Military Engineer Services-MES has published Tender For Repair / Maintenance Of Various Capacity Dg Sets Along With Main Panel And Connected Items And Repair / Replacement Of Different Size Pipe Lines Along With Connected Items Including Connection To Pumps At Bb Cantt, Srinagar.. Submission Date for this Tender is 27-01-2024. Diesel Generators Tenders in Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | M&L for cleaning of radiator assembley by dismantling of canopy, removal of radiator, cleaning of radiator with chemical, sealing of radiator tube if any leakage, pressure testing of radiator,arrest leakage by bazing soldering incl freight (to & fro), loading, unloading, re-assembling of canopy complete all as specified and directed for the following capacities of DG sets:- |
2 | 320 to 400 KVA DG set |
3 | 250 KVA DG Set |
4 | 180 to 200 KVA DG Set |
5 | 75 to 125 KVA DG set |
6 | 62.5/63 KVA DG set |
7 | S&F in repair Rocker Arm Assy suitable forDG sets capacity mentioned in Item Nos. 1.01 to 1.05 described here-in-before complete all as specified and directed. |
8 | S&F in repair trapped valves ofsuitablesize for DG sets capacity mentioned in Item Nos. 1.01 to 1.05 described here-in-before complete all as specified and directed. |
9 | Dismantling fuel injection pump (FIP) transporting to workshop complete servicing of pump by replace plunger, springs, inlet and outlet ports, nozzles, delivery valve, suction valve, head after testing and other minor parts to achievs proper fuel automisation for four cylinder diesel engine complete all as specified and directed. |
10 | Dismantling fuel injection pump (FIP) transporting to workshop complete servicing of pump by replace plunger, springs, inlet and outlet ports, nozzles, delivery valve, suction valve, head after testing and other minor parts to achievs proper fuel automisation for six cylinder diesel engine complete all as specified and directed. |
11 | Dismantling unserviceable water pump assembly of following capacity of DG Sets by replacing of impeller, meachanical seal set screw with washer including steel welding to body if necessary for arresting leakage including nuts and bolts complete all as specified and directed and upto the entires satisfication of Engr-in-Charge. |
12 | DG Set 320 to 400 KVA |
13 | DG Set 250 KVA |
14 | DG Set 180 to 200 KVA |
15 | DG Set 125 to 160 KVA |
16 | DG Set 62.5 to 100 KVA |
17 | M&L for scraping down the old rusted surface of LT panel board (internally and externally both) indoor type with steel wire brushes, sand paper cleaning the surface neatly and applying one coat of metal primer and two coats of synthetic enamel paint (siemen gray) with spray gun in DG Set installations including foundations, angle iron frames incl taking out all internal accessories from different LT panels after proper shutdown from the respective sub station and fixing the same after painting by using proper spreader link, thimbles etc complete all as per site requirement all as specified and directed. Note:- Contractor is bound to carry out paint work to any size of Panel before quoting of rate contrator must visit the site. |
18 | Supply and lay in replacement of synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed. |
19 | Supply and lay in replacement of synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed. |
20 | Supply and lay in replacement of synthetic Rubber insulated mats 3 mm thick for voltage upto 33 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed. |
21 | Taking down out door Disel Generator Set /transformer from platform structure lowering the same carefully by means of chain pulley block and all other required T&P and re-installation after repairs of the platform with PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) including necessay use and wastye of formwork complete all as specified and directed. |
22 | Shifting ofDisel Generator Set /transformer from one platform structure to another platform structure inside any place in BB Cantt perimises by means of hydraullic lifter after disconnecting all electrical connections carefully and connecting the same on new location after placing on plateform complete all as specified and directed. |
23 | S&F in replacement of breather of internal thread dia 20 to 25 mm, including 1 Kg/2 Kg silica gel capacity as per sample complete all as specified and directed. |
24 | M&L for cement concrete (1:2:4) type B0 using (12.5mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including demolition of concrete and rubbish off the same out of MoD land complete all as specified and directed. |
25 | M&L for fabrication and fixing rigidly glow sign board cubical box type in different sizes as requied at E/M installations made out of MS hollow square conduite pipe medium grade (25x25mm size) as frame and supporting base (AI 40x40x5mm) for flex sheet of superior quality, computerise machine printed letters and words, figures, arrow, dashes, commas etc all as directed in different colours, complete including energy saving LED lighting inside and prewired with suitable copper flexible twin core cord, fixed on building, wall, gate or grouted on floors etc with solid angle iron vertical and horizontal frame member in PCC block of any specification (angle iron, PCC etc reqd for installation of board shall be included in quoted rates nothing extra shall be paid to contractor on this account) including taking down old boards complete all as specified and directed. Note:- Front side of the board shall only be measured and paid to the contractor |
26 | Servicing of self starter assembly of DG sets 24 voltsby disconnecting the self starter assembly from the engine and dismantling, cleaning all accessories, replacing worn-out parts like carbon brushes, penion of existingteeth, bendex bushes, Armature, solenoid Assy 24 volt contact plates, jumping levels and rewinding the u/s field coil etc and varnishing complete all as specified and directed. |
27 | M&L forcomplete dismantling ofengine, opening of fuel filter, oil filter, Air filter, engine gasket set, grinding cutting, polishing of crank shaft to obtain mirror finish, grinding polishing of heads of 180/200/320/400 KVA DG Sets all as directed and all as per manufacture"s instruction resetting/ readjusting all component/ parts reassembling testing on load engine complete all as specified and directed. Note:- 1. Servicing of DG sets will be done by Authorised dealer by OEM only 2. Wornout/ unserviceable parts required to be replaced shall be paid as supply only under respective items described here-in-below:- |
28 | Piston |
29 | Piston Ring |
30 | Piston Pin |
31 | Cylinder Liner |
32 | Lube oil pump |
33 | Bearing C/R |
34 | Oil sensor |
35 | Benjo Nuts |
36 | Copper washer |
37 | Timming Seal |
38 | Return Valve |
39 | Packing Kit |
40 | Rubber kit set |
41 | Dynamo alternator |
42 | K sealant |
43 | Main oil seal |
44 | Head Gasket |
45 | Water Body |
46 | Cam gear Bush |
47 | Connecting Rod |
48 | Main begin bearing |
49 | Inlet / Exhaust valve |
50 | Valve oil seal |
51 | Valve guide |
52 | Valve Spring |
53 | Valve seat inlet/ Exhaust |
54 | Crank assembly |
55 | Poly V belt |
56 | Solonite switch |
57 | Turbo charger |
58 | GCU 12 V |
59 | LLOP sensor |
60 | Master relay & Base |
61 | Charging flash with Holder |
62 | Automatic voltage control of 320 KVA DG set |
63 | GCU 24 V with control card |
64 | Harness Wiring |
65 | Governor Control Unitfor 400 kVA DG set |
66 | Actuator including calibration of fuel injecter pump for 400 kVA DG set |
67 | Relay for control panel of 400 kVA DG set |
68 | Control cardfor control panel of 320/400 kVA DG set |
69 | Pipe adapter |
70 | Supply and laying MS water tubing 300mm (12 inch) bore, thick-ness 6mm with socket joints, medium grade galvanised including all fittings, such as sockets, bends, elbows, unions, tees laid in trenches and taking out unserviceable tube complete all as specified and directed. |
71 | Supply and laying GI water tubing 150mm (6 inch) bore, thick-ness 6mm with socket joints, medium grade galvanised including all fittings, such as sockets, bends, elbows, unions, tees laid in trenches and taking out unserviceable tube complete all as specified and directed. |
72 | All as per Srl Item No.19 here-in-before but of 100 mm bore of pipe complete all as specified and directed. |
73 | All as per Srl Item No. 19 here-in-before but of 80mm bore of pipe complete all as specified and directed. |
74 | All as per Srl Item No. 19 here-in-before but of 50mm bore of pipe complete all as specified and directed. |
75 | All as per Srl Item No. 19 here-in-before but of 40mm bore of pipe complete all as specified and directed. |
76 | All as per Srl Item No. 19 here-in-before but of 25mm bore of pipe complete all as specified and directed. |
77 | All as per Srl Item No. 19 here-in-before but of 20mm bore of pipe complete all as specified and directed. |
78 | All as per Srl Item No. 19 here-in-before but of 15mm bore of pipe complete all as specified and directed. |
79 | M&L for servicing of RO plant 50 LPH by replacement of new sediment filter, granular activated carbon filter, RO membrane, UF membrane, Post carbon including taking out unserviceable filters complete all as specified and directed. |
80 | M&L for servicing of RO plant 75 LPH by replacement of new sediment filter, granular activated carbon filter, RO membrane, UF membrane, Post carbon including taking out unserviceable filters complete all as specified and directed. |
81 | M&L for servicing of RO plant 100 LPH by replacement of new sediment filter, granular activated carbon filter, RO membrane, UF membrane, Post carbon including taking out unserviceable filters complete all as specified and directed. |
82 | M&L for servicing of RO plant 500 LPH by replacement of new sediment filter, granular activated carbon filter, RO membrane, UF membrane, Post carbon including taking out unserviceable filters complete all as specified and directed. |
83 | Supply and filling of filter media (carbon and sand) for RO plant including taking out unserviceable filter media complete all as specified and directed. |
84 | S&F motor capacity 300 GPD suitable for RO plant 100 LPH and taking out unserviceable motor complete all as specified and directed. |
85 | S&F solenoid valve including taking down unserviceable solenoid valve complete all as specified and directed. |
86 | S&F TDS switch including taking down unserviceable TDS switch complete all as specified and directed. |
87 | S&F sluice valve short body type of cast iron both ends flanged with rubber insertion and drilled of size 200mm dia confirming to IS 14846 with pressure rating of PN 1.6 with brass/copper alloy spindle and iron wheel head with nuts, bolts and washers of suitable size including taking down old unserviceable sluice valve complete all as specified and directed. |
88 | All as per srl item No. 35 here-in-before but of 150mm dia sluice valve complete all as specified and directed. |
89 | All as per srl item No. 35 here-in-before but of 100mm dia sluice valve complete all as specified and directed. |
90 | All as per srl item No. 35 here-in-before but of 80mm dia sluice valve complete all as specified and directed. |
91 | All as per srl item No. 35 here-in-before but of 50mm dia sluice valve complete all as specified and directed. |
92 | S&F cast Iron Non return valve, short body type, flanged ends heavy duty as per IS-5312, PN 1.6 of size 200mm dia with 6mm thick rubber insertion ring and taking down old unserviceable non return valve complete all as specified and directed. |
93 | All as per Srl Item No. 40 here-in-before but of 150mm dia non return valve complete all as specified and directed. |
94 | All as per Srl Item No. 40 here-in-before but of 100mm dia non return valve complete all as specified and directed. |
95 | All as per Srl Item No. 40 here-in-before but of 80mm dia non return valve complete all as specified and directed. |
96 | S&F brass/Gun metal, globe or gate valves of size 50mm bore dia with all GI fittings, iron wheel head,screwed both ends for iron pipe and fixed including taking down old unserviceable gate valve complete all as specified and directed. |
97 | All as per Srl Item No. 44 here-in-before but of 40mm dia gate valve complete all as specified and directed. |
98 | All as per Srl Item No. 44 here-in-before but of 25mm dia gate valve complete all as specified and directed. |
99 | All as per Srl Item No. 44 here-in-before but of 20mm dia gate valve complete all as specified and directed. |
100 | All as per Srl Item No. 44 here-in-before but of 15mm dia gate valve complete all as specified and directed. |
101 | S&F cast iron air release valve with double air outlets and fixing up in MS/CI/GI mains of size 50 mm dia,including MS flange, cutting/welding works required at site including taking out old unserviceable air release valve complete all as specified and directed. |
102 | M&L for lagging to 20/15 mm bore pipes used in external water supply or plumbing all round with 25 mm thick bonded mineral wool preformed "SNAPON" pipe sections of density 144 kg/cum conforming to IS 9842, provided with chicken mesh netting 25 gauge 20 mm mesh binding wire and reinforcement with plaster of paris complete all as specified and directed. |
103 | M&L for Cutting the road /hard standing to a size not exceeding 70 cm in width and not exceeding 90 cm in depth for laying / removal of MS/CI/GI pipe including making good so as to match with existing finishing with 100mm thick PCC (1:4:8) type D-2 (using 40mm grade crushed stone aggregate) on top including fair finishing with black paint complete all as specified and directed. |
104 | M&L for taking out water sample in clean container from borewell and Jhelum water and getting the same tested from the Govt approved laboratory for bacteriological and chemical test complete all as specified and directed. |
105 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of pipe line and getting out in hard/dense soil complete all as specified and directed. |
106 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in hard/dense soil complete all as specified and directed. |
107 | Removing excavated material in soils exc 500m but n.exc 1.0km and deposting where directed at a level n exc.1.5m above the starting point complete all as specified and directed. |
108 | S&F GI Elbow 15mm dia screwed both ends for iron pipe and fixed including taking down old unserviceable elbow complete all as specified and directed. |
109 | All as per Srl Item No. 56 here-in-before but20mm dia elbow complete all as specified and directed. |
110 | All as per Srl Item No. 56 here-in-before but25mm dia elbow complete all as specified and directed. |
111 | All as per Srl Item No. 56 here-in-before but40mm dia elbow complete all as specified and directed. |
112 | All as per Srl Item No. 56 here-in-before but50mm dia elbow complete all as specified and directed. |
113 | S&F GI Tee 15mm dia screwed both ends for iron pipe and fixed including taking down old unserviceable tee complete all as specified and directed. |
114 | All as per srl item No. 61 here-in-before but size of Tee 20mm dia complete all as specified and directed. |
115 | All as per srl item No. 61 here-in-before but size of Tee 25mm dia complete all as specified and directed. |
116 | All as per srl item No. 61 here-in-before but size of Tee 40mm dia complete all as specified and directed. |
117 | All as per srl item No. 61 here-in-before but size of Tee 50mm dia complete all as specified and directed. |
118 | All as per srl item No. 61 here-in-before but size of Tee 80mm dia complete all as specified and directed. |
119 | S&F GI Union 15mm dia screwed both ends for iron pipe and fixed including taking down old unserviceable union complete all as specified and directed. |
120 | All as per srl item No. 67 here-in-before but Union of size 20mm dia complete all as specified and directed. |
121 | All as per srl item No. 67 here-in-before but Union of size 25mm dia complete all as specified and directed. |
122 | All as per srl item No. 67 here-in-before but Union of size 40mm dia complete all as specified and directed. |
123 | All as per srl item No. 67 here-in-before but Union of size 50mm dia complete all as specified and directed. |
124 | All as per srl item No. 67 here-in-before but Union of size 80mm dia complete all as specified and directed. |
125 | S&F in repair GI Socket 15mm dia screwed both ends for iron pipe and fixed complete all as specified and directed. |
126 | All as per srl item No. 73 here-in-before but Socket of size 20mm dia complete all as specified and directed. |
127 | All as per srl item No. 73 here-in-before but Socket of size 25mm dia complete all as specified and directed. |
128 | All as per srl item No. 73 here-in-before but Socket of size 40mm dia complete all as specified and directed. |
129 | All as per srl item No. 73 here-in-before but Socket of size 50mm dia complete all as specified and directed. |
130 | All as per srl item No. 73 here-in-before but Socket of size 80mm dia complete all as specified and directed. |
131 | S&F in repair GI Nipple 15mm dia screwed both ends for iron pipe and fixed complete all as specified and directed. |
132 | All as per srl item No. 79 here-in-before but size of Nipple 20mm dia complete all as specified and directed. |
133 | All as per srl item No. 79 here-in-before but size of Nipple 25mm dia complete all as specified and directed. |
134 | All as per srl item No. 79 here-in-before but size of Nipple 40mm dia complete all as specified and directed. |
135 | All as per srl item No. 79 here-in-before but size of Nipple 50mm dia complete all as specified and directed. |
136 | S&F in repair GI Plug 15mm dia screwed both ends for iron pipe and fixed complete all as specified and directed. |
137 | All as per srl item No. 84 here-in-before but Plug of size 20mm dia complete all as specified and directed. |
138 | All as per srl item No. 84 here-in-before but Plug of size 25mm dia complete all as specified and directed. |
139 | S&F MS/ GI flange 80mm dia ISI marked including rubber washer and taking down old unserviceable GI flange complete all as specified and directed. |
140 | Supply and filling of lead wool, ISI marked complete all as specified and directed. |
141 | Supply and filling of pig lead, ISI marked complete all as specified and directed. |
142 | S&F in repair brass stop cock 15mm dia complete all as specified and directed. |
143 | S&F in repair Motor Protection relay, range 32-88 Amps type MPR 200nX including internal wiring complete all as specifed and directed. |
144 | S&F in repair Power contactor 3 pole, type-HGS 65, AC rating Range 32 to 65Amps including internal wiring complete all as specifed and directed. |
145 | S&F in repair Power contactor 3 pole, type-ML 4/6/12, AC3 rating 70 Amps including internal wiring complete all as specifed and directed. |
146 | Taking down unserviceable items from air compressor 10/12.5 HP and supply and fixingthe following spares complete all as specified and directed. |
147 | Piston ring |
148 | Piston |
149 | Connection rod |
150 | Main Bearing |
151 | Oil Pump |
152 | Discharge valve |
153 | Compressor belt |
154 | Supply and laying PVC insulated, PVC sheathed, Multistranded copper conductor 1100V, single core, 70sqmm complete including taking down unserviceable cable complete all as specified and directed. |
155 | Disconnecting the electrical connections of motor, water supply to the Pump andtaking out pump after disconnecting both motor and pump mechanically 40HP/30HP capacity installed at Pump Houses at BB Cantt and transporting the same to an authorized workshop for following repairs:- Dismantling the complete pump carefully, taking out all impellers, impeller housings, bush bearings, oil rings, shaft with keys, shaft sleeves with nuts, balancing valve, com seating bush, neck rings and bushes, coupling set, gland and gland packing, logging ring, oil filter plug, water thrower, suction and delivery covers etc all as directed by Engineer-in-Charge and recommended by the manufacturer.After repairs the pump set is to be brought back at Pump house and installed, coupled with motor.All electrical, water and mechanical connections to be re-done all as directed. Note: All spares to be replaced shall be measured and paid separately under respective items as supply only. |
156 | Bush bearing made out of bronze |
157 | Shaft sleeve with nuts made out of stainless steel 410 grade |
158 | Re-metaling of shaft by using brass material |
159 | Set of pins and Gaskets made out of Mild Steel |
160 | Coupling set made out of Cast Iron including bolts, nuts, washers & rubber bushes |
161 | Gland box made out of Cast Iron including gland box studs with nuts and washers |
162 | Eye of impeller |
163 | Metal (bronze) filling in the worn out portion of impellers, turning and grinding the metal filled portions, balancing the impeller by means of precision lathe machine |
164 | Disconnecting the electrical connections of motor, water supply to the Pump andtaking out pump after disconnecting both motor and pump mechanically 20HP/12.5HP capacity installed at Pump Houses at BB Cantt and transporting the same to an authorized workshop for following repairs:- Dismantling the complete pump carefully, taking out all impellers, impeller housings, bush bearings, oil rings, shaft with keys, shaft sleeves with nuts, balancing valve, com seating bush, neck rings and bushes, coupling set, gland and gland packing, logging ring, oil filter plug, water thrower, suction and delivery covers etc all as directed by Engineer-in-Charge and recommended by the manufacturer.After repairs the pump set is to be brought back at Pump house and installed, coupled with motor.All electrical, water and mechanical connections to be re-done all as directed. Note: All spares to be replaced shall be measured and paid separately under respective items as supply only. |
165 | Bush bearing made out of bronze |
166 | Shaft sleeve with nuts made out of stainless steel 410 grade |
167 | Re-metaling of shaft by using brass material |
168 | Set of pins and Gaskets made out of Mild Steel |
169 | Coupling set made out of Cast Iron including bolts, nuts, washers & rubber bushes |
170 | Gland box made out of Cast Iron including gland box studs with nuts and washers |
171 | Eye of impeller |
172 | Metal (bronze) filling in the worn out portion of impellers, turning and grinding the metal filled portions. Balancing the impeller by means of precision lathe machine |
173 | M&L for disconnecting the electrical and mechanical connections of motor, and taking out motor for rewinding of centrifugal pump set/non clogging sewage type submersible electric motor by taking out burnt copper winding from the electric motor and rewinding the motor with insulated copper wire as per exisitng gauge & turns including heat/fire proof sleeve, varnishing, heating complete and refixing the motor with existing position including testing and commissioning complete all as specified and directed for the following capacities of motors:- |
174 | 120 HP |
175 | 100 HP |
176 | 60 HP |
177 | 40 HP |
178 | 30 HP |
179 | 20 HP |
180 | 12.5 HP |
181 | 7.5 HP |
182 | 5 HP |
183 | S&F in repair MCCB 4 pole 415 V, adjustable type, 200 Amps with breaking capacity 36 KA all as specified and directed. |
184 | S&Fin repair of MCCB 4 pole 415 V, adjustable type, 400 Amps with breaking capacity 36 KA all as specified and directed. |
185 | S&F in repair of MCCB 4 pole 415 V, adjustable type, 630 Amps with breaking capacity 56 KA all as specified and directed. |
186 | Material and labour for Cleaning of RCC Over Head Reservoirs/UG & Semiunderground Sumps/Jack wells/Filter beds/clarifier for the following capacity as described below :- (a) Before start the cleaning of RCC Over Head Reservoirs/UG & SUG Sumps/Jack wells/Filter beds/clariflocculator are to be disconnected from all inlets/outlets of pipeline and plug with suitable fitting. After cleaning, plugedlineshould be washed out and connected to the all inlets/outlets of pipe line as per existing position. (b)The inner surface of the walls and ceiling of the tank shall be cleaned with high pressure jet pump after emptying the water in the tank (c)After thorough cleaning of the tank, the cleaning water and sludge is to be removed by using pump and the sludge has to be disposed off at a place as directed. (d)After removing the sludge from tank the tank shall be cleaned thoroughly by using high pressure water pump first and again the floor and inner surfaces of the tank shall be cleaned by using a industrial vaccum cleaner and the tank shall be made fully dirt free. (e)After made the tank dirt free, the inner surfaces of walls and ceiling of the tank shall be treated with anti bacterial agents. (f) After the treatment as mentioned at (e) above, the inner surfaces of walls and ceiling shall be treated with UV Radiator. (g) After complete treatment, writing of "Tank capacity" "Date of cleaning and due date of cleaning" on wall including applying two coats of white washing to external surfaces complete all as specified and directed. Semi underground drinking water sump 2 Lakhgallon capacity at Old BP Tank/Range road/New BP tank. |
187 | All as per srl item No.118 here-in-before but Clariflocculator plant 1.5 lakh gallon capacity at Batwara Water Point and R centre |
188 | All as per srl item No.118 here-in-before but Semi underground drinking water sump 75000 gallon capacity at Holiday home/Old BP tank/Chinar Mess/Arty Bde/ R centre |
189 | All as per srl item No.118 here-in-before but Semi underground drinking water sump 50000 galloncapacity at Batwara Water Point/R Centre |
190 | All as per srl item No 118 here-in-before but Overhead drinking water reservoir 50000gallon capacity at 216 Transit Camp Note for item srl No 118 to 122 :The unit rate quoted deemed to be included draining of water with mechanical equipment and working in water and mud etc. (ii) The rate quoted by contractor deemed to be included all safety precautions which shall be taken while working on RCC Over Head Reservoirs/UG & Semiunderground Sumps/Jack wells/Filter beds/clariflocculator plant and the contractor or his Engineer shall be available during execution of the job. (iii) Lighting arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted for that is deemed to be inclusive in the unit rate and electricity / diesel shall not be provided by the Department. (iv) Contractor will not be allowed more than one day to do the work inside the each tank to prevent interruption of water supply to the users. |
191 | S&F manually operated oil immersed star delta motor starter, 150 HP, three phase with double contact strip wound overload coil and cable entry box including taking down unserviceable starter complete all as specified and directed. |
192 | S&F manually operated oil immersed star delta motor starter, 100 HP, three phase with double contact strip wound overload coil and cable entry box including taking down unserviceable starter complete all as specified and directed. |