| 1 | Taking down carefully (copper/aluminum) point wiring complete of any type (batten/surface conduit) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 2 | Material and Labour for point wiring complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable (FRLS) upto and including working voltage 1100volts grade, drawn through and including PVC casing and caping including all accessories ISI marked including press fit white PVC open switch/surface board high strength and crack resistance and unsheathed copper conductor stranded cable(FRLS) earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly for the following:-. (a ) one light point controlled by one switch 5 Amps |
| 3 | (b ) onefan pointpoint controlled by one switch 5 Amps |
| 4 | (c) One 3pin socket outlet 5 Ampson Independent board |
| 5 | (d ) One 3pin socket outlet 5 Ampsonsame board |
| 6 | ( e) One bell pointcontrolled by one bell push |
| 7 | All as per Item No. 2 above but with 4 sq mm PVC insulated copper conductor cable(FRLS) including 4 sq mmPVC copper conductor used as earth wirefor power point on independent board for One 3 pin socket outlet, 15 Amps. |
| 8 | Supply and fix in repairs Switch piano Flush, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed. |
| 9 | Supply and fix in repairs SSwitchSocket Combination 2 in 1, 5pin 5 Amps flushtype230 Volts, AC, with ISI mark complete all as specified and directed. |
| 10 | Supply and fix in repairs SwitchSocket Combination2 in 1, 5 Amps /16 Ampsflushtype230 Volts, AC, with ISI mark complete all as specified and directed. |
| 11 | Supply and fix in repairs Socket outlet 2 in 1, 5 Amps flushtype230 Volts, AC, with ISI mark complete all as specified and directed. |
| 12 | Supply and fix in repairs Electronic fan regulator 230 volts, step type,socket type, hum free 120 watt ISI Marked complete all as specified and directed. |
| 13 | Supply and fix in repairsCeiling rose in poly carbonate 3 plates flush type 6 Amps, 230 volts AC complete all as specified and directed. |
| 14 | Supply and fix in repairs Bell electric Ding Dong 230 Volts, AC, with ISI mark complete all as specified and directed. |
| 15 | Attending internal/ external electric complaint for maintenance/breakdown, round the clock for maintenance, checking, fault finding and rectification of fault in LT panels/Overhead HT/LT lines, transformers, switchgears and carry out repairs and resume electric supply complete all as specified and directed by Engineer-in-charge.Note:- (a)Day to day complaint rectified by the Electrician shall be written in complaint register and completion report recorded in complaint register and complaint document slip rectified complaints only will be paid.(b) The spares required for the rectification of fault shall be measured under items 12 to 36.(c) 5 Nos complaints will be treated as one job |
| 16 | Supply only Switch piano Flush, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed. |
| 17 | Supply only of Modular switch, one way, 6Amps complete all as specified and directed. |
| 18 | Supply only Modular switch, one way, 16Amps complete all as specified and directed. |
| 19 | Supply only Bell push 5 Amps one way complete all as specified and directed. |
| 20 | Supply only Modular Bell push, 6 Amps complete all as specified and directed. |
| 21 | Supply only Bell electric Ding Dong 230 Volts, AC, with ISI mark complete all as specified and directed. |
| 22 | Supply only Modular socket outlet, 5 Amps, 2 and 3 pin combined complete all as specified and directed. |
| 23 | Supply only Modular socket outlet, 5 Amps/ 16 Amps, 2 and 3 pin combined complete all as specified and directed. |
| 24 | Supply only Modular fan regulator 230 volts, step type, 120 wattcomplete all as specified and directed. |
| 25 | Supply onlymodular white cover plate with frame1 modulecomplete all as specified and directed. |
| 26 | Supply onlymodular white cover plate with frame2 modulecomplete all as specified and directed. |
| 27 | Supply onlymodular white cover plate with frame 4 modulecomplete all as specified and directed. |
| 28 | Supply onlymodular white cover plate with frame 6 modulecomplete all as specified and directed. |
| 29 | Supply only socket outlet 2 in 1, 3 pin, 6/16 Amps flush type complete all as specified and directed. |
| 30 | Supply only socket outlet 2 in 1, 3 pin, 6 Amps flush type complete all as specified and directed. |
| 31 | Supply only Modular SwitchSocket Combination 16 Amps 6 pin complete all as specified and directed. |
| 32 | Supply onlyCeiling rose in poly carbonate 3 plates flush type 6 Amps, 230 volts AC complete all as specified and directed. |
| 33 | Supply only Lamp holders baklite body with back plate suitable for battern fitting/angle fittingcomplete all as specified and directed. |
| 34 | Supply only LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.Make ;CELS ct pt no CLLC-20W or Surya ct pt no SLEBT20GI or equivalant Havells/CG/Philips |
| 35 | Supply only LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V ACdecorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Make Cat pt no BCLSB 10WH of Bajaj / surya SLE BT 10W ARROW or equivalant of Havells/Philips |
| 36 | Supply only LED luminaire 600 mm x 600 mm,40 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.Make: Bajaj/Havells/ CG |
| 37 | Supply only round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Make: Bajaj/havells/CG |
| 38 | Supply only LED bulb 9 watts, 230 volt complete all as specified and directed. Make: Philips/Bajaj/Surya. |
| 39 | Supply only Condenser 2.5 Mfd AC 240V, complete all as specified and directed. |
| 40 | Supply only Condenser 4 Mfd AC 240V, complete all as specified and directed. |
| 41 | Supply and fix MCB SPN, 240Volts, 6 to 32 Amps rating 240 V, breaking capacity of 10 KA, \"C\" Curve complete all specified and as directed. |
| 42 | Supply and fix MCB SPN, 240Volts, 40 to 63 Amps rating 240 V, breaking capacity of 10 KA, \"C\" Curve complete all specified and as directed. |
| 43 | Supply and Fixing MCB TPN 415 Volts, 50Hz, 3 phase of capacity 40 Amps, C curve 10 KA breaking capacity, fixed properly in DB and connecting/testing complete all as specified and as directed. |
| 44 | Supply only energy efficient LED building security light Fitting 60 Watts on existing backets including connection with twin coe flexible PVC 0.5 Sqmm cable complete all as secified and as directed.Make: Havells Cat Part No NDURAOMNIPLUSSL60WLED757SASYTOPC or equivalant in Philips /Wipro |
| 45 | Material and labour for Sub main wiring using two runs of single corePVC insulated cable (FRLS) 6 sqmm copper conductor multi stranded and one run of 6 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including suitable size PVC casing and caping including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note-3 run of 6 sqmm PVC copper wire and One run of PVC casing caping shall be measured and paid as oneunit. |
| 46 | Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 4 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommerDouble door, flush to wall complete all as specified and directed . |
| 47 | Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 8 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommerDouble door, flush to wall complete all as specified and directed . |
| 48 | Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 12 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommerDouble door, flush to wall complete all as specified and directed . |
| 49 | Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, TPN 4 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 415 volts, MCBs used as incommerDouble door, flush to wall complete all as specified and directed . |
| 50 | Supply and fix in repairs single pole andneutral enclouser with a two pin andearth plug and socketcomplete with and including one MCB single pole 20 Amps complete all as specified and directed. |
| 51 | Taking down fan of any type and size after disconnecting, depositing to store yard and Hanging/fixing onlyafter repair/reconditioning fan of any type and size all as directed. NOTE: Repair and reconditioning of fan shall be measured and paid separately under Item Nos. 48 to 51. |
| 52 | Collectingunserviceable ceiling fan 1200mm/1400mm sweep 230V, AC single phase from store yard of AGE E/M and transporting to local market, cutting unserviceablewinding from fan stater & rewinding same with super enamelled copper winding wire of existing gauge size including throughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws, hanging clamps with rubber reel, canopy condensers, bush, bearing & flexible copper connection wire etc complete all as directed.Note : (i) Taking down and refixing after repair work shall be measured and paid under Item No.47 above.(ii) Spare such as Hanging clamps, canopy, condenser and flexible copper connection wire, painting, down rod, bearing, bush, clamps etc shall be measured & paid separatetly under item Nos.53 to 56. |
| 53 | All as per item No48 above but exhaust fan 250 mm sweep |
| 54 | All as per item No48 above but exhaust fan 300 mm sweep |
| 55 | All as per item No48 above but wall fan 450 mm sweep |
| 56 | Material and Labour for Scraping down old paint of exhaust fan/ ceiling fan of any size 250/350/1200 mm sweep complete body & blade including down rod filling the cavitieswith filler and making smooth surfaceby applying sand paper painting the ceiling fan by meansspray gun/brush with synthetic enamel white paint complete all as specified and directed. |
| 57 | Supply only Ball bearing Ser No 6201 or 6202 complete all as specified and directed. Make : MDS/SKF/NBL |
| 58 | Supply only Ball bearing Ser No 6203/6204 complete all as specified and directed. Make : MDS/SKF/NBL or as per existing specifications as per sample |
| 59 | Supply only Gun metal bush for ceiling fan complete all as specified and directed. |
| 60 | Supply only Down rod 300 mm long of size 20 mm dia ISI marked complete all as specified and directed. |
| 61 | Supply and fixing in repairs oscillating mechanism suitable for wall mounting fan any make and typeall complete all as specified and as directed. |
| 62 | Supply and fixing in repair of Exhaust fan Motor of 300mm sweep heavy duty complete as per samplecomplete all as specified and as directed. |
| 63 | Supply and fixing in repair of Exhaust fan Motor of 250mm sweep heavy duty complete as per samplecomplete all as specified and as directed. |
| 64 | Material and labour for servicing including cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil forsplittype AC ofanymake/ capacity aftertaking down the whole unit and refixingat the existing locationor any other new location after servicing allas specified and directed.Note: Spare parts shall be measured and paid separately under relevant item. |
| 65 | Shifting of split type AC existing location/from MES yardto the new locationby takingit afterpumping filling and making good the opening of old location with cement mortor, applying treatment of wall tomatching with existing colour and finish and making opening holes on brick wall at new locationand gap well finishwith cement mortor, applying finish towall tomatch with existing colour of the adjacent surface , installation and commissioningwith replacement of insulationof suctionand discharge line complete all as specified and directed. |
| 66 | Supply and fix in repairs Printed Circuit Board suitable for 2TR CapacitySplit Unit Air Conditioners including remote, etc. all as specified and as directed.NOTE: Make of PCB & remote shall be of existing manufacturer as compatible with the AC. |
| 67 | Supply and fix in repairs Printed Circuit Board suitable for 1.5TR CapacitySplit Unit Air Conditioners including remote, etc. all as specified and as directed.NOTE: Make of PCB & remote shall be of existing manufacturer as compatible with the AC. |
| 68 | Disconnecting, dismantling and taking out existing burnt out compressor fromwindow/Split type Air conditioner 1.5 TR Capacity and supply and fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filledwith compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer complete all as specified and as directed.Make : LG/ Voltas/ Samsung |
| 69 | Disconnecting, dismantling and taking out existing burnt out compressor fromwindow/Split type Air conditioner 2 TR Capacity and supply and fixing sealed unit compresser of existing capacity 2 TR, single phase, 230 V AC supply initialy filledwith compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer complete all as specified and as directed.Make : LG/ Voltas/ Samsung |
| 70 | Disconnecting, dismantling and taking out existing burnt out compressor from water cooler of capacity 40to 80 Ltr per Hour singlephase 230 volts and supply and fixing compressor unit of water cooler of capacity 40 to 60 ltrs complete all as specified and directed.Make :LG/ Voltas/ Samsung |
| 71 | Supply and fix in repairs AC blower fan motor for ACsuitable for 2 TR AC suitable operate on 230 Volt AC supply at 50 Hz complete all as specified and directed. |
| 72 | Supply and fix in repairs AC blower fan motor for ACsuitable for 1.5 TR AC suitable operate on 230 Volt AC supply at 50 Hz complete all as specified and directed. |
| 73 | Supply and fix in repairsblower fan motor water cooler capacity 40/80 suitable operate on 230 Volt AC supply at 50 HZ complete all as specified and directed. |
| 74 | Supply and fix in repairs Capacitor 45 MFD complete all as specified and directed. |
| 75 | Supply and fix in repairs Capacitor 50 MFD complete all as specified and directed. |
| 76 | Supply and fix in repairs insulationNytrile foam insulation suitable for 5/8 inch copper tube as per site requirement of approved makeall as specified and directed . |
| 77 | Supply and fix in repairs insulationNytrile foam insulation suitable for 1/4 inch copper tube as per site requirement of approved makeall as specified and directed . |
| 78 | Supply and fix in repairs Copper tube5/8 inch size as per site requirement of approved makeall as spd and directed . |
| 79 | Supply and fix in repairs Copper tube 1/4 inch size of approved makeall as specifiedand directed . |
| 80 | Supply and fix in repairs Evaporator unit (indoor unit ) complete suitable for 2 TR Capacity Split type Air Conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/ Voltas/Goderj |
| 81 | Supply and fix in repairs Evaporator unit (indoor unit ) complete suitable for 1.5 TR Capacity Split type Air Conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/ Voltas/Goderj |
| 82 | Supply and fix in repairs Condensing (Out door) unit complete including compressor, etc. suitable for 2 TR Capcity Air conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/Voltas/Goderj |
| 83 | Supply and fix in repairs Condensing (Out door) unit complete including compressor, etc. suitable for 1.5 TR Capcity Air conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/Voltas/Goderj |
| 84 | Supply and chargingR-134A/ R-410A gas to maintain the required cooling effect as and when required in the water cooler, Refrigerator and other cooling applinces complete all as specified and as directed. |
| 85 | Supply and fix in repairs electric motor for hangar door rated 10 HP, 3 phase suitable for voltage 415 V +/-10%, frequency 50Hz +/-5%, continuous rating(S1 duty) IP-55 enclosure, 3000 rpm complete all as specified and as directed. |
| 86 | Supply and fix in repair PVC insulated unsheathed flexible cable (FR)1100 volts grade 4 core 2.5 sqmm, multistranded with copper conductors,conforming to IS specifications, with colour code, complete all specified and directed. |
| 87 | Supply and fix in repairs LED highbay light 150 watt energy saving environment friendly and robust LED luminaire with efficacy suitable for ceiling(Surface/suspened) IP65 complete all as specified and as directed. Make: Cat No.RADIOSOHB150WLED75760DBOPC of Havells or equivalent in Crompton Greaves/Philps/Bajaj |
| 88 | Schedule of Credit (Minus) Rs.42180.00NOTE: Bidder shall insert credit amount of Rs. 42180.00 as ratein Green field under Col-13. |