Tender For Rate Contract For Maintenance Of Existing Distribution Main / Rising Main / Transmission Main Pipe Line Will All Other Repairing Works Under Jen Section Salawas, jodhpur-Rajasthan

Public Health Engineering Department-PHED has published Tender For Rate Contract For Maintenance Of Existing Distribution Main / Rising Main / Transmission Main Pipe Line Will All Other Repairing Works Under Jen Section Salawas. Submission Date for this Tender is 22-01-2024. Pipe Laying Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

41552469
Tender For Rate Contract For Maintenance Of Existing Distribution Main / Rising Main / Transmission Main Pipe Line Will All Other Repairing Works Under Jen Section Salawas
Open Tender
Indian
Rajasthan
jodhpur
22-01-2024

Tender Details

Tender For Rate Contract For Maintenance Of Existing Distribution Main / Rising Main / Transmission Main Pipe Line Will All Other Repairing Works Under Jen Section Salawas

Key Value

Document Fees
INR 1000 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work:Rate contract for maintenance of existing distribution main / rising main / transmission main pipe line will all other repairing works under JEN Section Salawas
Sl. No. Item Description
1O & M
2PHED O&M BSR 2021 1.1_Repairing of leakage in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE pipe lineup to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost)
3In all type Soil AC/PVC/HDPE pipe
41.1.1.1 50/63/75mm
51.1.1.2 80/90mm
61.1.1.3100/110mm
71.1.1.4 125/140mm
81.1.1.5 150/160/180mm
91.1.1.6 200/225mm
101.1.1.7 250/280mm
111.1.1.8 300/315mm
121.1.1.9 350mm
131.1.1.10 400mm
141.1.2 Add on above item no. 1 for B.T. Road
15Add on above item no. 1 for C.C. Road
16Add on above no. 1 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr.
17Add on above no. 1 item if depth of pipeline is above3.0 mtr.
18PHED O&M BSR 2021 1.2_ Repairing of leakage in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)
191.2.1 In all type Soil
201.2.1.1 80mm
211.2.1.2 100mm
221.2.1.3 125mm
231.2.1.4 150mm
241.2.1.5 200mm
251.2.1.6 250mm
261.2.1.7 300mm
271.2.1.8 350mm
281.2.1.9 400mm
291.2.2 Add on above item no. 2 for B.T. Road
301.2.3 Add on above item no. 2 for C.C. Road
311.2.4 Add on above no. 2 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr.
321.2.5 Add on above no. 2 item if depth of pipeline is above3.0 mtr.
33PHED O&M BSR 2021 1.3 Minor repair of leakages such as lead caulking, plugging, clamping and ring fixing in existing Distribution/Rising Main/Transmission Main AC/PVC/ HDPE/CI /MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as lead wool, white hump, plugs, clamps etc. shall be provided by Department free of cost)
341.3.1 In all type Soil
351.3.1.1 50/63/75mm
361.3.1.2 80/90mm
371.3.1.3 100/110mm
381.3.1.4 125/140mm
391.3.1.5 150/160/180mm
401.3.1.6 200/225mm
411.3.1.7 250/280mm
421.3.1.8 300/315mm
431.3.1.9 350mm
441.3.1.10. 400mm
451.3.2 Add on above item no. 3 for B.T. Road
461.3.3 Add on above item no. 3 for C.C. Road
471.3.4 Add on above no. 3 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr.
481.3.5 Add on above no. 3 item if depth of pipeline is above3.0 mtr.
49PHED O & M BSR 2021 1.4 Replacement of CI/ DI Double flange sluice valves,non return valves,butter fly valves etc. in existing Distribution/Rising Main/Transmission Main pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including providing and fixing MS Nut and Bolt and rubber gasket, dewatering and providing adequate safety arrangement at site and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as Valve, Tail piece, CID Joints etc. shall be provided by Department free of cost)
501.4.1 In all type Soil
511.4.1.1 80 mm
521.4.1.2 100 mm
531.4.1.3 125 mm
541.4.1.4 150 mm
551.4.1.5 200 mm
561.4.1.6 250 mm
571.4.1.7 300 mm
581.4.1.8 350 mm
591.4.1.9 400 mm
601.4.2 Add on above item no. 4 for B.T. Road
611.4.3Add on above item no. 4 for CC Road
621.4.4 Add on above item no. 4 if depth of pipe line is above 1.5 mtr to 3.0 mtr
631.4.5 Deduct on above item no. 4 if valve is fixed at plinth level / platform i.e. no excavation is required
64PHED BSR O& M 2021_ 1.5 Removal of Choking from pipe line, including tree roots, malba, sand and otherby manually or other means, cleaning of line and testing in existing Distribution /Rising Main/Transmission Main AC/PVC/HDPE/uPVC pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost) as per satisfaction of EIC. Rates for per pit.
651.5.1 In all type Soil
661.5.1.1 75 mm
671.5.1.2 90/80 mm
681.5.1.3 110/100 mm
691.5.1.4 140/125 mm
701.5.1.5 180/160/150 mm
711.5.1.6 225/200 mm
721.5.1.7 250 mm
731.5.1.8 300 mm
741.5.2 Add on above item no. 5 for B.T. Road
751.5.3 Add on above item no. 5 for CC Road
761.5.4 Add on above item no. 5 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr.
771.5.5 Add on above item no. 5 if depth of pipe line is above3.0 mtr.
78PHED BSR O & M 2021_1.6 Removal of Choking from pipe line, including tree roots, malba, sand and otherby manually or other means, cleaning of line and testing in existing Distribution /Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit.
791.6.1 In all type Soil
801.6.1.1 80 mm
811.6.1.2 100 mm
821.6.1.3 125 mm
831.6.1.4 150 mm
841.6.1.5 225/200 mm
85250 mm
86300 mm
87Add on above item no. 6 for B.T. Road
88Add on above item no. 6 for CC Road
89Add on above item no. 6 if depth of pipe line is above 1.5 mtr up to 3.0 mtr.
90Add on above item no. 6 if depth of pipe line is above 3.0 mtr
91PHED BSR O & M 2021_1.7 Disconnection of water connection from existing pipe line in all type of soils up to 1.5 mtr depth by digging out suitable size of pit at site of work, with cutting of service line and refixing of clamp revolving it 180 degree refill the pit from excavated sand by ramming it & upto ground level for entire job contractor will use his own T&P & labour.
92Add on above item no. 7 for B.T. Road
93Add on above item no. 7 for CC Road
94Add on above item no. 7 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr
95PHED BSR O & M 2021 _ 1.8 Removal of sluice valve in existing pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)
96In all type Soil
9780 mm dia pipe to 100mm
98125 mm dia pipe to 150mm
99200 mm dia pipe to 250mm
100300 mm dia pipe to 350mm
101400mm
102Add on above item no. 8 for B.T. Road
103Add on above item no. 8 for CC Road
104Add on above item no. 8 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr
105PHED BSR 2021 O & M 1.9 Work of Inter Connection in AC/PVC/HDPE pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost).
106In all type Soil
10780 mm to 110 mm
108125 mm to 165 mm
109200 mm to 300 mm
110Add on above item no. 9 for B.T. Road
111Add on above item no. 9 for CC Road
112Add on above item no.9 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr
113PHED O&M BSR 2021 1.10 Work of Inter Connection in CI/DI/MS pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost).
114In all type Soil
11580 mm to 100 mm
116125 mm to 150 mm
117200 mm to 300 mm
118350 mm to 450 mm
119500 mm to 600 mm
120Add on above item no.10 for B.T. Road
121Add on above item no.10 for CC Road
122Add on above item no.10 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr
123PHED O&M BSR 2021 1.11 Labour charges for removal of complaint of polluted water supply to the consumers
124Survey of the locality of polluted water supply for preliminary assessment of source of pollution during supply hours
125PHED O&M BSR 2021 1.12 Labour charges for digging of pit of suitable size for removal of water pollutiononexisting distribution AC/PVC/uPVC/HDPE pipe linesup to 1.5 mtr depth including cutting of pipe and assessment of direction of flow of polluted water during non supply hours, identifying the source of pollution and repairing of fault in pipe line byfixing of pipe piece with jointing material (pipe and jointing material shall be supplied by department) to make it leak proof and then refilling the pit from excavated sand by ramming it at site of pipe upto ground level. The rate includes all labour charges to complete the work for pipe size
126In all type Soil
12750 to 75 mm
12880-110 mm
129125 to 165 mm
130200 to 300 mm
131350 to 400 mm
132Add on above item no.11.2 for B.T. Road
133Add on above item no.11.2 for CC Road
134Add on above item no. 11.2 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr.
135PHED O&M BSR 2021 1.13 Labour charges for digging of pit of suitable size for removal of water pollution onexisting distribution CI/DI/MS pipe linesup to 1.5 mtr depth including cutting of pipe and assessment of direction of flow of polluted water during non supply hours, identifying the source of pollution and repairing of fault pipe line byfixing of pipe piece with jointing material (pipe and jointing material shall be supplied by department) to make it leak proof and then refilling the pit from excavated sand by ramming it at site of pipe upto ground level. The rate includes all labour charges to complete the work for pipe size
136In all type Soil
13780-100 mm
138125 to 150 mm
139200 to 300 mm
140350 to 400 mm
141Add on above item 11.3 for B.T. Road
142Add on above item no. 11.3 for CC Road
143Add on above item no.11.3 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr.
144PHED O&M BSR 2021 1.14 Restoration of bitumen road by patch work of WBM using crushed / broken aggregate as per the standard specification and consolidation with hand rammer spreading and consolidation of binding material , cleaning of surface of WBM and providing of seal &tack coat as per site condition by using ready cold mixup to the satisfaction of engineer in charge.The rate includes the makingof pit in regular shape, all labour, material and T&P charge complete job.
145PHED O& M BSR 2021 1.15 Restoration of cement concreteroad including making of pit in regular shape, ramming and consolidation of surface, laying, positioning and compactingcement concrete ( M-20 ) minimum thickness 200 mm upto the satisfaction ofengineer incharge.The rate includes the makingof pit in regular shape, all labour, material and T&P charge complete job.
146PHED O & M BSR 2021 1.16Maintenance of pipelines irrespective of size & materialwhich includes Repairing of Bursts & leakages pollution control, survey & removal of choking, disconnection of illegal connections,Collection & recording minimum 10 nos. residual chlorine samples during daily supply timings, interconnections and all works related to pipeline network in existing distribution /rising main pipe lines of all sizes by digging out suitable size of pit in soft and loose soil/ hard soil including cutting of Black top, WBM & CC top of road of any size at work site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material to make repair leak proof and refilling of pit by excavated sand by ramming it at sides of pipes and upto ground level.For entirejobcontractorwillusetheir own T & P. Contractor with his own resources shall arrange de-watering,JCB & Tractor compressor if any and restore any amenity at his own cost damaged while performing the work in this item. The work includes daily patrolling and repair the leakages within stipulated time and complete maintenance of pipe line network of rising and distribution pipeline network within the scope of work for per km pipe line per month. Jointing material shall be provided by the department.
147Minimum labour for a following kms pipelines to be deployed.
1481 km to 50 km -one fitter-II & one beldar
14951 km to 100 km - one fitter-II & Two beldar
150101 km to 200 km - Two fitter-II & Four beldar
151201km to 300 km - Three fitter-II & Six beldar
152301 km to 400 km - Four fitter-II & Eight beldar
153401 km to 500 km - Five fitter-II & Ten beldar
154PHED O & M BSR 2021 5.1 Turning of various sizes of CID Joints Class- 10/ 15 Complete set (Labour Charges), The Joints will be supplied by the Junior Engineer concern of Department and carting to workshop and after turning of these joints, firm is liable to transport upto Junior Engineer concern"s store own his cost.
15580 mm dia
156100 mm dia
157125 mm dia
158150 mm dia
159200 mm dia
160250 mm dia
161300 mm dia
162350 mm dia
163400 mm dia
164PHED O & M BSR 2021 5.2 Threading on GI Pipes different diameter as below (Rate Per Mouth Threading). The Pipes will be supplied by the Department and carting to workshop and after threading of these pipes, firm is liable to transport upto Junior Engineer concern"s store own his cost.
16532 mm
16650 mm
16765 mm
16880 mm
169100 mm
170125mm
171150mm
172PHED O & M BSR 2021_ 5.3 Cutting of GI/MS/CI Pipes of any class as below (Rate per Mouth- One cutting only making two pieces). The Pipes will be supplied by the Department.
17332 mm
17440 mm
17550 mm
17665 mm
17780 mm
178100 mm
179125mm
180150mm
181200mm
182250mm
183PHED O & M BSR 2021 5.4 Welding on M.S./G.I./CI Pipes and other material by Electric Welding, this includes all the material like welding rods/ equipment like welding machine/ generater, if required for job.
184At Workshop
185On Site
186PHED O & M BSR 2021 5.5Providing, Fabrication of Mild SteelPlane Ended/ Flanged Specials like Tees, Bends, Reducers, Enlargers, Plugs, Tail Pieces and Blank Flange made from MS pipes, MS sheet strip and MS Sheet of required sizes by welding, cutting and treading as per site conditions and as directed by the Engineer- In- Charge complete in all respect.
187PHED O & M BSR 2021 5.6 Making Hole (only labour charges) by drill machine in MS/ CI/ DI Pipes and Specials. per hole rate
188Up to 12 mm)dia. Hole
189Above 12 mmdia. Hole.
190PHED BSR O & M 2021 5.7Making of GI Assembly pipe for various sizes including threading, tightening, welding of flange and welding with MS Patti, holes and cable grove making as per required length of 3.00 M/ 6.00 M (Pipse and flangse shall be providedand carting these to workshop by the the department). Length of MS strip will be 100 mm, Width- 20 mm and thickness- 6 mm and to be welded around the strip with pipe and flange. Holes in the flanged will be standard size and above 12 mm dia. in size. After tightening the pipe and flanged, welding will be done at junction of flange and pipe complete in all respect. After preparing of Assembly Pipes, the firm is liable to transport these toconcern"s divisional store own his cost.
19150 mm
19265 mm
19380 mm
194100 mm
195PHED BSR O & M 2021 5.8 Supplying of MS Rods for different sizes of sluice valveand should be supplied as according to size of old rods including material and finishing for the following sizes.
196Sluice Valve Size 80mm
197Sluice Valve Size 100mm
198Sluice Valve Size 125mm
199Sluice Valve Size 150mm
200Sluice Valve Size 200mm
201Sluice Valve Size 250mm
202Sluice Valve Size 300mm
203Sluice Valve Size 350mm
204Sluice Valve Size 400mm
205PHED BSR O & M 2021 5.9 Supplying of Chuck Nut for different sizes of sluice valveand should be supplied as according to size of Check Nut including material for the following sizes.
206Sluice Valve Size 80mm
207Sluice Valve Size 100mm
208Sluice Valve Size 125mm
209Sluice Valve Size 150mm
210Sluice Valve Size 200mm
211Sluice Valve Size 250mm
212Sluice Valve Size 300mm
213Sluice Valve Size 350mm
214Sluice Valve Size 400mm
215PHED BSR O & M 2021 5.10Providing of U Plate (U Stand) for different sizes of sluice valve and should be supplied as according to size of old U Plate including material for the following sizes.
216Sluice Valve Size 80mm
217Sluice Valve Size 100mm
218Sluice Valve Size 125mm
219Sluice Valve Size 150mm
220Sluice Valve Size 200mm
221Sluice Valve Size 250mm
222Sluice Valve Size 300mm
223PHED BSR O & M 2021 5.11 Supplying ofMS Rods and Chuck Nut (Complete Set) for different sizes of sluice valveand should be supplied as according to size of Check Nut including material for the following sizes.
224Sluice Valve Size 80mm
225Sluice Valve Size 100mm
226Sluice Valve Size 125mm
227Sluice Valve Size 150mm
228Sluice Valve Size 200mm
229Sluice Valve Size 250mm
230Sluice Valve Size 300mm
231Sluice Valve Size 350mm
232Sluice Valve Size 400mm
233PHED BSR O & M 2021 5.12 Making Direct Pump Piece with heavy duty pipes (Class- B) and flange (as per table- D)including cutting of pipe, threading welding and MS strip for length - 100 mm, Width- 20 mm and thickness- 6 mm and to be welded around the strip with pipe and flanged. Hole in the flanged will be standard size and above 15 mm in size. After tightening the pipe and flanged, welding will be done at junctin of flange and pipe complete in all respect including cost of material. The Length of Direct Pump Piece will be 30 cm (300 mm).
2342" dia. Size (50 mm)
2352 ½" size (65 mm)
2363" dia size (80 mm)
2374" dia size (100 mm)
238PHED BSR O & M 2021 5.13 Making Reducer Pump Piece with heavy duty pipes (Class- B) and flange (as per table-D) including cutting of pipe, threading welding and MS strip for length -100 mm, Width- 20 mm and thickness- 6 mm and to be welded around the strip with pipe and flanged. Hole in the flange will be standard size and above 15 mm dia. in size. After tightening the pipe and flanged, welding will be done at junctin of flange and pipe complete in all respect including cost of material (Both the larger and smaller pipe will have equal length making reducer). The Total Length of Reducer Pump Piece will be 30 cm (300 mm).
2392x2 ½ “ dia size (50 x 65 mm)
2402 ½ “x 3” dia size (65 x 80 mm)
2412”x 3” dia size (50 x 80 mm)
2423”x 4” dia size (80 x 100 mm)
243PHED BSR O & M 2021 7.1 Leveling with the objective of creating L-Section along the desirecd route taking levels with the help of high precise GPS instrument at a spacing of 100 M or less keeping variation in level with 1.0 M including taking level of Bench Mark, detailing of all existing main physical feature (Road crossing, culvers, Allah, Power Line, Bench Mark, GLRs, Water tank other Goverment structure, Head work) 10-0 M on eiter side of the route submission of 3 sets of colored print of digital drawing of L-Section and plan on a vertical scale 1 Cm = 100 M on A-4 or A-3 size sheets as required by department with standards, title block as approved complete in all respects as per instruction of Engineer In Charge and departmental specifications including man, material Equipment vehicles etc.
244PHED BSR O & M 2021 7.2 Taking spot level of specific point with the help of high precision GPS instrument/auto level in the village with above survey (To be done along with the work in item No. 1 at location more than 3 km away from above)
245PHED BSR O & M 2021 7.3 Construction of Bench Mark Pillars in cement Concrete Nominal Mix M-10 Grade size 0.30x0.30x1.20m, embedded0.90m below natural grounf level with 25mm dia & 500mm long MS bar( ends grounded to plain surface) projecting 50mm above the top of pillars, marking BM number & levels in Red paint on yellow base of approved make complete in all respect as per instruction of EIC & deptt. specification
246PHED BSR O & M 2021 7.4 Survey by Electronic Total Station of village with a view of prepairing" village index plans" indicating roads, streets along with places of importance such as panchayat Bhawan, Hospital, School, Post Office, Temple, Pond, water supplystructure (GLR"s, PSP"s, Pumping Station, no. of connections on existing pipeline, if any) Physical boundary of village, noth etc. including level at some important points with respect to some permanent Bench mark as per direction of engineer Incharge, etc. complete
247RUDIP SOR 2022 19.57 Providing, lowering, laying, aligning, fixing in position and jointing CI D- joint class-10 as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.
24880 mm dia.
249100 mm dia.
250125 mm dia.
251150 mm dia.
252200 mm dia.
253250 mm dia.
254300 mm dia.
255350 mm dia.
256400 mm dia.
257450 mm dia.
258500 mm dia.
259600 mm dia.
260RUDIP SOR 2022 19.58 Providing, lowering, laying, aligning, fixing in position and jointing CI D- joint class-15 as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.
26180 mm dia.
262100 mm dia.
263125 mm dia.
264150 mm dia.
265200 mm dia.
266250 mm dia.
267300 mm dia.
268350 mm dia.
269400 mm dia.
270450 mm dia.
271500 mm dia.
272600 mm dia.
273PHED BSR O & M 2022 1.1 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note: Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
27480 mm
275100 mm
276150 mm
277200 mm
278250 mm
279300 mm
280350 mm
281400 mm
282450 mm
283500 mm
284600 mm
285PHED BSR 2022 1.4 Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984:1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/insert joint/quick release coupler joint/compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes, transportation and freight charges, inspection charges, loading/unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer in-charge of following class and diameter. (excluding earth work). Note: Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.
286HDPE PE-80PN-6
28775 mm dia
28890 mm dia
289110 mm dia
290PHED BSR 2022 1.5 Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984:1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/insert joint/quick release coupler joint/compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes, transportation and freight charges, inspection charges, loading/unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer in-charge of following class and diameter. (excluding earth work). Note: Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M.
291HDPE PE-80PN-6
292125 mm dia
293140 mm dia
294160 mm dia
295180 mm dia
296200 mm dia
297225 mm dia
298PHED BSR 2022 1.13 De-jointing and removing of already laid CI/DI pipes of following diameters in excavated trenches with care, without damaging pipes, CID joints, valves, specials etc. and other materials and then refilling of soil after de-laying and de-jointing of pipelines with proper compaction and disposing of all surplus soil as directed with in a lead of 30 mtr. This also include stacking the pipes with care and transporting the same to div./sub div. store or as directed by EIC with in the division. (Rates are Exclusive of Earth Work)
29980 mm
300100 mm
301125 mm
302150 mm
303200 mm
304250 mm
305300 mm
306350 mm
307400 mm
308450 mm
309500 mm
310600 mm
311PHED BSR 2022 1.15 Laying, Jointing, Testing and Commissioning of uPVC/PVC Pipes (Class-3/4) in assorted length with specials, valves etc. including local handling and transportation from PHED store and then refilling of soil with proper compaction and disposing of all surplus soil as directed with in a lead of 30 mtr as per satisfaction of EIC. (Rates are Exclusive of Earth Work and jointing materials)
31290 mm
313110 mm
314125 mm
315140 mm
316160 mm
317180 mm
318200 mm
319225 mm
320250 mm
321280mm
322315 mm
323PHED BSR 2022 1.19 Providing, lowering, laying and jointing in trenches, standard lengths ISI marked AC pressure pipe class-15 manufactured by MAZZA process as per IS-1592-2003 or amended up to date with AC coupling and EPDM Rubber sealing rings of Type-3 as per IS:5382/1985 (Reaffirmed 1998) or amended up to date, including all taxes, transportation and freight charges, inspection charges, loading/unloading charges, tacking of pipes, labour and material, satisfactory hydraulic testing etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work and specials) Note: These pipes shall only be used for raw water conveyance main from Canal outlet to raw water reservoirs and interconnection works.
324150 mm dia Cl-15
325200 mm dia Cl-15
326250 mm dia Cl-15
327300 mm dia Cl-15
328350 mm dia Cl-15
329400 mm dia Cl-15
330450 mm dia Cl-15
331500 mm dia Cl-15
332600 mm dia Cl-15
333PHED BSR 2022 1.11 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer in-charge.
334MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)
335PHED BSR 2022 4.1 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil
336Add extra for trenches for every additional lift over item no 4.1
337Above 1.5 mtr and up to 3.0 mtr.
338Above 3.0 mtr and up to 4.5 mtr.
339PHED BSR 2022 4.3 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidatingeachdepositedlayerbyramming,wateringetc.andstacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .:
340Ordinary rock
341Hard rock (requiring blasting)
342Hard rock(blasting prohibited)
343Add extra for trenches for every additional lift over item no 4.3
344Above 1.5 mtr and up to 3.0 mtr.
345Above 3.0 mtr and up to 4.5 mtr.
346PHED BSR 2022 4.5 Dismantling of cement concrete pavement for pipe line line and chambers by mechanicalmeansusingpneumatictools,cuttingtheperipheraledgebyCC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters.Measurementfordismantledtrenchtobemade asperstandard trenchwidthspecifiedintenderdocumentandnoextrapaymentshallbe made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
347PHED BSR 2022 4.6 Dismantling of flexible pavement for pipe line line and chambers by mechanicalmeansusingpneumatictools,breakingtopiecesnotexceeding 0.02cuminvolumeandstockpilingatdesignatedlocationsanddisposalof dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.
348Bituminous courses
349Granular courses
350PHED BSR 2022 4.7 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width morethan specified, completeworkasper technicalspecification and scope of work.
351PHED BSR 2022 4.8 Providingandlayinginpositioncementconcreteinspecifiedgradeover prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line andchamberwork.MeasurementforCCworktobemade asperstandard trenchwidthspecifiedintenderdocumentandnoextrapaymentshallbe madebemadefortrenchwidthmorethanspecified, completeworkasper technical specification and scope of work.
352M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
353Plain cement concrete pavementof M-30 Grade
354PHED BSR 2022 4.9 Removing& Re-fixing of Precast concrete interlocking blocks for laying of pipe linebymanualmethod,stackingofserviceable&nonserviceablematerial separately, disposal of dismantled material lead upto 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub baseasdefined.Completejobistobeexecutedasperthedirectionsof Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlockingblock and cost of required new precast concrete interlocking block against damaged, including alllead and lift as per Technicalspecifications. (Interlockingblockmanufacturedbyfully computerizedautomaticstationeryhydraulicvibropressedmachine&full computerizedautomaticbatchingplantofclassA-1asperBS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm)
35560 mm thick.
35680 mm thick.
357100 mm thick
358PHED BSR 2022 4.10 Horizontal directional drilling (by trenchless technology) of suitable dia hole minimum 1.0 mtr below natural ground level in all type of soil under CC/BT roads and pulling HDPE pipes of dia up to 110 mm, which are available in the form of a coil including excavation, shoring/strutting, preparation, maintain the thrust and including, road dismantling, excavation and refilling of drive pit and exit pit, restoration of road cut as per technical specification and scope of work. Excluding cost of pipe line. Note: Trenchless laying shall be done only for laying of pipe line (rising main) and road crossing of distribution pipe line under CC/BT roads.
359PHED BSR 2022 4.11 Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as perHighway/Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water&sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outsideof casing pipeas per technical specification.
360300 mm Dia 8 mm thick casing pipe.
361400 mm Dia 8 mm thick casing pipe .
362500 mm Dia 8 mm thick casing pipe .
363600 mm Dia 10 mm thick casing pipe .
364700 mm Dia 10 mm thick casing pipe .
365PHED BSR 2022 4.12 Removing& Re-fixing of Bricks Kharbanja road by manual means for laying of pipe line, stacking of serviceable & unserviceable material separately, disposal ofdismantledmaterialleadupto50mtr.TheBricks interlocking belaidon average12mmthickbedofmudmortarandthejointstobefilledwith pointingincementmortar1:3.Layingprocedureoncompactedsubbaseas defined.CompletejobistobeexecutedasperthedirectionofEngineerin charge. The rates are inclusive of fixing of minimum 70 percent reusable Bricks andcostofrequirednew FirstclassFPSbricks(min.10.5Mpa)inplaceof damaged bricks, alllead and lift as per Technical Specifications and direction of Engineer in Charge.
366Horizontal aligned Bricks
367Vertical aligned Bricks
368PHED BSR 2022 6.1 Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem-AISI-410, Body Seat ring, Wedge facing ring & Bushes - LTB2/SS, Face to face dimensions as per IS:14846/2000 (amended up to date), Epoxy (Non-Toxic-suitable for drinking water) applied inside and outside, Flanges Drilled as per IS:1538. Nut-Bolt confirming to IS:1363 andIS:1367/CS/galvanised steel Insertion rubber of black EPDM 6mm thick Sluice valves including all jointing&jointing material, labour, testing and commissioningalong with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
369Manually Operated CI Sluice valve of Class PN-1.0
37080 mm HW
371100 mm HW
372125 mm HW
373150 mm HW
374200 mm HW
375250 mm HW
376300 mm HW
377350 mm with Gear
378400 mm with Gear
379450 mm with Gear
380500 mm with Gear
381600 mm with Gear
382PHED BSR 2022 6.3Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type NonReturn Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part-1)/2004 (amended up to date) and of following specifications:Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS:5312 (part-1):2004, Flanges Drilled as per IS:1538. Epoxy (Non-Toxic&suitable for drinking water) applied on body, cover and disc inside and outside. Body seat ring of SS/CS Door face ring- EPDM/ Neoprene (food grade quality), Shaft of SS- AISI- 410, Hinge Malleable cast iron/ SS AISI 316, Bonnet Gasket EPDM, Bush-Leaded tin Bronze/PTET, Gasket EPDM/NBR, Nut-Bolt as per IS:1363 and IS:1367 (galvanised steel), Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification&as per direction of Engineer-in- charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
383Class PN 1.0
38480 mm dia
385100 mm dia
386125 mm dia
387150 mm dia
388200 mm dia
389250 mm dia
390300 mm dia
391350 mm dia
392400 mm dia
393450 mm dia
394500 mm dia
395600 mm dia
396PHED BSR 2022 6.5 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI single Air Valve Flanged/Screwed type of approved makes for following pressure rating &dia complete, confirming to IS:14845-2000 (amended up to date) and of following specifications:Body, Cover and Cowl-Grey Cast Iron as per IS:210- FG 200, Float Stainless Steel AISI 304/IS:3444, Float Guide- HBT1, Body seat ring- Leaded tin bronze/SS, Seal ring and face ring - EPDM/NBR, Ends flanged according to IS 6418 or Screwed type shall have external pipe threads conforming to IS 554 Fasteners-CS Epoxy paint inside outside of food grade safe for drinking water, Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.
397Class PN 1.0
39815 mm S-1 Type
39925 mm S-1 Type
40040 mm S-1 Type
40150 mm S-2 Type
402Class PN 1.6
40315 mm S-1 Type
40425 mm S-1 Type
40540 mm S-1 Type
40650 mm S-2 Type
407PHED BSR 2022 6.6 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS:14845-2000 (amended up to date) and of following specifications: Body, Cover and Cowl-Grey Cast Iron as per IS:210- FG 200, Float- Stainless Steel AISI 304/IS:3444, Float Guide- HBT1.HP Orifice- HTB2/SS, Body seat ring-Leaded tin bronze/SS. Seal ring and face ring- EPDM/NBR, Ends flanged according to IS 6418,Fastners-CS, Epoxy paint inside outside of food grade safe for drinking water,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.
408Class PN 1.0
40940 mm
41050 mm
41180 mm
412100 mm
413150 mm
414200 mm
415PHED BSR 2022 6.7 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications:Governing standard- AWWA C512/ IS:14845:2000(amended up to date),Body, High presure cover, Low pressure cover, Cowl and Joint support ring- Grey cast iron of grade IS:210/FG200, Float- LP ball &HP ball: AISI 304 stainless Steel, Float Guide- HTB1, Seat ring&Gasket- EPDM/NBR, HP Orifice & HP orifice plug: HTB2/SS, Bush: Bronze, Flanges as per IS/ BS, Drilled as per IS:1538. Epoxy paint (Non-Toxic & suitable for drinking water) applied on body&cover inside and outside Fasteners-CS/Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with CI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to date) PN 1.0 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.
416Class PN 1.0
41740 mm
41850 mm
41980 mm
420100 mm
421150 mm
422200 mm
423PHED BSR 2022 6.17Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Enginee. Class PN 1.0
42480 mm dia
425100 mm dia.
426125 mm dia.
427150 mm dia.
428200 mm dia.
429250 mm dia.
430300 mm dia.
431350 mm dia.
432400 mm dia.
433450 mm dia.
434500 mm dia.
435600 mm dia.
436PHED BSR 2022 9.1 Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab, including cost of steel reinforcement, form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as directed by Engineer-in-Charge.
437For Class-AA loading
438Sluice valve chamber of size 1.13 m x0.85 m x1.325 m-for pipe size-upto 100 mm
439Sluice valve chamber of size 1.17m x 0.95m x1.47m for pipe size-from 125-to-150mm
440Sluice valve chamber of size 1.26m x1.185m x1.88m for pipe size-from 200-to-300mm
441Sluice valve chamber of size 1.39m x1.43m x2.245m for pipe size-from 350-to-450mm
442Sluice valve chamber of size 1.61m x1.75m x2.85m for pipe size-from 500-to-700mm
443PHED BSR 2022 9.10 Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab, including cost of steel reinforcement, form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as directed by Engineer-in-Charge.
444For Class-AA loading
445Air valve chamber of size0.9m x1m x1.695m for air valve size-from 50 mm-to-80mm
446Air valve chamber of size1m x1.1m x1.945m for air valve size of 100mm
447Air valve chamber of size1.05m x1.4m x2.42m for air valve size of 150mm
448Air valve chamber of size1.325m x1.7m x2.875m for air valve size of 200mm
449PHED BSR 2022 9.3 Construction of RCC Scour valve chamber wet type for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab, including cost of steel reinforcement, form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as directed by Engineer-in-Charge.
450For Class-AA loading
451Scour valve chamber of size1.13m x0.85m x1.985m for connecting pipe size-upto100mm
452Scour valve chamber of size1.175m x0.95m x2.285m for connecting pipe size-more than 100 mm & upto 150mm
453Scour valve chamber of size1.2m x1.08m x2.485m for connecting pipe size- more than 150 mm & upto 200mm
454PHED BSR 2022 9.4 Construction of RCC Scour valve chamber dry type for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab, including cost of steel reinforcement, form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as directed by Engineer-in-Charge.
455For Class-AA loading
456Scour valve chamber of size1.13m x0.85m x1.985m for connecting pipe size-upto100mm
457Scour valve chamber of size1.175m x0.95m x2.285m for connecting pipe size- more than 100 mm & upto 150mm
458Scour valve chamber of size1.2m x1.08m x2.485m for connecting pipe size- more than 150 mm & upto 200mm
459PHED BSR 2022 9.5 ConstructionofRCCpillarforfollowingsizeofairvalvesincluding earthworkexcavation, RCCM25gradeforbaseslab,verticalpillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work,propercuringofconcreteworkcompleteinallrespectasper standard specifications and drawings and as directed by Engineer.
460Air valve pillarfor airvalves size of 80mmdia
461Air valve pillarfor airvalves size of 100mmdia
462Air valve pillarfor airvalves size of 150mmdia
463Air valve pillarfor airvalves size of 200mmdia
464PHED BSR 2022 6.18 Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer.
46580 mm dia
466100 mm dia.
467125 mm dia.
468150 mm dia.
469200 mm dia.
470250 mm dia.
471300 mm dia.
472350 mm dia.
473400 mm dia.
474450 mm dia.
475500 mm dia.
476600 mm dia.
477PHED BSR 2022 6.19 Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer.
478150 mm dia.
479200 mm dia.
480250 mm dia.
481300 mm dia.
482450 mm dia.
483500 mm dia.
484600 mm dia.
485PHED BSR 2022 6.20 Removing of existing CI/ DI Double flangesluice valves, non returnvalves, butter fly valves etc. in existing Distribution/ Rising Main/ Transmission Main pipe line of following sizes, works include de-jointing of valve, dewatering, taking it out of the pit with adequate safety arrangement at site and then refill the pit from excavated sand by ramming it at sides of pipe & up to ground level. Work shall be done as per specification,scopeofworkanddirectionofEngineer-in-charge.Alloldmaterial shall be removed safely & all old material shall be deposited in Divisional Store.Note: Rates are exclusive of earth work and road cutting.
48680 mm
487100 mm
488125 mm
489150 mm
490200 mm
491250 mm
492300 mm
493350 mm
494400 mm
495450 mm
496500 mm
497600 mm
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy