Tender For Repair/Maintenance Of External Lt Distribution Network System Over Head Line Lt Ug Cable ,Lt Panel ,Apfc Panels, Periodica Works And Allied Works For Sector-I To Iv At Age Charduar Area Under Ge (North) Tezpur, tezpur-Assam

Military Engineer Services-MES has published Tender For Repair/Maintenance Of External Lt Distribution Network System Over Head Line Lt Ug Cable ,Lt Panel ,Apfc Panels, Periodica Works And Allied Works For Sector-I To Iv At Age Charduar Area Under Ge (North) Tezpur. Submission Date for this Tender is 20-01-2024. Electrical Panel Tenders in tezpur Assam. Bidders can get complete Tender details and download the document.




Tender Notice

41443160
Tender For Repair/Maintenance Of External Lt Distribution Network System Over Head Line Lt Ug Cable ,Lt Panel ,Apfc Panels, Periodica Works And Allied Works For Sector-I To Iv At Age Charduar Area Under Ge (North) Tezpur
Open Tender
Indian
Assam
tezpur
20-01-2024

Tender Details

Repair / Maintenance Of External Lt Distribution Network System Over Head Line Lt Ug Cable , Lt Panel , Apfc Panels, Periodica Works And Allied Works For Sector-I To Iv At Age Charduar Area Under Ge ( North ) Tezpur

Key Value

Document Fees
INR 500 /-
EMD
INR 96000.0 /-
Tender Value
INR 48 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINTENANCE OF EXTERNAL LT DISTRIBUTION NETWORK SYSTEM OVER HEAD LINE LT UG CABLE ,LT PANEL ,APFC PANELS, PERIODICA WORKS AND ALLIED WORKS FOR SECTOR-I TO IV AT AGE CHARDUAR AREA UNDER GE (NORTH) TEZPUR
Sl. No. Item Description
1M&L for detecting faults in distribution system over head line/under ground cable of any type/size at any location under AGE Charduar on daily basis and rectifying the fault to restore the electric supply in all respect within stipulated time. Note :- (i). Work shall be executed in various areas under AGE Charduar i.e. Sonaipam,Thakurbari,Phulbari,Amaribari and Charduar, Bhalukpong area. (ii). The above work shall be carried out on daily basis on complaints received in MES service centre and electrician shall report to complaint cell to colllect the complaints from concern person. (iii). The above work shall be carried out on daily basis on complaints received in MES service centre and electrician shall report to complaint cell to colllect the complaints from concern person. (iv). Any major spare required to restore the elctric supply or to make the system functional shall be measure separately under repective items. (v). Contractor shall bound to clear the fault on same day. (vi). The contractor or his rep shall reach at the site of breakdown within one hour of notification of breakdown on telephone/email.In case the rep of contractor or contractor himself fails to reach at site of breakdown and not starts rectifying the fault ot attends breakdown within one hour,penalty of Rs 1500/- per hour per breakdown shall be imposed on this account. (vii). The contractor or his authorized representative shall be solely responsible to take shut down of any feeder of any voltage under AGE Charduar area for repair & maint of any items and he himself be responsible for any accident or mishap due to any uncertain reason and no compensation in this regard shall be paid by the department for reason whatsoever.
2M&L for Cleaning of electric substation by uprooting unwanted grass, bushes and trimmingof branches, surface dressing not exc.15cms deep in loose/soft soil to cut the grass,throne busehs and other any type of grass upto root level surrounding the installation and depositing the same at nearby garbage pit, refreshing and re-spreading aggregates inside the premises of sub station if any including cleaning of road/path/fencing etc, maintenance of transformer platform all as specified and directed.
3Trimming of tree branches touching to LT / HT OH lines not exceeding 30 cm girth, shrub, vegetaion, bush and saplings at least upto 5.0 M from outer edge of ACRS including cleaning of road/path/fencing etc. complete all as specified and directed.
4Taking down/dismantling old/rusted/broken steel poles/struts/deteriorated PCC poles,removing from site and making good disturbed surfecs complete all as specified and directed.
5Supplying, transporting, erecting in truely vertical steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts,nuts and screws as specified, including necessary excavation and earth work, PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C1 as in plinth block and coping, disposal of surplus soil to a distance not exceeding 50m and depositing where directed, paintingofexposed surafaces of steel tubular poles with two coats of Aluminium paintover one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint) from plinth block and numbering of poles, painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
6Taking down down/dismantling old/rusted/deshaped cross arms/MS channel or angle for reuse complete all as specified and directed.
7M&L Mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nut, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat with red oxide Zn Chromium and two coats of synthetic enamel paint all as specified.
8Fixing only mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nut, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat with red oxide Zn Chromium and two coats of synthetic enamel paint all as specified.
9Dismantling insulators any type, any size including setting aside serviceable and removal of rubbish material complete all as specified and directed.
10S&F (in repair) Insulator Pin type, povrcelain, vitreous, white, brown or green, insulator including one galvanised mild steel spindle, two galvanised iron washres and one glavanised iron nut, 100 mm height, 65 mm die. For 1100 volts grade complete all as specified.
11S&F (in repairs) insulator shackle type, Porcelain vitreous, white, brown, white or green including, galvanised mild steel straps washers, insulator bolts, washers and nuts, 100 volts working pressure, 75mm height, 90 mm Maximum dia with 31x3 mm galvanised steel straps and dia of bolt 12 mm complete all as specified.
12Re-fixing insulator shackle type any colour including, galvanised mild steel straps washers, insulator bolts, washers and nuts complete all as specified.
13Re-fixing insulator pin type, Porcelain vitreous, any colour including necessary nuts,bolts and washers complete all as specified.
14Dismantling stay assembly complete all as specified and as directed.
15M&L (in repairs) for Stay Assembly comprising of 7/2.24mm galvanised MS stranded wire of rquired length fixed to pole with and including flat iron clamps fabricated out of 50x6mm flat iron and nuts,bolts & washers of suitable size, 40cms long 14mm dia galvanised MS stay bow, 215cms long 20mm dia stay rod with threaded end including bolts & washers, MS stay plate galvanised 230x230x6mm, two thimbles,loop type insulator of size 65x90mm with clearance dia of hole 20mm including necessary excavation, earth work and PCC 1:4:8 type D2 using 40mm stone aggregate complete all as specified and directed.
16M & L in repais Loop type insulator, small size, with overall dimensions 90 mm X 65 mm, cable hole dia 16 mm, creepage distance 41 mm, minimum failing load 44000 N, vitreous porcelain, white, brown or green, Designation A as per IS 5300: 1969 complete all as specified and as directed.
17Dismantling earth wire or copper conductor, service feeder or distributor span removing to store or taken on schedule of credit complete all as specified and as directed.
18Supplying, straining and stretching of Over head aluminium conductor steel reinforced (ACSR) of any size on HT/LT poles including binding and jointing the conductor with and including 14 SWG binding wire and coloured sleeved jumpers with jumper connections with PG clamps complete all as specified.
19Restreching only existing LT OH/ HT OHlines consisting 2 conductor to 8 conductor of ACSR lines 1 line of GI wire, any sizeand tightening with aluminium binding wire of suitable size complete all as specified and directed.
20Dismantling earth wire or copper conductor, service feeder or distributor span complete all as specified and directed.
21S&F (in repairs) guarding Cradles, hexagonal/ rectangular,fabricated with galvanised steel wire 4 mm dia on LT pole including binding with 14SWG MS wire complete all as specified and directed.
22M&L for painting of erected steel tubular swaged poles of LT over head line (Except embedded protion), 9 M long complete including all MS mounted/fixed with pole, earth protection & water pipe (if exists) with one coat of aluminium paint and providing 07 Nos bands/ straps with synthetic enamel paint (black and yellow 30 cm wide each) from top of plinth block and numbering of poles with black synthetic enamel paint on circular yellow background of complete all specified.
23Supply &filling up of transformer oil conforming to IS -335 of 1993 as in topping up/replacementup to desired level of transformer oil capacity complete all as specified and as directed. [Note: Dielectric strength of oil should not be less than 42 KV/cm complete all as specified and directed.] (Make : GULF/POWER OIL or equivalent as approved by GE)
24Supply & laying HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, cross-sectional area 95 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and as directed. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
25M&L Cable End Jointing KitIndoor Termination Cold Shrinkable type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 70 Sqmm to 95 Sqmm complete all as specified and as directed
26M&L Cable End Jointing Kit Outdoor Termination Cold Shrinkable type complete withJointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 70 Sqmm to 95 Sqmm complete all as specified and as directed
27Supply and fixing in repair, connecting, testing and commissioningMCCB 400 Amps, 4 pole, 36 KA 50 Hz with thermal magnatic setting adjustable type in exisitng panels/sheet metal enclosures including suitable size aluminium lugs/thimbles,nuts,bolts & washers etc. complete all as specified.
28Supply and fixing in repair, connecting, testing and commissioningMCCB 200 Amps, 4 pole, 36 KA 50 Hz with thermal magnatic setting adjustable type in exisitng panels/sheet metal enclosures including suitable size aluminium lugs/thimbles,nuts,bolts & washers etc. complete all as specified.
29Supply and fixing in repair, connecting, testing and commissioningMCCB 160 Amps, 4 pole, 36 KA 50 Hz with thermal magnatic setting adjustable type in exisitng panels/sheet metal enclosures including suitable size aluminium lugs/thimbles,nuts,bolts & washers etc. complete all as specified.
30Supply and fixing in repair, connecting, testing and commissioning MCCB of rating 100 Amps 3 pole 25 KA with thermal magnatic setting fixed type complete all as specified.
31Supply and fixing in repair, connecting, testing and commissioning MCCB of rating 100 Amps 3 pole 25 KA with thermal magnatic setting fixed type complete all as specified.
32Supply and fixing in repair, super heavy duty cylindrical type capacitor 3 phase 440 volts 50 Hz AC system for permissible of capacity 2-5 KVAR complete all as specified and directed.
33Supply and fixing in repair, super heavy duty cylindrical type capacitor 3 phase 440 volts 50 Hz AC system for permissible of capacity 10 KVAR confirming to IS:13340 complete all as specified and directed.
34Supply and fix in repair star delta starter fully automatic for 10-15 HP 415 volts 50Hz AC motor in existing panelincluding making all necessary electrical connections all as specified and directed.
35Supply only Aluminium lug 25 sqmm complete all as specified and as directed
36Supply only Aluminium lug 35 sqmm complete all as specified and as directed
37Supply only Aluminium lug 50 sqmm complete all as specified and as directed
38Supply only Aluminium lug 70 sqmm complete all as specified and as directed
39Supply only Aluminium lug 95 sqmm complete all as specified and as directed
40Supply only Aluminium lug 120 sqmm complete all as specified and as directed
41Excavationin trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundations etc. or for shafts, well cess pits, manholes, pier holes, laying of pipe and cables etc. but not exceeding 10 sqm on plan including dressing /trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified.
42Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable)insulated, two or more core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutli stranded, heavy duty 1100 Volts grade of 10 Sq mm cross sectional area, 2 core sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items).
43Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable)insulated, two or more core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutli stranded, heavy duty 1100 Volts grade of 16 Sq mm cross sectional area, 2 core sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items).
44Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable)insulated, two or more core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutli stranded, heavy duty 1100 Volts grade of 35 Sq mm cross sectional area, 3½ core. sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items).
45Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable)insulated, two or more core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutli stranded, heavy duty 1100 Volts grade of 50 Sq mm cross sectional area, 3½ core. sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items).
46Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable)insulated, two or more core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutli stranded, heavy duty 1100 Volts grade of 70 Sq mm cross sectional area, 3½ core. sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items).
47Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable)insulated, two or more core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutli stranded, heavy duty 1100 Volts grade of 95 Sq mm cross sectional area, 3½ core. sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items).
48Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable)insulated, two or more core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutli stranded, heavy duty 1100 Volts grade of 120 Sq mm cross sectional area, 3½ core. sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items).
49S&F in repairs Galvanised mild steel tubing, "Light grade" of 40mm bore complete with all fittings, laid in trenches/ under roads, drain , paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washerws complete all as specified of the following bore (Note :- Excavation & Earth work shall be measrued and paid separately)
50S&F in repairs Galvanised mild steel tubing, "Light grade" of 50mm bore complete with all fittings, laid in trenches/ under roads, drain , paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washerws complete all as specified of the following bore (Note :- Excavation & Earth work shall be measrued and paid separately)
51S&F in repairs Galvanised mild steel tubing, "Light grade" of 80mm bore complete with all fittings, laid in trenches/ under roads, drain , paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washerws complete all as specified of the following bore (Note :- Excavation & Earth work shall be measrued and paid separately)
52Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
53M&L laying well burnt old size bricks, sub calss "B" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection all complete all as specified and directed.
54M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubingof 40 to 150 mm bore complete all as specified and directed.
55Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
56Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
57M & L for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for LT, 200 mm X 150 mm complete all as specified and as directed.
58Supply and fixing or connecting service cable 2 core 10 sqmm 1100 volts grade heavy duty flat or circular PVC insulated aluminum multistranded conductor served with inner sheathing of PVC and overall PVC sheathed on service connection suspended by insulated hangers not more than 1 mtr apart including 4mm dia suspended GI wire complete all as specified and directed.
59Supply and fixing or connecting service cable 2 core 6 sqmm 1100 volts grade heavy duty flat or circular PVC insulated aluminum multistranded conductor served with inner sheathing of PVC and overall PVC sheathed on service connection suspended by insulated hangers not more than 1 mtr apart including 4mm dia suspended GI wire complete all as specified and directed.
60M&L for disconnecting burnt end or portion of 10 sq mm to 185 sq mm 2/3½/4 core cable removing the cable from loop including necessary excavation, earthwork removing brick protection and relaying the same, and reconnecting the cable after preparing fresh ends/terminals to LT panel/Pole/Main switch/Switch breakers etc. complete all as specified.
61M&L for Line separator 4 way PVC type with clamp including fixing with overhead lines of multi conductor of ACSR as and where directed to prevent short circuiting of phase/neutral conductors mutually complete all as specified and directed.
62M&L for Line separator 2 way PVC type with clamp including fixing with overhead lines of multi conductor of ACSR as and where directed to prevent short circuiting of phase/neutral conductors mutually complete all as specified and directed.
63S&F in repair digital panel meter 4 in 1 to measure current,voltage,frequency and power factor having programmable CT ratio and buit in selector switch of size 96x96mm accuracy class 1.0 suitable to work on auxillary power supply of 80-300 volts AC complete all as specified and directed..
64Supply and fix in repair volt meter 3 phase 50-500 volts digital type of size 96x96mm and making all electrical connections all as spacified and directed.
65Supply and fix in repair Amp meter 3 phase 0-100 Amps digital type of size 96x96mm and making all electrical connections all as spacified and directed.
66Supply and fixing maximum demand controller accuracy 1.0 input voltage range 50-500 volts AC (P-P) of size 96x96mm 4 relay output for control including making necessary electrical connections to control the maximum demand at a point at a time including all CTs of suitable ratio required for the same all as specified and directed.
67Supply only MCB TPN 32 amp to 40 amp4 pole complete all as specified and directed.
68M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in to ground (earth pit) not less than 2.25 meters deep below GL with top edge of earth plate to less than 1.50 m below ground level surrounded withadequate quantity of charcoal dust mixed with salt to a packed thikcness of 15 cmconnected to GI earth wire of 4 mm dia by means of nuts, bolts and washers to earth plated at one end and other end to contineous GI wire of OH lines/lighting arrestor or street light poles etc,checknuts of GI and protction by the GI pipe light grade 15 mm nominal bore for earth lead wire from earth plate to 1500 mm above GL with FI clamps made out of 25x3mm fitted with nuts, bolts and washers and 2.5 m long watering pipelight grade of 20 mm nominal bore ,0.63 mm thick CIfunnel, wiremesh, etc. complete including necessary earth work and excavation in soft/loose soil, PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100 mm c/c both ways, earth phophrous bronze testing point , maing good etc. all as specified and shown in electrical plate of SSR- Part-I.
69M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
70Repair/ overhauling of oil cooled servo controlled voltage stabiliser 3 phase 415 volts, 300 KVA by means of supply and replacement of complete wiring connection with suitable size of copper wire, switches, fuses, electronic card, bakalite connections, CTs for auxilary supply etc. Major spare required shall be measured and paid under respective items. Cost of minor spares incl cost of minor CTs for auxilary supply deemed to be included in the quoted rates complete all as specified and as directed.
71S&F in replacement electronic card for reading of incoming and outgoing voltage complete all as specified and directed.
72S&F in replacement resine based single phase feeding transformer suitable for 50/250/300 KVA servo voltage stabilize complete all as specified and directed.
73S&F in replacement current transformer of ratio 100/5A complete all as specified and directed.
74S&F in replacement AC synchronous motor (Servo motor) single phase 240 volts 50 Hz, 60 RPM having torque 10 Kg/cm complete all as specified and directed.
75S&F in replacement Variac assy complete suitable for 3 phase 50/250/300 KVA voltage stabiliser complete all as specified and directed.
76Disconnecting all electrical connectios of incoming/outgoing cables,dismantling/taking out old/deteriorated feeder pilar box and supply, installing, testing and commissioning factory made and testedLT feeder pillar box of size 0.75x0.75x0.25 mtr,cubical, out door type, plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZAC supply system having bus bar chamber with insulated Aluminium bus bars ofrating 200 amps rating installed on porcelain insulator. The panel shall be dust and vermin proof. IP-65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish painted with two coats of super enameeled paint over one coat of red oxide primer from both inside/outside, front and rear both side opening type, with apron for cable entry having suitable locking arrangement including internal wiring with PVC insulated copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size ( but not less than 4.0 sqmm)and comprising of the following:-(i) MCCB160A, 4 pole, AC, 415 Volt,50 Hz,36 KA thermal adjustible between 70-100%. -01 No, (ii) MCCB100A, 4 pole, AC, 415 Volt,50 Hz,16 KA thermal adjustible between 70-100%. -02 No, (iii) Ammeter 0-250 Amp digital typewith CTsratio200/5-01No, (iv) Volt meter 0-500 V digital type-01 No, (v) Indicating lamp for R-Y-B phase neon type- 01 set of three, (vi) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class "B", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level., Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.