Tender For Setting Up Of Trade And Export Facilitation Centre By Renovating & Upgrading The Existing District Industries Centre (Dic) At Trichy, trichy-Tamil Nadu

Tamil Nadu Small Industries Development Corporation Limited-SIDCO has published Tender For Setting Up Of Trade And Export Facilitation Centre By Renovating & Upgrading The Existing District Industries Centre (Dic) At Trichy. Submission Date for this Tender is 23-01-2024. Event Management Tenders in trichy Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

41540782
Tender For Setting Up Of Trade And Export Facilitation Centre By Renovating & Upgrading The Existing District Industries Centre (Dic) At Trichy
Open Tender
Indian
Tamil Nadu
trichy
23-01-2024

Tender Details

Tender For Setting Up Of Trade And Export Facilitation Centre By Renovating & Upgrading The Existing District Industries Centre (Dic) At Trichy

Key Value

Document Fees
Refer document
EMD
INR 107000.0 /-
Tender Value
INR 2.23 Crore /-

BOQ Items

Name of Work: Setting up of Trade and Export Facilitation Centre by Renovating & Upgrading the existing District Industries Centre (DIC) at Trichy
Sl. No. Item Description
1Dismantling Floor finish and Vitrified tiles, dadooing walls in cement mortar with Mosaic Tiles / Glazed Tiles / Clay Tiles / Cuddapah Slabs etc., complete
2Dismantling of Pressed Tiles & Weathering Course etc., complete
3Dismantling Reinforced Cement Concrete by manual / by using deploying machineries etc., complete
4Removing of Doors and Windows including removal of frames, hingesand fastenings etc., complete.
5Dismantling Brick / Stone Masonry in cement mortar walls under 3m high etc., complete.
6Earth work excavation for foundation in all kinds of soils and subsoils and to the required depth as may be directed except hard rock requiring blasting but inclusive of shoring, strutting and bailing out water wherever necessary, refilling the sides of foundation and basement with excavated earth in layers of 15cm thick well rammed, consolidated and depositing the surplus earth in places shown with an initial lead of 10 meters and initial lift of 2 meters and clearing, levelling the site etc., complete. (As per TNBP No. 23 & 24)
7Supplying and filling in foundation and basement with Crushed Stone Sand (M Sand) in layers, not exceeding 150mm thickness well rammed, watered and consolidated complying with relevant standard specification etc., complete. (As per TNBP No. 24 & 25)
8Plain Cement Concrete 1:4:8 (One cement, four of M Sand and eight of coarse aggregate) using 40mm gauge hard broken stone jelly for foundation inclusive of dewatering if found necessary, shoring, strutting, side shuttering, ramming, curing and laid in layers not more than 15cm thick etc., complete complying with standard specification. (As per TNBP No. 28)
9Reinforced Cement Concrete 1:1.5:3 (One of cement, one & half of M Sand and three of coarse aggregate) using 20mm gauge HB stone jelly for all RCC items of works excluding centering, shuttering and also cost of reinforcement grill in position but including laying, curing and finishing etc., complete and also fixing fixtures like fan clamps in the RCC floor / roof slab wherever necessary etc., complete complying with standard specifications and as directed by the departmental officers. (As per TNBP No. 30)
10For Foundation and Basement
11For Ground Floor
12Supplying, fabricating and placing Reinforcement Steel of high yeild strength ribbed bar of various diameter and grade confirming to IS1786 of reinforced concrete work.The workincluding decoiling, straightening, cutting, bending, fabricating and placing in position at all levels and floors including lead and lift according to drawings, specifications, etc complete. Supply and use of 18Gauge black annealed binding wire double fold to tie the bars in position, chairs pins, space bars, unauthorised laps which willnot be measured separately neither for payment nor for reconsilation and providing precast cement / pvc coverblocksfor main reinforcement to ensure specifiedcover and as directed. Steel and binding wire will be procured by the contractor at his own cost. (As per TNBP No. 30 & 86)
13Supplying and erecting Centering for sides and soffits including necessary supports and strutting upto 3.29m height as detailed below with all cross bracings using Mild Steel Sheets of size 90 x 60cm and 10 BG stiffened with Welded Mild Steel Angle of size 25mm x 25mm x 3mm for boarding laid over silver oak joists of size 10cm x 6.50cm spaced at about 90cm centre to centre and supported by Casurina Props of 10cm to 13cm dia spaced at not more than 75cm centre to centre etc., complete complying with standard specification. (Payment for centering shall be given after the concrete is laid). (As per TNBP No. 86 & 86A)
14For Plane Surfaces such as column footings, column pedastals, plinth beams, grade beams, staircase steps and other similar woks etc.
15For Plane Surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams and other similar woks etc.
16For Plane Surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing and other similar woks etc.
17Brick Work in Cement Mortar 1:5 (One of cement and five of M Sand) using Fly Ash Bricks of size 230 x 110 x 75mm including curing etc., complete complying with standard specification and as directed by the SIDCO Engineers. (As per TNBP No. 31)
18For Ground Floor
19For First Floor
20Providing suppy and Installation of SPC (Stone Plastic Composite) Flooring as per manufacture specification etc., complete complying with standard specification.(The make and brand should be got approved by Executive Engineer before use on works)
21Paving the floor with Stain Free Nano Polish Vitrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in Cement Mortar 1:3 (One of cement and three of M Sand) 20mm thick and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works). (As per TNBP No. 39A)
22Paving the floor with Pre-polished Concrete Anti-Skid Step Tiles of 20mm thick of approved quality and colour laid using cement mortar 1:3 (One of cement and three of M Sand) base mortar including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.4 Kg/ sqm etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by the Executive Engineer before use on works) (As per TNBP No. 39A)
23Dadooing the Walls with Vitrified Tiles of size 600mm x 300mm x 8mm of approved quality set in Cement Mortar 1:2 (One of cement and two of M Sand) 10mm thick and pointing with white cement using 0.4 Kg / m² including adding suitable colour pigments to suit the colour of tiles including finishing the joints neatly and curing etc., complete complying with standard specifications. (The tiles should be got approved by the SIDCO Engineers before use on the work). (As per TNBP No. 39A)
24Supplying and fixing Granite Slab (Jet Black) of size 18mm to 20mm thick with super fine polished machine cut edges in partition of size 1200mm x 600mm between the urinals in all floors laid over a Cement Mortar 1:3 (One of cement and three of M Sand) 20mm thick, fixing the slab with required cement slurry, laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with matching colouring pigments including labour charges etc., complete complying with standard specification. (The granite slab and other material should be got approved by Executive Engineer before use on work).
25Grooving the granite slab etc., complete
26Providing single nosing for the granite slab by finishing neatly etc., complete
27Supply and installation of Wallpaper of approved colour and texture over the partition / wall / Columns with necessary adhesives as per manufacturers specification. Wall paper should be made of recycled and recyclable materials, scratch resistant and should be suitable for indoor applications. Rate inclusive of transportation, wastages, installation, etc complete., Working at all levels and heights and as directed by Engineer- in- Charge.
28Weathering Course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. (As per TNBP No. 46B)
29Finishing the top of roof with one course of Solar Reflective Ceramic Tiles of size 305mm x 305mm x 7mm of approved quality laid in Cement Mortar 1:3 (One of cement and three of M Sand) 20mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. (As per TNBP No. 39A)
30Providingand fixingsuspendedceilingsystemusing hot dippedgalvanized steel section, exposedsurface chemicallycleaned,cappingprefinishedinbacked polyester paintconsistingofTruloksuspensionsystemof revealed designer grids of white colourwith necessary main runners, cross "T"runnersand wall angles, accessoriesetc. from Armstrong/AMF orequivalentallcomplete as per manufacturer"sspecification.Thesuspensionceilingis filled up with 15mm thick "Dune"board/equivalentboardofsize 600mmx600mm with spacer panel using 12mm thick gypboard to make up for odd sizes along pheripery and also in grids all complete as directed. The rate should include providing clip/lock pin over the web, of "T" section over the Armstrong/equivalent board and additional material like stiffner ply/equivalent material required in cutouts for lightingpoints, AC grills and diffusers etc to prevent from sag/warping of tiles.Necessary extra suspenders and frame shall be provided.Therate should include cost of providing necessary Aluminum box sections as approved byarchitect as a pelmet of shape and profiles as required allaround the perephery of walls/ partitions all complete asdirected.The Gypsum board will be measured under the relevant item of work
31For Ground Floor
32For First Floor
33DOUBLEFLUSHDOOR: Providingsupplyingandfixingflushdoorwith frame. Made by 32mm thick flush door with both side approved laminate andalledgeswith PVCedga bandedtapefinish.Outer framemade by 18mm thick HDFwith laminatefinish. withnecessarylocking arrangementsuchas4nosofhinges,lockwithhandlesetc Theouter frame to be fixed properly from True ceiling. The rate is inclusive of cost of all materials and labour charges.
34SINGLEFLUSHDOOR: Providingsupplyingandfixingflushdoorwith frame made by 32mm thick flush door with both side approved laminate and alledgeswith PVCedga bandedtapefinish.Outer framemade by 18mm thick HDFwith laminatefinish withnecessarylocking arrangementsuchas4nosofhinges,lockwithhandlesetc.Theouter frame to be fixed properly from True ceiling. The rate is inclusive of cost of all materials and labour charges etc complete.
35Supply and Fixing Single leaf single swing flush door with wooden frame and laminate finish and Standard Size.Door Shutter size 7"x 3" : Fabricating & fixing single leaf flush door 32mm thk of apporved make, finished with 1mm thick laminate of marino make & on both sides. aluminium louvers at bottom including all necessery accessories like, Handles,Hinges,Lock,Door Closer, material & Labour etc complete.
36Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.
37Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
38Physically challenge sliding door: Providing and fixing of sliding doors channels of Dorma or approved equivalent make for - 35mm thick solid core flush door. Using SLM 80 Sliding Door System for Timber Door, 2.5 Metre Length SLM 80 Accessories - 1 Set,SLM Track, 2 mts length - 1 No, Mortice sliding door 400 claw bolt, prepared for euro profile cylinder with 55mm backset, 22mm sq forend including strike plate in satin stainless steel with 3025 europrofile cylinder with both side key operations and Escutcheons.flush pull handle for sliding door - Satin stainless steel all necessary approved hardwares as per manufacturer"s standards like approved Sliding gear with tracks and rollers with necessary track cover etc. Rate to include teak wood door frame of size 100 x 65mm, door shutter, sliding track and necessary hardwares etc complete as directed.
39Providingsupplyingandfixingof single / doubleshutterglasseddoor.Madebyaluminiumouterframeand shutterframe with12mm thick toughned glass withnecessary floor springs,locksandhandleareincluded. Outer frame100mm System, using(100mm x 25mm)anddoorjambwithstileshutterof70x45mm,bothside vertical,topandbottom,horizontalwith horizontalcaping.with floorspring,.Finishanodizedsandblastedsatinsilverfinish.with appropriate beading. Note : Glass & Hardware. The rate is inclusive of cost ofmaterials, labour, transport etc. Make: Glass-SG. The door should be got approved from the Executive Engineer before use on work.
40Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work.
41Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
42Supplying and fixing Mild Steel Grills as per the design approved to verandah enclosure or windows, hand rail including one coat of primer and labour for fixing in position etc., complete complying with standard specification and as directed by the SIDCO Engineers. (As per TNBP No. 86A)
43Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
44Manufacturing, supplying and fixing Stainless Steel Hand Rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete
45Plastering the new wall with Cement Mortar 1:5 (One of cement and five of M Sand) of 12mm thick including centering, strutting, finishing and curing etc complete complying with standard specification. (As per TNBP No. 56 & 57)
46Plastering the existing wall with Cement Mortar 1:5 (One of cement and five of M Sand) of 12mm thick including centering, strutting, finishing and curing. The rate includes clean removal of cement plaster from walls etc., complete complying with standard specification. (As per TNBP No. 56 & 57)
47Special Ceiling Plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One of cement and three of M Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing etc., complying with standard specification and as directed by the SIDCO Engineers. (As per TNBP No. 56 & 57)
48Painting three coats of Acrylic emulsion paint to the walls of approved colour over a coat of water based primer including preparation of surface by thorough cleaning and wetting andapplying two coats of Asian/Birla premixed putty as per specification fullyto givean even shadebefore painting and curing as per standard specificationsandas directed.
49Painting two coats of approved Plastic Emulsion Paint of approved quality and shade at all floors in two coats over one coat of primer to give an even shade including scaffolding, curing etc., complete. The rate including all materials for putty, primer, emulsion paint and all labour charges and as directed by the SIDCO Engineers (The quality and colour of the emulsion, putty and primer shall be got approved from the Executive Engineer before use on work). (As per TNBP No. 66A)
50Painting New Iron Work with two coats of best approved first quality and colour of Synthetic Enamel Paint over the existing red oxide priming coat in all floors etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on work). (As per TNBP No. 66)
51Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights. The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc. The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147. Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer
52Supplying & installation of CONVENTIONAL CURTAIN WALL GLAZING, custom designed to withstand wind pressure of 1.5 kPa conforming to IS-875 part III. The glass panels will be mechanically fixedinto the aluminium main frame fixed on mullions (72X55X2mm) & transoms (72x55x2mm) with necessary aluminium pressure plate and cover cap, with standard accessories and hardware of approved make. With microwave cured EPDM gaskets in unexposed area, clamping system with hot dip galvanized brackets, fasteners & anchor bolts of Hilti/Fisher make, nylon separators to prevent bimetallic contact, shims of various thickness to adjust bracket levels, all as per specification and drawing in conjunction.All aluminium extruded profiles confirming to alloy 6063 T6, all as per specification and drawing in conjunction..The grooves are filled with Weather grade silicone sealant. The extruded aluminum section shall be powder coated with approved color. Glass spec : 6mm thick heat strengthened ST series ref glass ( saint gobain) + 12mm air gap + 5mm thick clear toughened glasss )
53FIXEDGLASS PARTITION: Providing & fixing glazed partition comprising of 12mm thktoughned glass using partition framing system; 18mm x 100mm sections on all sides of the glazed partition. Glass shall besecurelyfixedtotheframesusingproprietoryrubbergaskettes. Samples of the sections along with mockup shall be shown for approval before placing orders. Cost of framework to hold glass above false ceiling willbemeasuredseperately.Costtoincludefillingjointswithsilicon sealant where ever applicable. Glass height upto 2400 / 2550 mm based on location in single piece. Mode of measurement: Only visible area of the partition below false ceiling shall be measured and paid for. Fixing detail neededtobeattachedintenderdocument,Allfixingdetailstobe followed as per manufacturers specifications (wood peices to be inserted inthehollowpartoftheframebeforefixing).MAKE:SAINTGOBIAN, ASAHI. AL PROFILE MAKE: BOTTOM LINE, HARD WARE : DORMA, GEZE, OZONE).
54Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat and the rate inclusive of cost of materials and labour etc., complete complying with relevant standard specification and as directed by the SIDCO Engineers.
55Supply and filling brick jally with a ratio of 1:6:8 (One of cement, six of M Sand and eight of brick jally) including materials and labour charges etc., complete.
56Providing and injecting chemical emulsion using Chloropyriphos mixed as a water emulsion in ratio 1:19 or equivalent for antitermite treatment and creating a chemical barrier all round the column pits,wall trenches, top surface of plinth filling,junction of wall and floor ,along the exterior perimeter of the building,expansion joints,surroundings of pipes and conduits etc. all complete as per IS 6313 (part II) 1981.(Plinth area of the building at ground floor only shall be measured excluding yard / open areas).
57Providing and fixing of seamless 12.5 mm thick tapered edge Gypsum board of saint gobain or equivalent make for Partitions conforming toIS : 2095 providing and fixing of frame of any ISI brand , jointing and fixing to a flush finish of tapered square edges of the gypsum board with recommended filler, paper tapes, as per manufactures specification suitably fixed all complete as per drawings,specificationanddirectionoftheEngineer in The Partition shall be of 4skinning Gypsum with Glasswool insulation.
58Supplying and Erecting Pull and Push Type Rolling Shutter with ISI Monogram (Manually Operated upto 8 sqm. area) of approved size and section using 18 GI sheet in stilt floor. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc., complete and as directed by the TANSIDCO Engineers. (As per TNBP No. 84A)
59Conveyance the Surplus Earth to the places shown by the Engineer incharge including loading into lorries, conveying unloading from lorries and spreading in places indicated as instructed by the Engineer incharge with a lead of 9 to 10 km etc., complete.
60External and internal Landscape works: Supply and planting of following list of works and the amount shall be inclusive of labour, Transportation and Maintanance works.
61Red Earth
62Fertilizer
63Cleodendron / Acalypto plant
64Ficus Panda - 2 feet
65Native trees- 10 to 12 feet
66Ground covers
67External and internal Landscape works: Supply and planting of following list of works and the amount shall be inclusive of labour , Transportation and Maintanance works.
68mexican grass
69shrubs
70Rhapix palm
71Exora large - 2 feet
72Pendanus
73Ujjainia
74Supply and fixing , Testing and Commissioning of Type - BSWR PVC pipe confirming to IS 13592 soil & waste pipes jointed with solvent cement of good quality lubricant inclusive of all necessary specials like bends, tees, offsets, junctions, pan connector, cowls etc., laid under floor / under ceiling / on walls with suitable clamps including making bores in masonry etc., and rendering the bores in cement mortar after laying the pipes and specials curing etc., complete. The quoted rate should include necessary supports like hanger supports, grip bolts and clamps etc.,. Fixing of universal clamp for hanging pipeline is done at no extra cost and is included in the cost of installation of piping.(Brand & Specifications as per Design )
7575mm dia
76110mm dia
77160mm dia
78Supply and fixing , Testing and Commissioning of 50mm dia PVC pressure pipes Class-III (6Kg/sqcm) confirming to IS-4985soil & waste pipes jointed with solvent cement of good quality lubricant inclusive of all necessary specials like bends, tees, offsets, junctions, pan connector, cowls etc., laid under floor / under ceiling / on walls with suitable clamps including making bores in masonry etc., and rendering the bores in cement mortar after laying the pipes and specials curing etc., complete. The quoted rate should include necessary supports like hanger supports, grip bolts and clamps etc.,. Fixing of universal clamp for hanging pipeline is done at no extra cost and is included in the cost of installation of piping.(Brand & Specifications as per Design )
79Supply and fixing of PVC self cleansing, deep seal type 110 mm diaNahani trap(heavy quality hopper type) and 75mm outlet with necessary cement concrete, water proofing the internal surfaces of chamber etc., complete as per specifications. depth of trap shall not be less than 125mm.(The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning)
80Supply and fixing of PVC self cleasing, deep seal type 110 mm dia Multi Floor trap (heavy quality hopper type) and 75mm outlet with necessary cement concrete, water proofing the internal surfaces of chamber etc., complete as per specifications. depth of trap shall not be less than 125mm.(The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning) complete
81Supplying, fixing and testing 75 dia PVC "P"trapfor urinals withSS frame and threaded sealed cover ( 100mm x 100mm) with boss connection suitable as per piping detail with fixed in bed of cement concrete. etc., complete.(The frame and grating shall be approved by Architect)
82Supply and fixing of cockroach trap, complete as per specifications. (The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning) complete
83Supplying and fixing MS angle brackets, hangers, supports as required for supporting sewerage watersupply pipes with suitable GI U- clamps, bolts, nuts and washers etc.The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete.
84Supply and fixing of Floor Clean Out (FCO), complete as per specifications. (The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning) complete
8575mm dia
86110mm dia
87Supply, installation and testing ofCPVC pipes and fittingsSDR-11 conforming to ASTM D 2846. CPVC fusion compound shall conform tro ASTM F493. The scope of including, cutting, cleaning and fixing in/on walls under ceiling, on terrace, etc.,. The quoted rate shall include for making necessary chasing, making bores in foundation, walls, slabs, etc., and making good the chased surfaces and bores in cement mortar. Fixing of universal clamp for hanging pipeline is done at no extra cost and is included in the cost of installation of piping. (Internal and Concealed hot water piping)
8815mm Dia
8920mm Dia
9025mm Dia
9132mm Dia
92Supply, installation and testing ofuPVC SCH 40 pipes conforming to ASTM D 1785 and fittings ofASTM D 2467 at 300 psi to 150 psi working pressure. The scope of workincluding, cutting, cleaning and fixing in/on walls under ceiling, on Shaft, terrace, etc.,. The quoted rate shall include for making necessary chasing, making bores in foundation, walls, slabs, etc., and making good the chased surfaces and bores in cement mortar. (Internal and Concealed & external piping). Providing and fabricating MS supports in angle iron/plates pipes, U clamps, bolts, nuts, screws, painting of the sameetc., will be included in the scope of works. Rate is inclusivefilling excavated trench including sand cushion of at least 75mm all around the pipe laid in trenches to the required grade level. Hunching / bedding with PCC 1:3:6wherever required as specified by the Consultant / Engineer-in-Charge at site inclusive of backfilling with excavated earthwith proper compaction etc., (For Domestic water supply pumping line)
9332mm Dia
9440mm Dia
95Supply and fixing of lever operated Gun metal ball valve of approved make , complete.The valve shall be fixed after the union of PVC.The quoted rate shall also include the cost of the union, nipples etc., complete.
9615mm Dia
9720mm Dia
9825mm Dia
9932mm Dia
10040mm Dia
10150mm Dia
102Supplying and fixing the following dia of PVC Specials etc., complete.
103160mm dia PVC Coupler
104160mm dia PVC Tee
105160mm dia PVC Bend
106160mm x 140mm dia PVC Reducer
107110mm dia PVC coupler
108110mm dia PVC Tee
109110mm dia PVC Bend
110110mm x 75mm dia PVC Reducer
111Supplying and fixing the following dia of PVC, uPVC Specials etc., complete.
11275mm dia PVC coupler
11375mm dia PVC Tee
11475mm dia PVC Bend
11550mm dia PVC coupler
11650mm dia PVC Tee
11750mm dia PVC Bend
11875mm x 50mm dia PVC Reducer
11940mm dia uPVC coupler
120Supplying and fixing the following dia of uPVC Specials etc., complete.
12140mm dia uPVC Tee
12240mm dia uPVC Bend
12340mm x 32mm dia uPVC Reducer
12432mm dia uPVC coupler
12532mm dia uPVC Tee
12632mm dia uPVC Bend
12725mm dia uPVC coupler
12825mm dia uPVC Tee
129Supplying and fixing the following dia of uPVC and cPVC Specials etc., complete.
13025mm dia uPVC Bend
13132mm dia cPVC coupler
13232mm dia cPVC Tee
13332mm dia cPVC Bend
13425mm dia cPVC coupler
13525mm dia cPVC Tee
13625mm dia cPVC Bend
13732mm x 25mm dia cPVC Reducer
138Supplying and fixing the following dia of cPVC Specials etc., complete.
13920mm dia cPVC coupler
14020mm dia cPVC Tee
14120mm dia cPVC Bend
14225mm x 20mm dia cPVC Reducer
14315mm dia cPVC coupler
14415mm dia cPVC Tee
14515mm dia cPVC Bend
14620mm x 15mm dia cPVC Reducer
147Supply, Installing, testing and commissioning of15mm CP health faucet of approved make with necessary CP flexible hose 1000mm long nozzle,CP wall flange, CP angle cock etc., (The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning ) Make / Model : Jaquar / Health faucet -ALD- CHR- 585 , Angle cock - 5053 N
148Supply, Installing, testing and commissioning of 15 mm dia CP bib cocks (The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning)complete. Make / Model : Jaquar / CON - 047 KN
149Supplying & Fixingof electrical water heaterof 30 Liters capacity including CP angle valve, connection hose, support etc. Complete
150Supply and fixing of ABS body Liquid soap dispenser with SS screws on the toilet wall. Make / Model : Jaquar / SDR-WHT-DJ0010F
151Supply and fixing of Stainless steel body paper towel dispenser with SS screws on the toilet wall.
152Supply and fixing of ABS body smart flow Hand Dryer with SS screws on the toilet wall. Make / Model : Jaquar / HDR-WHT-M04A
153Supplying, FixingCP toilet paper holder fixed with SS screws complete. Make / Model : Jaquar / AHS-1553
154Supplying, FixingCP twin coat hook fixed with SS screws on to the toilet door. Make / Model : Jaquar / AKP-35761P
155Supply, Installation, fixing,testing and commissioning of WHITE coloured vitreous china WALL MOUNTED EUROPEAN WATER CLOSET WITH open FLUSHING CISTERN with ‘P’or ‘S’ trap, andflush valve, complete with solid plastic seat with cover, C.P. hinges and rubber buffers, 15mm dia Angle stop cock with wall flange, 15mm dia C.P . cold water connection pipe including health faucet, 2 way BIB cock,24" PVC connection,5" grating noway, C.P.bolts and nuts etc,.The workshall includecuttingand making good the walls and floors etc. -In toilets. Model No ( Parryware-C0265 )
156Supplying and fixing in position Indian Water Closet (Oriya Type) of size 580 x 440mm White Glazed Earthernware of approved quality and brand with "P" or "S" Trap conforming to IS with Sand Cushion and forming flooring alround the closet using 40mm Broken Brick Jelly in Lime Concrete 1:2:5 (One of lime, two of M Sand and five of brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI Soil Pipes / PVC Pipes (including the cost of 100mm dia CI Pipe / PVC PIpes of 110mm dia OD for a length of 600mm) by dismantling Brick Masonry Wall / Reinforced Cement Concrete Roof / Floor Slab and making good the dismantled portion to the original conditon with leakages etc., complete complying with standard specification and as directed by the SIDCO Engineers. (The Water Closet should be got approved by the Executive Engineers before use on work). (As per TNBP No. 102 & 103)
157Supply, Installation, fixing,testing and commissioning of wash basin table mounted SENSOR TYPE PILLAR COCK, required cp flanges,angle cock,flexible hose,extension nipples, sensor faucet, 5x5 gratingAGUAR MAKE MODEL NO
158Supply and Fixing wash Basin Mirror as per detailed drawing etc complete and as directed.
159Supplying and fixing of15 mm dia C.P Long body Bip cock with wall flange with Aerator of Essco fittings (Model No.512) including cost of fittings , labour for fixing etc, all complete and as directed by the departmental officers., (The quality and brand of fittings should be got approved from Executive Engineer before use).
160Supply and fixing in position of best Indian make white / colour glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.)
161Supplying and fixing in position of PVC Cylindrical Water Tank of best quality and approved variety of 1000 litres capacity confirming to ISI specifications with necessary inlets and outlets and overflow, cleaning pipe arrangements and labour charges for fixiing in position etc., and properly fixed in the floor top as directed by the departmental officers.
162Visitors chairs : Supplying and Fixing of Visitor chairs,Made up of high quality NYLON MESH back and 40 density molded foam with 12mm thick molded ply upholstered with cotton fabric with Powder coated 25mm round 16 guage metal S type frame for legs.
163Office Chairs : Supplying and Fixing of workstation and office chairs , Made up of high quality NYLON MESH back and 40 density molded foam with 12mm thick molded ply upholstered with cotton fabric with synchro machinesum, adjestable handle, Five prong powder coated metal base with twin castor rubbrised wheels. Final material colour will be selected and approved by Client / Consultant.
164GM Chair : Supplying and fixing of GM High back Chair Made up of high quality NYLON MESH back and 40 density molded foam with 12mm thick molded ply upholstered with cotton fabric with anti shock multi lock synchro with seat slider machinesum, 3D adjestable handle, Five prong chrome coated metal base with twin castor rubbrised wheels. Final material colour will be selected and approved by Client / Consultant.
165BACK TO BACK MODULAR WORKSTATION Supply and fixing ofPanel -Based System 60mm thick partation. x 1200mm ht Made of Aluminium extrusions duly powder coated with 40 microns of your color choice. The frame is fixed with 7.5mm Tiles to the choice of Pre laminated HDHMR Board, Fabric Board, Magnetic Board, and White Board for writing . 100mm skirting will be provided at the bottom of the partition, This system is developed to run the cable ( Power & data) from the bottom to the tabletop level (Universal Cabling System). Necessary provisions will be given to fix table tops with the partition along with 25mm thick Prelam HDHMR Board for vertical supports and workstation table top. All the cutting edges are covered with 2mm thick PVC edge abdning for the visible edges and .45mm PVC edge banding for non visible edges. SIZE: 1200Lx 600W x 1200H Final material colour will be selected and approved by Client / Consultant.
166MSME OFFICE WORKSTATION : Supply and fixing of Desking system with 40 x 40mm MS 18guage pipe for theframe work , powder coated with 40 micron of your color choice. 30mm Panel -Based System thick partation. x 300mm ht Made of Aluminium extrusions duly powder coated with 40 microns of your color choice. The frame is fixed with 7.5mm Tiles to the choice of Pre laminated HDHMR Board, Fabric Board, Magnetic Board, and White Board for writing. Table top 25mm thick Pre laminated HDHMR All the cutting edges are covered with 2mm thick PVC edge abdning for the visible edges and .45mm PVC edge banding for non visible edges. The desking system has the provision for 400 mm modesty panel with 100mm raceway provision to run cables. SIZE: 1200 L x 900 W x 750 H Final material colour will be selected and approved by Client / Consultant.
167Round Discussion Table : Supplying and Fixing of Round Discussion Table , Made up of high quality NYLON MESH back and 40 density molded foam with 12mm thick molded ply upholstered with cotton fabric with synchro machinesum, adjestable handle, Five prong powder coated metal base with twin castor rubbrised wheels.( MODEL -VI- 100M) Final material colour will be selected and approved by Client / Consultant.
168STORAGE CUPBOARD: Supplying and fixing of FILE STORAGE ( 4 Feet ). Made up of 18mm thick Pre laminated HDHMR board for the top, doors, verticals, horziontal panels and 7.5mm thick for the back panel. Soft close hinges with required handls and lock with brass keys. All the cutting edges are covered with 2mm thick PVC edge abdning for the visible edges and .45mm PVC edge banding for non visible edges.including all necessary accessories for fixing. Final material colour will be selected and approved by Client / Consultant.
169Conference Table : Supplying and Fixing of CONFIRENCE TABLE. Made up of 36mm(18+18) thick pre laminated HDHMR The Table Top & Legs . and 18mm for the modesty . All the cutting edges are covered with 2mm thick PVC edge abdning for the visible edges and .45mm PVC edge banding for non visible edges. with 8 model manual pop up box for electricals switches.including all necessary accessories for fixing. Size: W 6000 x D1500x H 750 Final material colour will be selected and approved by Client / Consultant.
170GM Table : Supplying andFIxing of GENERAL MANAGER Table. Made up of 36mm(18+18) thick pre laminated HDHMR The Table Top , legs. and 18mm for the modesty side storage top verticals and horziontal and 7.5mm for the storage back and drawer back. All the cutting edges are covered with 2mm thick PVC edge abdning for the visible edges and .45mm PVC edge banding for non visible edges. The side table has the provision for 3 drawer unit with openable shutters with 8 model manual pop up box for electricals switches. Main table Size: W 2840 x D1050 x H 750. Side Table: size: WX1200 x D 800 x H 600. Final material colour will be selected and approved by Client / Consultant.
171Conference room Display Rack : Supplying and fixing of Display Rack ( 7 Feet ). Made up of 18mm thick Pre laminated HDHMR board for the top, verticals, horziontal panels and 7.5mm thick for the back panel. 6mm thick glass with fixing bracket. All the cutting edges are covered with 2mm thick PVC edge banding for the visible edges and .45mm PVC edge banding for non visible edges.including all necessary accessories for fixing. Final material colour will be selected and approved by Client / Consultant.
1723 Seater Sofa : Supplying and fixing of 3 Seater Sofa. Made up of 18mm thick commercial grade ISI make PLY wood with Seaconed and treated wood for the frame work. 40 density PU foam for the seat and back upholstered with artifical leather. 25mm thick Square 18 guage S.S pipe for the bottom frame. including all necessary acessories for fixing. ( MODEL - FANCY -3) Final material colour will be selected and approved by Client / Consultant.
173MOBILE PEDESTAL: Supplying and Fixing of Mobile Pedestal. Made up of 18mm thick Pre laminated HDHMR for the top, verticals, bottom, facia and drawer sides, 7.5mm thick pre lamianted HDHMR for the drawer box and storage back. The Mobile pedestal has the provision for 1 drawer on the top and1 openable shutter . twin castors lockable wheels in the bottom, telescopic channels, lock with brass keys, All the cutting edges are covered with 2mm thick PVC edge abdning for the visible edges and .45mm PVC edge banding for non visible edges. Including all necessary hardware for fixing. Size: W 400 x D 450 x H 650 Final material colour will be selected and approved by Client / Consultant.
174Artificial Plants, (Big size Pot) Supply of Fabric Green Fiddle Leaf Fig With Pot Artificial Plants, (Big size Pot)
175Roller Blinds for windows: Supply and Fixing of Roller blinds for windows made up of aluminium hand wash. Window size as per drawing (Approx. 1.5 Mtr x 1.5 Mtr) Final material colour will be selected and approved by Client / Consultant.
176Display unit : Providing supplying and fixing of Display unit to a width of 300mm as per drawing, but in general it shall be made outof18mmthickHDF onallsidesincludingtop,withintermediate shelves at every 300mm Interval with necessary PVC Edge Band beading and the openable shutter shall be made out of 18mm thick HDFwith necessary edge beadings etc. complete. All exposed surfaces shall be finished with 1mm thick Laminate ofapproved shade finishedRate to include all hardware"s, auto closing cabinet heavy duty hinges, with glass door for eachhandles - of approved make, including locking arrangementswithmasterkeyofapprovedmakeetc.complete. Final material colour will be selected and approved by Client / Consultant.
177Supply and providing of name board made, (DISTRICT INDUSTRIES CENTER) specification and fixed over 4 mm thick aluminium composite material fixed over a back supporting frame of 45X45X5 Mild Steel angle and supported on a mild steel angle post 115 4 mm thickness with a clear height of 2.1 m not less than from the ground level to the bottom of the sign board and 0.9m below ground level. The sign post should be painted and firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45cmX45cinX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer in charge. Letter Type : Aluminum Trimcap letters, Colour: Brushed Sliver | depth 2.5"Front 040 Acrylic MC A Grade Background | Thickness 3mm Base: 3mm acrylic 1" DepthLed: 1.2watts, ADS White Led, 5 year Warranty. SMPS: Ads 400 watts | 2 year Warranty,Wiring & Installation
178Supply and fixing of 18 mm finger joint wood with fixing wooden frame into the uv print jont with ss studs 8 FEET X 4 FEET
179LT PANELS i) All MCCBs shall be fixed type. ii) All panels Incoming MCCBs shall be provided with Microprocessor based release and all outgoing breakers should be provided with adjustable thermal & magnetic release. iii) All panels should be should comply with IS-8623 iv) All breakers should have minimum kA rating as mentioned in BOQ / drawing. On non availability of specified breaker, immediate higher rating breaker must be provided. v) All live parts should be shrouded by FRP transparent polycarbonate sheet of 2mm thick. vi) All panels incoming breaker should have over current, Time adjustable short circuit and earth fault releases (LSIG). vii) All panels outgoing breakers should have over current and time adjustable short circuit. viii) All panels incoming feeder should have Multi function meter with RS 485. ix) Surge Arrester to be provided in all panels incoming feeder. x) All MCCB should have LOTO provision.
180Design, Supply, testing and commissioning of Three compartment cubicle type floor mounting / Wall Mounting single front switch board suitable for top cable entry and comprising of the following, the board shall be fabricated as per the detailed specification enclosed. METERING PANEL Incomer: 125 A TP+N FUSE 1 set - RYB LED type indicating lamps with all other acessories Outgoings: Metering compartment : 125A KWHr- 1No (Space provision for EB Meter Energy meter shall be EB Scope) 1set of 125A/5A CT for metering 125A 4P 36kA MCCB - 1No 1 set - Control MCB with Neutral link. 1 set-ON,OFF,TRIP
181Design, Supply, Installation, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. Incoming: Source - 1 - 125A 4P MCCB 36kA with all connected accessories Source - 2 - 63A 4P MCCB 36kA with all connected accessories Outgoing: 63A TP+NMCCB 36kA - 3Nos. 32A/40A TPNMCCB 36kA - 4Nos. Incoming metre feeder shall be with demand controller, Harmonic THD and individual harmonic display+ Regular parameters like V, I, KVA, KVAR, KW, KWH, KVARh, PF, Freq, Max, AVG etc. All Outgoing Feeders in Main panel shall be with dual Source MFM monitoring V,I, KWH, KVARH, PF with RS 485 BMS integration. All the metres to be wired and terminated at common metre chamber / marshalling feeder of each panel section. 125Amps TPN 36kA aluminium busbars:- All the neutral busbars ( For incomers and Outgoing feeders)shall have same the capacity of phase busbars.
182DISTRIBUTION BOARDS The rate includes necessary connected civil works( If required). PDB - (7 segment DB)- 8 WAY Supply and fixing of 7 segment 8 way 63A TPN MCB sheet steel distribution board (Higher end) with metal door cover surface type fitted with busbars and neutral links with sub incomer and singlephase MCB outgoings . Seperate 4 way provision for accomodating one no. 4 pole incoming MCB and another seperate 4 way provision for accomodating one no. 4 poleRCCB/ELCB(totally 8 ways in one segment) SubIncomer: seperate provision for MCB / Isolators / RCCB / ELCBfor sub incomers in 3 segments Outgoings: 3 x 8 ways in each segment,provision for MCB( totally 24 nos.) with lable holder and provison for taking up cable with the following on wall with earth connection. Incomer: 1No.Four Pole 63A 10kA MCB Sub Incomer : 3 Nos. 63A, 100mA, Double Pole RCCB/ELCB Outgoing : 24 Nos. Single Pole 6A to 32A,10kA MCB
183LDB (7 segment DB) - 8 WAY Supply and fixing of 7 segment 8 way 63A TPN MCB sheet steel distribution board (Higher end) with metal door cover surface type fitted with busbars and neutral links with sub incomer and singlephase MCB outgoings . Seperate 4 way provision for accomodating one no. 4 pole incoming MCB and another seperate 4 way provision for accomodating one no. 4 poleRCCB/ELCB(totally 8 ways in one segment) SubIncomer: seperate provision for MCB/ Isolators/RCCB/ELCBfor sub incomers in 3 segments Outgoings: 3 x 8 ways in each segment,provision for MCB( totally 24 nos.) with lable holder and provison for taking up cable with the following on wall with earth connection. Incomer: 1No.Four Pole 63A 10kA MCB Sub Incomer : 3 Nos. 63A, 30mA, Double Pole RCCB/ELCB Outgoing : 24 Nos. Single Pole 6A to 10A,10kA MCB
184UPS/ELDB (7 segment DB) - 8 WAY Supply and fixing of 7 segment 8 way 40A TPN MCB sheet steel distribution board (Higher end) with metal door cover surface type fitted with busbars and neutral links with sub incomer and singlephase MCB outgoings . Seperate 4 way provision for accomodating one no. 4 pole incoming MCB and another seperate 4 way provision for accomodating one no. 4 poleRCCB/ELCB(totally 8 ways in one segment) SubIncomer: seperate provision for MCB/ Isolators / RCCB/ELCBfor sub incomers in 3 segments Outgoings: 3 x 8 ways in each segment,provision for MCB ( totally 24 nos.) with lable holder and provison for taking up cable with the following on wall with earth connection. Incomer: 1No.Four Pole 40A 10kA MCB Sub Incomer : 3 Nos. 40A, 30mA, Double Pole RCCB/ELCB Outgoing : 24 Nos. Single Pole 6A to 20A,10kA MCB
185ELDB - SPN DB Supply, fixing of single/double door type 8 Way SPNMCB DB in flush with wall and making good of the concealed portion with earth connection comprising of the following : (Higher End) Incomer: 1No. Double Pole 25A, 10kA MCB Sub incomer 1No.Double Pole 25A 30mA,RCCB/ELCB Outgoing : 4 Nos.Single Pole,6A to 32A,10kA MCB
186ISOLATORS & PUSH BUTTON STATION: Design, Supply, Installation, testing and commissioning of MS powder coated isolator boxes Wheather proof and the boxes shall be fixed in floor/wall with suitable MS frames. The boxes should have suitable knock out provisions for cable IN and OUT and earth connecting terminals in both the sides. 10/16/20/32A 4P MCB(D-Curve) with connected accessories.
187Supply and fixing of 63A 4P 300mA RCBO with weather proof enclosure with connected accessories.
188CABLES AND TERMINATION The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. Supply, laying , testing and commissioning of the following size XLPE / PVC, (FRLS) insulated outer sheathed (1100 V grade) copper conductor armoured cable laid in cable tray / clamping in wall/ laid in the cable trench with suitable dressing tags and clamps. Cable tray will be measured and paid separately.
189Supply and clamping of 4x150 sq.mm. XLPE LTUG Al armoured cable on post /on wall/Tray with MS clamps
190Supply and clamping of 4x50 sq.mm. XLPE LTUG Al armoured cable on post /on wall/Tray with MS clamps
191Supply and clamping of 4x25 sq.mm. XLPE LTUG Al armoured cable on post /on wall/Tray with MS clamps
192Supply and clamping of 4x16 sq.mm. XLPE LTUG Al armoured cable on post /on wall/Tray with MS clamps
193Supply and clamping of 4x6 sq.mm. XLPE LTUG Cu armoured cable on post /on wall/Tray with MS clamps
194Supply and termination of the following size cables with suitable double compression glands with suitable size PVC boot and suitable crimping socket, gland earthing by using copper flexible and all other necessary accessories . (copper sockets for copper cables and aluminium sockets for aluminium cables)
195Supply and fixing of brass cable gland with end termination for 4CX150sq.mm. XLPE armoured LTUG cable with earth connection
196Supply and fixing of brass cable gland with end termination for 4CX50sq.mm. XLPE armoured LTUG cable with earth connection
197Supply and fixing of brass cable gland with end termination for 4CX25sq.mm. XLPE armoured LTUG cable with earth connection
198Supply and fixing of brass cable gland with end termination for 4CX16sq.mm. XLPE armoured LTUG cable with earth connection
199Supply and fixing of brass cable gland with end termination for 4CX6sq.mm. XLPE armoured LTUG cable with earth connection
200EARTHING ,CABLE TRAYS AND MS ITEMS The rate includes necessary connected minor civil works and insulator supports and heat shrinkable sleeves are to be provided as required at site. No extra payment will be made for the same. Supply erection testing and commissioning of Maintenance Free Earthing system comprising of 14.2 mm dia 3 mtr long Earth electrode of low carbon steel electrode with 250 micron copper bonding & 1 bag of Carbon basedEcosafe environment friendly backfill and suitable clamp, as per IS 3043.CPRI test report should be produced at the time of supply including the inspection chamber, cover HDPEcomplete set.
201Supply and laying of 25 x 3 mm GI flat
202Supplying and laying 8 SWG Hard drawn CU wire including connection/ terminationetc. as required.
203Supply and Installation of MS flat / angles / channels supports for various purpose if required with various sizes including cutting,welding,grinding,fixing accessories and one coat of primer & two coats of enamel paints, minor civil works like grouting existing floors and walls etc. as required.(Note: The flat / angles/channels weights will be arrived on the basis of theoretical calculation only).
204Supply and laying of the 6A/10/13Amps power socket using 3C X 2.5 sqmm copper flexible cable (FRLS) in existing raceway / conduits (under floor) with all other necessary accessories. (The outer sheath colour of cable shall be white for UPS wiring and Black for Raw power wiring)
205Supply and laying of the 16A/20A power socket using 3C X 4 sqmm copper flexible cable (FRLS) in existing raceway / conduits (under floor) with all other necessary accessories. (The outer sheath colour of cable shall be white for UPS wiring and Black for Raw power wiring)
206Supply and run of 2 of 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable gauge MS conduit pipe on wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour
207Supply and run of 2 of 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable heavy gauge MS coundit pipe on wall and ceiling with continous earth wire connection of 14 SWG TC wire with painting of suitable colour
208Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box in flush wall with 6A one way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 14 SWG TC wire forOpen MS conduit Light point / fan point (for electronic regulator) (5 points / Coil) Higher End
209Supply and fixing of 1 no.6A two module 5 pin socket , 1 no.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher EndSD 464
210Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End SD 488
211Supply and fixing of 3nos.6A two module 5 pin socket , 1 nos.16A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End (SD-476)
212Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End (SD-470)
213Supply, fixing, testing and commissioning of 2 nos. 6 A Socket controlled by 1 No. of 10A switch and another 2 modules of provision for RJ45 & RJ11 socket in suitable size POP UP Box (8M) on table top with suitable installation kit and all other necessary accessories as required.
214Supply, fixing of the following GI Channel including stiffner at required intervals in recessed system in floor including floor/wall cutting ,chipping, removal of debris,plastering in the floor/wall to make good finish and to match with the original surface etc. (The thickness: 2mm for Top & Base and 1.6mm for sides)
215100 mm x 38mm
216250mmx250mmx50mm MS junction box
21732mm PVC conduit
21825mm PVC conduit for Flooring(Data)
21925mm MS conduit for Flooring
220LIGHTING INSTALLATION: The rate includes necessary connected minor civil works if required at site. No extra payment will be made for the same. The rate shall be inclusive of suitable MS supports, GI Clamps and wire cable hangers/supports with crimp arrangementand chain suspenders. The height of the hanging arrangement shall be as per drawing and with all accesories to fix the hangers at purlin, rafter beam, MS supports and walls with required clamps nuts & bolts to be considered. Fixing, testing and commissioning of the following light fittings with all other necessary accessories.
221supply and fixing of 36W LED2x2 square type Recessedfitting with LED (Higher end) on false Ceiling with suitable hanging support from ceilingwith PVC unsheathed copper leads from terminals to the fitting.
222supply and fixing of 18W LEDRound type Recessedfitting with LED (Higher end) on false Ceiling fromceilingwith PVC unsheathed copper leads from terminals to the fitting.
223supply and Installation, testing and commissioning of 36W LED Industrial type light fitting with all accessories as required as per the site condition.
224supply and Installation, testing and commissioning of 5W Strip light fitting with all accessories as required as per the site condition.
225supply and fixing of 1200mm (48") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 300mm down rod on the existing fan clamp
226Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete without provision of hole in the wall
227Supply & Installation of rubber mats as per CEIG requirement"s (As per CEIG norms/panel dimensions length and width to be provided)(2x1)meter
228Supply & Installation of first aid kit with wall mounting iron stand.
229Supply & Installation of shock treatment chart in English and Local language. Shock treatment chart to be printed & framed with glass front size 300 x 600.
230Supply erection testing commissioing of 5kVA UPS with 15Minutes battery back up and battery stand complete set. The UPS should be with 3Ph as I/C and 3Ph out put
231Supply, installation, testing and commissioning of single phase input and single phase out put 2kVA UPS system with 1 Hours Battery backup withnecessary accessories and tools as required as per site condition.
232Existing DG repair works
233VRF SYSTEM Note: VRF Units shall meet minimum efficiency requirements as per latest ECBC norms. EER & IEER values as specified in ECBC to be met or as per latest BIS standards, if theyare more stringent. Supplying, installation, testing and commissioning of Air Cooled Variable Refrigerant Volume System suitable for R410A and 415V, 50 Hz, AC supply. The unit shall consist of indoor units and external condensing units and other accessories complete in all respects. The unit shall be fully charged with gas and oil. Supply & Installation, testing and commissioning of Outdoor units consists of 100% inverter compressors, condenser fan motor with variable speed controllers & aero-spiral fan blade and, e-pass heat exchanger, safety valves, solenoid valves, receiver, capillary tube, check valve, electronic expansion valve, high pressure switch, low pressure sensor, pressure regulating valve, refrigerant filter, stop valve, accumulator and refnet kits. The COP of the VRF system shall be minimum 3.5 at AHRI condition.
234Rate shall be inclusive of R-410A refrigerant & oil pre charging, vibration isolators, supports, necessary mounting brackets/ pedestal works etc. The outdoor unit shall be sized to deliver following rated capacities at 40 deg C ambient condition which excludes de-rated capacity due to excess length of refrigeration pipes, change in indoor dry bulb & wet bulb temperature. All the compressors shall be rated for continuous operation. As per specification & tender drawings. All the units shall be provided with built-in microprocessor control panel, for automatic operation and capacity control. Machines shall be suitable for working with BMS system. Each VRF module must have accumulator to handle liquid and safe guard compressor against liquid flood back due to dynamic load condition.
235VRF system shall have auto Restart function i.e.In case of power failure, units should restart automatic when power resume. VRF system shall have auto bypass i.e. If any one IDU have any electric or PCB failure, rest of the system should continue to operate. The VRF system shall have free phase technology, which shall correct phases automatically in case of phase reversal. Below Mentioned single ODU Models should be able to make module combination. 30 HP
236Supplying, installation, testing and commissioning of Wall Mounted Type Metallic body Indoor Units each complete with coil, filter, cordless remote etc. Air conditioners with evaporating unit comprising of cooling coil, blower with motor and 220 volt, 1 phase, 50 Hz, AC supply all and as per specifications. The rate will also include for complete indoor unit supports. 1.03 TR
237Supplying, installation, testing and commissioning of Ceiling Suspended Cassette Type Metallic body Indoor Units each complete with coil, filter, etc. Air conditioners with evaporating unit comprising of cooling coil, blower with motor and 220 volt, 1 phase, 50 Hz, AC supply all as per specifications. The rate will also include for complete indoor unit supports. 2.6 TR
238Supply, installation, testing, and commissioning of Imported fittings Y-joints, distributor and headers for all Indoor units as per layout drawings.
239Supply, installation, testing and commissioning of Corded/Cordless Remote controllersfor operation of indoor units
240Supply, installation, testing & commissioning of Touch Screen TypeCentral Controller capable of controlling of all IDUs of 128 Nos complete with necessary hardware, accessories etc. to perform the following functions: Controlof IDUs, ODUs Units as above with monitoringof vital parameterssuch as temperaturesensing & setting, ON/OFF, status etc. Operation of units in individually or in group Fault indication with Alarm Scheduling of units The central controller will be complete including all hardware & software (including wiring) suitable to perform above function. The Controller should also be compatible for IoT ( Internet of Things) and canbe accessed through Mobile / Laptop / Tablet through remote monitoring and controlling.
241Supply,Installation,testingandcommissioningincluding vaccumiazationandNitrogentestingoffollowingnominalsizesof soft/hard drawn copper refrigerant piping for VRV/VRF system, completewithfittings,withsuitable size cable tray/adjustableringtypehanger supports, jointing/brazing including accessories All connections of Refrigerant piping shall be in high grade Copper of Refrigeration quality with Eddy Current Testing and material test Certificates. Nitrle rubber insulation for Refrigerant pipes 6.4mm to 22.2 mm copper pipes - 13 mm thick insulation Above 22.2mm copper pipes - 19mm Thick Insulation
2426.40 mm dia
2439.50 mm dia
24412.70 mm dia
24515.90 mm dia
24619.10 mm dia
24722.20 mm dia
24828.60 mm dia
24936.90 mm dia
250Supply,installation,testing and commissioning of UPVC drain piping complete withfittings, supportsas perspecifications anddulyinsulatedwith9 mmthick closed cell elastomeric nitrile rubber or XLPE cladded with 26Galuminium sheet.
25125 mm ID
25250 mm ID
253Supplying, installing, testing and commissioning of Shielded control cum transmission wiring of 2 core x 1.5 sqmm (Unarmoured) copper FRLSH, XLPE insulated cable in suitable GI conduits accessories between indoor and outdoor units. Necessary securing of conduit shall be made by contractor. After completion of work wall and floor shall be repaired and brought to its original finish. The rate will also include cost of laying of GI conduit between indoor and outdoor units.
254Providing additional R410A gas charging for the ODU units
255Supplyandfixing of Profile design Cable Ladder with horizontal & vertical bends, reducers, Tee"s,Cross over, supports, brackets and other accessories as required confirming to IS/ IEC-61537.The Cable Ladder shall be made of1.6mm thick.The cable Ladder shall bePregalvanized for corrosion protection confirming toDIN EN 10346 / ISO 1461 .The cable ladder should be tested for safe working load and cable ladder shall be supplied in standard length.
256150mm wide 50mm height
257300mm wide 50mm height
258Supply and Installation of MS flat / angles / channels supports of various sizes including cutting, welding, grinding, fixing accessories and one coat of primer & two coats of enamel paints, minor civil works like grouting existing floors and walls etc. as required.
259Supply, Installation,testing and commissioning of Drain Pump with accessories
260Supplying, installing, testing and commissioning of 2 - Zone Conventional Fire Alarm Control panel with 48 hours battery back up for normal operation.
261Supply, installation, testing and commissioning of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.
262Supply, installation, testing and commissioning of Manual Call Point (MCP) providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers.
263Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers
264Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall usingfixing accessories like screws, plug, clamps, etc.,
265Supply and fixing of 4 Nos fire bucket made out of 40 x 40 x 6mm with MS angle etc,
266Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc, complete as per standard specification and as directed by the SIDCO Officers.
267Supply and fixing of Carbon-di-Oxide Gas Type 4.5 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc., complete as per standard specification and as directed by the SIDCO Officers.
268Providing and fixing in position the signage of " Fire Extinguisher " to be pastedabove the every extinguisher.Size 6" x 8"
269Providing and fixing in position the signage of " Manual Call Point " to be pasted above the every MCP.Size 6" x 8"
270Providing and fixing Floor indentification signage (i.e, GROUND FLOOR… ETC.,) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5cm with contrasting colour from back ground. Size shall be 15cm * 60cm.
271Providing and fixing in position the sign boad of Autoglow " EXIT " with arrow to be placed at walking pathways by hanging on ceiling to direct occupants to outside the building in an emergency. The exit sign board will be auto glow photoluminiscent type which will glow at dark. Size shall be 15cm * 60cm.
272Supply,Installation,Testing and Commissioning ofof6W Ceiling / Wall mounted Mounted Speakers with line matching transformers as specifiedas per specifications
273Supply,Installation,Testing and Commissioning of controller with 6 Zone Call Station as per specifications.
274Supply,Installation,Testing and Commissioning of 240 W Power Amplifieras per specifications.
275Supply,Installation,Testing and Commissioning ofDesktop Microphone as per specifications.
276Supply,Installation,Testing and Commissioning of Rack MountedDVD Player as per specifications
277Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.
278Supply and laying of 4-pair, Cat6A UTP Cable.
279Supply and Installation of 2 Port Faceplate (Voice)
280Supply, Installation, Testing and Commissioning of RJ-45 Information Outlet (Work Station End)
281Supply of CAT6 Patch chord - 2 Meter length (Work Station end)
282Supply of CAT6 Patch chord - 1 Meter length (Rack end)
283Supply and Installation of 24 port loaded CAT6 patch panel
284Supply, Installation, Configuration, Testing and Commissioning of IP PBX Server with minimul 25 IP Extensions expandable upto 300 IP extensions, and 5 Analog Trunks. Capable to add SIP, additional Trunks and PRI in addition
285Supply and Installation of single port faceplate (Data)
286Supply, Installation, Testing and Commissioning of 24 port managed network switch
287Supply, Installation, Testing and Commissioning of 36U Rack Frame 600X600 size with Caster wheels Black powder coated Front Glass Door, Rear Metal Door removable side panels with adequate cable manager, PDB etc
288Supply, Installation, Testing of Fan for the 36U Rack
289Supply, intallation, testing and Commissioning of the 8 Channel DVR
290Supply, intallation, testing and Commissioning of 2 M.P Dome Camera- 2.8mm lens
291Supply, intallation, testing and Commissioning of 2 M.P Bullet Camera -2.8mm lens
292Supply, intallation, testing and Commissioning of 8TB Survilence Hard Disk
293Supply and laying of 2+1 Coaxial cable
294Supply and laying of 25mm PVC Conduit
295Supply, intallation, testing and Commissioning of 9U Rack
296Supply, intallation, testing and Commissioning of 8 Port PoE SWITCHES FOR CCTV IP CAMERA - HIGHER END
297Supply and installation of RC Connector
298Supply and laying of Cat 6 Cable
299Supply, Installation, Testing and Commissioning of Computer with Mini PC with Intel Core i3 Processor, 8GB RAM and minimum 256GB SSD with 2 HDMI Display ports and wireless keyboard and Mouse - to connect with Video Conferene Systems
300Video Conferenceing System for Conference Room Confernce Room Video Conferencing System with 10x lossless zoom, and HD 1080p/30 performance Camera with Speakerphone Features Video conferencing solution for rooms that seat 25–30 people, high quality HD video and crystal clear audio, allowing any meeting place to be a video conferencing space. Advanced features like acoustic echo cancellation, noise reduction technology, and intuitive controls The Unit to be USB plug-and-play connectivity with conference room computer or laptop through USB, with any video conferencing software also it is compatible to pair mobile device with Bluetooth® wireless technology to the GROUP speakerphone. Table / Tripod / Wall mountable cameral. Optional expansion mics to extend audio coverage up to 8.5 meters.
301Supply & Fixing of 65" UHD Commercial Display
3023600 ANSI lumens LCD Projector FHD (1920 x 1080) resolution Ratio : 16:9 Full HD (1920 x 1080) Up To 100 (254cm) Screen Size
303100"size Motorised Projector Screen
30430 Mtrs HDMI Cable
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail