Uttarakhand Power Corporation Limited-UPCL has published Tender For Maintenance Of Underground System. Submission Date for this Tender is 17-01-2024. Road Work Tenders in urban Uttarakhand. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | 1.1KV LT armoured PowerCable 3.5x150sqmm |
2 | LT SERVICE CABLE FROM DB TO METER: 1.1KV LT XLPE Cable 3.5x70sqmm |
3 | LT SERVICE CABLE FROM DB TO METER: 1.1KV LT XLPE Cable 4x25sqmm |
4 | LT SERVICE CABLE FROM DB TO METER: 1.1KV LT PVC Cable 4x16sqmm |
5 | LT SERVICE CABLE FROM DB TO METER: 1.1KV LT PVC Cable 4x10sqmm |
6 | 1.1KV LT armoured PowerCable 2x10sqmm |
7 | Supply of LT cable heavy duty double compression termination Brass Glands and long barrel heavy duty AL Lugs suitable for the following cable sizes: |
8 | Supply of LT cable heavy duty double compression termination Brass Glands |
9 | Brass Gland for 1.1KV LT XLPE Cable 3.5x400sqmm |
10 | Brass Gland for 1.1KV LT XLPE Cable 3.5x240sqmm |
11 | Brass Gland for 1.1KV LT XLPE Cable 3.5x150sqmm |
12 | 1.1KV LT XLPE Cable 4x25sqmm |
13 | 1.1KV LT XLPE Cable 4x10sqmm |
14 | 1.1KV LT XLPE Cable2x10sqmm |
15 | 1.1KV LT XLPE Cable2x6sqmm |
16 | Supply of LT long barrel heavy duty AL Lugs suitable for the following cable sizes: |
17 | AL LUGfor 1.1KV LT XLPE Cable 3.5x400sqmm |
18 | AL LUG for 1.1KV LT XLPE Cable 3.5x240sqmm |
19 | AL LUG for 1.1KV LT XLPE Cable 3.5x150sqmm |
20 | 1.1KV LT XLPE Cable 4x25sqmm |
21 | 1.1KV LT XLPE Cable 4x10sqmm |
22 | 1.1KV LT XLPE Cable2x10sqmm |
23 | 1.1KV LT XLPE Cable2x6sqmm |
24 | Supply of Smart Street Light Management System with box, 10-60 Amp. as per specifications complete set |
25 | STREET LIGHT MANAGEMENT TIMER switch along with energy meter as per already approved GTP |
26 | MCB 63 AMP FOR STREET LIGHT MANAGEMENT BOX double pole Havells or above quality |
27 | Supply of 33 KV Ring Type Metering CT 600-300/1, Cl0.5 for 33 KV RMU |
28 | Supply of 33 KV Ring Type Protection CT 600-300/1, 5P10 for 33 KV RMU |
29 | Supply of 33 KV PT 33KV/110VOLTfor 33 KV RMU |
30 | Supply of 11 KV Ring Type Metering CT 400-200-100/1,Cl 0.5 for 11 KV RMU |
31 | Supply of 11 KV Ring Type Protection CT 400-200-100/1,5P10 for 11 KV RMU |
32 | Supply of 11 KV PT 11KV/110VOLT FOR 11 KV RMU |
33 | Supply of Air Circuit Breaker, 50 KA, 4 Pole Fixed Manual Type, Microprocessor based LSIG Release with O/c, E/f & S/c protection-2000 Ampere (ABB) as per approved GTP For CSS |
34 | Supply of MCCB, 4P 50 KA fixed manual type microprocessor based release with O/c, E/f & S/c protection-400 Ampere (ABB) as per approved GTP For CSS |
35 | Supply of MCCB, 4P 50 KA microprocessor based LSIG release with O/c, E/f & S/c protection-250 Ampere (L&T, Havells,ABB) as per incoming in LT Distribution Box |
36 | Supply of 400Amps TP MCCB 50kA TM Based O/C, S/C Release for Incoming & outgoing (L&T, Havells, ABB) |
37 | Supply of 100Amps TP MCCB 50kA TM Based O/C, S/C Release for outgoing (L&T, Havells, ABB) |
38 | Supply of 63 Amps TP MCCB 50kA TM Based O/C, S/C Release for outgoing (L&T, Havells, ABB) |
39 | Supply of series trip,self-powered microprocessor based numerical over current relay (IDMTL + Inst.). O/C for CSS(Ashida Make) |
40 | Supply, ofAL Bus bar of L.T C PannelOf size50x5mmfor 3Phase + N, Off standard size. |
41 | Supply of HT cable termination Kits / Straight through |
42 | 33 KV (E) XLPE HT cable J/KTYPE 3 x 400 sq.mm(O/D) Type (make RAYCHEM 3M) |
43 | 33KV (E) XLPE HT cable 3x400sqmm (Straight thro) (make RAYCHEM 3M) |
44 | 33kV Touch proof termination kits 3X400Sq MM(I/D)Type (suitable for 33kV (RMU) (make RAYCHEM 3M) |
45 | 33 KV (E) XLPE HT cable J/K 1 x 630 sq.mm (Outdoor)(make RAYCHEM 3M) |
46 | 33KV (E) XLPE HT cable j/k1x630sqmm (Straight thro) (Make RAYCHEM/3M)) |
47 | 33kV Touch proof termination Indoor kits 1X630Sq MM (suitable for 33kV(RMU)( RAYCHEM /3M) |
48 | 11KV (E) XLPE HT Cable J/K3x300sqmm (Indoor)( RAYCHEM 3M) |
49 | 11KV (E) XLPE HT Cable j/k3x300sqmm (Outdoor) ( RAYCHEM 3M) |
50 | 11KV (E) XLPE HT Cable J/K3x300sqmm (Straight thro)( RAYCHEM 3M)) |
51 | Supply of LT cable termination Kits / Straight through |
52 | Heat shrinkable 1.1KV XLPEStraight though J/Kit size of 3.5x400sqmm |
53 | Heat shrinkable 1.1KV XLPEStraight though J/Kit size of 3.5x240sqmm |
54 | Heat shrinkable 1.1KV XLPEStraight though J/Kit size of 3.5x150sqmm |
55 | Heat shrinkable 1.1KV XLPEStraight though J/Kit size of 3.5x70sqmm |
56 | Heat shrinkable 1.1KV XLPEStraight though J/Kit size of 3.5x50sqmm |
57 | 1.1 KV cable Kit size for cable of size 4x16sqmm,4X10 SQMM/2X10SQ MM/2X6SQ MM complete set including mastic tape complete |
58 | Supply of HDPE PIPEfor laying 11KV & L.T cable |
59 | (A) 100MM |
60 | (B) 75 MM |
61 | (C) 50MM |
62 | Supply of LT C Pannel |
63 | T-Connector for 11 KV D/P |
64 | Mastic Tape |
65 | FLR |
66 | WRSM Recron Sheet for covering minor cuts in cable |
67 | Supply of insulator for C Pannel bus bar |
68 | Total (A) |
69 | ERECTION WORK |
70 | Routine Maintenance, Preventive maintenance of complete Network which includes routine inspection of all equipments (with thermovision camera where ever applicable), all kinds of panels, transformers, all types of overhead structures, tightening of Joints/Lugs, Cable health monitoring,maintaining record/ log book/photos. As per direction & shedule provided by officer in charge. |
71 | (A):-Digging of pit for replacement of damage 33 kvkit/straight thruoght& removed old existing damage j/k |
72 | (B):-Digging of pit for replacement of damage 11 kv kit/straight thruoght& removed old existing damage j/k |
73 | (C):-Digging of pit for replacement of damage 0.4kvkit/straight thruoght& removed old existing damage j/k with supply |
74 | (A):-.back fillingof pit by earth &stone after filling of straight through of (33kv and repairing of road inclusing cost of cement,sand & stone |
75 | (B):-.back fillingof pit by earth &stone after filling of straight through of (11kvand repairing of road inclusing cost of cement,sand & stone |
76 | (C):-.back fillingof pit by earth &stone after filling of straight through of (LT) and repairing of road inclusing cost of cement,sand & stone |
77 | C-CONSUMER S/C |
78 | (a):-Digging of pit for damage Consumer s/c |
79 | (b) jointing of damage consumer,s cable (Including jointing material) |
80 | (c):-.back filligof pit after jointing/fixing of consumerservice cableand repairing of road inclusing cost of cement,sand & stone |
81 | Under grounding of all 33 KV lines and other related works under the project area |
82 | Jointing/replacement of damage or burnt/Laying of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments through manual HDD which is as good as open excavation. |
83 | 33KV (E) XLPE HT cable 3x400sqmm |
84 | Replacement of damage or burnt/Laying of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments through manual HDD which is as good as open excavation. |
85 | 11KV (E) XLPE HT Cable 3x300sqmm |
86 | Erection, testing, replacement of damage or burnt and commissioning of HT cable termination Kits / Straight through |
87 | 33 KV (E) XLPE HT cable 3 x 400 sq.mm (Outdoor) after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work |
88 | 33 KV (E) XLPE HT cable 1 x 630 sq.mm (Outdoor) after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work including |
89 | 11KV (E) XLPE HT Cable 3x300sqmm (Outdoor) after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work including |
90 | 33kV Touch proof termination kits 3X400Sq MM (suitable for 33kV (RMU) on switchgears after carefully removing the insulation of the cable,duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs, |
91 | 33kV Touch proof termination kits 1X630Sq MM (suitable for 33kV (RMU) on switchgears after carefully removing the insulation of the cable,duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs,duly plumbing |
92 | 11KV (E) XLPE HT Cable 3x300sqmm (Indoor) on switchgears after carefully removing the insulation of the cable,duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs,duly plumbing. |
93 | 33KV (E) XLPE HT cable 3x400sqmm (Straight thro)after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work |
94 | 33KV (E) XLPE HT cable 1x630sqmm (Straight thro) after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work |
95 | 11KV (E) XLPE HT Cable 3x300sqmm (Straight thro) after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work |
96 | Repairing of 33/11 KV RMU Door with locking arrangement & gasket/rubber around the panel door.with Tightness ofIndoor Joints in 33 KV/11 RMU & CSS with washers |
97 | Replacement of phase indicators,with supply |
98 | Replacement of phase sensors with supply |
99 | Rewiring/repairing of internal connection in 33/11 KV RMU & CSS for any malfunctioning(supply Wire & Lugs ) |
100 | Refilling of SF6 Ges in 33/11 / CSS RMU includinmgSF6 ges Supply |
101 | replacement/Errection of damaged motor for spring Charging for 33/11 KV RMU including supply and fixing ABB Make |
102 | EL Machanisam for RMU Brakerincluding supply andfixing ABB Make |
103 | 33 KV RMU Bushing (3 No.)including supply andfixing ABB Make |
104 | 11 KV RMU Bushing (3 No.)including supply andfixing ABB Make |
105 | Tripping Coil 24 V Dc including supply andfixing ABB Make |
106 | closing Coil 24 V Dc including supply andfixing ABB Make |
107 | Erection, testing and commissioning/replacement of damage or burnt of 33/11 KV Ring Type Metering/Protection CT for RMU"s |
108 | Erection, testing and commissioning/replacement of damage or burnt of 33/11 KV PT for RMU"s |
109 | EARTHING FOR DTR , RMU, CSS AND LT FEEDER PANELS |
110 | Installation/replacement of Chemical earthing station as per IS 3043 complete with GI earthing electrode ,Bentonite, . Conductor upto test link, test link,earthing chamber, 450x450 mm C.I. Manhole chamber etc. |
111 | Replacement of damage or burnt/Laying of Al conductor PVC insulated1.1 KV grade armoured LT power cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments through manual HDD which is as good as open excavation. |
112 | 1.1KV LT armoured PowerCable 3.5x400sqmm |
113 | 1.1KV LT armoured PowerCable 3.5x240sqmm |
114 | 1.1KV LT armoured PowerCable 3.5x150sqmm |
115 | LT SERVICE CABLE FROM DB TO METER: 1.1KV LT XLPE Cable 3.5x70sqmm |
116 | LT SERVICE CABLE FROM DB TO METER: 1.1KV LT XLPE Cable 4x25sqmm |
117 | LT SERVICE CABLE FROM DB TO METER: 1.1KV LT PVC Cable 4x16sqmm |
118 | LT SERVICE CABLE FROM DB TO METER: 1.1KV LT PVC Cable 4x10sqmm |
119 | LT SERVICE CABLE FROM DB TO METER: 1.1KV LT PVC Cable 2x6sqmm |
120 | 1.1KV LT armoured PowerCable 2x10sqmm |
121 | Erection, testing and commissioning/replacement of damage or burnt LT cable heavy duty double compression termination Brass Glands |
122 | Brass Gland for 1.1KV LT XLPE Cable 3.5x400sqmm |
123 | Brass Gland for 1.1KV LT XLPE Cable 3.5x240sqmm |
124 | Brass Gland for 1.1KV LT XLPE Cable 3.5x150sqmm |
125 | 1.1KV LT XLPE Cable 4x25sqmm |
126 | 1.1KV LT XLPE Cable 4x10sqmm |
127 | 1.1KV LT XLPE Cable2x10sqmm |
128 | 1.1KV LT XLPE Cable2x6sqmm |
129 | Errection of LT long barrel heavy duty AL Lugs suitable for the following cable sizes: |
130 | AL LUGfor 1.1KV LT XLPE Cable 3.5x400sqmm |
131 | AL LUGfor 1.1KV LT XLPE Cable 3.5x240sqmm |
132 | AL LUG for 1.1KV LT XLPE Cable 3.5x150sqmm |
133 | 1.1KV LT XLPE Cable 4x25sqmm |
134 | 1.1KV LT XLPE Cable 4x10sqmm |
135 | 1.1KV LT XLPE Cable2x10sqmm |
136 | 1.1KV LT XLPE Cable2x6sqmm |
137 | Replacement of Door with Hinges & Locking arrangement in LT C Type Distribution Boxes With supply |
138 | Erection, testing and commissioning/replacement of damage or burnt Smart Street Light Management System with box, 10-60 Amp. as per specifications |
139 | Erection, testing and commissioning of Air Circuit Breaker, 65 KA, 4 Pole Fixed Manual Type, Microprocessor based LSIG Release with O/c, E/f & S/c protection-2000 Ampere (ABB) as per approved GTP For CSS |
140 | Erection, testing and commissioning of MCCB, 4P 36 KA fixed manual type microprocessor based release with O/c, E/f & S/c protection-400 Ampere (ABB) as per approved GTP For CSS |
141 | Erection, testing and commissioning of MCCB, 4P 50 KA microprocessor based LSIG release with O/c, E/f & S/c protection-250 Ampere (L&T, Havells,ABB) as per approved GTP For incoming in LT Distribution Box |
142 | Erection, testing and commissioning of 400Amps TP MCCB 50kA TM Based O/C, S/C Release for Incoming & outgoing (L&T, Havells, ABB) as per approvedGTP |
143 | Erection, testing and commissioning of 100Amps TP MCCB 50kA TM Based O/C, S/C Release for outgoing (L&T, Havells, ABB) as per approvedGTP |
144 | Erection, testing and commissioning of 63 Amps TP MCCB 50kA TM Based O/C, S/C Release for outgoing (L&T, Havells, ABB) as per approvedGTP |
145 | Erection, testing and commissioningseries trip,self-powered microprocessor based numerical over current relay (IDMTL + Inst.). O/C for CSS(Ashida Make) as per Approved GTP |
146 | Checking of Earth Strip with Welding joints are smooth painted with Anti corrosion paint or checking of suitable size nuts & washer used |
147 | Replacement of damage busbar of c pannelincluding disconnection/reconnection ofassociated consumer |
148 | Repairing of existing damagefencing |
149 | Reparing of damageEquipmentplinth including material |
150 | Erection and Filling of LT J/Kit |
151 | Erection and FillingHeat shrinkable 1.1KV XLPEStraight though J/Kit size of 3.5x400sqmm |
152 | Erection and Filling Heat shrinkable 1.1KV XLPEStraight though J/Kit size of 3.5x240sqmm |
153 | Erection and Filling Heat shrinkable 1.1KV XLPEStraight though J/Kit size of 3.5x150sqmm |
154 | Erection and Filling Heat shrinkable 1.1KV XLPEStraight though J/Kit size of 3.5x70sqmm |
155 | Erection and Filling Heat shrinkable 1.1KV XLPEStraight though J/Kit size of 3.5x50sqmm |
156 | 1.1 KV cable Kit size for cable of size 4x16sqmm,4X10 SQMM/2X10SQ MM/2X6SQ MM complete set including mastic tape complete |
157 | Laying of HDPE PIPEfor laying 11KV & L.T cable |
158 | (A) 100MM |
159 | (B) 75 MM |
160 | (C) 50MM |
161 | Erection of LT C Pannel |
162 | Fixing of T-Connector for 11 KV D/P |
163 | Errection of insulator for C Pannel bus bar |
164 | Total (B) |
165 | Total (A+B) |
166 | Company/Firm Name |
167 | Name |
168 | Designation |
169 | Date |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy