Tender For Provision Of Apfc Panel At Electrical Sub Station At Nams., Amritsar-Punjab

Military Engineer Services-MES has published Tender For Provision Of Apfc Panel At Electrical Sub Station At Nams.. Submission Date for this Tender is 05-02-2024. Power Factor Panel Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

41546008
Corrigendum : Tender For Provision Of Apfc Panel At Electrical Sub Station At Nams.
Open Tender
Indian
Punjab
Amritsar
05-02-2024

Tender Details

Tender For Provision Of Apfc Panel At Electrical Sub Station At Nams.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Jan-2024 CORRIGENDUM NO 01 Date 05-02-2024
2 29-Jan-2024 CORRIGENDUM NO 02 Other 05-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 77600.0 /-
Tender Value
INR 38.80 Lakhs /-

BOQ Items

Name of Work : PROVN OF APFC PANEL AT ELECTRICAL SUB STATION AT NAMS
Sl. No. Item Description
1Supply, Install, Testing and Commissioning of factory made outdoor type dust and vermin proof (IP 54 protection) feeder Pillar LT Panel board cubicle double door hinged type of suitable size 415V AC, 50Hz, fabricated of GP/CRCA sheet 3.15mm thick machine pressed and angle iron frame 50mm X 50mm X 6mm grouted in PCC, powder coated in Seven Tank process inside and outside complete including 4 Pole aluminum Bus Bar of size mentioned below mounted on porcelain insulator, concealed hinged door with Sliding door bolt door locking arrangementand enclosed in chamber made out of 2mm sheet thick GP/ CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles/lugs cable gland with open able shutters on both side and comprising of following :-
2APFC Panel Board 120 KVAR:- INCOMING:- (a) Busbar4 Pole, Aluminum, 400 Amps- 01 Set (b) MCCB 250 Amp 4 Pole, 36KA,with adjustable thermal setting alongwith spreader terminal -01No. (c) LED type Phase indicator lamp(RYB)= 03 Nos (d) Digital type multi function meter to measureV,A,F,PF with 250/5 CTs - 01 set. OUTGOING :- (a) MCCB 63 Amp 3 Pole, 16/18KA,with adjustable thermal setting with spreader terminals -04 Nos. (b) MCB 32 Amp TP, 10KA, C Series- 02 Nos. APFC Relay 06 Steps with suitable CTs.- 01 Set. Capacitor, 480 volts, Heavyduty, Cylindrical type :- i) 25 KVAR- 04Nos, ii) 10 KVAR- 02Nos
3KVAR contactor suitable for Capacitor, 480 Volts :- (a) 25 KVAR- 04 Nos, (b) 10 KVAR- 02 Nos Auto / Manual switch - 01 No ON - Indicating Lamp LED type 240 volt AC, Red colour -06 Nos. ON - OFF push button, 240 volt AC, Red / Green colour -12 Nos. Axial air circulation fan, 150 mm dia - 02 Nos. (c) MCCB 63 Amp 4 Pole, 16/18 KA, with adjustable thermal setting alongwith spreader terminals-01No. Note:- (i)The panel Make should be CPRI approved. (ii)Before Placing the order the panel drawing should be approved by Engr-In-Charge. (iii) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B)work inCM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . (iv) The platform shall be of 40 cm below ground level and 60 cm height above ground level . Cost ofPlatform shall be included in the quoted rates.
4Supply, Install, Testing and Commissioning of factory made outdoor type dust and vermin proof (IP 54 protection) feeder Pillar LT Panel board cubicle double door hinged type of suitable size 415V AC, 50Hz, fabricated of GP/CRCA sheet 3.15mm thick machine pressed and angle iron frame 50mm X 50mm X 6mm grouted in PCC, powder coated in Seven Tank process inside and outside complete including 4 Pole aluminum Bus Bar of size mentioned below mounted on porcelain insulator, concealed hinged door with Sliding door bolt door locking arrangementand enclosed in chamber made out of 2mm sheet thick GP/ CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles/lugs cable gland with open able shutters on both side and comprising of following :-
5APFC Panel Board 160 KVAR:- INCOMING:- a) Busbar4 Pole, Aluminum, 600 Amps- 01 Set (b) MCCB 400 Amp 4 Pole, 36KA, with adjustable thermal setting alongwith spreader terminal -01No. (c) LED type Phase indicator lamp(RYB)= 03 Nos d) Digital type multi function meter to measureV,A,F,PF with 400/5 CTs - 01 set. AS OUTGOING :- (a) MCCB 63 Amp 3 Pole, 16/18KA,with adjustable thermal setting with spreader terminals -06Nos. (b) MCB 16 Amp TP, 10KA, C Series- 02 Nos. APFC Relay 08 Steps with suitable CTs- 01 Set. Capacitor, 480 volts, Heavy duty, Cylindrical type :- i) 25 KVAR- 06Nos, ii) 5 KVAR- 02Nos
6KVAR contactor suitable for Capacitor, 480 volts :- i) 25 KVAR- 04Nos, ii) 5 KVAR- 02Nos Auto / Manual switch - 01 No ON - Indicating Lamp LED type 240 V AC, Red colour -08 Nos. ON - OFF push button, 240 V AC, Red / Green colour -16 Nos. Axial air circulation fan, 150 mm dia - 02 Nos. Note:- (i)The panel Make should be CPRI approved. (ii) Before Placing the order the panel drawing should be approved by Engr-In-Charge. (iii) Platform for the feeder pillar board with PCC 1:2:4 15 Cm thick in foundation, Brick (Sub Class B)work inCM 1:6 ,rendering 1:6 on exposed surfaces and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 40 cm below ground level and 60 cm height above ground level . Cost ofPlatform shall be included in the quoted rate.
7Supply laying in replacement & testing cable XLPE insulated PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty)LT 1100 voltgrade with stranded aluminium conductor of size50 sqmm 3.5 core complete, all as specified and directed.
8Supply, laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc. of size 77mm outer dia and 63mm inner diacomplete, all as specified and directed.
9Material and labour for earthingcomplete with galvanized steel earth plate electrode600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized GI strip of size 32 X 6 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut onone end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 cm etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate No 3 of SSR (Part I 2009) complete, all as specified and directed. Note :- All joints either strip to strip or strip to earth plate are fixed with welded joints.
10Material and labourof MCCB Capacity 400 Amp, 36 KA, 4 pole, 415 V, Adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existingLT Panel complete, all as specified and directed.
11Material and labourof MCCB Capacity 250 Amp, 36 KA, 4 pole, 415 V, Adjustable thermal megnate release type with preader and aluminium lugs all as fixed in existingLT Panel complete, all as specified and directed.
12Material and labour for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white , with numeric, letters in Hindi, English and including local language and conventional skull and bones in signal red colour and fixed with MS Clamps, bolts and nuts of approved size for LT, 20x 15 cm size complete, all as specified and as directed.
13Excavation in trenches in soft/loose soil n.exc. 1.5 m wide and n. exc. 1.5 m in depth etc not exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out for laying of cablescomplete, all as specified and directed.
14Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete, all as specified and directed.
15Removal of surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete, all as specified and directed.