Tender For Provision Of Elevated With Overhead Cover Shed Adjacent To Buildingno 1 , And 3, Spl Rep To Security Wall Incl 02 X Pillars At Afmsd Pune And Mw In The Area Of Age ( B / R ) East Under Ge ( North ) Pune. ; 1 Surface Excavation N.Exc 30 Cm Deep And Averaging 15Cm Deep And Getting Out Soft / Loose Soil Complete All As Specified And Directed 2 Excavating In Trenches, N Exc1.5 M Wide And N Exc 1.5 M In Depth For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. N.Exc 10 Sq M On Plan And N Exc1.5 M In Depth And Getting Out Soft / Loose Soil Complete All As Specified And Directed 3 M&L For Pcc Type D2, 1:4:8 ( Using 40Mm Graded Stone Aggregate ) In Foundations, Filling And Mass Concrete Complete All As Specified And Directed 4 M&L For Rcc ( Nominal Mix ) In Type A1, 1:1.5:3 ( Using 20Mm Graded Agg ) As In Foundations, Including Rafts, Footings, Foundation Beams;Plinth Beams; Bases For Columns, Etc Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And Directed 5 M&L For Rcc ( Nominal Mix ) In Type A1, 1:1.5:3 ( Using 20Mm Graded Agg ) As In Columns, Pillars, Piers, Posts And Struts Complete All As Specified And Directed 6 M&L For Rcc ( Nominal Mix ) In Type A1, 1:1.5:3 ( Using 20Mm Graded Agg ) As In Beams, Cantilevers, Bressummers, Lintels Over 1.5M Span Complete All As Specified And Directed 7 M&L Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits ( If Any ) Of Foundation And Plinth Beams And Similar Work Vertical Or To Batter In Rough Finished Flat Surfaces Complete All As Specified And Directed 8 -Ditto- All As Per Item No 7 Here In Before But Columns In Rough Finished Surfaces Ofsquare Or Rectangular Or Polygonal Shape Complete All As Specified And Directed 9 S&F For Mild Steel Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clip Complete All As Specified And Directed 10 -Ditto- All As Per Item No 9 Here In Before But 6Mm To 8Mm Bars For Stirrups Complete All As Specified And Directed 11 M&L For Brick Work With Fly Ash Modularbricks, Straight Or Curved On Plan Exc 6M Mean Radius, Built In Cm 1:6 Complete All As Specified And Directed 12 M&L For 15Mm Thick Cement Plaster In Cm 1:4 On Bricks On Concrete Surfaces Finishing The Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And Directed 13 M&Lfor Preparation Of New Surface Of Wall And Applying Two Coats Of Exterior Acrylic Emulsion Paint Over A Coat Of Primercomplete All As Specified And Directed 14 M&L For Ms Structural Steel Work, Framed As In Trusses, Purlins, Rafter, Post Etc. Conforming To Grade E-250 ( Fe-410W, Quality A ) Including Shaped Washers Including Necessary Cutting Required Length, Notching Drilling, Riveting And Or Welding Or Connecting With Nut Bolts With Angle Cleats, Fish Plat, Gusset Plate And Also Erecting In True Position Complete All As Specified And Directed 15 S & F Steel Work In Tubular Trusses Including Special Shaped Washer, Including Tubular Purlins, Braces / Cross Beams, Ms Base Plate To Column Top With Anchoring Bolts And Base Plates To Tubular Trussesetc. Complete All Fixing Byusing Erw Or Induction Butt Weldedtubes Confirming To Is-1161-1979 Grade St-240, Complete All As Specified And Directed 16 M & L Labour For Mild Steel Fe 410-W ( Gde-E-250 ) Quality-B In Plates ( Plain Or Chequered ) Channels, Square Cut Or Notched ( Ordinary And Counter Sunk ) Forming Holes, With Riveted, Bolted Or Welded Attachment Complete All As Specified And Directed 17 M& L For Preparation Of New Steel Surfaces And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Complete All As Specified And Directed 18 S&F In Pre- Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet With Mangalore Tile Pattern Finish Of 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering, Fixed With Self Tapping Screws Complete All As Specified And Directed 19 M&L For Filling Under Floors With Moorum Laid In Layers N. Exc 15 Cm Thick Spread Levelled And Rammed Watering And Compacted Complete All As Specified And Directed 20 M&L For Hardcore Of Gauge N Exc 63Mm, Deposited, Spread And Levelled In Layers N Exc15cm Thick, Watered And Rammed To A True Surface Complete All As Specified And Directed 21 M&L For 75Mm Thick Pcc Type C-2, 1:3:6 ( 40Mm Graded Aggregate ) As In Sub Base Of Floor Complete All As Specified And Directed 22 M&L For Machine Cut Kota Stone Slab Flooring 20-25Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete Over 20Mm Thick Screed Bed Or Bedding Of Layer In Cm 1:6 Complete All As Specified And Directed 23 M&L Kota Stone Slab 20-25Mm Thick In Riser Of Steps , Skirting, Dado And Pillar Laid Over Cement Screed And Jointed Including 10Mm Thick 1:4 Backing Coat Etccomplete All As Specified And Directed 24 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm Complete All As Specified And Directed 25 Removing Excavated Soil Material N Exc 50M And Depositing Where Directed At A Level N Exc 1.5 M Above The Starting Point Complete All As Specified And Directed 26 M&L For 200Mm Bore Rcc Pipe Class Np2 Laid And Jointed In Cement Mortar With Collars And Tested Complete All As Specified And Directed 27 M&L For Pcc 1:4:8 Type D2 As In Concrete Bed To Drain Pipes Of 200Mm Bore Including Packing Under And Haunching Against The Sides Of Pipe After They Are Laid Complete All As Specified And Directed 28 M & L For Rainwater Gutter System Of Swr Pipe 180 Mm Nominal Dia. Half Round Type Alongwith All Accessories / Fittings Complete All As Specified And Directed. Make : Prince Model Hpr18r Or Equivalent Ofinfra, Supreme, Kisan, Astron Plastic, Amogh Plast, Finolex 29 S&F In Repairs 110Mm Bore Pvc ( Swr ) Grade Single Socketed Pipes In Any Length Complete With Rubber Ring Joints Laid In Trenches Or In Floors Complete All As Specified And Directed 30 S&F In Repairs Pvc ( Swr ) Bends Of Any Radius Of 110Mm Bore Complete All As Specified And Directed 31 M&L Pcc 1:3:6 Type C-2 Using ( 40Mm Graded Stone Aggregate ) 75Mm Thick Finished Even And Smooth Without Using Extra Cement As In Plinth Protection, Pcc Path Laid In Alternate Bays N.Exc 3.0M Length, Finished Surfaces Even And Smooth Without Using Extra Cement Incl Filling The Joints With Mix Of Bitumen And Sand Complete All As Specified And Directed 32 Demolition Ofbrickwork Or Stone / Block Masonry, Built In Cementmortar Dressed Stonework And Precast Concrete Articles Complete All As Specified And Directed 33 Excavation In Trenches N.Exc 1.5M Wide And N.Exc 1.5M In Depth For Foundation, Manholes Etc And Getting Out In Hard / Dense Soil 34 M&Lfor Pcc ( 1:3:6 ) In Type C-2 In Foundation Filling & Mass Conc. 35 M&L For Repair Of Steel Gate Of Any Size , Any Shape And Any Position. Taking Down Steel Gate And Repair Holdfast, Uplifting Of Steel Gate, Welding To Required Member, Repair / Greasing To Roller, Repair And Repositioning Ofbase Rail , Make In True Position To Revolve, Complete All As Specified And Directed By Engr- In - Charge. 36 S&F In Repair 2Mm Thick Fibre Glass Reinforced Translucent Corrugated Or Plain Sheeting With Corrugation Side Lap Fixed With Coach Screw And Washers In Roof Or Wall Etc Complete All Asspecified And Directed. 37 Taking Down Cement Plaster On Brick / Stone Wall Including Raking Out Joints, Hacking For Key Scrubbing Down With Water Etc. And Clearing Off The Premises Complete All As Specified And Directed 38 M&L For Two Coats Of Cement Base Paintover A Coat Of Primer On Newly Plastered Surfaces Of External Walls Including Preparations Of New Surfaces Complete All As Specified And Directed 39 Material And Labour For 18-20Mm Thick Granite ( Of Any Type ) Work ( Table Rubbed And Polished ) In Steps , Jambs. Pillars, Window Cills, Cooking Platforms And Like In Cement Mortar ( 1:4 ) , Pointing In White Cement ( 1:2 ) Using Marble Dust With Admixture Of Pigment To Match Withshade Of Granite Incl Demolition Of Existing Stone Of Any Description Complete All As Specified And As Directed. 40 M&L Broken Glass Coping On Top Of The Wall In Cm 1:3Complete All As Specified And As Directed. 41 M&L 2 Coats Of Synthetic Enamel Paint Old Steel Surface Including Preparation Complete All As Specified And Directed. 42 Supply And Laying 40Mm Outer Dia, Double Walled Corrugated ( Dwc ) Hdpe Duct Pipe Conforming To Is- 14930 Pt-Ii With Antirodent And Non Flame Propogating Properties Plete With Fittings For Cable Protection Complete All As Specified And As Directed. 43 Supply, Lay, Joint, Test And Commissioning Of Lt Under Ground Cable 1100 Volt Grade , Xlpe Insulated And Pvc Sheathed Heavy Duty Armoured With Aluminium Conductor , Is 7098-I Marked, Laid In Trenches / Ducts / Fixed On Poles / Walls / Laid Under Roads / Paths / Drains / Culverts Or Encased In Gi Pipe Including Cable Glands, Lugs Jointing Material Etc Complete All As Specified And Directed. Cable Of The Following Size.10 Sq Mm 2 Core 44 Material And Labour For Point Wiring Using Approved Colour Coding As Per Is , With Multistranded Copper Conductor 1.5 Sqmm ( Nominal Area ) , Two Single Core, Pvc Insulated And Unsheathed Frls Cable 1100 Volts Grade Isi-694 Marked Drawn Through In And Including Heavy Duty Pvc Concealed Conduit Including All Accessories, Metal Flush Box Of Suitable Module, With Earth Dolly, Covered With Twin Colour ( Specified By Engr-In- Charge ) Modular White Cover Plate & Frame After Chasing In Brick / Stone Masonry Walls Etc For Accomodating Modular Switches, Sockets, Regulators Etc Including Pvc Insulated Multistranded Copper Conductor 1.5 Sqmm ( Nominal Area ) Single Core Frls Cable As Earth Continuity Conductor Along With Wiring And Connecting To Earth Dolly, Providing Copper Cable Sockets Plate / Bottle Type Of Adequate Size At Termination End Of Cable Point Wiring In Dbs, Switch Boards, Fittings Fixtures All As Specified And As Directed For The Following 45 -Ditto - All As Per Item No 44 Above But One Light / Wall / Exhaust Fan Pointcontrolled By One, One Way Switch 6 Amps Complete All As Specified And As Directed 46 -Ditto - All As Per Item No 44 Above But One5 Pin Socket Outlet Plug Point, 6 Amps, Controlledby One, Switchon Same Board Complete All As Specified And As Directed 47 -Ditto - All As Per Item No 44 Above But One5 Pin Socket Outlet Plug Point, 6 Amps, Controlledby One, Switchon Independent Board Complete All As Specified And As Directed 48 -Ditto - All As Per Item No 44 Here-In Before But Using 2.5 Sqmm Single Core Copper Conductor Frls Cable Of Multistranded Pvc Insulated Unsheathed 1100 Volts Grade For One 6 Pin Socket Outlet Plug Point, 16 Amps Independentincluding Necessary Running Of 2.5 Sqmm Pvc Insulatedmultistranded Copper Conductor Single Core Frls Cable As Earth Continuity Conductor Along With Wiring And Connecting To Earth Dollyproviding Copper Cable Sockets Plate / Bottle Type Of Adequate Size At Termination End Of Cable Point Wiring In Dbs, Switch Boards, Fittings Fixturesall As Specified And As Directed 49 Supply And Fixingmodular Switch - 16 Amps, Single Pole One Way, One Module Complete All As Specified Andas Directed. 50 S & Fmodular Socket Outlet Multipurpose 6 Amps, 5 Pin, 2 Module, Complete All As Specified Andas Directed. 51 S & Fmodular Socket Outlet Multipurpose 16 Amps, 6 Pin-Shuttered Type, 2 Module, Complete All As Specified Andas Directed. 52 S & F Ceiling Rose, 3 Phase / Pvc / Polycarbonate, Complete All As Specified Andas Directed 53 S & F Sheet Metal Enclosure Mcb Db Spn 8 Waywith 100 Amps Rated Bus Bar 240 Volts Double Door With Magnetic Locking System Including Necessary Provision For Inserting The Dbs In Wall By Cutting The Brick / Stone Masonary Etc And Making Good Of Disturbed Surface To Match The Existing Colour Of Wall Complete All As Specified And As Directed 54 Supply And Fixing Amp Rating 240V, 10Ka C Curve Miniature Circuit Breaker ( Mcb ) Sp 5 To 32 Ampand Current Carrying Capacity In The Mcb Db Complete With Connection Testing And Commissioning Complete All As Specified And Directed 55 Supply And Fixing Amp Rating 240V, 10Ka C Curve Miniature Circuit Breaker ( Mcb ) Spn32 Ampand Current Carrying Capacity In The Mcb Db Complete With Connection Testing And Commissioning Complete All As Specified And Directed 56 S & F Submain Wiring With 2 Single Core ( Frls ) Pvc Insulated Unsheathed Multistranded Flexible Copper Conductor Cable, Of 4.0 Sqmm And One Single Core 4.0 Sqmm Flame Retardent Low Smoke ( Frls ) Pvc Insulated, Unsheathed, Multistranded, Flexible Copper Cable As Earthing Lead , All As Per Is 694 / 1990 Drawn Through Including Concealedin Stone / Bricksmasonary Pvc Conduit And Conduit Accessories Heavy Duty Isi Marked, Providing Copper Cable Sockets Plate / Bottle Type Of Adequate Size At Termination End Of Cable Point Wiring In Dbs, Switch Boards, Fittings Fixturesall As Specified And As Directedall As Specified And As Directedcomplete All As Specified Andas Directed.Note :- ( Two Runs Of Main Copper Wire, One Run Of Earth Wire Cable & Pvc Conduit Shall Be Measured Together As One Length ) . 57 S & F For Recess Mounted 2 X 2 Square Led Panel 36 Watts, 596 X 596 X 9Mm Size, Sleek Design Aluminium Housing, Polycarbibate Diffuser White Powder Coated Finish Operating Voltage 140 Volts - 270 Volts, Ac, 50 Hz Complete All As Specified And As Directed. Make- Halonix Hlfpr22-11-36-Cw-37Mm, Philips Rc383b Led 4000 Psu Odwh Pir, Jaquar Lultu1s036xc. 58 1.Supply And Installation, Commissioning Ofwall Mounting Air Cooled Split Type Unit Air Conditioner Electric Driven Single Phase Indoor Unit And Outdoor Unit With Cordless Remote Control Unit And With In Built Airioniser And Plasma Filter For Better Indoor Air Quality Cutting , Brazing Andconnecting The Copper Pipe Of Size 1 / 2 Inch And 1 / 4 Inch Size Of Pipe And Making Holes As For Passing Of Copper Pipes And Electric Cables And Pressure Testing With Nitrogen And Freon Gas Vacumising The System And Charging The Non Cfc Refrigerentand Testing The Complete System For Smooth Functioning Of Split Ac Up To Satisfactioning, 5 Star Rating, Confirming To Is-1391 Para Ii 1992 Herimatically Sealed Air Compressor Workingwith Non Cfc Refrigerent Suitable For Wall Mounting 6000 K Cal / Hrs 1.5 Ton Complete All As Specified And Directed. 59 2. Supply And Fix Mcb Protected Srcd Box 4 Module 25 Amps With Surface Mounted Pvc Enclosure Srcd ( Socket Residual Current Device ) Single Pole With A Three Pin Socket & Top Complete With 25 Amps Mcb Single Pole.Make . Havells Cat Part No. Dhdtcsn0251020 Or Equvalent Schneider / Siements / Legrand 60 Note : 1. Rerformance Security:- Refer Condition 22 Of Special Conditions. 2. Quoted Contract Sum Shall Be Arrived At After Deducting The Amount Of Credit Schedule ( Refer Schedule Of Credit In Pdf Form For Quantity, Rate And Amount Etc. ) For Old Unserviceable Materials Retrieved From Site.