}

Tender For Rate Contract For Two Years Extendable For The Purchase Of Rapid Or Elisa Rt Pcr Kits And Consumables, rohtak-Haryana

Pandit Bhagwat Dayal Sharma Post Graduate Institute of Medical Sciences-PGIMS has published Tender For Rate Contract For Two Years Extendable For The Purchase Of Rapid Or Elisa Rt Pcr Kits And Consumables. Submission Date for this Tender is 08-03-2024. Medical Test Kit Tenders in rohtak Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

41550768
Corrigendum : Tender For Rate Contract For Two Years Extendable For The Purchase Of Rapid Or Elisa Rt Pcr Kits And Consumables
Open Tender
Indian
Haryana
rohtak
08-03-2024

Tender Details

Rate Contract For Two Years Extendable For The Purchase Of Rapid Or Elisa Rt Pcr Kits And Consumables-Elisa For Ds Dna ( Ce Certified, For Ivd Use ) ( Elisa Kits Should Be Compatible With All Common Elisa Readers And Washers. ) It Should Be Able To Be Stored At 2-30 Degree C, Should Have High Sensitivity And Specificity ( 95% Each ) , And Should Have Shelf Life Of Minimum 18 Months 2. Elisa For Ana ( Antinuclear Antibody Test ) ( Ce Certified, For Ivd Use ) ( Elisa Kits Should Be Compatible With All Common Elisa Readers And Washers. ) It Should Be Able To Be Stored At 2-30 Degree C, Should Have High Sensitivity And Specificity ( 95% Each ) , And Should Have Shelf Life Of Minimum 18 Months 3. 2 Elisa For Anti Cardiolipin ( Ce Certified, For Ivd Use ) ( Elisa Kits Should Be Compatible With All Common Elisa Readers And Washers. ) It Should Be Able To Be Stored At 2-30 Degree C, Should Have High Sensitivity And Specificity ( >95% Each ) , And Should Have Shelf Life Of Minimum 18 Months 4. Elisa For Anti-Acetylcholine ( Ce Certified, For Ivd Use ) ( Elisa Kits Should Be Compatible With All Common Elisa Readers And Washers ) Li Should Be Able To Be Stored At 2-30 Degree C. Should Have High Sensitivity And Specificity ( 95% Each, And Should Have Shelf Life Of Minimum 18 Months 5. 2 Elisa Total Ige- ( Ce Certified, For Ivd Use ) ( Elisa Kits Should Be Compatible With All Common Elisa Readers And Washers. ) It Should Be Able To Be Stored At 2-30 Degree C, Should Have High Sensitivity And Specificity ( >95% Each ) , And Should Have Shelf Life Of Minimum 18 Months 6. Elisa For Anti Musk Antibodies- ( Ce Certified, For Ivd Use ) ( Elisa Kits Should Be Compatible With All Common Elisa Readers And Washers ) It Should Be Able To Be Stored At 2-30 Degree C Should Have High Sensitivity And Specificity ( 95% Each ) , And Should Have Shelf Life Of Minimum 18 Months 7. Rapid Test Crp- ( Ce Certified, For Ivd Use ) 8. Ra Latex Test Kit ( Rapid Test ) ( Ce Certified, For Ivd Use ) 9. Aso Latex Test Kit ( Rapid ) ( Ce Certified, For Ivd Use ) 10. Elisa For Anti Ccp- ( Ce Certified, For Ivd Use ) ( Elisa Kits Should Be Compatible With All Common Elisa Readers And Washers ) It Should Be Able To Be Dored Al 30 Deg Se C. Deuld Have High Sensitivity Anal Specificity ( 95% Each ) , And Should Have Sheft Lite Of M 18 Nmonths 11. Rapid Malaria Antigen Test ( Hrp-2 / Pldh ) Detection- ( Ce Certified. For Ivd Use ) Rapid Test For Dengue Ns1 Antigen And Deferential Detection Of Igm And Igg Antibodies, For All 4 Serotypes ( Den- 1, 2, 3, 4 ) , Highly Sensitive And Specific With Long Shelf 12. 13. P. Elisa For Ttg Iga Antibodies- ( Ce Certified, For Ivd Use ) ( Elisa Kits Should Be Compatible With All Common Elisa Readers And Washers It Should Be Able To Be Stored At 2-30 Degree C. Should Have High Sensitivity And Specificity ( 95% Eachi, And Should Have Shelf Life Of Minimum 18 Months14. Elisa For Ttg Igg Antibodies- ( Ce Certified, For Iv ) Use ) ( Elisa Kits Should Be Compatible With All Comm Should Readers And Washers ) It Should Be Able To Be Stored At 2-30 Degree C. Should Have High Sensitivity And Specificity ( 95% Enchi ) , And Have Shelf Life Of Minimum 18 Months 15. Elisa For Anti-Pr3 ( C-Anca ) Test System Should Have Highly Purified Native And Recombinant Antigen Coated In Micro-Wells Test System Should Not Have More Than 3 Standards / Calibrators. Should Have Total Incubation Time Less Than 80Minutes. Should Be Compatible With All Elisa Readers. Should Have Higher Clinical And Analytical Sensitivity. Should Have Higher Clinical And Analytical Specificity Should Have Shelf Life Of At Least 12 Months When Stored At Temperature Of 2-8 C Elisa For Anti Mpo ( P-Anca ) 16. Test System Should Have Highly Purified Antigen Coated In Micro-Wells. Test System Should Not Have More Than 3 Standards / Calibrators. Should Have Total Incubation Time Less Than 80Minutes. Should Be Compatible With All Elisa Readers Should Have Higher Clinical And Analytical Sensitivity And Specificity Should Have Shelf Life Of At Least 12 Months When Stored At Temperature Of 2-8 C 17. Hiv 1 & 2 Antibodies Detection Qualitative & Rapid Test 1 Lateral Flow Through Chromatography Immunoassay Based., 2. Should Be Able To Detect & Differentiate Hiv I& 2 Antibodies 3. Should Be Able To Detect ( Igg, Igm & Iga ) In Human Serum, Plasma & Preferably In Whole Blood 4. Kit Should Contain All Ready To Use Reagents And Pack Insert & Specimen Transfer Device 5. Storage At 1-30°C 6 Membrane Strip Should Be Precoated With Hiv I Antigen ( Cgp 41, Gp 1201 & Hiv 2 Antigen ( Gp 361 7. Should Have Sensitivity Of 100% 8. Should Have Specificity More Than 99% 9. Testing Time 10-20 Minutes. 10 Shelf-Life Of The Kit Should Be Minimum Of 18 Months At The Port Of Dispatch Or The Consignees End Whichever Is Applicable 11 The Vendor Will Have To Submit Original Packed Sample Testing Kits ( At Least 10 In Number ) Along With The Original Product Brochure For Validity Testing In Room No. 322, Dept. Of Microbiology, Pgims Rohtak On Working Days In Duty Hours Within 10 Days Of The Publish Of Bud Note: Preference Will Be Given To Bidder Who Will Submit Undertaking That They Will Supply Only Nari ( National Aids Research Institute ) Niv, Naco Consortium, Icmr, Nib Noida Approved Lot, Upon Award Of Rate Contract In Compliance Of The Supply Order. 18. Elisa For Glomerular Basement Membrane Igg Detection- Quantitative Ela Technique, Sandwich / Competitive Elisa, Sensitivity 1.0Ug / Ml, Should Have High Clinical And Analytical Specificity, Should Be Compatible With All Elisa Readers 19. Elisa For Human Complement C3-Quantitative Eia, Sandwich / Competitive Elisa, Sensitivity 0.5Ugimi, Should Have High Clinical And Analytical Specificity, Should Be Compatible With All Elisa Readers 20. Elisa For Human Complement C4 Quantitative Ela, Sandwich / Competitive Elisa, Sensitivity 0.313-5Ug / Ml, Should Have High Clinical And Analytical Specificity, Should Be Compatible With All Elisa Readers 21. Elisa For Igm Leptospira Il 18 For Detection Of Le Antibodies To Leptospira Spp. In Human Serum Etc

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-Jan-2024 PREBID MEETING REINVITED Date 21-02-2024
2 02-Feb-2024 PRE BID MEETING CANCELLED ON 05.02.2024 AT 11 AM DUE TO ADMINISTRATIVE. Date 21-02-2024
3 20-Feb-2024 AFTER PREBID MEETING Date 04-03-2024
4 05-Mar-2024 DATE EXTENDED Date 08-03-2024

Key Value

Document Fees
INR 2000 /-
EMD
INR 200000.0 /-
Tender Value
INR 80 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail