Power Development Department has published Survey,Supply, Transportation, Carriage, Erection,Testing And Commissioning For Creation Of8x100 Kva & 3X63 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Pinger Under. Submission Date for this Tender is 06-02-2024. Electrification Work Tenders in Udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 30-Jan-2024 | Date Extension Notice I | Date | 06-02-2024 |
Sl. No. | Item Description |
1 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSS Pinger (Stage Zero). |
2 | 9 mtr. Long ST Pole (ST-410 SP-33) |
3 | GI V Cross -arm with top Bracket including clamps |
4 | GI Channel X-arm including clamps and Angle for braces |
5 | 30mm² ACSR Weasel Conductor |
6 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
7 | PG Clamps |
8 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
9 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
10 | Galvanized Nuts and Bolts |
11 | Danger Plates with Clamps |
12 | Anti climbing device with clamps |
13 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
14 | Painting of 9 mtr ST poles with two coats of Aluminiumpaint. |
15 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
16 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
17 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Installation of 2x100 KVA Substation at WSS Pinger (Stage-Zero) |
18 | 11/0.433 KV, 3-phase distribution Transformer 100 KVA with Bimetallic Terminal Connectors Energy Level-2 AluminiumWound, & with LV Cable box having detachable Aluminium Gland plate |
19 | Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
20 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
21 | 11 KV Horn gap fuse set 3 phase 200 A |
22 | 185mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
23 | 9 mtr. Long ST pole (ST-410 SP-33) |
24 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75Positive and 80 KV Negative, creepage distance 320mm with fitting |
25 | GI Channel /Angle/flat of sizes including clamps |
26 | Galvanized Nuts and Bolts. |
27 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
28 | 11 KV Poloymer composite pin insulator, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm |
29 | LT distribution box for 100 KVA DTR with MCCB for incomer and SFU"s for outgoing circuits |
30 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
31 | PG Clamps |
32 | Danger Plates with Clamps |
33 | GI Barbed wire for Anticlimbing |
34 | 3-phase 4-wire Prodigy meter with box |
35 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
36 | Painting of ST poles 9 mtr. Long with 2 coat of Al. paint |
37 | Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS Pinger (Stage Zero). |
38 | 8 mtr. Long ST poles (ST-410 SP15) |
39 | GI M Clamps for shackle insulator |
40 | 30mm²ACSR Weasel Conductor |
41 | Shackle insulator |
42 | Galvanized Nuts and Bolts. |
43 | Danger Plates with Clamps |
44 | Anti climbing device with clamps |
45 | Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip |
46 | Painting of 8 mtr ST poles with two coat of Aluminium Paint |
47 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
48 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSS Pinger (Stage First). |
49 | 9 mtr. Long ST Pole (ST-410 SP-33) |
50 | GI V Cross -arm with top Bracket including clamps |
51 | GI Channel X-arm including clamps and Angle for braces |
52 | 30mm² ACSR Weasel Conductor |
53 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
54 | PG Clamps |
55 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
56 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
57 | Galvanized Nuts and Bolts |
58 | Danger Plates with Clamps |
59 | Anti climbing device with clamps |
60 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
61 | Painting of 9 mtr ST poles with two coats of Aluminiumpaint. |
62 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
63 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
64 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Installation of 100 KVA Substation at WSS Pinger (Stage-First) |
65 | 11/0.433 KV, 3-phase distribution Transformer 100 KVA with Bimetallic Terminal Connectors Energy Level-2 AluminiumWound, & with LV Cable box having detachable Aluminium Gland plate |
66 | Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
67 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
68 | 11 KV Horn gap fuse set 3 phase 200 A |
69 | 185mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
70 | 9 mtr. Long ST pole (ST-410 SP-33) |
71 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75Positive and 80 KV Negative, creepage distance 320mm with fitting |
72 | GI Channel /Angle/flat of sizes including clamps |
73 | Galvanized Nuts and Bolts. |
74 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
75 | 11 KV Poloymer composite pin insulator, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm |
76 | LT distribution box for 100 KVA DTR with MCCB for incomer and SFU"s for outgoing circuits |
77 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
78 | PG Clamps |
79 | Danger Plates with Clamps |
80 | GI Barbed wire for Anticlimbing |
81 | 3-phase 4-wire Prodigy meter with box |
82 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
83 | Painting of ST poles 9 mtr. Long with 2 coat of Al. paint |
84 | Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS Pinger (Stage First). |
85 | 8 mtr. Long ST poles (ST-410 SP15) |
86 | GI M Clamps for shackle insulator |
87 | 30mm²ACSR Weasel Conductor |
88 | Shackle insulator |
89 | Galvanized Nuts and Bolts. |
90 | Danger Plates with Clamps |
91 | Anti climbing device with clamps |
92 | Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip |
93 | Painting of 8 mtr ST poles with two coat of Aluminium Paint |
94 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
95 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSS Pinger (Stage Second). |
96 | 9 mtr. Long ST Pole (ST-410 SP-33) |
97 | GI V Cross -arm with top Bracket including clamps |
98 | GI Channel X-arm including clamps and Angle for braces |
99 | 30mm² ACSR Weasel Conductor |
100 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
101 | PG Clamps |
102 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
103 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
104 | Galvanized Nuts and Bolts |
105 | Danger Plates with Clamps |
106 | Anti climbing device with clamps |
107 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
108 | Painting of 9 mtr ST poles with two coats of Aluminiumpaint. |
109 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
110 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
111 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Installation of 100 KVA Substation at WSS Pinger (Stage-Second) |
112 | 11/0.433 KV, 3-phase distribution Transformer 100 KVA with Bimetallic Terminal Connectors Energy Level-2 AluminiumWound, & with LV Cable box having detachable Aluminium Gland plate |
113 | Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
114 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
115 | 11 KV Horn gap fuse set 3 phase 200 A |
116 | 185mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
117 | 9 mtr. Long ST pole (ST-410 SP-33) |
118 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75Positive and 80 KV Negative, creepage distance 320mm with fitting |
119 | GI Channel /Angle/flat of sizes including clamps |
120 | Galvanized Nuts and Bolts. |
121 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
122 | 11 KV Poloymer composite pin insulator, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm |
123 | LT distribution box for 100 KVA DTR with MCCB for incomer and SFU"s for outgoing circuits |
124 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
125 | PG Clamps |
126 | Danger Plates with Clamps |
127 | GI Barbed wire for Anticlimbing |
128 | 3-phase 4-wire Prodigy meter with box |
129 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
130 | Painting of ST poles 9 mtr. Long with 2 coat of Al. paint |
131 | Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS Pinger (Stage Second). |
132 | 8 mtr. Long ST poles (ST-410 SP15) |
133 | GI M Clamps for shackle insulator |
134 | 30mm²ACSR Weasel Conductor |
135 | Shackle insulator |
136 | Galvanized Nuts and Bolts. |
137 | Danger Plates with Clamps |
138 | Anti climbing device with clamps |
139 | Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip |
140 | Painting of 8 mtr ST poles with two coat of Aluminium Paint |
141 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
142 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSS Pinger (Old Stage Zero). |
143 | 9 mtr. Long ST Pole (ST-410 SP-33) |
144 | GI V Cross -arm with top Bracket including clamps |
145 | GI Channel X-arm including clamps and Angle for braces |
146 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
147 | 30mm² ACSR Weasel Conductor |
148 | PG Clamps |
149 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
150 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
151 | Galvanized Nuts and Bolts |
152 | Danger Plates with Clamps |
153 | Anti climbing device with clamps |
154 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
155 | Painting of 9 mtr ST poles with two coats of Aluminiumpaint. |
156 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
157 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
158 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for creation of 63 KVA Sub stn. at WSS Pinger (Old Stage Zero) |
159 | 11/0.433 KV, 3-phase distribution Transformer 63 KVA with Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & with LV Cable box having detachable Aluminium Gland plate |
160 | Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
161 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
162 | 11 KV Horn gap fuse set 3 phase 200 A |
163 | 120mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
164 | 9 mtr. Long ST poles (ST-410 SP33) |
165 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
166 | GI Channel /Angle/flat of sizes including clamps |
167 | Galvanized Nuts and Bolts. |
168 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
169 | 11 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm |
170 | LT distribution box for 100 KVA DTR with MCCB for incomer and SFU"s for outgoing circuits |
171 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
172 | PG Clamps |
173 | Danger Plates with Clamps |
174 | GI Barbed wire for Anticlimbing |
175 | 3-Phase 4 Wire LT Prodigy Meter with Box. |
176 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
177 | Painting of ST poles 9 mtr. Long with 1 coat of Red oxide & 2 coat of Aluminum paint. |
178 | Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS Pinger (Old Stage Zero). |
179 | 8 mtr. Long ST poles (ST-410 SP15) |
180 | GI M Clamps for shackle insulator |
181 | 30mm²ACSR Weasel Conductor |
182 | Shackle insulator |
183 | Galvanized Nuts and Bolts. |
184 | Danger Plates with Clamps |
185 | Anti climbing device with clamps |
186 | Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip |
187 | Painting of 8 mtr ST poles with two coat of Aluminium Paint |
188 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
189 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSS Pinger (Old Stage First). |
190 | 9 mtr. Long ST Pole (ST-410 SP-33) |
191 | GI V Cross -arm with top Bracket including clamps |
192 | GI Channel X-arm including clamps and Angle for braces |
193 | 30mm² ACSR Weasel Conductor |
194 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
195 | PG Clamps |
196 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
197 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
198 | Galvanized Nuts and Bolts |
199 | Danger Plates with Clamps |
200 | Anti climbing device with clamps |
201 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
202 | Painting of 9 mtr ST poles with two coats of Aluminiumpaint. |
203 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
204 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
205 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for creation of 63 KVA Sub stn. at WSS Pinger (Old Stage First) |
206 | 11/0.433 KV, 3-phase distribution Transformer 63 KVA with Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & with LV Cable box having detachable Aluminium Gland plate |
207 | Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
208 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
209 | 11 KV Horn gap fuse set 3 phase 200 A |
210 | 120mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
211 | 9 mtr. Long ST poles (ST-410 SP33) |
212 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
213 | GI Channel /Angle/flat of sizes including clamps |
214 | Galvanized Nuts and Bolts. |
215 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
216 | 11 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm |
217 | LT distribution box for 100 KVA DTR with MCCB for incomer and SFU"s for outgoing circuits |
218 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
219 | PG Clamps |
220 | Danger Plates with Clamps |
221 | GI Barbed wire for Anticlimbing |
222 | 3-Phase 4 Wire LT Prodigy Meter with Box. |
223 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
224 | Painting of ST poles 9 mtr. Long with 1 coat of Red oxide & 2 coat of Aluminum paint. |
225 | Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS Pinger (Old Stage First). |
226 | 8 mtr. Long ST poles (ST-410 SP15) |
227 | GI M Clamps for shackle insulator |
228 | 30mm²ACSR Weasel Conductor |
229 | Shackle insulator |
230 | Galvanized Nuts and Bolts. |
231 | Danger Plates with Clamps |
232 | Anti climbing device with clamps |
233 | Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip |
234 | Painting of 8 mtr ST poles with two coat of Aluminium Paint |
235 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
236 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSS Pinger (Old Stage Second). |
237 | 9 mtr. Long ST Pole (ST-410 SP-33) |
238 | GI V Cross -arm with top Bracket including clamps |
239 | GI Channel X-arm including clamps and Angle for braces |
240 | 30mm² ACSR Weasel Conductor |
241 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
242 | PG Clamps |
243 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
244 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
245 | Galvanized Nuts and Bolts |
246 | Danger Plates with Clamps |
247 | Anti climbing device with clamps |
248 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
249 | Painting of 9 mtr ST poles with two coats of Aluminiumpaint. |
250 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
251 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
252 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for creation of 63 KVA Sub stn. at WSS Pinger (Old Stage Second) |
253 | 11/0.433 KV, 3-phase distribution Transformer 63 KVA with Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & with LV Cable box having detachable Aluminium Gland plate |
254 | Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
255 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
256 | 11 KV Horn gap fuse set 3 phase 200 A |
257 | 120mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
258 | 9 mtr. Long ST poles (ST-410 SP33) |
259 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
260 | GI Channel /Angle/flat of sizes including clamps |
261 | Galvanized Nuts and Bolts. |
262 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
263 | 11 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm |
264 | LT distribution box for 100 KVA DTR with MCCB for incomer and SFU"s for outgoing circuits |
265 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
266 | PG Clamps |
267 | Danger Plates with Clamps |
268 | GI Barbed wire for Anticlimbing |
269 | 3-Phase 4 Wire LT Prodigy Meter with Box. |
270 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
271 | Painting of ST poles 9 mtr. Long with 1 coat of Red oxide & 2 coat of Aluminum paint. |
272 | Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS Pinger (Old Stage Second). |
273 | 8 mtr. Long ST poles (ST-410 SP15) |
274 | GI M Clamps for shackle insulator |
275 | 30mm²ACSR Weasel Conductor |
276 | Shackle insulator |
277 | Galvanized Nuts and Bolts. |
278 | Danger Plates with Clamps |
279 | Anti climbing device with clamps |
280 | Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip |
281 | Painting of 8 mtr ST poles with two coat of Aluminium Paint |
282 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
283 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSS Pinger (New Stage Zero). |
284 | 9 mtr. Long ST Pole (ST-410 SP-33) |
285 | GI V Cross -arm with top Bracket including clamps |
286 | GI Channel X-arm including clamps and Angle for braces |
287 | 30mm² ACSR Weasel Conductor |
288 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
289 | PG Clamps |
290 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
291 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
292 | Galvanized Nuts and Bolts |
293 | Danger Plates with Clamps |
294 | Anti climbing device with clamps |
295 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
296 | Painting of 9 mtr ST poles with two coats of Aluminiumpaint. |
297 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
298 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
299 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Installation of 2x100 KVA Substation at WSS Pinger (New Stage-Zero) |
300 | 11/0.433 KV, 3-phase distribution Transformer 100 KVA with Bimetallic Terminal Connectors Energy Level-2 AluminiumWound, & with LV Cable box having detachable Aluminium Gland plate |
301 | Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
302 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
303 | 11 KV Horn gap fuse set 3 phase 200 A |
304 | 185mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
305 | 9 mtr. Long ST pole (ST-410 SP-33) |
306 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75Positive and 80 KV Negative, creepage distance 320mm with fitting |
307 | GI Channel /Angle/flat of sizes including clamps |
308 | Galvanized Nuts and Bolts. |
309 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
310 | 11 KV Poloymer composite pin insulator, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm |
311 | LT distribution box for 100 KVA DTR with MCCB for incomer and SFU"s for outgoing circuits |
312 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
313 | PG Clamps |
314 | Danger Plates with Clamps |
315 | GI Barbed wire for Anticlimbing |
316 | 3-phase 4-wire Prodigy meter with box |
317 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
318 | Painting of ST poles 9 mtr. Long with 2 coat of Al. paint |
319 | Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS Pinger (New Stage Zero). |
320 | 8 mtr. Long ST poles (ST-410 SP15) |
321 | GI M Clamps for shackle insulator |
322 | 30mm²ACSR Weasel Conductor |
323 | Shackle insulator |
324 | Galvanized Nuts and Bolts. |
325 | Danger Plates with Clamps |
326 | Anti climbing device with clamps |
327 | Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip |
328 | Painting of 8 mtr ST poles with two coat of Aluminium Paint |
329 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
330 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSS Pinger (New Stage First). |
331 | 9 mtr. Long ST Pole (ST-410 SP-33) |
332 | GI V Cross -arm with top Bracket including clamps |
333 | GI Channel X-arm including clamps and Angle for braces |
334 | 30mm² ACSR Weasel Conductor |
335 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
336 | PG Clamps |
337 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
338 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
339 | Galvanized Nuts and Bolts |
340 | Danger Plates with Clamps |
341 | Anti climbing device with clamps |
342 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
343 | Painting of 9 mtr ST poles with two coats of Aluminiumpaint. |
344 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
345 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
346 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Installation of 2x100 KVA Substation at WSS Pinger (New Stage-First) |
347 | 11/0.433 KV, 3-phase distribution Transformer 100 KVA with Bimetallic Terminal Connectors Energy Level-2 AluminiumWound, & with LV Cable box having detachable Aluminium Gland plate |
348 | Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
349 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
350 | 11 KV Horn gap fuse set 3 phase 200 A |
351 | 185mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
352 | 9 mtr. Long ST pole (ST-410 SP-33) |
353 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75Positive and 80 KV Negative, creepage distance 320mm with fitting |
354 | GI Channel /Angle/flat of sizes including clamps |
355 | Galvanized Nuts and Bolts. |
356 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
357 | 11 KV Poloymer composite pin insulator, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm |
358 | LT distribution box for 100 KVA DTR with MCCB for incomer and SFU"s for outgoing circuits |
359 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
360 | PG Clamps |
361 | Danger Plates with Clamps |
362 | GI Barbed wire for Anticlimbing |
363 | 3-phase 4-wire Prodigy meter with box |
364 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
365 | Painting of ST poles 9 mtr. Long with 2 coat of Al. paint |
366 | Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS Pinger (New Stage First). |
367 | 8 mtr. Long ST poles (ST-410 SP15) |
368 | GI M Clamps for shackle insulator |
369 | 30mm²ACSR Weasel Conductor |
370 | Shackle insulator |
371 | Galvanized Nuts and Bolts. |
372 | Danger Plates with Clamps |
373 | Anti climbing device with clamps |
374 | Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip |
375 | Painting of 8 mtr ST poles with two coat of Aluminium Paint |
376 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy