cement: 4c sand) |
| 56 | 15 mm cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. |
| 57 | 6mmcement plasterof mix : 1:3 ( 1 cement : 3 f/s ) |
| 58 | Distermpering (two or more coats) with oil bound washable distemper of approved quality on new work i/c priming coat to give an even shade. |
| 59 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 60 | Applying one coat of water thiinable cement primer of approved brand and manufacture on wall surface :Water thibbable cement primer. |
| 61 | Applying priming coats with ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 62 | Applying priming coats with With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:- |
| 63 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 64 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 65 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 66 | Providing and fixing 20mm plank as eave board with. Uningthou Wood |
| 67 | SH: Land Development |
| 68 | Banking excavated earth in layers not exceeding 20 cm. in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal, and guide banks etc.,lead upto 50 m and lifts upto 1.5 m |
| 69 | All kind of soil |
| 70 | SH: Water Supply and Sanitary Installation (WSSI) |
| 71 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 72 | External work- 50 mm nominal outer dia Pipes |
| 73 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 74 | Internal work- 32mm nominal outer dia Pipes |
| 75 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 76 | GF |
| 77 | FF |
| 78 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
| 79 | GF |
| 80 | FF |
| 81 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- |
| 82 | (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass |
| 83 | GF |
| 84 | FF |
| 85 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 86 | GF |
| 87 | FF |
| 88 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe32 mm dia |
| 89 | GF |
| 90 | FF |
| 91 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 92 | GF |
| 93 | FF |
| 94 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. Pan |
| 95 | GF |
| 96 | FF |
| 97 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 98 | GF |
| 99 | FF |
| 100 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia |
| 101 | GF |
| 102 | FF |
| 103 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 104 | GF |
| 105 | FF |
| 106 | Providing and fixing toilet paper holder: C.P. brass |
| 107 | GF |
| 108 | FF |
| 109 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. |
| 110 | GF |
| 111 | FF |
| 112 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 113 | GF |
| 114 | FF |
| 115 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm |
| 116 | GF |
| 117 | FF |
| 118 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia |
| 119 | GF |
| 120 | FF |
| 121 | Providing and fixing UPVC soil, waste, rain water and vent pipes includingall requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge. a).110mm dia |
| 122 | b).75mm dia |
| 123 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cuttingand making good the walls etc.Internal work - Exposed on wall |
| 124 | Internal work - Exposed on wall |
| 125 | 25 mm diameters |
| 126 | 32 mm diameter |
| 127 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cuttingand making good the walls etc.external work - Exposed on wall |
| 128 | 15 mm |
| 129 | 20 mm |
| 130 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc.complete : 50 to 80 mm nominal bore |
| 131 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore |
| 132 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. : 15 mm Nominal bore |
| 133 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 134 | 15 mm nominal bore |
| 135 | 25 mm nominal bore. |
| 136 | Providing and fixing Water Storage Tanks with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level. a).2000 litres net capacity storage tanks |
| 137 | Supply and fixingself priming single phase (TEXMO or similar brand ) of 1HP water pump of approved quality |
| 138 | WATER RESERVOIR |
| 139 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) All kinds of soil. |
| 140 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.. |
| 141 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - a) 1:4:8 (1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 142 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 143 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 144 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 145 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 146 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 147 | Suspended floors, roofs, landings, balconies and access platform. |
| 148 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 149 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo-Mechanically Treated bars |
| 150 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : a) Cement mortar 1 : 3 (1 cement : 3 coarse sand) |
| 151 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster |
| 152 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.a),40mm thick with 20mm nominal size stone aggregate. |
| 153 | SEPTIK TANK |
| 154 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 155 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 156 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering --All work upto plinth level:a).1:4:8 (1 cement : 4 coarse sand :8 graded stone aggregate 40 mm nominal size) |
| 157 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering --All work upto plinth level: 1:1.5:3 (1 cement:1.5 coarse sand:3 graded stone aggregate 20mm nominal size). |
| 158 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : (a).1:1.5:3 (1 Cement : 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size).Uptofloor five level |
| 159 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level .a) Thermo-Mechanically Treated bars. |
| 160 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 161 | (a).Foundation, footing, bases of columns etc. and mass concrete. |
| 162 | b).Suspended floors, roofs, landings, balconies and access platform. |
| 163 | c).Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 164 | Providing and fixing C.I. Cover frame (for manhole and chambers).a).600 mm x 450 mm (heavy duty) |
| 165 | SH: External, Internal Electrification Installation & Fire Fighting |
| 166 | Wiring for light pt./power plug with 2x4mm2 FRLS PVC insulation copper conductor single core cable in surface/recessed medium class steel conduict along with 1 no. 4mm2 PVC insulated copper conductor single core cable for loop earthing etc as reqd |
| 167 | Wiring for circuit/ sub main wiring along withearth wire (the following sizes) of FRLS PVC insulation in surface/ recess mediul class steel conduit etc as reqd. |
| 168 | 1. 2x1.5 mm2+1x1.5mm2 earth wire |
| 169 | 2.2x2.5mm2+1x2.5mm2 earth wire |
| 170 | 3.2x4mm2+1x4mm2 earth wire |
| 171 | S/F bulk head fitting suitable for 100 W lamp complete with all acccessories i/c connection as reqd. |
| 172 | S/F brass battern/angle holder i/c connection. |
| 173 | Supply of 48\" sweep (1200mm) AC ceiling fan (Make Bajaj/Usha or Crompton). |
| 174 | S/F 12\" (305 mm) dia light duty exhaust fan complete with all acccessories (Usha /Bajaj/Orient) etc. |
| 175 | P/F 4 pole 160 Amp. MCCB of break back capacity 25 KA in the existing cubical panel board i/c drilling holes in the cubical panel and making connection as reqd. |
| 176 | S/F 8 way, (2+8 way) single door pole & neutral, prewired, sheet steel MCB distribution board, 240V on surface/recessd complete with loose wire box, terminal block, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnection i/c power painted (but without MCB / RCCB / Isolator) earthing etc as reqd. |
| 177 | S/F (Following rating) double pole 240Visolator in the existing MCB DB complete with connection, testing & commission as reqd. |
| 178 | a.40 amp |
| 179 | b.63 amp |
| 180 | S/F 5-32 amp rating 230 V\"C\" curves MCB for inductive load of the following poles in the existing MCB DB complete with connection, testing & commission as reqd. |
| 181 | a. Single pole |
| 182 | S/F (following piano type switch socket) on the existing switch box/cover i/c connection as reqd. |
| 183 | 1.5/6 amp switch |
| 184 | 2.3 pin 5/6 amp socket outlet |
| 185 | 3. 15/16 amp switch |
| 186 | 4. 6 pin 15/16 amp socket outlet |
| 187 | S/F Stepped type electronic regulator on the modular plate switch box i/c connetion but excluding modular plate as per reqd. |
| 188 | Supply and fixing Pre coated electronic box type luminaries with decorative and caps FTL 1x36/40 lamp complete with accessories i/c connection etc as reqd. |
| 189 | S/F 12W LED Bulb. |
| 190 | 15w LED downlighter. |
| 191 | Earthing with copper earth plate 600mm x 600mm x 6mm thick i/c accessories and providing masonaries enclosure and watering pipe etc with charcoal or coke and salt) as reqd. |
| 192 | P/L earth connection from earth electrode with 4mm dia copper wire in 15mm dia GI pipe as reqd. |
| 193 | P/F 4mm dia copper wire on surface or in recessed for loop earthing as reqd. |
| 194 | P/F 200 amp TPN stand ground on load change over switch (compact design) 415/500 V including connection etc as required. |
| 195 | Supply of 50 sqmm 4 core PVC/XLPE insulted heavy duty armoured cable 1.1 KV grade. |
| 196 | 8m steel tubular poles 410 SP-14 |
| 197 | S/F 400w - 240v HPMV lamp. |
| 198 | P/F of fire fighting system |
| 199 | c) Fire hydrant System |
| 200 | d) Automatic Sprinklers System |