Tender For Supply, Installation, Testing And Commissioning Of Air Handling Units Along With Accessories Under Buy-Back Arrangements At Rrcat, Indore., indore-Madhya Pradesh

Raja Ramana Centre For Advance Technology has published Tender For Supply, Installation, Testing And Commissioning Of Air Handling Units Along With Accessories Under Buy-Back Arrangements At Rrcat, Indore.. Submission Date for this Tender is 01-02-2024. Air Handling Unit Tenders in indore Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41477648
Corrigendum : Tender For Supply, Installation, Testing And Commissioning Of Air Handling Units Along With Accessories Under Buy-Back Arrangements At Rrcat, Indore.
Open Tender
Indian
Madhya Pradesh
indore
01-02-2024

Tender Details

Supply, Installation, Testing And Commissioning Of Air Handling Units Along With Accessories Under Buy-Back Arrangements At Rrcat, Indore.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Jan-2024 Updation in BOQ Excel Sheet BOQ 23-01-2024
2 17-Jan-2024 Pre bid Clarifications Other 23-01-2024
3 23-Jan-2024 Extension of Tender Dates Date 30-01-2024
4 30-Jan-2024 Extension of Tender Dates-2 Date 01-02-2024
5 30-Jan-2024 Pre Bid Clarifications Other 01-02-2024

Key Value

Document Fees
Refer document
EMD
INR 428000.0 /-
Tender Value
INR 2.14 Crore /-

BOQ Items

Name of Work: Supply, Installation, testing and commissioning of Air Handling Units along with accessories under buy-back arrangements at RRCAT, Indore.
Sl. No. Item Description
1Supply, installation, testing and commissioning (SITC) Air Handling Units (AHU)s with direct driven fan, electric motor, cooling coil, humidifier, Pre filters, volume control dampers, heaters, etc and other associated accessories as per Sr. no. 1 of technical specification.
2SITC of 35000 CFM AHU unit (minimum 85 TR) against dismantling and buyback of 2 old AHU units along with electrical panel having 15000CFM capacity.
3SITC of 15500 CFM AHU unit (minimum 36 TR) against dismantling and buyback of 1 old AHU unit along with electrical panel having 15000 CFM capacity.
4SITC of 9,200 CFM AHU unit (minimum 22 TR) against dismantling and buyback of 1 old AHU unit along with electrical panel having 8000CFM capacity.
5SITC 13,000 CFM AHU unit (minimum 32 TR) against dismantling and buyback of 1 old AHU unit along with electrical panel having 11000CFM capacity.
6Supply and installation of motorised fire cum smoke control damper complete with fire & smoke sensors, actuator, control panel and other accessories as per item no. 2 oftechnical specification.
7Supply, fabrication, installation, testing and commissioning of GI ducts fabricated as per Item No. 3 of technical specification. The ducting shall be complete with bends, elbows, turning vanes (if required), reducers/transition pieces, MS flanged joints, 6 mm thick neoprene gasket, SS hardware, silicon sealant etc. as per site requirment to interconnect the machine (AHU etc) with existing duct system of Lab.
8Supply and installation of 19 mm (min.) thick closed cell class "0" zero nitrile rubber insulation with 0.5 mm thick aluminium claddingcomplete with other accessories such as adhesive, jointing tap, SS/GI hardware etc. as per item no. 04 of technical specification.
9Supply and installation of Acoustic insulation suitable as per Item no. 5 of technical specification
10Supply, installation, testing and commissioning ofMS pipe of following sizes & thickness / class for chilled water system complete with all required flanges, fittings, gaskets, fasteners, Nitrile rubberinsulation covered with Aluminium Cladding etc. as per Item no. 6 of technical specification.
11NB 50 mm
12NB 65 mm
13NB 80 mm
14NB 100 mm
15Supply, installation, testing and commissioning of flanged end, non rising spindle, PN-16, CI gate valves of following sizes for chilled water system complete with all required counter flanges, fittings, gaskets, fasteners, nitrile rubber insulation covered with aluminium cladding etc. as per Item no. 7 of technical specification.
16CI Gate Valve size 50mm
17CI Gate Valve size 65mm
18CI Gate Valve size 80mm
19CI Gate Valve size 100mm
20Supply, installation, testing and commissioning of flanged end, PN-16, CI balancing valves of following sizes for chilled water system complete with all required counter flanges, fittings, gaskets, fasteners, nitrile rubber insulation covered with aluminium cladding etc. as per Item no. 08 of technical specification.
21CI Globe/Balancing valves size 50mm
22CI Globe/Balancing valves size 65mm
23CI Globe/Balancing valves size 80mm
24CI Globe/Balancing valves size 100mm
25Supply, installation, testing and commissioning of flanged end, PN-16, CI Y-strainers of following sizes for chilled water system complete with all required counter flanges, fittings, gaskets, fasteners, nitrile rubberinsulation covered with aluminium cladding etc. as per Item no. 09 of technical specification.
26CI Y-strainers size 50mm
27CI Y-strainers size 65mm
28CI Y-strainers size 80mm
29CI Y-strainers size 100mm
30Supply, installation, testing and commissioning of PN-16,2-way modulating with energy saving features. The valves shall be of following sizes for chilled water system complete with BMS compatibility and all required counter flanges and/ fittings, gaskets, fasteners, nitrile rubberinsulation covered with aluminium cladding etc. as per Item no. 10 of technical specification.
312-way modulating energy valves size 50 mm
322-way modulating energy valves size 65 mm
332-way modulatingenergy valves size 100 mm
34Supply, installation, testing and commissioning of flangless, PN 16 Butterfly valves of following sizes for chilled water system complete with all required nipples, fittings, nitrile rubberinsulation covered with aluminium cladding etc. as per Item no. 11 of technical specification.
35Butterfly valves size 50mm
36Butterfly valves size 65mm
37Butterfly valves size 80mm
38Butterfly valves size 100mm
39Supply, installation, testing and commissioning of threaded end, PN 16/class-150 CI auto air vent having SS ball of 25 mm dia suitable for chilled water system complete with all required nipples, fittings, nitrile rubberinsulation covered with aluminium cladding etc. as per Item no. 12 of technical specification
40Supply, fabrication, installation and painting of MS structure to support pipes, valves, flanges etc. required at site as per Item no. 13 of technical specification.
41Fabrication, Supply and installation of 3mm thick AISI 304 Stainless Steel tray to support total base of AHU as per technical specification Item No. 14
42Supply, installation, testing and commissioning offollowing BMS compatible instruments for measurement and control of various parameters as per Item no. 15 of technical specification.
43Humidistat with sensors for measuring & control of relative humidity and suitable for on-off operation of heaters of AHUs.
44Airstat/air flow switch suitable for on-off operation of heaters of AHUs.
450 to 50 deg C range stem type thermometers having 100 mm dia dial with suitable stainless steel thermo wells for measurement of water temperature.
460 to 10 kg/sq. cm. range bourden tube type pressure gauge having 100 mm dia dial, U syphon and cockin stainless steel construction for measurement of water pressure.
47Differential Pressure Switch / Sensor Transmitter
48Temperature, RH and dew point meter at the outlet of AHU
49Air flow sensor with transmiter for AHU
50Controller: Supply, installation, testing and commissioning of standalone BACnet/IP based modular type, BMS compatible DDC controller / automation station having integral web browser, I/O module, flash memory for programmed logic storage communication ports (RS 485, Ethernet RJ 45, and USB/additional ethernet), etc. For Air Handling Unit (AHU) control, monitoring, status indication, data logging etc as per tender technical specification.
51Temerature sensor and transmitter: Supply, installation, testing and commissioning of high accuracy (±0.03 deg.C @ 0 deg.C or better for the span of 0-35 deg. C) BMS compatible temperature sensor (1000 ohm platinum RTD type) and transmitter unit with associated cabling as per tender technical specifictions.
52Relative humidity sensor and transmitter: Supply, installation, testing and commissioning of high accuracy (±1% or better for the span of 30% to 70%) Relative Humidity (RH) sensor and transmitter unit with associated cabling as per tender technical specifications.
53Immersion type temperature sensors set: Supply, installation, testing and commissioning of BMS compatible immersion temperature sensor one (01) in supply and one (01) in return chilled water line ( 50/65/80 /100mm dia. MS) in AHUs as per technical specifications.
54Smoke detectors set: Supply, installation, testing and commissioning of BMS compatible photoelectric type smoke detectors set suitable for HVAC duct mounting. A set shall include two numbers of smoke detectors, associated cabling, mounting arrangements, etc. as per the technical specifications
55Development of BMS and integration with existing BMS: Development of building monitoring system (BMS) for all the AHUs s and integrating the BMS with the existing Siemens" make Desigo CC BMS installed at server grade computer (HMI station) as per technical specifications.
56Electrical Panels : Design Fabrication, supply, installation, testing & commissioning of ,min IP-42 MCC switchboards with the following components suitable for use at 415 V, 3 phase 4 wire 50 Hz system, and suitable for a fault level of 50 KA symmetrical at 415 V complete as per Drawings, detailed specifications, instructions & approval of EIC and having following configurations: Note:- 1) VFD shall be BMS compatible & shall comply with the latest edition ofIEC 61800-3 & IEC 61000 standards 2) Electrical Panel shall have required no. of VFD feeders in line with the AHU design being offered.
57Electrical Panel -1Incomer: 400A FP MCCB (Ics=50 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG). Main Bus bar - 1 Set 400 A TPN tinned copper bus bar having maximum current density of 1.6A/sq.mm to withstand symmetrical fault level of 50 KA at 415 V. Outgoing: 1) MCB feeders for heaters/preheaters/humidifier: 4P MCB D curve with power contactor suitable for as per the current rating of re-heater/preheater/humidifier,alongwithinterlocking with signal /communication wire as per recommendation of OEM/EIC & complete with all accessories and internal wiring required for automatic & manual operation, etc. complete as required and as per tender specifications. - 04 set. 2) VFD feeders with DOL bypass : TP MCCB (Ics=50 kA, microprocessor trip release for O/L&S/C&E/F protection (LSIG)fedVFD drives suitable to run 35,000CFM AHUAlong with Interlocking with signal /communication wire as per recommendation of OEM/EIC & complete with all accessories and internal wiring required for automatic & manual operation, etc. complete as required and as per tender specifications required for 350000 CFM AHU. 3) Spare feeders:- • 63 A C-Curve TPN MCB with ON/OFF LED indicating lamp with 6A control SP MCB-2 sets. • 32 A C-Curve TPN with ON/OFF LED indicating lamp with 6A control SP MCB- 1sets.
58Electrical Panel -2 Incomer:250A FP MCCB (Ics=50 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG) Main Bus bar - 1 Set 250 A TPN tinned copper bus bar having maximum current density of 1.6A/sq.mm to withstand symmetrical fault level of 50 KA at 415 V. Outgoing: 1) MCB feeders for heaters/preheaters/humidifier: 4P MCB D curve with power contactor suitable for as per the current rating of re-heater/preheater/humidifier, alongwithinterlocking with signal /communication wire as per recommendation of OEM/EIC & complete with all accessories and internal wiring required for automatic & manual operation, etc. complete as required and as per tender specifications. - 04 set. 2) VFD feeder with DOL bypass : TP MCCB (Ics=50 kA, microprocessor trip release for O/L&S/C&E/F protection (LSIG) fedVFD drive suitable to run 15,500CFM AHU Along with Interlocking with signal /communication wire as per recommendation of OEM/EIC & complete with all accessories and internal wiring required for automatic & manual operation, etc. complete as required and as per tender specifications 3) Spare feeders:- • 63 A C-Curve TPN MCB with ON/OFF LED indicating lamp with 6A control SP MCB-1 sets. • 32 A C-Curve TPN with ON/OFF LED indicating lamp with 6A control SP MCB- 1 sets.
59Electrical Panel -3Incomer: 125A FP MCCB (Ics=50 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG) Main Bus bar - 1 Set 125 A TPN tinned copper bus bar having maximum current density of 1.6A/sq.mm to withstand symmetrical fault level of 50 KA at 415 V. Outgoing: 1) MCB feeders for heaters/preheaters/humidifier: 4P MCB D curve with power contactor suitable for as per the current rating of re-heater/preheater/humidifier, interlocking with signal /communication wire as per recommendation of OEM/EIC & complete with all accessories and internal wiring required for automatic & manual operation, etc. complete as required and as per tender specifications. - 04 set. 2) VFD feeder with DOL bypass : TP MCCB (Ics=50 kA, microprocessor trip release for O/L&S/C&E/F protection (LSIG) fedVFD drive suitable to run 13,000CFM AHU Along with Interlocking with signal /communication wire as per recommendation of OEM/EIC & complete with all accessories and internal wiring required for automatic & manual operation, etc. complete as required and as per tender specifications- 3) Spare feeders:- • 32 A C-Curve TPN with ON/OFF LED indicating lamp with 6A control SP MCB- 1 sets.
60Electrical Panel -4 Incomer: 125A FP MCCB (Ics=50 kA) with Microprocessor trip release for O/L & S/C & E/F protection (LSIG) Main Bus bar - 1 Set 125 A TPN tinned copper bus bar having maximum current density of 1.6A/sq.mm to withstand symmetrical fault level of 50 KA at 415 V. Outgoing: 1) MCB feeders for heaters/preheaters/humidifier: 4P MCB D curve with power contactor suitable for as per the current rating of re-heater/preheater/humidifier, interlocking with signal /communication wire as per recommendation of OEM/EIC & complete with all accessories and internal wiring required for automatic & manual operation, etc. complete as required and as per tender specifications. - 04 set. 2) VFD feeder with DOL bypass : TP MCCB (Ics=50 kA, microprocessor trip release for O/L&S/C&E/F protection (LSIG)fedVFD drive suitable to run 9,200CFM AHUAlong with Interlocking with signal /communication wire as per recommendation of OEM/EIC & complete with all accessories and internal wiring required for automatic & manual operation, etc. complete as required and as per tender specifications. 3) Spare feeders:- • 32 A C-Curve TPN MCB with ON/OFF LED indicating lamp with 6A control SP MCB-2 sets.
61Supply, installation, testing & commissioning of1.1 KV copper multi stranded conductor with XLPE insulation, extruded PVC inner sheathed, G.I flat steel strip armoured, extruded PVC outer sheathed FRLS cable conforming to IS 7098 Part-I with latest amendments, fixed on wall/column/slab/ Cable tray/trench/ shaft/pit/ on 5mm thick G.I. flat/angle support fixed with coach screws/grouted in wall/anchor fasteners, 2mm. thick G.I. fabricated saddle, all fixing accessories providing brass cable number tag & as pertechnical specifications & as per instructions of the E-I-C. & of the following sizes.
624 Cx10 sq. mm Armoured power Cable
634Cx16 sq. mm Armoured power Cable
64Supply, Installation, Testing & Commissioning of Heavy duty Double compression end termination for following LT, XLPE insulated power cable using Brass gland, tinned Copper lugs suitable for crimping, end boxcomplete as required and as per tender specifications and as per of technical specification.
654 Cx10 sq. mm Armoured power Cable
664Cx16 sq. mm Armoured power Cable
67Only Installation, Testing and Commisioning of 1100 V voltage grade Aluminium XLPE insulated, Armoured, FRLS PVC sheathed power cable on wall/trench by supply and fixing of clamps and other required hardware.
683.5 C X 400/240/150/120 sq. mm. cable
693.5 C X 70/50 sq. mm. cable
70End termination of 1100 volt voltage grade Aluminium Armoured XLPE/PVC power cable by using double compression Nickel Plated Brass Gland, Aluminium Small/Medium/Long barrel Lug and earth clamps duly connected to the equipment ground through GI/Copper Conductor. This includes Supply of end jointing materials with all accessories.
713.5 C X 240/150 sq. mm.
723.5 C X 120/95/70/50 sq. mm.
73Dismantling and stacking of existing L.T having following size including removal of switchgears, Cu/Al Bus bar, end termination of Power cables etc. and safe storing within the 2.5 km radius with suitable vehicle.
74Size of panel > (1.1 X 1.1 X 0.3) to <( 2.0 X2.0 X 0.4) mtr.
75Removing of following 1100 V voltage grade Aluminium PVC/XLPE insulated, Armoured, PVC sheathed electrical power cables already installed in L.T panels including disconnection of end termination from old panel, from wall & trench & safe storing within the 2.5 km radius with suitable vehicle.
763.5 C X 400/240/150/120 sq. mm. cable
773.5 C X 70/50/35/25 or 4 C X 25/16/10/6 sq. mm. cable
78Supply & Installation of stuctural steel work including supply, cutting, fabricating, welding, necessory scaffolding erecting & fixing in position, including painting with a primer coat of approved steel primer & black steel paint.
79Fabrication, Supply & Installation of wire mesh cable tray :- Electro zinc plated carbon steel wire mesh cable tray300 mm width and size height of 105 mm,including their standard mounting supports/brackets, clamps, connectors, hardware etc. all as per instruction of EIC and detail technical specifications.
80Supply and installation of G. I. strip/wire of required size under ground at a depth of 600 mm from FGL including excavation, black bitumin painting, backfilling and consolidation of soil. Installtion along cable trays / walls using G. I. clamps/Saddle & spacer at interval of 500 mm / as per site requirements including required hardware.
81Supply and laying GI earthing strip / wire with accessories in cable tray / wall.