Tender For Construction Of Ladies Hostel At Cvas, Mannuthy-Electrification
Tender Value
7.79 Lakhs
Estimated cost
Bid Submission
12 Jan 2024
0 days left
EMD
19500
Bank guarantee accepted
Document Fee
1747
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
mannuthy → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Construction Of Ladies Hostel At Cvas, Mannuthy-Electrification
BOQ
| Sl. No. | Item Description |
| 1 | Power supply part |
| 2 | 90.1.1.1 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement,tying & fixing the conduit firmly with the re-inforcement etc. as required.20 mm |
| 3 | od344993/2022_2023 : Supplying and fixing of following ways surface/recess mounting vertical type,415 V Three phase, Energy meter box making material Polycarbonate (sintex Box) or metal (ABB, Indo asian or equivalent as per the PWD Approvals), vision panel, dust protected, box, common neutral link , 100A FN main switch, 63A porcelin fuse sets (3 Nos), etc complete (Provision for 3 phase energy meter of KSEB isincluded in the box).Approved quality and make as directed by the Engineer (Size-60x60x30cm) |
| 4 | 90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm |
| 5 | 9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) |
| 6 | od344758/2022_2023 : Supplying and Fitting wall /Floor mounting cubicle type panel board fabrication,conveyance, erection and commissioning of the same made with 16 gauge MS sheet, MS channels, MS flats of suitable sizes/gauge powder coated painting including all additional materials consist of INCOMER:1 set 125A, FP,36kA (D Sine)with Thermal - Magnetic Release MCCB, AC23, 415V, 50Hz, complete with handle assembly. BUS BARS: 1 Set of 125 Amp TPN bus bars of high conductivity electrolytic quality Aluminium alloy. INSTRUMENTS:1 No 3 phase Digital Multi function meter to read V, A, F with Acc class 1.1 Set of phase indicating lamps, LED type, RYB. 1 Set of 6A 10kA C curve SP control MCB & 1 Set of 125/5A, Class 5.0, 10VA, Cast Resin CT for metering OUTGOING: 63 A TP MCCB Thermal - Magnetic Release -3 No with ROM and Spreader, 32A TP MCCB Thermal - Magnetic Release -2 Nos With ROM and Spreader etc complete9Size of panel board-1x1x0.30 cm) |
| 7 | 90.1.1.2 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement,tying & fixing the conduit firmly with the re-inforcement etc. as required.25 mm |
| 8 | 90.11.1.21 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required12 way (8+36) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 9 | 90.11.1.10 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) |
| 10 | 90.11.1.11 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) |
| 11 | 2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door |
| 12 | 2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 13 | 2.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps |
| 14 | 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 15 | 2.14.3 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 16 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 17 | 2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 18 | 1.14.10 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 19 | Wiring |
| 20 | 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 21 | 1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 22 | 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 23 | 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 24 | 1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 25 | 1.23.5 : Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet |
| 26 | 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 27 | 1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module |
| 28 | 1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 29 | 1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 30 | 1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 31 | 1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B |
| 32 | 1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. |
| 33 | od344867/2022_2023 : Supply and fixing of approved quality and make20W LED Tube with fitting. Luker/Philips mushroom 20W all complete. |
| 34 | od345028/2022_2023 : Supply, conveyance, installation, testing and commissioningapproved quality and makeof ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep -1 star rated ceiling fan complete with 300 mm down rod , canopies, shackles and blades working on 230V/240V single phase A/C.(make :Usha/Havells/Crompton or equivalent) |
| 35 | 1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 36 | od345068/2022_2023 : Supply and fixing of 250 mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230V single phase A/C. (make :Usha/Havells/Crompton or equivalent) |
| 37 | od345029/2022_2023 : Supply and FixingLED Bulb classic 12W on existing batten holder- Luker/Philips/Bajaj/Syska |
| 38 | 1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 39 | od345677/2022_2023 : Supply and fixing of Elegant slim panel LED 18/20 W square / round fittings with all connected accessories- Open/recess,Luker/Philips/Polycab make |
| 40 | od345490/2022_2023 : Providing, Installation, testing and commissioning of street light 40/45 W LED<br>(Philips, Bajaj, Luker or Equivalent) |
| 41 | Earthing |
| 42 | 5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required |
| 43 | 90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
AI Tender Summary
Tender Timeline
Jan 05, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedJan 12, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 15, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender