Tender For Repair Replacement Of Joinery Of Wdn Mild Steel And Aluminium Plumbing Sanitary Fitments Tiling Wk And Certain Internal Em Wks And Repair Maint Of Ext Water Supply Lines Ext Electric Supply Wks Periodical Maint Of Ro Plants Acs And Dg Sets, gurgaon-Haryana

Military Engineer Services-MES has published Tender For Repair Replacement Of Joinery Of Wdn Mild Steel And Aluminium Plumbing Sanitary Fitments Tiling Wk And Certain Internal Em Wks And Repair Maint Of Ext Water Supply Lines Ext Electric Supply Wks Periodical Maint Of Ro Plants Acs And Dg Sets. Submission Date for this Tender is 29-01-2024. Diesel Generators Tenders in gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

41526143
Corrigendum : Tender For Repair Replacement Of Joinery Of Wdn Mild Steel And Aluminium Plumbing Sanitary Fitments Tiling Wk And Certain Internal Em Wks And Repair Maint Of Ext Water Supply Lines Ext Electric Supply Wks Periodical Maint Of Ro Plants Acs And Dg Sets
Open Tender
Indian
Haryana
gurgaon
29-01-2024

Tender Details

Repair Replacement Of Joinery Of Wdn Mild Steel And Aluminium Plumbing Sanitary Fitments Tiling Wk And Certain Internal Em Wks And Repair Maint Of Ext Water Supply Lines Ext Electric Supply Wks Periodical Maint Of Ro Plants Acs And Dg Sets At Af Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 81000.0 /-
Tender Value
INR 40.50 Lakhs /-

BOQ Items

Name of Work : REPAIR/REPLACEMENT OF JOINERY OF WDN, MILD STEEL AND ALUMINIUM, PLUMBING, SANITARY FITMENTS, TILING WK, AND CERTAIN INTERNAL E/M WKS AND REPAIR/MAINT OF EXT WATER SUPPLY LINES, EXT ELECTRIC SUPPLY WKS, PERIODICAL MAINT OF RO PLANTS, ACS AND DG SETS AT AF STN DHANSA UNDER GE AF GURGAON
Sl. No. Item Description
1Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
2M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:6)for bedding of tilescomplete all as specified and as directed.
3M&L for 10 mm thick rendering in cement mortar (1:4) on vertical surfaces for backing of tiles complete all as specified and as directed.
4M&L for joint free Non- skid ceramic coloured tiles 7 to 8mm thick (Square/ rectangular) area of each tile exceeding 0.11 but n.exc 0.18 Sqm, in floors/shirtingetc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
5M&L for ColouredVitrifiedCeramic tiles 9-10 mm thick (Square/rectangular) oflight Shade , polished, area of each tilenot exceeding 0.36 sqm, fixed in floor/skirting etc overset and jointed in neatcement slurry and pointed in coloured cement to match with coloured tiles complete all as specified and as directed.
6M&L for joint free Glazed ceramic coloured/ printed tiles in vertical surface of size 350x 250 x 6-7mm/450x 300 x 6-7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match on walls as in dado/ skirting etc complete all as specified and as directed.
7Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
8M&L for 25 mm thick PCC 1 :2 :4type B-0 (using 12.50 mm graded stone aggregate) as in flooring finished even and smooth without using extra cement complete all as specified and as directed.
9M&L for 40mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in flooring finished even and smooth without using extra cement complete all as specified and as directed.
10M&L for 75 mm thick cement concrete (1:4:8) type D-2 with using 40 mm graded stone aggregates) asin sub base of flooing etc complete all as specified and as directed.
11M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar (1:6)for laying floor finishescomplete all as specified and as directed.
12M&L for chequered cement concrete coloured tiles 30 cm x 30 cm x 25mm, set jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and as directed.
13M&L for cement concrete type B0 1:2:4 (using 12.50 mm graded stone aggregate) as in coping benching, gola, slightly rounded and similar items complete all as specified and as directed.
14M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggreate), 75 mm thick as in plinth protection including finishing the surface even & smooth without using extra cement complete all as specified and as directed.
15M&L for cement concrete type B-1 (1:2:4) with using 20mm graded stobe aggrgates) as insurface channels and drains complete all as specified and as directed.
16Dismanting of stone slab and tiles laid bedded and pointed in any mortar of any size description or thickness in floor, appron etc complete all as specified and as directed.
17M&L for 18-20 mm thick Granite tiles machine cut , bedded and jointed with grey cements slurry and pointed with white or colour cement with admixture of pigment to match the shade of granite stone including grinding & polishing slab over screed bed or bedding layer of mortar 15 mm thick in cement mortar (1 : 4)laid complete all as specified and as directed.
18M&L for 18-20 mm thick Granite tiles machine cut, in skirting/dado laid over cement mortar and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 10 mm thick rendering in cement mortar (1:4) on vertical surfaces for backing of tiles complete all as specified and as directed.
19Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified and as directed.
20M&L for brick work with sub class ‘B’ bricks old size straight or curved on plan exc 6.0 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
21M&L for brick work with sub class "B" brick, straight or curved on plan to any radiusin half brick works, built in CM 1:4 etc complete all as specified and as directed.
22Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys ,scrubbing down with water etc complete all as specified and as directed.
23M&L for 15 mm thick plastering in two layers (10+5) mm in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement), top layer shall be with WPC as per manufacturer"s instruction and complete all as specified and as directed. Note: WPC shall be measured and paid separately.
24Supply only intergral water proofing compound ISI Marked complete all as specified and as directed.
25M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior emulsion paint over a coat of primer complete all as specified and as directed.
26M&L for rendering 15 mm thick in cement mortar (1:6) onbrick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and as directed.
27M&L for preparation ofnewly plastered or unplastered/undecorated surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed.
28M&L for rendering 10mm thick in cement mortar1(1:3) as in ceilings finished even and smooth (without using extra cement) complete all as specified and as directed.
29M&L for preparation ofnewly plastered or unplastered/undecorated surface of Ceiling and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed.
30Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
31S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws complete all as specified and as directed.
32Dismantling mild steel work of any description not otherwise provided for complete all as specified and as directed.
33S&F rolled mild steel in framed work as in doors or steel gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing conforming to Fe- 290.Gde-E-165 complete all as specified and as directed.
34S&F framed work such as grills gratings, etc with ends of bar shouldered and/or revited or forged into spikes, framed guard bars, barred iron doors, ladders, framedbalusters, walk ways, railings framework of water tanka and similar works confirming to Fe 290 Gde E-165 complete all as specified and as directed.
35S & F Rolled Mild Steel Plates (plain or Chequered) channels, square cut or notched, forming holes, without any attachment confirming to Fe 410-S complete all as specified and as directed.
36S&F steel work as in tubular, rafters, purlins, posts and similar work(round/sqare/rectangular shape of pipes as approved by Engr-in-charge ) trusses of semi circle/ curved shape up to height 6 mtrincluding postspecial shaped washers etc complete incl necessary nut bolts wind ties and gusset plates etc using ERW or induction butt welded tubes conformining to IS 1161-1998 garde St-240 complete all as specified and as directed.
37M&L for preparation of new or previously untreated steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
38Dismantling ceiling board (fiber, pulp insulation) or insulation board/slabs etc including grid work/wooden or aluminium frame works, cover fillet etc complete all as specified and as directed.
39M & L for clip in type armed strong metallic powder coated 0.5mm thick ceiling with GI framework made of standard Tee , Angle or any other section as in grid type ceiling framework as approved by GE . Ceiling shall be hanged to roof trusses / purlin rafters with the help of GI wire not less than 4mm dia at an interval n. exc 1m , the size of the metallic powder coated ceiling tiles 600 mm x 600 mm complete all as specified and as directed.
40Taking downchowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and as directed.
41All as per item No.40 here-in-before butexc 1.5 Sqm and not exc 4 Sqm each complete all as specified and as directed.
42Taking down chowkhats or frames not exc. 1.5 sq. m each complete all as specified and as directed.
43All as per item No.42 here-in-before butexc 1.5 Sqm and not exc 4 Sqm each complete all as specified and as directed.
44Taking down shutter of any description exc 1 Sqmand n exc 2 Sqm and removing from site complete all as specified and as directed.
45Hacking out old broken glass (any thickness, size, quality or escription) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
46S&F factory made 35mm thickflush shutters , solid core construction with block board core and plywood face pannel commercial type on both faces complete all as specified and as directed.
47S&F factory made 35mm thick 2nd class hardwood glazed and skelton door shutters, open rebated and prepared to receive glass, gauze, (without sash bars) edges for framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-1 section 8 clause 8.24 (a) fitted to chowkats complete all as specified and as directed.
48S&F solidPVC door frame of size 50mm X47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing complete all as specified and as directed.
49S&F factory made PVC shelter panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheetfor top rail, lock railand bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement , supplying and fixing in the frame at site as per specification & drawing complete all as specified and as directed.
50S&F window or ventilators section of frame 72x55mm fixed to wall or concrete surface with rowl plugs made of galvanised steel powder coated and section of shutter 47x20mm mulion section 72x50mm (Based steel as per IS 513 "D" quality galanised as per IS 277 with zinc of 120 gms/sqm) glazed or gauged and wire gauge shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made of square bars powder coated fixed to window frame with screws including necessary fittings and all builders hardware such as handles, tower bolts and stays etc complete all as specified and as directed. (Note : Glass and wiremesh shall be measured and paid separately under respective items)
51S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified and as directed.
52S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified and as directed.
53M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
54S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified and as directed.
55S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
56S&F 150 mm size extruded aluminium alloy handles fabricatedtype anodised and fixed complete all as specified and as directed.
57S&F sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads complete all as specified and as directed.
58S&F forPressed steel frames 125X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed.
59S&F forPressed steel frames 105X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed.
60M&L for prepration of new Steel surfaces of any description, not otherwise descri-bed, over 10cm width or girth & applying two coats of synthetic enamel paintcomplete all as specified and as directed.
61Taking down of aluminium frame/doors/windows from site dismantling aluminium structure such as glass, rubber beading aluminium clips complete all as specified and as directed.
62S&F powder coated Anodised aluminium frame for partition, doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
63S&Fpowder coated anodized aluminum door shutters, aluminum section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door,100 mm longhinges (3 Nos), anodized aluminum snap beading screws etc. complete all as specified and as directed.
64S&F powder coated Anodised aluminium window and ventilator shutters, fixed/side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed.
65M&L for 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n. exc 0.5 sq. m in each panecomplete all as specified and as directed.
66M&L for 5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each panecomplete all as specified and as directed.
67S&F 9 mm thick prelaminated both side particle board exterior grade in bottom panel of Aluminium door including rubber gasket, aluminium glazing clips complete all as specified and as directed.
68S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and as directed.
69S&F in repair Mortice lock, vertical type of brass 100 mm 4 Levers with duplicate keys complete all as specified and as directed.
70S&F in repair aluminium (Die cast) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed.
71Dismantling boarding of any description , fixed in any position with nails complete all as specified and as directed.
72M&L for PVC 18 mm thickdecorative lamination board of density 600kg/cbm manufactured by an ISO:9001-2005 certifed with termite proof, water proof & flame retardant PVC Sheet. complete fixed with each other using solvent cementadhesive and stainless steel screws & including required handle, panels shall be fabricated using adhesive and screws and all the edges shall be covered with bonding tape and finished as per manufacturer instruction and all as specified.
73S&F Auto soft closed hinge for PVC laminated board complete all as specifed and as directed.
74S&F in repair 25 mm outer dia medium weight pipe made out of stainless steel 304 grade, includingdecorative ornamental knobs at both ends and one set of ornamental decorative Stainless steel clamps tofixed towalls complete all as specified and as directed.
75S&F in repair white vitreous China wash down water closet pan (pedestal pattern), and trap(excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. complete all as specified and as directed.
76S&Fas in repair vitreous china squatting pan, white, orissa pattern, size 580x440mm with integral foot rests (excluding flushing cistern & flush pipe) with cast iron ‘P’ trap incl lime concrete bedding and making good to the disturbed surface to match with the existing surface of floor complete all as specified and as directed.
77S&F in repairvitreous china pedestal pattern wash hand basin (flat back) white of size 550x400mmincluding one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector,including cutting for and pinning in ends of brackets complete all as specified and as directed.
78S&F in repair of plastic water closet sheet covers white closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
79S&F in repair fancy typeAngle stop cock with flange, 15 mm nominal bore, brass, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and as directed.
80S&F in repair angular two way angle cock with wall flange, 15 mm nominal bore cast copper alloy, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and as directed.
81S&F in repair pillar taps, cast copper alloy, with capstan heads, fancytype chromium plated, screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified and as directed.
82S&F in repair bib taps, long body,brass, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule orto GI socket complete all as specified and as directed.
83S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic actiontype with inlet ball valve and float, handle with & including bracket andPVC flush pipe 32 mm bore complete all as specified and as directed.
84S&F in repair PVC connection 450 mm long suitable for 15 mm GI pipe with two brass nuts & rubber washers complete all as specified and as directed.
85S&F as in repairPVC looking mirrorof selected quality of size 600 mm x450 mm on 4 mm thickwith framefixedscrew and cup- washers complete all as specified and as directed.
86S&F in repairtubular towel rail 20mm dia type brass chrormium plated 600mm long between flanges complete all as specified and as directed.
87S&F in repair chromium plated shower roses 125 mm size with or without swivel joints of standard size including fixing to 15mm steel pipe or union complete all as specified and as directed.
88S&Fin repair Corner glass shelf (with bracket) , fancy type with stainless steel railing fixed to wall with rawl plugs and chromium plated screws complete all as specified and as directed.
89S&F in repair brass CP mixer for mixing hot & cold water screwed down for iron pipe 15 mm dia and fixed complete all as specified and as directed.
90S&F chromium plated health faucet telephonic type with 8mm dia, 1 meter longCP flexible with wall hook and jet of approved make, suitable for 15 mm bore iron pipes or for unions and fixed complete all as specified and as directed.
91S&F in repair Soap dish ofchromium plated or stainless steel fixed to wall with chromium plated brass screws complete all as specified and as directed.
92S&F in repair Toilet paper holder with flat recessed type stainless steel complete all as specified and as directed.
93S&F in repair Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed.
94S&F in repair towel Rack 600 mm with hanger,brass,chromium plated,, fancy type fixed to wall with rawl plugs and chromium plated screws complete all as specified and as directed.
95S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed.
96S & F in repairs 900 x 800 x 260 mm plate rank of stainless steel with steel shelves make out of 0.7 mm thick steel sheet and hanging arrangement for utensil including taking down existing complete all as specified and as directed.
97S&F in repair PVC (SWR) floor trap plain with gratinghaving dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
98S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore complete all as specified and as directed.
99S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 110 mm bore complete all as specified and as directed.
100S&F in repair PVC (SWR) bends any radius 110mm bore complete all as specified and as directed.
101S&F in repair PVC (SWR) bends any radius 75mm bore complete all as specified and as directed.
102S&F in repair PVC (SWR) junction single, (single T) equal or unequal 75 mm bore complete all as specified and as directed.
103S&F in repair PVC (SWR) junction single, (single T) equal or unequal 110mm bore complete all as specified and as directed.
104S&F in repair 110mm dia PVC (SWR) pipe and single socketed in any length with rubber ring joint fixed to wall complete all as specified and as directed.
105Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 liters but not exceeding 500 litres complete all as specified and as directed.
106S&F for rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylinderical verticalwith closed top) hoisted and fixed in position all as per SSR Part I complete all as specified and as directed.
107Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 500 liters but not exceeding 1000 litres complete all as specified and as directed.
108S&F for rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylinderical verticalwith closed top) hoisted and fixed in position all as per SSR Part I complete all as specified and as directed.
109S&F in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm bore and fixed, minimum weight of float valve 210 gms complete all as specified and as directed.
110Taking up or down15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
111Taking up or down20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
112M&L for Cutting chases, pinning in. making good to facings where required andpointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girthin brick wall etc complete all as specified and as directed.
113S&F of CPVC pipes 16 mm outer diameter SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
114S&F of CPVC pipes 20 mm outer diameter SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
115S&F in repair 20mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
116Disconnecting existing PVC water tank of capacity exc. 250 ltr but not exc. 500 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified and as directed.
117Disconnecting existing PVC water tank of capacity exc.500 ltr but not exc. 1000 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified and as directed.
118Taking down carefully old copper/alluminium point, wiring (light, fan, socket or power) complete, including fitting such as switches, ceiling roses, pendants, regulator socket tube light fitting of any type, Bulk head fittingetc segregation serviceable fitting/fixture and keep them safe custody for reuse and removing materials from the site and making good disturbed surface of walls&floors etc as per existing specification complete all as directed.
119Taking down old unserviceable main switch, DB"s/RCBOs/MCCB/Sheet Metal Enclosures including MCBs & wooden/GI/MS sheet board etc and removing materials from the site of work complete all as directed.
120Taking down old unserviceable sub main wiring any size/core/type of copper/alluminium conductor.including making good the disturbed surfaces and removing materials from the site of work complete all as directed.
121M&L for point wiring complete with stranded copper conductor1.5 sqmm single core (nominal area ) PVC insulated and unsheathed cable 650 volts grade drawn in and including medium duty concealed in PVC concealed conduit conforming to IS andISI marked not less than 19 mm dia with 1.6mm thick concealed pressed steel terminal boxes with plate and framecover for rquired moduleincluding single core stranded copper conductor 1.5 sqmm PVC insulated unsheathed cable in same conduit as earth wire to the common earth and connecting to earth dolly all as specified for :-
122(a) One light point/bell point/one fan/exhanust fan controlled by one,one way switch.
123(b)For one 5 pin, socket outlet 5/6 amp on independent board with other switches
124(c)For one 3 pinsocket outlet 5/6 amp on sameboard
125(d)For one 3 pinsocket outlet 5/6 amp onbelowboard
126M&L for point wiring complete with stranded copper conductor 4 sqmm single core (nominal area ) PVC insulated and unsheathed cable 650 volts grade drawn in and including medium duty concealed in PVC concealed conduit conforming to IS andISI marked not less than 19 mm dia with 1.6mm thick concealed pressed steel terminal boxes with plate and framecover for rquired moduleincluding single core stranded copper conductor 2.5 sqmm PVC insulated unsheathed cable in same conduit as earth wire to the common earth and connecting to earth dolly all as specified for one 6 pin socket outlet two in one 16/6 amps on an independent board complete all as specified and as directed.
127S&F of switchmodular type single pole one way 6 amps complete all as specified and as directed.
128S&F of Bell push modular type 5 Amp complete all as specified and as directed.
129S&F of switch socket combination 2 in 1, 6 Amp modular Type 5 pin multipurposesuitable for independent board complete all as specified and as directed.
130S&F of socket outlet 2 in 1,3/5 pin6 Amp modulartype multipurposesuitable for same board complete all as specified and as directed.
131S&F of switch socket combination 2 in 1,5 pin multipurpose 16 A , modular type complete all as specified and as directed.
132M&L for submain wiring alongwith earth wire single coremulti stranded copper conductor FRLS unsheathed PVC insualted 1100 V grade cable drawn into and including PVC casing capping sleeves and caps of adequate width and lengthwith accessoris and fittings like bend, crosses wall crossing etc2x 4.0 sqmm1x 4.0 sqmm wirecomplete all as specified and as directed.
133M&L for submain wiring alongwith earth wire single coremulti stranded copper conductor FRLS unsheathed PVC insualted 1100 V grade cable drawn into and including PVC casing capping sleeves and caps of adequate width and lengthwith accessoris and fittings like bend, crosses wall crossing etc2x 6.0 sqmm1x 6.0 sqmm wirecomplete all as specified and as directed.
134M&L for submain wiring alongwith earth wire single coremulti stranded copper conductor FRLS unsheathed PVC insualted 1100 V grade cable drawn into and including PVC casing capping sleeves and caps of adequate width and lengthwith accessoris and fittings like bend, crosses wall crossing etc2x 10.0 sqmm1x10.0 sqmm wire complete all as specified and as directed.
135S&F in replacement of tube light fitting 1X20 w,LED Batten wall mountedwith alumunium housingand integrated electronic driver . Make havells cat part no LUMLINEPLUSBS20WLED865SPCSS or equuivalent out of makes specified in list of makes.
136S&F in replacement of tube light fitting 1X10 w,LED Batten wall mountedwith alumunium housingand integrated electronic driver . Make havells cat part no LUMLINEPLUSBS10WLED865SPCSSor equuivalent out of makes specified in list of makes.
137S&F sheet metal enclosures for DB-4 way, SPN, 200 Amps Bus bar 240 Voltssingle door complete all as specified and as directed.
138S&F sheet metal enclosures for DB-08 way, SPN, 200 Amps Bus bar 240 VoltsSingle door complete all as specified and as directed.
139S&F sheet metal enclosures for DB-12 way, SPN, 200 Amps Bus bar 240 VoltsSingle door complete all as specified and as directed.
140S&F MCB SP 240 volt, 5 to 32 Amps, C series, 10 KA complete all as specified and as directed.
141S&F MCB SPN 240 volt, 5 to 32 Amps, C series, 10 KA complete all as specified and as directed.
142S&F electronic type modular , 120 watt -2 modul fanregulator complete all as specified and as directed.
143S&F ceiling rose , singlephase /PVC /Polycarboante isolated body complete all as specified and as directed.
144S&F Bell Multi Music typeAC, 230 volts complete all as specified and as directed.
145M&L for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less thatn 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers GI earth wire with protected by 15mm dia light grade GI pipe and other end connected to earth testing point or main controlling switch as directed incl funnel with watering pipe 20mm bore light grade GI pipe, wire mess , charcol and common salt, concrete earth pit in PCC (1:3:6) type C1 cast iron frame cover , including necessary excavation, earth work in soft/loose soil and disposal of soil to a distance not exc 50mtr and necessary testing complete all as shown in electrical plate No 3 of MES schedule Part I and testing all as directed.
146S&F Higly efficient LED Bullbs of 15 W complete all as specified and as directed.
147M&L in relacementfor Decorative garden/gate light , LEXO PRISMATIC ,made up of high grade unbreakable polycarbonate material suitable for upto 20 wLED lampn(b22) complete all as specified and as directed. Make: Havells cat part no LHFOGAE1T11F015 , retrofit LED suitale to fitted on pipe upto 60mm dia or equivalent out of makes specified in list of makes.
148M&L for Servicing of DG sets of capacity 20 KVA TO 320 KVA including minor repair and replacement of the following items :-(i) S & F in repair lubrication oil filter (ii) S & F in repair by pass filter(iii) Checking of hydraulic governer (iv) Checking and toping up of coolant(v) S & F in repair fuel filter.(vi)S & F in repair air cleaner element . (vii)Cleaning radiator complete set (viii)Engine Oil as per manufacturer specification and any other checking as per manufacturer instruction
149S&F in replacement of AVR S/F VARIABLE SPEED DCDGsuitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage 6 Amp 95 Volt DC suitable for DG set upto 31.25 KVA complete all as specified and as directed.
150Supply & fixingfollowing items in replacement of DG Set of various capacity :-
151i). Battery terminal, lug, bolts type suitable for heavy duty battery.
152ii) Battery leads for copper conductor multiwired 16Sqmm. 1.5 mtrs long
153iii) Hinges for DG set door of any size, any type as required on site.
154Dismantling/Taking out of radiator assembly to work shop for cleaning with compressed air ,pointing out leaking places and soldering carefully and refix in position after making it serviceableof DG 25/30 KVA complete all as specified and as directed.
155Dismantling of self starter, opening and segregating cleaning the serviceable parts for re-use, self starter servicing and greasing, re-assembling the self starter complete all as specified and as directed and replacement of following parts :- (i) Carbon bush(ii) Brass plunger (iii) Solenoid switch(iv)) Funnel coil (v) Body brass nut
156S&F V belt for fan pulley (set of 2Nos) for DG set upto 25 KVA DG Set complete all as specified and as directed.
157S&F V belt for alternator and water pump assembly for DG set upto 31.25 KVA complete all as specified and as directed.
158S&F Fuel hose pipe from fuel filter to fuel pump for DG set upto 31.25 KVA, complete all as specified and as directed.
159S&F Fuel pipe from fuel tank to fuel filter (transparent) for DG set upto 31.25 KVA, complete all as specified and as directed.
160S&F fuel feed pump suitable size as required on site for DG set of capacity upto 31.25 KVA, complete all as specified and as directed.
161S&F Fuse (HRC type) 63 amps, for DG sets of capacity 31.25 KVAcomplete all as specified and as directed.
162S&F maintenance free battery 12 volts60 AH , ISI mark, with 24 months replacement waranttee complete all as specified and as directed.
163Taking down and dismantling HPSV/ LED type street light fittingfor45/ 70/150/250 watt capacity of any make/type from pole/GI pipe unserviceable items to be kept in safe custody and taken as credit complete all as specified and as directed.
164S&F LED street light luminaire IP-66 grade of proterction with 24 High power LED of 70/72 watt rating and extendable upto 48 watt ratingwith unique peanut lens to ensure uniform distributioncomplete all as specified and as directed.
165M&L for defect rectification LTcable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. including and additional excavation in normal alluvial strata required for exposing the cable fault, removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of any size complete all as specified and as directed.The fault locating equipments shall be brought to site within the hours of instruction from Engr-in-Charge.
166Supply andjointing straight through joint suitable for LT 415 Volt XLPE cable of size 70 to 120 Sq mm 3.5 corecomplete all as specified and as directed.
167Supply andjointing straight through joint suitable for LT 415 Volt XLPE cable of size 25 to 50 Sq mm 3.5/4corecomplete all as specified and as directed.
168S & Fin replacement of Aluminium Cable lugs/Thimbles upto size 16 to 25 sqmm complete all as specified and as directed.
169S & Fin replacement of Aluminium Cable lugs/Thimbles of size 35 to 50 sqmm complete all as specified and as directed.
170S & Fin replacement of Aluminium Cable lugs/Thimbles of size 70 to 120 sqmm complete all as specified and as directed.
171M&L for Foundation & Complete Pole for Tubular swaged pole typePoleincluding excavation , getting out, pole foundation with PCC type D2 1:4:8 (with 40 mm graded aggregate). Coping of pole with PCC type C1 1:3:6 ( with 20 mm graded agregate)and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and as directed.
172M&L for painting of steel tubular pole including cable protection pipe and all iron parts of 9/11 mtr long pole complete with 2 coats of aluminium paint after cleaning all rust and dust and preparing surface with wire brush and including strips of white and bluecolour of synthetic enamel paint up to the height of 1.5 mtr from the bottm of the pole complete all as specified and as directed.
173S&F in replacement ofautomatic timer switch pole mounted enclosure consisting of ON/OFF switch based on LUX level power contactor 40 Amps, 10KA "C" series 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as specified and as directed. Note: (i)Inlet/outlet connecting cable PVC insulated aluminium stranded conductor 6 Sqmm, 4 single core for incoming & outgoing up to 8 Mtr deemed to be included in the unit rate. (ii) Provn of glands and lugs shall be deemed to be included in the quoted rate.
174Supply, laying and testing in replacementcable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 25 sqmm x 4 corecomplete all as specified and as directed. Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
175Supply, laying and testing in replacementcable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 95 sqmm x 3.5 corecomplete all as specified and as directed. Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
176Supply, laying and testing in replacementcable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 50 sqmm x 3.5 corecomplete all as specified and as directed. Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
177Excavation in trenches not exceeding 1.5m wide and not exceeding 1.50m deep for laying of water pipe lines/taking out pipe lines and getting out in soft/lose soil including forming bottom surface to required level and slope all as specified and as directed.
178Returing ,fiiling including spreading ,leveling ,watering and well ramming in layers not exe. 25 cm soil all as specified and as directed.
179Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the strarting point complete all as specified and as directed.
180Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted. Note : Punned down thickness shall be measured and paid .
181Supplying and laying reinforced precast concrete cable cover complete all as specified and as directed.
182M&L for Servicing of Airconditioning unit of 4.6 TR cap. ,cleaning with service chemical& air pressure the whole package unit inside,cooling coils ,indoor and outdoor units complete all as specified and as directed.
183M&L for Testing of pipe line for any type of leakageusing nitrogen gas at pressure of 20 kgs/ sqcm and 10Kgs /sqcm on low side and holding it for 24 hours and detecting the leakages and brazing the leakingpoints to stop leakages completely, complete all as specified and as directed.
184M&L for Making the piping system vacuum and supply and charging the refrigerant gas R -410 a of required quantity as recommended by manufacturer to get sufficient cooling complete all as specified and as directed.
185M&L for Dismentling and taking out old burnt damaged coils of ceiling fan 1200/1400 mm sweep including scraping out old paint & cleaning all dust, making smooth surface with filler materials/ sand paper & painting with 1st grade quality synthetic enamel paint by spray & proper numbering including replacing of Twin flexible wire with new from ceiling rose to connector of fan complete all as specified and as directed.
186M&L for Rewinding of ceiling fan 1200/1400 mm sweep with the same guage as per existing by new supper enameled copper wire includinginsulating material, heating, varnishing, reassembling, testing complete all as specified and as directed.
187S&F of following partsin replacement of unserviceable parts :-
188I)   Ball bearings ISI mark
189II)  Condenser 2.50 mfd
190III)  Split pin
191IV)  Fan blades
192V)   Down rod
193M&L for Servicing, Oiling, Greasing and Cleaning of window type/ split type AC with high pressure pump of any capacity, checking of defects/ leaking and adjusting setting to work and testingand writing of MES no .complete all as specified and as directed.
194M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 1.5 ton Split/W/T type AC complete all as specified and as directed.
195M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 2 ton Split/W/T type AC complete all as specified and as directed.
196S&F in Replacement of burnt out transformer and S&F newtransformer of 5 KVA voltage stabilizercomplete all as specified and as directed.
197S&F in replacement running capacitor of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
198S&F in replacement of starting relay of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
199S&F in replacement starting capacitor of existing make and capacity duly ISI marked for window type A/C 1.5 ton and split type AC 1/1.5/2 ton capacity complete all as specified and as directed.
200S&F in replacement of Electronic control (PCB)of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
201Repairto compressor off size of existing makes and capacityfor W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
202S&F in replacement Filter pad of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
203S&F in replacement of Thermostat switch of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
204S&F in replacement of of remote complete all as specified and as directed.
205M&L for Rewinding of blower motor ofcapacity 1.5/2.0 Ton complete all as specified & as directed.
206S&F in replacement of new rotary type AC compressor of window type/splitAC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 1.5Ton capacity complete all as specified & as directed.
207S&F in replacement of new reciprocatingtype, AC compressor of window type/splitAC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 2.0 Ton capacity complete all as specified & as directed.
208S&F in replacement of Evaporator coil complete all as specified and as directed.
209S&F in replacement of Suction/Discharge valve complete all as specified and as directed.
210S&F in replacement of Copper tube for 1.5 /2.0 Ton split AC 1/4 complete all as specified and as directed.
211S&F in replacement of Copper tube for 1.5 /2.00 Ton split AC 1/2 complete all as specified and as directed.
212S&F in replacement of Copper tube cover complete all as specified and as directed.
213S&F in replacement of insulation pipe size ¾” or 1” dia for split AC 1.5 / 2 Ton complete all as specified and as directed.
214S& F in replacement of outer unit incl compressor suitable for 1.5 tonsplit ACcomplete set incl testingmake Logicool complete all as specified and as directed.
215S& F in replacement of inner unitsuitable for 1.5 tonsplit ACcomplete set incl testingmake Logicool complete all as specified and as directed.
216M& L for detection/ rectification of leakageof gas in the system and gas charging in the system with appropriate qty of gas incl uding testing for smooth functioning of water of capacity 60/80/120 ltrs complete all as specified and as direted . Note :-(i) Unserviceablecondensing coil if reqd shall be measured and paid for separately .(ii) Cost of dismantling of unserviceable compressor if reqddeemed to be included in unit rate . (iii)compressor shall be measured and paid separately under respective items of sch "A".(iv) Refilling & topping up refrigent (type & quantity as required on site is measured & paid separetely)
217S&F in replacement of compressor reciprocatint type (hermitecally) sealed for capacity 40/80 Ltrs water cooler complete all as specified and as directed.
218S&F inrepair of thermostat switch suitble for existing watre cooler anymake and capacitycomplete all as specified and as directed.
219S&F in replacement of Starting relay andoverload relay suitable for existing size & make water cooler completeall as specified and as directed.
220S&Fin replacement of Starting capacitor for water cooler suitable for existing size& make water cooler completeall as specified and as directed.
221S&F in replacement ofrunningcapacitor suitable forexisting size & make water cooler completeall as specified and as directed.
222M&L for dismantling of old defective condenser , fan motor of water coolerof any make and capacity and refixing and testing the same after rewindingwith super enamelled copper wire complete all as specified and as directed.
223M&L servcing of Deep freezer any capacity and size by cleaning greasing including painting with one coat of super synthetic enameled paintincluding prepartion of surfaces completeall as specified and as directed.
224M&L of Gas Charging in deep freezer any makeand capacity including testingof leakage complete all asspecified and as directed.
225Supply laying, testingGI tubing80mmbore medium grade conforming to IS : 1239with all fittings laid in trenchescomplete all as specified and as directed.
226Supply laying, testing 3- LAYER PP-R(Polypropelene random copolymer ) pipes SDR-11,PN 10UV stabilised and antimicrobial welded having thermal stability for hot & cold water supply including all PP- R Plain & brass threadedpolypropelene random fitting fixed complete to walls , ceiling or in trenchsize 50mm all as specified & as directed.
227Supply laying, testingGI tubing25 mm bore medium grade conforming to IS : 1239with all fittings laid in trenchescomplete all as specified and as directed.
228Supply laying, testingGI tubing20 mmbore medium grade conforming to IS : 1239with all fittings laid in trenchescomplete all as specified and as directed.
229Taking up cast iron water mains 100/150mm bore (including all fitting ),with spigot and socket ends/flanged ends /rubber gasket joint including disconnecting complete all as specified and as directed.
230Supplying, laying and testing Cast iron pipe100mm bore with spigot and socketed end ,class LA ,in any length laid in trenches /on pedestals complete all as specified and as directed.
231Supplying, laying and testing Cast iron pipe150mm bore with spigot and socketed end ,class LA ,in any length laid in trenches /on pedestals complete all as specified and as directed.
232Drilling and tapping cast iron water mains for branch connection of the internal dia 20mm including clamp piece and nuts and bolts and as directed.
233M&L run lead joints for following sizes of CI spun pipes /fittings complete all as specified and as directed for :-
234i)100mm pipe
235ii)150mm pipe
236Taking down of existing GI tubing 40/50/80mm bore any type complete all as specified and as directed.
237Taking down of exixting GI tubing 25mm bore any type complete all as specified and as directed.
238Taking down of exixting GI tubing 20mm bore any type complete all as specified and as directed.
239Manpower and machinery for Lifting of submersible pump set any description from borewell including column pipe and submersible cable and lowering ofpump in bore well after development of borewellincluding replacement of coloumn pipes all as directed. Note: cost of disconnecting pipe from header / cables from panel shall be deemed to be included in the quoted rate.
240M&L for repairs & Servicing ofdefective submersible pump of capacity up to10 HP by dismantling the pump & removing unserviceable parts , assemble the pump properly after replacementsof unserviceable partscomplete all as specified and as directed .Note:- (a) The rates are inclusive of transporting the pump from bore well siteto repair work shop & back to site. (b) The rate are inclusive ofturning / finishing work for fixing of parts properly. (c)   The replacement of unserviceable parts will be measuredand paid separately under respective item of this schedule.
241M&L for rewinding of Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter, Capacity of motor 10 HP complete all as specified and as directed.
242S&F parts of submersible pump set of capacity 10 HP complete all as specified and as directed :-
243i) Bearing bush Gun Metal
244ii) Bearing bush SS with rubber
245iii)Oil seal
246iv)Thrust plate/thrust bearing set
247v)Sand Guard
248vi)CI Thrust Casing
249vii) CI stage casing
250viii).GM Bush
251ix)Mild steel key for impeller
252x)SS Studs with nuts
253xi)CI Intermediate section
254xii)SS coupling bush common for pump & motor with key
255xiii) High Tensile steel shaft
256Taking the water sample for semi under ground sump and submitted the sample of water to the Govt lab for testing of water ,Chlorine test and all chemical componants test complete all as specified and as directed.
257M&Lin replacement of flat submersible 3 core 6 sqmm cable PVC insulated unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
258M& L for servicing ofRO plant( Acqua gurad type) of capacity15 to40 trs per hour incl replacement of following items:-
259i)Carbon filter
260ii)Sediment filter
261iii) Membrane
262iv) R O Pump
263S&Fin replacingof dosing pumpincl. Replacing of PVC pipe of existing size and make complete all as specified and as directed.
264M& Lfor taking out pump motor set vertical cap 10HP,dismantling pump and motor separately , rewinding of electric motor with super enamelled copper wire of existing gauge after cleaning the slotsproperly and assemblingand refixing in position and testing complete all as specified and as directed.
265Cleaning of RCC underground sumpof Size10X10X10CFTcomplete by removing all scales, dirts, mud, chemical deposit etc from innerand outerchamber of tank as well as from the mouth of all circulating pipes connected with sump including scrapping out and throughly cleaning of internal surface/floor by using bleaching powder, soda ash etc complete all as specified and as directed.
266M&L for Dismantling/Braking old unserciceable /dilapidated valve pit and Construction ofnew brick masionary valve pit of size1.2 X1.20 X 0.9 mtr with brick work 15 mm thick internal and external plaster in cm 1:4 inlcluding 25 X 25 X 5 mm MSangle iron frame all around the fixed point by means of 04 Nos hold fast 150 mm long made out of flat iron, 25 X 6 mm embedded in PCC block 1 : 2 : 4 type B1 including hinges welded with angle iron frame and MS cover 3 mm thick , MS handle of suitable locking arrangements and applaying two coat of synthetic enamal paint over a coat of red oxide primer including necessary excavation, removing/returning filling in soft/loose soil complete all as specified and as directed.
267Cleaning of RCCunder ground sumpof 50000 Gallon capacity complete by removing all scales, dirts, mud, chemical deposit etc from insidethetank as well as from the mouth of all circulating pipes connected with RCC tank including scrapping out and throughly cleaning of internal surface/floor by using bleaching powder, soda ash etc complete all as dircted &specified by Engr-in-Charge. Note Proper care should be taken during cleaning so that no scales/dirts/deposits enters the supply/delivery line complete all as specified and as directed.
268Cleaning of RCC over head reservoir of 50000 Gallon capacity complete by removing all scales, dirts, mud, chemical deposit etc from inner& outerchamber of tank as well as from the mouth of all circulating pipes connected with RCC tank including scrapping out and throughly cleaning of internal surface/floor by using bleaching powder, soda ash etc complete all as dircted of specified by Engr-in-Charge. Note Proper care should be taken during cleaning so that no scales/dirts/deposits enters the supply/delivery line complete all as specified and as directed.
269Attending Complaints by deploying sufficeient labour for rectification of leakage of UG water pipe lines of size 80 to 100 mm Bore of any description such as CI/GIpipe line at any location including necessary excavation, earth work, dewatering, cutting existing pipe lines including repairs with suitable flanges, Joints or any other material complete all as specified and as directed.
270Attending Complaints by deploying sufficeient labour for rectification of leakage of UG water pipe lines of size 80 to 50 mm Bore of any description such as CI/GIpipe line at any location including necessary excavation, earth work, dewatering, cutting existing pipe lines including repairs with suitable flanges, Joints or any other material complete all as specified and as directed. Note: (i)Complaint shall be notified to contractor on mobile phone.Hence,it is mandatory to mention his mobile No. while quoting the tender. ii)Complaint shall be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and will be rectified within 12 hours after notification, failing which double of quoted rate per day per complaint will be recovered. iii) Completion report of the complaint shall be given in writing and recorded in the register. iv) Rates quoted shall be deemed to include the cost of T&P required. Pipes and Jointing material shall be measured and paid under relevant items of schedule
271Attending leakage complaints of sluice valves by opening removing gland plate and pumping/taking water from water pit and proving gland packing and refitting by replacing worn out bolts,nuts and washers complete all as specified. Note: bolts,nuts and washers will be paid under relevant items of schedule complete all as specified and as directed.