Tender For Creation Of 63Kva Sub-Station At Bajwani, awantipora-Jammu And Kashmir

Power Development Department has published Tender For Creation Of 63Kva Sub-Station At Bajwani. Submission Date for this Tender is 13-01-2024. Overhead Line Tenders in awantipora Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

41518919
Corrigendum : Tender For Creation Of 63Kva Sub-Station At Bajwani
Open Tender
Indian
Jammu And Kashmir
awantipora
13-01-2024

Tender Details

Tender For Creation Of 63Kva Sub-Station At Bajwani- 1 Installation, Testing, Commissioning Including Loading, Transportation, Insurance, Unloading, Carriage And Delivery At Siteof 25Kva, 11 / 0.433 Kv Distribution Transformer, ( Transformer Deptt.Supply ) 2 Errection, Testing & Commissioning Including Loading, Transportation, Insurance, Unloading, Carriage And Delivery At Siteof 9 Mtr Long St Poles Sp-33 Including Excavation Of Pole Pits, Refilling The Pit With Soil, Boulders. ( Deptt. Supply ) 3 Errection, Testing & Commissioning Including Loading, Transportation, Insurance, Unloading, Carriage And Delivery At Siteof 8 Mtr Long St Poles Sp-15 Including Excavation Of Pole Pits, Refilling The Pit With Soil, Boulders. ( Deptt. Supply ) 4 Supply, Laying, Testing, Stringing, Tensioning And Binding Of Conductor Acsr 0.05 ( Rabibit ) Including Pre-Tensioning For Removal Of Kinks, Fixing Of Hardware Fittings And Jointing As Per Standard Practices And Mechanical / Manual Carriage Upto Site. 5 Providing & Fixing Of Earthing Complete By Gi Pipe 40 Mm 3 Mtr Long Through Gi Strip 25X3 Mm. As Per Rec Standards / Drawings. 6 Supply And Painting Of Each Pole 1 Coat Red Oxide Paint And 2 Coats Of Aluminium Paint ( @ 1 Ltr / Pole Red Oxide Paint And 1 Ltr / Pole Aluminium Paint ) Inscribed With Permenent Marking On Each Pole Viz. Name Of Scheme - 2021-22 / Xx - Xxmeans Pole Numbers Say 01, 02..... 7 Providing, Errection, Testing & Commissioning Of G.Ichannel Cross Arms, G.I V-Cross Arms, Sub-Station Channels ( G.I ) & Angle Iron Braces ( G.I ) , Transformer Beltings, Including Back Clamps For Fixing Cross Arms Etcfabricated Of Different Sizes ( Rec Standard ) & To Be Fixed With Gi Nuts & Bolts And Washers Without Drilling / Punching Holes In The Poles. 8 Providing & And Fixing Of 11 Kv Pin Insulators ( Polymer ) With Pins ( 5 Kn ) 9 Providing & Fixing Of 11 Kv, G.O Ab Switch , 3-Phase, 200A ( 09 Insulator Post Type ) With Arragement For Pad Locks & Operating Rod . The Operating Rod Shouldbe G.I Pipe ( B-Class ) Of 25 Mm Dia Of Requisite Length. 10 Providing & Fixing Of 11 Kv Horn, Gap Fuse 3-Phase 100A 11 Providing & Fixing Supply And Installation Of Gapless Surge Arrestor, 9 Kv, 10 Ka, La With ( Polymer ) Housing, Station Type 12 Providing And Fixing Of Lt Fuse Set Complete By Using Angle Iron Of Size 45X 40 X 3Mm------ 6Ft. Long ( Cement Grounting } - 2 Numbers With Insulators Etc. 13 Providing & Fixing Of Single Core Aluminum ( Al. ) Lt Power Cable ( 1.1 Kv Grade ) 185 Mm Sq Cross Section Un-Armoured Xlpe Cable With Thermoplastic Tape Inner Sheath From The Lt Bushes Upto The Overhead Lt Bare Conductor. 14 Providing, Laying Of Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5 Cum / Pole Including Muffing 20 Cm Above Groundlevel, Plaster And Curing Of Concrete. 15 Providing, Laying Of Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.45Cum / Pole Including Muffing 20 Cm Above Groundlevel, Plaster And Curing Of Concrete. 16 Providing & Fixing Of P.G. Clamps For Fixing Of Lt Cable With Distribution Transformers Having Capacity Upto 100 Kva 17 Providing & Fixing Of185 Mm Sq Aluminum Thimbles For Cable Terminations 18 Providing And And Fixing Of 3 No. Sub Station Earthingby Gi Pipe 40 Mm Or Gi Rod 20Mm, 2.5 Mtr Long Through Gi Strip Of 50X6 For Neutral Earthing And 25X3 Mm For 2 Transformer Body Earth, Two No. Pole Earth, 1 No. La Earth And 1 No. Go Handle Earth As Per Rec Approved Construction Standards With F5, F10 & J2 Drawings Issued By Rec As Reference. Each Electrode To Be Connected Through Double Gi Strips To Be Fixed On Baby Insulators. The Termination Should Be Bolted And Not Welded. 19 Providing And Fixing Of Shackle Insulators ( Polymer ) ( 16Kn ) With Gi Back Clamps To Be Fixed Without Drilling / Punching Of Poles On St Poles.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Jan-2024 CORRIGENDUM NOTICE Technical Bid 13-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 2000.0 /-
Tender Value
INR 1.50 Lakhs /-

BOQ Items

Name of Work:-Creation of 25KVA Sub-Station at Bajwani.
Sl. No. Item Description
1Installation,testing,commissioningincluding Loading, Transportation, insurance, Unloading, Carriage and Delivery at Siteof 25KVA, 11/0.433 kV Distribution Transformer,(Transformer Deptt.Supply)
2Errection,testing & commissioning including loading, transportation, insurance, unloading, carriage and delivery at siteof 9 Mtr long ST Poles SP-33 including excavation of pole pits, refilling the pit with soil, boulders.(Deptt. Supply)
3Errection,testing & commissioning including loading, transportation, insurance, unloading, carriage and delivery at siteof 8 Mtr long ST Poles SP-15 including excavation of pole pits, refilling the pit with soil, boulders.(Deptt. Supply)
4Supply, Laying,testing, stringing, tensioning and binding of conductor ACSR 0.05 (Rabibit) including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices and mechanical/manual carriage upto site.
5Providing & fixing of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm. as per REC Standards/drawings.
6Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) inscribed with permenent marking on each pole viz. name of scheme - 2021-22/xx - xxmeans pole numbers say 01,02.....
7Providing, errection, testing & commissioning of G.Ichannel cross arms, G.I V-Cross arms, Sub-station channels (G.I) & Angle Iron Braces (G.I), transformer beltings, including back clamps for fixing cross arms etcfabricated of different sizes (REC Standard) & to be fixed with GI Nuts & Bolts and washers without drilling/punching holes in the poles.
8Providing & and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN)
9Providing & fixing of 11 kV,G.O AB Switch , 3-phase, 200A (09 insulator post type) with arragement for pad locks & operating rod . The operating rod shouldbe G.I Pipe (B-class) of 25 mm dia of requisite length.
10Providing & fixing of 11 kV Horn,Gap Fuse 3-phase 100A
11Providing & fixing Supply and installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type
12providing and fixing of LT fuse set complete by using Angle iron of size 45x 40 x 3mm------ 6ft. Long ( cement grounting} - 2 numbers with insulators etc.
13Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 185 mm sq cross section un-armoured XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor.
14Providing, laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole including muffing 20 cm above groundlevel, plaster and curing of concrete.
15Providing, laying of Cement bottoming 1:2:4 mix as per REC standards 0.45cum/pole including muffing 20 cm above groundlevel, plaster and curing of concrete.
16Providing & fixing of P.G. clamps for fixing of LT cable with distribution transformers having capacity upto 100 kVA
17Providing & fixing of185 mm sq Aluminum Thimbles for cable terminations
18Providing and and fixing of 3 No. sub station earthingby GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 for neutral earthing and 25X3 mm for 2 transformer body earth, two no. pole earth, 1 no. LA Earth and 1 no. GO handle earth as per REC approved construction standards with F5, F10 & J2 drawings issued by REC as reference. Each electrode to be connected through double GI strips to be fixed on baby insulators. The termination should be bolted and not welded.
19Providing and fixing of shackle insulators(polymer) ( 16KN) with GI back clamps to be fixed without drilling/punching of poles on ST poles.