Tender For Electrification Of Quarter Nos. 1 To 42 Of B1 Flat In Fact Township Udyogamandal, 2023-24., udyogamandal-Kerala

Fertilisers And Chemicals Travancore Limited has published Tender For Electrification Of Quarter Nos. 1 To 42 Of B1 Flat In Fact Township Udyogamandal, 2023-24.. Submission Date for this Tender is 30-01-2024. Electrification Work Tenders in udyogamandal Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

41542594
Tender For Electrification Of Quarter Nos. 1 To 42 Of B1 Flat In Fact Township Udyogamandal, 2023-24.
Open Tender
Indian
Kerala
udyogamandal
30-01-2024

Tender Details

Electrification Of Quarter Nos. 1 To 42 Of B1 Flat In Fact Township Udyogamandal, 2023-24. Electrification Of Quarter Nos. 1 To 42 Of B1 Flat In Fact Township Udyogamandal, 2023-24, As Per Tender Documents.

Key Value

Document Fees
Refer document
EMD
INR 65000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Electrification of Quarter Nos. 1-42 of B1 Flat in FACT Township Udyogamandal -2023-24.
Sl. No. Item Description
1Erection, Termination and connection of the 4 way/6 way, 3ph ,415 V Horizontal/Vertical double door MCB Lighting DB Having63 A , 4 pole Isolator as incomer and 6 no of 2 pole isolators of rating 40 A for each Quarters and 10 A MCBs for Providing Supply for Stair case and car shed of each quarters. DB shall be mounted either in a concealed way or in suitable frame fabricated by suitable MS angle frame (50 x 50 x 6),epoxy painted(primer + 2 coats) and properly fixed on wall by the contractor , The incomer PVC armoured cable (up to 4 * 50 Sq.mm) outgoing flexible copper cables of 4 Sq.mm, earth cables of size 2.5 Sq.mm for power circuit through 40 A DP to each quarters and out going for staircase and Car shed shall be glanded /terminated and connected using suitable cable lugs /clamps /ties . All Required structural items, DB with DP/MCB s, flexible glands ,suitable PVC Conduits etc, shall be in the scope of the contractor. Existing in-put armoured cable can be used for main supply from Pillar Box . If incomer cable length is not adequate for termination in DB, Cable should be jointed with copper/aluminium flexible cable of size similar to incomer cable by proper lug/ferrules by providing suitable joint box near DB , This also be in the scope of the contractor.All the MCBs,Isolators,RCCBs used inDB should be of Same Brand as of DB Used for this Work. APPROVED MAKE : 1) DB, RCCBs & MCBs : Legrand/Havells/Schneider/L&T
2Erection, Termination and connection of the 16/18 way, single phase ,230 v Horizontal/ Vertical MCB lighting DB having 40A,30 mA RCCB, 40A DP isolators as incomers SP MCBs -10 A-8no (in case 16 way) /10 no in case of 18 way and SP MCBs 16 A -4 no(1 spare), single phase out going circuits, LDB shall be mountedproperly on the wall bythe contractor . Incomer for this DB should Drawn throughConduits Size not less than 20mm from Main DB Fixed in the ground floor by suitable metal saddles spacing not less than 50cm , 4 sq.mm Phase and Neutral Wire and 2.5 Sq.mm for Earth. All Required items for this Work Shall Be in the scope of the Contractor (Including the cementing and finishing of the wall after fixing of the DB)All the MCBs,Isolators,RCCBs used inDB should be of Same Brand as of DB Used for this Work. APPROVED MAKE : 1) DB, RCCBs & MCBs : Legrand/Havells/Schneider/L&T
3Open Conduits Point wiring with individual control For light /Fan/Bell/Stair case and car shed lights /6 A modular plug sockets separately mounted for TV points/Modular switches, using Flexible copper cables 1.5 Sq.mm for control and neutral connection, Through PVC conduits of size not less than 20 mm using metal saddles with spacing not exceed 50 cm as per relevant drawings or instructions from FACT Engineer in Charge . The work shall include wiring along roof /beam/column/ceiling using clamps and drawing wires as required. Preparation and fixing of modular switch boards,switches, cover plates, dummy plates, Etc fixing of ceiling roses on suitable junction boxes , modular step type regulators for fan, drawing of 1.5 Sq.mm earth wires of flexible copper wire of green colour for body earthing of metal clad items ,connecting, testing and commissioning . For wire length greater than 10 m shall be considered as one and half point . All the materials for this Work shall be in the Scope of the contractor( Selection of the switch boards in rooms shall be in the form of requirements to particular room for fans/lights/sockets etc). Color code for Phase Wire :- Red/Blue/Yellow Neutral :-Black Earth :-Green APPROVED MAKE : 1) WIRE : FR wire of POLYCAB/ RR KABEL/ HAVELLS 2) SWITCH, SOCKETS & REGULATORS : LEGRAND- MYRIUS / HAVELS- CORAL, SCHNEIDER-UNICA PURE/L&T-ENTICE 3) CONDUITS SHALL BE OF MEDIUMISI MARKED
4Supply of 6A Modular Switches as spares forthe work specified in ScheduleNo -3 (Brand and type of switches should be exactly same as the switches used for the work specified in Schedule No -3)
5Supply of 6A Modular Sockets as spares for the work specified in ScheduleNo- 3 (Brand and type of socketsshould be exactly same asthe sockets used for the work specified in Schedule No -3)
6Supply of Modular step type regulators as spares forthe work specified in Schedule No - 3 (Brand and type of Regulators should be exactly same as the Regulators used for the work specified in Schedule No -3)
7Open Conduits Point wiring with individual control For 16 A power sockets switches, using Flexible copper cables 2.5 Sq.mm for control and neutral connection Through PVC conduits not less than 20 mm using metal saddles with spacing not exceed 50 cm as per relevant drawings or instructions from FACT Engineer in Charge . The work shall include wiring along roof /beam/column/ceiling using clamps and drawing wires as required Preparation and fixing of modular switch boards, switches, cover plates, dummy plates, Etc. Drawing of 1.5 Sq.mm earth wires of flexible copper wire of green colour for body earthing of metal clad items ,connecting, etc, All the materials for this Work shall be in the Scope of the contractor. For wire length greater than 10 m shall be considered as one and half point.If additional power sockets are provided in same Switch Boards that shall be considered as half point. Colour code for Phase Wire :- Red/Blue/Yellow Neutral :-Black Earth :-Green APPROVED MAKE : 1) WIRE : FR wire of POLYCAB/ RR KABEL/ HAVELLS2) SWITCH & SOCKETS : LEGRAND- MYRIUS / HAVELS- CORAL/SCHNEIDER-UNICA PURE/ L&T-ENTICE
8Supply of 16A Modular Switchesas spares for the work specified in ScheduleNo -7 (Brand and type of switches should be exactly same asthe switches used for the work specified in Schedule No -7)
9Supply of 16A Modular Sockets as spares for The work specified in ScheduleNo -7 (Brand and type of sockets should be exactly same as the the sockets used for the work specified in Schedule No -7)
10Supply and Installation of 20 W LED tube fittings/bells with required clamps/fasteners. Supply of all materials required for the work such as LED Fittings, Bells, clamps and fasteners etc. are under the scope of the contractor. APPROVED MAKE :- LUKER/HAVELLS/PHILIPS
11Supply of LED tube Fittings as spares for the work specifiedin Schedule No-10 (Brand and type of LEDs should be exactly same as the the LED fittings used for the work specified in Schedule No -10)
12Supplyand installation of ceiling fans (1200 mm) .Supply of all materials required for the work shall be under the scope of the contractor. The specification of Ceiling Fan is such that its Service Value should be higher Than 5.5 CMM/Watts. (Refer BEE Guide lines for Service Value and Star Ratings ) APPROVED MAKE FOR FAN :- LUKER/CROMPTON/ USHA/ HAVELLS
13Supply and installation of Angle Batten Holders forRooms , Bathrooms, Stores and Work area. All material required for the work including the Angle Batten Shall be supplied by the Contractor.
14Erection of earth electrodes ,earth cable laying 2 runs of 1 x 16 Sq.mm Aluminium PVC cable,from earthingpit to corresponding 3 phase DB, clamping ,connection and commissioning of maintenance free copper bonded earthling systems of DB -at suitable locations . Installation of earthing system as per the specified condition mentioned above and supply of All required materials for this work such as maintenancefree copper bonded earthing system approved by Kerala State Electrical Inspectorate , compressing of 3 m long, dia not less than 17 mm earth electrode of low carbon steel with 250 micron copper bonding on outer surface with associated items like environment friendly carbon based back fill compound hardware, clamps, binding wires, connection lugs, anticorrosive paint, bitumen , Sand ,cement, Bricks and required length of 1 x 16 Sq.mm flexible Al PVC cable etc as required for this work shall be in the scope of the contractor.
15Rerouting of Power Cables up to 4*50 Sq.mmfrom Existing 3 phase DB to New DB Location as specified by FACT Engineer -in - Charge
16Excavation of new cable trench of size 300 mm * 300 mm [width x depth] in ordinary soils for laying cables. The scope of work also includes refilling and consolidating the trench after completion of the cable laying work.