Tender For Repair Replacement Of Internal Wiring Electrical Fittings Fixture Renewal Of Bldg Earthing Ceiling Fans Exhaust Fans Geysers Spilt Window Type Air Conditioners Water Coolers Deep Freezer And Allied Works In Ro Otm Md Accn Army Dgqa And, bangalore-Karnataka

Military Engineer Services-MES has published Tender For Repair Replacement Of Internal Wiring Electrical Fittings Fixture Renewal Of Bldg Earthing Ceiling Fans Exhaust Fans Geysers Spilt Window Type Air Conditioners Water Coolers Deep Freezer And Allied Works In Ro Otm Md Accn Army Dgqa And. Submission Date for this Tender is 30-01-2024. Electrification Work Tenders in bangalore Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

41506921
Corrigendum : Tender For Repair Replacement Of Internal Wiring Electrical Fittings Fixture Renewal Of Bldg Earthing Ceiling Fans Exhaust Fans Geysers Spilt Window Type Air Conditioners Water Coolers Deep Freezer And Allied Works In Ro Otm Md Accn Army Dgqa And
Open Tender
Indian
Karnataka
bangalore
30-01-2024

Tender Details

Repair Replacement Of Internal Wiring Electrical Fittings Fixture Renewal Of Bldg Earthing Ceiling Fans Exhaust Fans Geysers Spilt Window Type Air Conditioners Water Coolers Deep Freezer And Allied Works In Ro Otm Md Accn Army Dgqa And

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-01-2024
2 25-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 76000.0 /-
Tender Value
INR 38 Lakhs /-

BOQ Items

Name of Work : REPAIR / REPLACEMENT OF INTERNAL WIRING ELECTRICAL FITTINGS / FIXTURE, RENEWAL OF BLDG EARTHING, CEILING FANS, EXHAUST FANS, GEYSERS, SPILT / WINDOW TYPE AIR CONDITIONERS, WATER COOLERS, DEEP FREEZER AND ALLIED WORKS IN R/O OTM/MD ACCN ARMY, DGQA AND NAVY AREAUNDER GE (NORTH) BANGALORE.
Sl. No. Item Description
1Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, call bell socket or power circuits) completeand making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
2Point wiring completewith 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concealed in walls incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls withlaminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch
3As per item No 2 above but for One fan point controlled by one switch/regulator
4As per item No 2 above but for One light point controlled by 2 way switch
5As per item No 2 above but for One 3 pin socket out let 5 Amps on independent board
6As per item No 2 above but for One bell / buzzer point controlled by bell push
7As per item No 2 above but for One 3 pin socket out let 5 A on same board
8Point wiring completewith 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiringincl GI/ MS brandedsunken boxes of suitable module concealedon walls including modular frame and cover of suitable modulefixed with cadmium plated iron screws for housing modular typeswitches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch
9As per item No 8 above but for One fan point controlled by one switch / regulator
10As per item No 8 above but for One light point controlled by 2 way switch
11As per item No 8 above but for One 3 pin socket out let 5 Amps on independent board
12As per item No 8 above but for One bell / buzzer point controlled by bell push
13As per item No 8 above but for One 3 pin socket out let 5 A on same board
14All as per item No 2 but concealed wiring drawn through existing PVC conduit. One light point controlled by one switch
15As per item No 14 above but for One fan / Exhaust point controlled by one switch / regulator
16As per item No 14 above but for One light point controlled by 2 way switch
17As per item No 14 above but for One 3 pin socket out let 5 Amps on independent board
18As per item No 14 above but for One bell / buzzer point controlled by bell push
19As per item No 14 above but for One 3 pin socket out let 5 A on same board
20Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through non-metalic existing PVC conduit medium density ISI markedincl accessories surface type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
21Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductorcable as earth continuity conductor, drawn through existing non metallic rigid PVC conduit and conduit accessories all as specified and as directed. Note : 3 runs of cable will be measured as unit length for payment.
22Point wiring completewith 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC Casing & CapingISI marked incl accessories surface type wiringincl 1.6 mm thick MS sunken boxes concealedon walls includinglaminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch
23As per item No 22 above but for One fan point controlled by one switch / regulator
24As per item No 22 above but for One light point controlled by 2 way switch
25As per item No 22 above but for One 3 pin socket out let 5 Amps on independent board
26As per item No 22 above but for One bell/buzzer point controlled by bell push
27As per item No 22 above but for One 3 pin socket out let 5 A on same board
28Point wiringcomplete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI markedincl accessories concealedtype run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheetconcealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
29Point wiring completewith 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC casing capingISI marked incl incl accessories surface type wiring run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheetconcealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. Note for Item No 2 to 29 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii)Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit ofany length of cablefrom DB to any switch/ socket board to be included in point wiring. (v) Quoted rate is inclusive of cutting chases for concealed wiring including making good the distrubed surfaces.
30S&F LED batten suitable for indoor applications 20 Watts,4 feet with extruded aluminiumhousing & integrated LED channelcomplete with all accessories including taking out old fittings all as specified and directed. Make: Bajaj, Cat No.BCLAB20 WH LED P or equivalent Makes & model in Havells / CG / Philips
31S&F LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic covercomplete with all accessories including taking out old fittings all as specified and directed. Make: Bajaj, Cat No.BCLSB 10 WH or equivalent Makes &modelin Havells / CG / Philips
32S&F 2" x 2" Recess mountedLED Luminaire36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZRSQL 36W GZi WH or equivalent Makes & modelin Havells / CG / Philips
33S&F 1" x 1" Surface mountedLED Luminaire24 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZSSQL 24W LED WHI or equivalentin Havells / CG / Philips
34S&F Bulkhead LEDluminaries 10 watt energy efficient solution for upgrading convertional with IP 65 ncluding taking out old fittings as specified and directed. Make: Bajaj, Cat No : BIBWP10WLED or equivalentin Havells / CG / Philips
35Supply and Fix Modular switch 1 way 6A,1 module
36Supply and fix Modular switch 1 way 16A, 1 module
37Supply and fix Modular switch 2 way 6A,1 module
38Supply and Fix Modular Bell push 6A 1 module
39Supply and fix modular Socket, 6A - 2/3 pin combined 2 module
40Supply and fix modular Socket 6A/16A - 2/3 pin combined 2 module,
41Supply and fix modular type Fan step regulator, 120W - 2 module
42S&F in replacement of of Switch piano flush button single pole two way 5 Amps all as specified and as directed.
43S&F in replacement of Angle holder PVC / polycarbonate type all as specified and as directed
44S&F in replacement of switch piano flush type single pole one way 5 Amps
45S&F in replacement of switch socket combination5 pin2 in 1, 5 A Flush typeall as specified and asdirected
46S&F in replacement of switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and asdirected
47S&F in replacement ofsocket outlet 2 in 1, 3 pin 5 A all as specified and asdirected
48S&F in replacement of bell push flush type 5A all as specified and asdirected .
49S&F in replacement ofMCB SPN 240 volts 32/40 Amps complete all as specified and as directed
50S&F in replacement of MCB single pole 240 volts 5-32 Amps complete all as specified and as directed
51S&F in replacement ofMCB TPN 415 volts, 10KA "C" curve 63 Amps complete all as specified and as directed
52S&F in replacement ofMCB TPN 415 volts, 10KA "C" curve100 Amps complete all as specified and as directed
53S&F in replacement of MCB DB SPN 4 way double door type 240 volts with 200 Amps rated busbaras specified and as directed.
54S&F in replacement of MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbaras specified and as directed.
55S&F in replacement ofMCB DB TPN 4 way with double door type415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed.
56S&F in replacement ofceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
57S&F in replacement of stepped type electronic fan regulator flush Switch/socket type all as specified and as directed
58S&F in replacement ofDing Dong bellAC 230 volts single pole.
59S&L sub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with suitable size PVC conduit all as specified and as directed incl taking down old unsv cable complete.
60S&L sub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with suitable size PVC conduit all as specified and as directedincl taking down old unsv cable complete.
61S&L sub main wiring1100 volts grade multistranded FRLS copper conductors, two runs of single core 2.5 Sqmm along with 2.5 Sqm PVC insulatedsingle core multistranded copper conductor cable as earth continuity conductor run along with suitable size PVC conduit all as specified and as directedincl taking down old unsv cable complete. Note for items Nos 59 to 61: 3 runs of cable and one run of conduit will be measured as unit length.
62M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.
63S&F LED lamp suitable to fit in angle holder of capacity 09 watt. Make: Bajaj or equivalent in Philips/Havells/CG.
64Supply and fixing30 WLED bldg securitylight fittingwith pressure die cast housing along with prismatic polycarbonate difuser with IP 66protection including taking out old fittings. Make:- Bajaj, Cat No.:- ENXT P 30L WH SY PC SD or Equivalent Makes & modelin Havells / CG / Philips
65S&F Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and including before fixing applying two coats of aluminum paintover a coat of red oxide primer including removing the old existing GIbracket from bldg complete all as specified and directed.
66S&F Storage type water heater with steel body 25 Ltrs BEE 5 star ratedcomplete incl steel wired pipe for hot/cold water connection for inlet and out let wateretc completeall as specified and directed at site. Make Bajaj. Model No CALENTA 150801 or equivalent on Venus / Havells)
67S&F ceiling fans complete with complete accessories, 230V, SP 1200 mm Sweep with BEE 3 Star rating complete with all accessories and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directed (Against BER). Make Bajaj, SABSE TEZZ EE 03. Model No 251120 and equivalent model in Havells/CG/ USHA.
68S&F Exhaust fansAC single phase 230/ 240 V of size 250/280/300/400 mm sweep with louvers fixed outside withall accessories and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm , etc all as directed. Make :Bajaj cat No : 70079, MAXX AIR or equivalent make in Havells / CGs / Orient
69M&L louver of exhaust fan suitable for 300 / 230 mm sweep complete accessories all as specified and directed
70M&L louver of exhaust fan suitable for 450 mm sweep complete accessories all as specified and directed
71S&F in replacement PVC Fresh air fan of 150mm sweep 1200/1400 RPM with louver. Make CG/Usha/ Orient/Phillips/Bajaj.
72S&F in replacement PVC Fresh air fan of 200/225mm sweep 1200/1400 RPM with louver. Make CG/Usha/ Orient/Phillips/Bajaj.
73S&F in replacement PVC Fresh air fan of 250/300mm sweep 1200/1400 RPM with louver. Make CG/Usha/ Orient/Phillips/Bajaj.
74S&F in replacement of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20 Amps.
75Inspection, taking down, dismantling of geysers of any type / capacity, cleaning, descaling, reassembling & reinstallation on the old place incl hydraulic pressure test of container with hand operated hydraulic pump complete, brazing inner tank, internal wiring and reinstallation after necessary repair / replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately.
76Supply only stainless/Mild steel inner tank of capacity 25 ltrs unit including internally assembly of any size and type complete all as specified & as directed.
77Supply onlyinternal assembly/apparatus rod unit of any size and type of capacity 25 ltrs complete all as specified & as directed.
78Supply only heating element of 2 KW rating triangular/round typeas per existing size and type including rubber washers all as specified & as directed.
79Supply only heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed.
80Supply only Thermostat/auto cut off of suitable size and type for 25/50 Ltrs capacity of any size.
81Supply only Indicator lamp red and green type square/round.
82Supply only Safety valve/high pressure valve/NRV of exisitng type ISI marked.
83Supply only PVC insulated Copper cable flexible 3 coreof size 40/0.0076ISI marked.
84Supply only outer cover of geyser for capacity 25 ltrs unit complete with all fitting and fixtures as specified & as directed.
85Supply only PVC flexible pipe 16mm dia 450mm long with 2 Nos of brass ferrule & rubber washer for hot and cold water all as specified & as directed. (Set of 2)
86Supply only stainless/Mild steel inner tank of capacity 50 ltrs unit complete with all fitting and fixtures all as specified & as directed.
87Supply onlyinternal assembly/apparatus rod unit of any size and type of capacity 50 ltrs complete all as specified & as directed.
88Supply only outer cover of geyger for capacity 50 ltrs unit complete with all fitting and fixtures as specified & as directed.
89M&L for Preparation old painted surface & painting the geyser complete after cleaning & applying the same one coat of spray paint of white enamel, writing MES No includingtaking down and refixing in same or other place complete all as specified & as directed by Engr -in-Charge.
90Taking down ceiling fan 1200mm/1400mm and wall mounted fan 300/450 mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin,rubber pully etc., includingrefixingand connecting the same complete all as specified and as directed.
91Inspection, disconnecting electric connecting and dismantling of ceiling fan/exhaust/wall mounted fan of any type/size, cleaning including oiling and greasing the bearing, tighting of nuts and bolts and refixing on the old place complete after necessary repair / replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately.
92Supply only ball bearing of various sizes / make as required for ceiling fans/wall mounting / exhaust fan includinggreasing complete all as specified and as directed.
93Supply only Gun metal bush of any size / make suitable for ceiling fans all as specified and as directed.
94Supply only capacitor 2.5 Mfd suitable for ceiling / exhaust / wall mounting fans complete all as specified and as directed.
95Supply only capacitor 4.0 Mfd suitable for ceiling / exhaust / wall mounting fans complete all as specified and as directed.
96PVC flexible cable twin twisted core of 23/0.0076 size multi stranded copper conductor suitable for connecting ceiling fans / exhaust /wall mounting fans complete all as specified and as directed.
97Rubber bush with MS bolts, nuts & washers with "U" clamps for ceiling fans complete all as specified and as directed.
98Supply only motor rotar ring for ceiling fans complete all as specified and as directed.
99Supply only motor stator for ceiling fans complete all as specified and as directed.
100Supply only down rod of 30/45 cm with nut, bolts and safety pin for ceiling fans complete all as specified and as directed.
101Supply only plastic cup with screw for ceiling fans complete all as specified and as directed.
102Dismantling /opening the ceiling fan of 1200 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling/re-fixing in its p complete all as specified and as directed.
103Dismantling /opening the ceiling fan of 1400 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
104Dismantling /opening the wall mounted fan of 300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
105Taking down exhaust fans 230 mm/300mm / 450mm sweep from position by duly disconnecting electric lines,preparing the surfaces,filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin,rubber pully etc., includingrefixingand connecting the same complete all as specified and as directed.
106Dismantling /opening the exhaust fan of 230 mm/300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
107Dismantling /opening the exhaust fan of 450 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. Note :For SlItem No. 102 to 107 :- Cost of spares will be measured and paid separately.
108S&F in replacement of exhaust fansmotor upto 280/300 mm sweep, heavy duty, 1400 RPM,AC single phase 230/240 Vwith blades complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or Equivalent make.
109S&F in replacement of exhaust fansmotor upto 225/230 mm sweep, heavy duty, 1400 RPM,AC single phase 230/240 Vwith blades complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or Equivalent make.
110S&F in replacement of exhaust fansouterframe for holding exhaust fan motor upto 280/300 mm sweep with supporting angle complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or Equivalent make.
111S&F in replacement of exhaust fansouterframe for holding exhaust fan motor upto 225 / 230 mm sweep with supporting angle complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or Equivalent make.
112M&L extension of down rod for ceiling fanupto 1.5 mtr including nut, bolts, washers complete accessories all as specified and as directed.
113Removing the window type AC/Split type AC of 1.0/1.5/2.0 ton capacity from location servicing the AC, cleaning the condenser and evaporator coil by blower, checking the electrical wiring, repalcement of burnt out wiring terminals, cleaning the air filter, gas charging, adjusting relays etc., replacement of unserviceable spare parts and fixing back atlocation, testing and commissioning complete allas directed.
114All as per item No 113here-in-before, but for water coolers of the following capacities:- 40/60/80 ltrs capacities
115As per item No 113 above but water cooler of 120/150 ltrs capacities
116All as peritem No 113 here-in-before, but for refrigerators/Deep freezer of the following capacities:- 165/180 /220 ltrs capacities
117As per item No 116 above but for refrigerator / deep freezer 286/310/320 ltrs capacities
118Removing the split type AC of any make from position transporting to a reputed workshop, cutting the suction and discharge line of unserviceable compressor and replace withnew factory made hermatically sealed compressor of same make and type, connecting the suction and discharge line, vacuuming the entire system, arresting all leakages, charging of required quantity of refrigerant, adjusting relays, thermostat etc bringing back and installing in its original position incl testing and commissioning complete all as directedfor the following capacities:- 1.5 ton capacity
119As per item No 118 above but for 2.0 ton capacity
120All as per item No 118 here-in-before, but for water cooler/refrigerators/deep freezer of following capacities. 40/60/80 ltrs capacities water cooler
121As per item No 118 above but for 120/150 ltrs capacities water cooler
122As per item No 118 above but for 165/180 ltrs capacities refrigerators
123As per item No 118 above but for 220 ltrs capacities Deep freezer
124As per item No 118 above but for 286 / 310 / 320 ltrs capacities refrigerators / Deep freezer Note for item No 113 to 124 :- (i)Gas will be measured and paid separatelyunder relevent item of this schedule. (ii) Spares other than minor spares will be measured and paid seperately under relevent item of this schedule.
125Labour only for charging of refrigrent gas (R-22/410A/134A) of required quantity for split/window type AC including leak detection by using nitrogen gas and arresting leakages if any by necessary brazing and flushing the system complete and testing complete for the following capacities: 1.5 Ton
126As per item No 125 above but for 2.0 Ton AC
127All as per item No 125 here-in-before, but for water cooler storage type of following capacities 40/60/80 ltrs capacity
128As per item No 125 above but for 120/150 ltrs capacity water cooler
129All as per item No 125 here-in- before, but for refrigerators/deep freezerof following capacities:- 165/220 ltrs capacities
130As per item No 125 above but for 286/310/320 ltrs capacities refrigerator / deep freezer
131Painting of water coolers with two coats of enamel paint of existing colour all as directed over a coat of primer after welding the base plate with MS angle iron frameof existing size removing dust, tinkering, applyingmetal putty wherever necessary incl writing of SM/MES No all as directed by Engineer-in-Charge for water coolers of following capacity:- 40/80 ltrs capacities
132As per item No 131 above but for 120/150 ltrs capacities water cooler
133Removing the unserviceable blower motor from the window type AC/Spilit type AC, removing the burnt out winding from slots, rewinding with superior quality copper winding wire of higherinsulation level, varnishingdrying the motorcomplete and fixing in position incl testing and commissioning for 1.5/2 ton capacity
134All as per item No 133 above but for water cooler of following capacity:- 40/80 ltr capacity
135As per item No 133 above but for 120/150 ltr capacity water cooler
136All as per item No 133 above but forrefrigerators/deep freezerof following capacities:- 165/220 ltrs capacities
137As per item No 136 above but for 286/310/320 ltrs capacities refrigerator / deep freezer
138Supply and replacing of worn out bearing and gun metal bushes of appropriate size and testing complete for the following water coolers :- 40/80 ltr water cooler
139As per item No 138 above but for 120/150 ltr water cooler
140Removing the damaged/unserviceable fan blades from the condenser motor shaft and replace new fan blade of the same size and type for any capacity of window type AC and water coolers all as specified and directd.
141Removing the unserviceable thermostat and Supply and fix new thermostat of same make and type for Split/window type AC 1.5/2 ton capacity. (Make- Indfos/Danfoss)
142Removing the unserviceable thermostat and Supply and fix new thermostat of same make and type for the following :- (Make- Indfos / Danfoss) Split / window type AC 1.5 / 2 ton capacity
143All as per item No. 142 above but for Water Cooler 40/60/80 ltrs capacity
144All as per item No. 142 above but for Water Cooler 120/150 ltrs capacity
145All as per item No. 142 above but for Refrigerator 165/220 ltrs capacity
146All as per item No. 142 above but for Refrigerator 286/310/320 ltrs capacity
147Removing the unserviceable potential relay and Supply and fix relay of same make and type for the following:- Water cooler 40/60/80 ltrs capacity
148As per item No 147 above but for Water cooler 120/150 ltrs capacity
149Removing the unserviceable condenser unit & supply & fix new condenser unit connecting to the discharge line, brazing, vaccumising & gas charging the unit with required quantity of refrigerant for water cooler upto 120/150 Ltrs capacity and testing complete allas directed.
150Removing the unserviceable condenser unit & supply & fix new condenser unit connecting to the discharge line, brazing, vaccumising & gas charging the unit with required quantity of refrigerant for refrigerator/Deep Freezer 165/175/286/310/320 Ltrs capacity and testing complete allas directed.
151Removing the unserviceable condenser unit & supply & fix new condenser unit connecting to the discharge line, brazing, vaccumising & gas charging the unit with required quantity of refrigerant for Split/window type AC of 1.5/2 Ton capacity and testing complete allas directed.
152Removing the unserviceable LMS from the refrigerator Supply and fix newrelay of same make and type for refrigeraters/ deep freezes of following capacities:- 165/175/220 ltrs
153As per item No 152 above but for 286/310/320 ltrs
154Removing / Dismantling unserviceable evaporator freezer box unit incl door cover and providing new & connecting the refrigerant pipe lines, peak testing, vacuuming and gas charging the unit with required quantity of refrigerant for refrigerator of 286/310 ltrs capacity and testing complete allas directed.
155All as per item No 154here-in-before, but for refrigerator of 165/175/220 ltrs capacity
156Removing the damaged/ unserviceable refrigerator/Deep freezermagnetic gasket of door and replacing with new door gasket of same type and size incl making good the surfaces for proper seating of the door for the following capacities 165/175/220 ltrs
157As per item No 156 above but for 286/310/320 ltrs
158Removing the unservicable running capacitor of 40 MFD, Supply and fix of new capacitorsuitable for 1.5 ton AC make :- BHEL / EPCOS/ TDK/ TIBCON or equivalent.
159All as per item No 158 herein before, but starting capacitor of 60/80 MFD for water cooler.
160All as per item No 158 herein before, but starting capacitor of 80/100 MFD for 1.5 TR/2 TR AC.
161Removing the unservicable over load protection and Supply and fix new over load protector for split/window type AC of 1.5/2.0 TR capacity.
162Removing the unservicable metal push cock 15mm dia from water cooler and Supply and fix new push cock of same type all as directed.
163Removing the unservicable PVC ball valve 15mm dia incl float and replace with new PVC ball valve of 15mm dia for water coolers of any make and size all as specified and directed.
164Removing the unservicable PVC flexible pipe and Supply and fix new PVC flexible pipe of existing size for water outlet of water cooler/AC.
165Disconnecting and removing the damaged unservicable supply cord for cooling appliances and Supply and fix new PVC insulated 3 core 2.5 Sqmm multi stranded copper conductor cable complete allas directed.
166S&F in replacement of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20 Amps.
167Supply and fill refrigrent gas (R-22/410A/134A) for domestic cooling appliance.
168Supply and fill refrigrent gas (R-22/410A/134A) for domestic coolingappliance.
169Disconnecting and taking out the unservicable sensor/remote unit completely and supply and fix new sensor unit of indoor unit of AC to suit the AC of Makes carrier/Bluestar/Voltas 1.5 Ton Split type AC
170As per item No 169 above but for 2 Ton Split type AC
171Disconnecting and taking out the unservicable PCB, refixing new PCB for split AC / window AC any type and any make 1.5 Ton, 2 Toncapacity all as directed. 1.5 Ton Split type AC
172As per item No 171 above but for 2 Ton Split type AC
173Disconnecting and taking PCB circuit of disconnecting out PCB from split AC, repairing the same and refixing in original location complete all as specified and directed for 1.5/2 Toncapacity all as directed.
174Disconnect electrical connection, removing copper line, discharge line of split type AC upto 2 Ton capacity including indoor and out door units and all accessories and shifting/reinstalling and testing the whole unit of split type AC in new location with suitable size and length of copper pipe and making the holes in walls complete all as specified.
175Supply and fix plastic/coir filter suitable for Split/window type AC 1.5/2 Ton capacity including taking down old unsv filter etc complete all as specified and as directed.
176Supply and fix voltage stabilizer suitable for Split/window type AC 1.5/2 Ton capacity complete all as specified and as directed. Make : V Guard/Everest/ Sinotech 1 KVA
177As per item No 176 above but for 2/3 KVA
178As per item No 176 above but for 5 KVA
179S&F in replacement of brass angle valve for gas charging for split AC 1.5/2 ton of AC compete all as specified and as directed.
180S&F in replacement of swing motor of existing capacity and type for indoor unit of split AC fins complete all as specified and as directed
181S&F in replacement ofMS fabrication clamps for hanging, fan including hook as existing complete all as specified and as directed
182S&F in replacement ofNitrile rubber insulation for suction and dischaged pipe of split type AC of size 15/19 mm dia complete all as specified and as directed.
183S&F in replacement of Soft copper tubbing 15mm dia with nitrile rubber insulation for split type AC complete all as specified and as directed.
184S&F in replacement of Soft copper tubbing 19mm dia with nitrile rubber insulation for split type AC complete all as specified and as directed.
185Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TON complete (Against BER) all as specified and as directed. Make - Blue Star/Voltas/LG.
186S&F in replacement of brass flare nuts suitable for 1.5/2 ton of SplitAC complete all as specified and directed.
187All as per item No 186 here-in-before, but for water coolers of the following capacities:- 40/60/80 ltrs capacities
188As per item No 186 above but for 120/150 ltrs capacities water cooler
189All as peritem No 186 here-in-before, but for refrigerators/Deep freezer of the following capacities:- 165/180 /220 ltrs capacities
190As per item No 186 above but for 286/310/320 ltrs capacities refrigerator / deep freezer
191S&F in replacement of MCB single pole 240 volts 20/25 Amps complete all as specified and as directed