Tender For Repairs To Water Proofing Treatment To Walls, Roof And Connected Works At Zone B And E Under Ge Chennai., chennai-Tamil Nadu

Military Engineer Services-MES has published Tender For Repairs To Water Proofing Treatment To Walls, Roof And Connected Works At Zone B And E Under Ge Chennai.. Submission Date for this Tender is 05-02-2024. Rain Wear Tenders in chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

41418337
Corrigendum : Tender For Repairs To Water Proofing Treatment To Walls, Roof And Connected Works At Zone B And E Under Ge Chennai.
Open Tender
Indian
Tamil Nadu
chennai
05-02-2024

Tender Details

Tender For Repairs To Water Proofing Treatment To Walls, Roof And Connected Works At Zone B And E Under Ge Chennai. ; 1 Dismantling Of Plain Or Corrugated Steel Sheeting, Any Gauge, Thickness, Includingnainital Or Similar Pattern Roofcoverings 2 Excavating In Post Holes ( Or Similar Holes ) Each N Exc 0.5Cu M, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm In Hard / Dense Soil Complete All As Specified And Directed. 3 Dismantling Of Wall And Ceiling Boards ( Fibre Pulp, Insulation Etc ) Or Insulation Boards / Slabs / Blankets Any Thickness Including Cover Fillets 4 Demolition Of Brick Or Stone Masonry, Built In Cement Mortar Including All Quoins, Arches, Pillars Etc But Excluding Ashlars Facings, Dressed Stone Work, Complete All As Specified And Directed. 5 M&L For Flyash Brick Work With Old Size Fly Ash Sub Class B Bricks Straight Or Curved On Plan Exc 6M Mean Radius Built In Cm 1:4 6 Takingdown Cement Plaster On Brick Work Or Stone Walls Etc Including Racking Out Of Joint , Hackingfor Key Scrubbing Down With Water Etc 7 M&L For Rendering 15Mm Thick On Fair Faces Of Brick Work In Two Layers, First Layer 10Mm Thick In Cm 1:6And Second Finishing Coat 5Mm Thick In Cm 1:4 Mixed With Water Proofing Compound As Per Manufacturers Instructions And Finished Even And Fair On External Surfaces. 8 M&L Rendering In Cm 1:3, 10 Mm Thick As Inceiling On Fair Faces Of Concrete Surfaces Including Finished Even And Fair In Patchesall As Specified And As Directed. 9 M & L For Applying Three Coat Of White Wash As In Ceiling Incl Preparation Of Newly Plastered Ceiling Surfaces All As Specified And As Directed. 10 Material And Labour For Applying Two Or More Coats Of 100% Premium Acrylic Mulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistance As Per Is 15489-2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade ( Company Depot Tinted ) With Silicon Additives @1.43 Litre / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre / 10 Sqm Over New Surfaces Complete Including Preparation Of Newly Plastered / Treated Surfaces Of Walls All As Specified And As Directed By The Engineer-In-Charge.Make: Apex Ofasian Or Equivalent Of Shalimar / Nerolac / Berger. 11 S&F In Repairs 20 Mm Bore Ball Valves Highpressure Of Ptmt Withepoxy Coatedaluminium Rod &Highdensity Plastic Ballscrewed For Iron Pipeand Fixed. ( Minimum Weight 20Mm - 210 Gms ) . 12 S&F In Repairs 25 Mm Bore Ball Valves Highpressure Of Ptmt Withepoxy Coatedaluminium Rod &Highdensity Plastic Ballscrewed For Iron Pipeand Fixed. ( Minimum Weight 25Mm - 455 Gms ) 13 M&L Forprepare The Surface Thoroughly By Cleaning, Washing And Removing Dust, Dirt, Oil, Grease, Vegetation, Plants And Loose Particles.In Existing Old Terraces With Brickbat Coba Or Screeds, Damaged Or Hollow Portions, Sharp Edges, Etc. Must Be Cut And Removed Till The Mother Slab. The Slab Should Be Recoated With Slurry Of Dr. Fixit Pidicrete Urp And Cement In 1:1 Proportion. After Drying, The Surface Cracks Must Be Filled With Dr. Fixit. Crack-X Or Polymer-Modified Mortar In Case Cracks Are Wider Than 5 Mm.Cracks Less Than 2 Mm, Should Be Cleaned Free Of Dust With A Vacuum Cleaner.Apply Dr. Fixit Primeseal In The Crack And Let It Dry. Then Pour Dr. Fixit Newcoat Into These Cracks And Waitfor It To Dry.Bitumen Based Waterproofing Treatments If Existing, Must Be Completely Removed By Mechanical Scarificationor By Any Other Effective Mechanical Means.And Dilute 2 Parts Of Dr. Fixit Primeseal With 1 One Part Of Water. This Dilution Will Cover 7 To 8 Sq.Mt. Allow It To Dry For6 To 8 Hrs.Apply The First Coat Of Dr. Fixit Newcoat Without Any Dilution At The Rate Of 2 M2 Per Litre And Allow It To Dry Before Taking Up The Second And Third Coats, The Rate Of Application Being The Same. And Open Woven Glass Fibre Mesh Of 2.5 Mm X 2.5 Mm Must Be Sandwiched Between The First And Second Coat. While The 1St Coat Is Still Wet, Place The Fibre Mesh On It. After The Coat Dries, Start Applying The 2Nd Coat Of Dr. Fixit Newcoat. , To Take Care Of Al Lmovements In Cracks And Cold Joints In The Substrate Caused By Variations Of High And Low Temperatures. This Reinforcement With Fibre Mesh Shall Be Extended Up To The Drip Mould Over The Angle Fillets.The Sequence Of Colours Of Dr. Fixit Newcoat Can Be Decided Depending On The Desired Top Coat Colour. Drying Time Between Coats Will Be 6 To 8 Hrs.A Llow The System To Air Cure For 7 Days Minimum. A Total Thickness Of 1 To 1.2 Mm Must Be Achieved Whendr. Fixit Newcoat Is Dry. 7 Days After Application Of Dr. Fixit Newcoat, It Should Be Checked For Its Adhesion To The Substrate. For This, Mark A Square Of 5 Cm X 5 Cm, For Every 200 Sq. M Of The Area.Cut The Square With A Knife Diagonally Across The Square. Rip The Coating And Check The Coating’S Thickness With Vernier Callipers, To See If The Dry Film Has An Average Thickness Of 1 Mm. This Should Be Done In Every 200 M2.Over The Entire Roof. Once These Tests Are Done, Reapply Newcoat Over These Portions, In Accordance With The Dr. Fixit Newcoat All As Specified And Directed 14 M&L Forpreparati Of New Surface For Treatment Must Be Thoroughly Cleaned Of All Laitance, Loose Material, Oil, Grease, Etc. By Mechanical Means Such As Wire Brushing. Treat Any Areas Affected By Algae, Moss Or Fungal Growthwith Biocide Wash Solution. All Surface Cracks Up To 5 Mm Width Should Be Filled Up With Dr. Fixit Crack-X.Cracks More Than 5 Mm And All Separation Gaps Should Be Filled Up With Dr. Fixit Pidicrete Urp Modifiedmortar Or As Specified. Pri Ming Saturated Surface Dry Condition Proceed For Priming Using Dr. Fixit Primeseal Diluted In 2:1 Ratio With Water ( 2Parts Primeseal Diluted With 1 Part Water ) . Maintain The Spreading Rate Of 8-10 Sq Mtr Per Litre For A Single Coat Application To Achieve About 20 – 25 Microns Dft. Allow It To Dry For 6-8 Hrs.Applicat On Use Dr. Fixit Raincoat Waterproof Coating Directly From The Container. Stir Contents Well Before Use. And Apply One Coats Of Dr. Fixit Raincoat Waterproof Coating Without Dilution By Brush Or Roller For Rain Lashing Walls At The Thickness Of 120 – 130 Microns All As Specified And Directed . 15 M&L Forpreparati Of Existing Substrates Must Be Cleaned To Remove All Dirt, Vegetation, Plants, Mildew And Other Contaminants. Treat Any Areasaffected By Algae, Moss Or Fungal Growth With Biocide Wash Solution. This Is Accomplished By Pressurecleaningequipment With A Minimum Capability Of 100-140 Bar Water Pressure. All Grease, Oils And Asphalt Materials Must Be Removed Completely.. All Surface Cracks Up To 5 Mm Width Should Be Filled Up With Dr. Fixit Crack-X.Cracks More Than 5 Mm And All Separation Gaps Should Be Filled Up With Dr. Fixit Pidicrete Urp Modifiedmortar Or As Specified. Pri Ming Saturated Surface Dry Condition Proceed For Priming Using Dr. Fixit Primeseal Diluted In 2:1 Ratio With Water ( 2Parts Primeseal Diluted With 1 Part Water ) . Maintain The Spreading Rate Of 8-10 Sq Mtr Per Litre For A Single Coat Application To Achieve About 20 – 25 Microns Dft. Allow It To Dry For 6-8 Hrs.Applicat On Use Dr. Fixit Raincoat Waterproof Coating Directly From The Container. Stir Contents Well Before Use. And Apply One Coats Of Dr. Fixit Raincoat Waterproof Coating Without Dilution By Brush Or Roller For Rain Lashing Walls At The Thickness Of 120 – 130 Microns All As Specified And Directed . 16 M&L For Aplly A Tack Coat Coat Of Bitumen 85 / 25 At The Rate Of 1.20 Kg / Sqm On Rooof Surfaces Including Cleaning Of Surfaces In Patches Including Sealing The Open Jointsin The Water Prooffelt Including One Coat Solar Reflective F Aluminium Painting @ .10 Lit Per Sqm On Repaired Portion Complete All As As Specified And Directed 17 M&L For Pcc 1:2:4 Type B1 ( Using 20Mm Graded Aggregate ) In Copings, Kerbs, Channels, Water Through And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Etc Complete All As Specified And Asdirected. 18 S&F Pre- Painted Galvatume Aluminum Zinc Coating Gi Based Corrugated Steelsheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws As Specified 19 S&F For Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws As Specified 20 Dismantling Of Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For All As Specified And Directed By Engr-In-Charge 21 S&F Rolled Sections As In Main And Cross Beams, Hip And Jack Rafters; Purlins Where Connected To Common Rafters And Running Railsand Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Fe-410- W ( Gde- E-250 ) Quality-Ball As Specified And As Directed 22 M&L For Applying Two Coats Of Synthetic Enamelled Paint Over A Coat Of Red Oxide On Steel Or Iron Surfacebased Materials Of Any Description , Not Other Wise Described Over 10 Cm Width Or Girth Including Preparation Of New Surfaces. 23 S&F For Framed Brackets Of Angles Or Tees With Web And Flanges Cut Toshape, Drilled And Countersunk For Screw, Including Bending Andwelding Angles, As Necessary, Gusset Plates, Riveting, Etc.. N Exc10 Kg Each Brackets, Conforming To Fe.290.Gde-E-165 ( Bracketsover 10 Kg Each To Be Measured Under Structural Steel ) All As Specified And As Directed 24 S&F For Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. Fe-410- W ( Gde- E-250 ) Quality- B ( Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated ) All As Specified And Directed. 25 Preparation Of New Steel Surfaces And Appying Two Coats Ofblack Bituminous Paint All As Specified And Directed. 26 Cutting Holes Into Or Through Brick Walls But In Brick Walls Superficial Area N.Exc 150Sqcm Built, In Cement Mortar Or Cement Lime Mortar And Stone Walls Built In Lime Mortar Or Walls Of Lime Concrete. And Making Good In Cement Mortar 1:3 Or Cement Concrete 1:2:4 Type B-L As Required 27 Cutting Holes Into Or Through Brick Walls Built In But In Brick Walls Area Exc 150 Sqcm But N.Exc 400 Sqcm Built In Lime Mortar And Stone Walls And Making Good In Cement Mortar 1:3 Or Cement Concrete 1:2:4 Type B-L As Required 28 Complete Removal Of Existing Roof Treatment Including Vegetation And Plantsany Type And Demolition Of Cement Concrete Padding At Roof Slab N Exc 15Cm Thickness All Specified And Directed By Engr-In-Charge 29 M & L For Plain Cement Concrete 40Mm Thick Average Thickness As Roof Padding Type B0, 1:2:4 ( 12.5Mm Graded Aggregate ) Finished Fair And Even Over Concrete Surface On Roof Top, And Finished Even And Smooth With 10Mm Thick Cement Plaster In Cm 1:4 Mixed With Wpc @ 200 Ml Per Bag, When The Concrete Is Green All As Per Manufacturer Instructions ( Note: Water Proofing Compound Will Be Paid Under Measured Seperately ) 30 Supply Only Liquid Water Proofing Compoud 31 Cleaning And Preparation Of Newly Plasteres Roof Surfaces And Applying The Water Proofing Treatment As Under. ( A ) Applying 1St Course Of Bituminious ( Oil Based ) Primer Confirming To Is-3384 @ 0.4 Lit / Sqm Over The Screed Bed. ( B ) Applying 2Nd Course Of A Coat Of Binding Material With Blown Type Bitumen Of Grade 85 / 25 Heating To Working Temperature Of 180 0 C And Applied @ 1.2 Kg / Sqm. ( C ) Applying 3Rd Course Of App ( Atactic Polypropylene ) Based Polymeric Membrane Minimum Weighing 3.6 Kg / Sqm And Minimum 3 Mm Thick Reinforced With Polyster Non Wove Fabric ( Wt Not Less Than 150 Gms / Sqm ) Laid With 75 Mm Side Overlapand 100 Mm Overlap By Forced / Torch Application As Per Manufactures Instructions. ( D ) Applying 4Th Course Of A Coat Of Bonding Material With Blown Type Bitumen Of Grade 85 / 25 Heating To Working Temperature Of 180 Degree C And Applied @ 1.2 Kg / Sqm Over App Membrane, ( E ) Applying 5Th Course Of A One Coat Of Solar Reflective Aluminium Paint @ 0.10 Litre / Sqm On Roof Surfaces Complete All As Specified And Directed. 32 Taking Down Of Existing Cemen Or Lime Plaster Along With The Existing Water Proofing Treatment Including Vegetation And Plants On Walls Andapplying 10 Mm Thick Cement Plaster 1:3 Mixed With Liquid Water Proofing Compound @ 200 Ml Per Bag, Cleaning And Preparation Of Newly Plastered Wall Surfaces And Applying The Water Proofing Treatment As Under. ( A ) Applying 1St Course Of Bituminious ( Oil Based ) Primer Confirming To Is-3384 @ 0.4 Lit / Sqm Over The Screed Bed. ( B ) Applying 2Nd Course Of A Coat Of Binding Material With Blown Type Bitumen Of Grade 85 / 25 Heating To Working Temperature Of 180 0 C And Applied @ 1.2 Kg / Sqm. ( C ) Applying 3Rd Course Of App ( Atactic Polypropylene ) Based Polymeric Membrane Minimum Weighing 3.6 Kg / Sqm And Minimum 3 Mm Thick Reinforced With Polyster Non Wove Fabric ( Wt Not Less Than 150 Gms / Sqm ) Laid With 75 Mm Side Overlapand 100 Mm Overlap By Forced / Torch Application As Per Manufactures Instructions. ( D ) Applying 4Th Course Of A Coat Of Bonding Material With Blown Type Bitumen Of Grade 85 / 25 Heating To Working Temperature Of 180 Degree C And Applied @ 1.2 Kg / Sqm Over App Membrane, ( E ) Applying 5Th Course Of A One Coat Of Solar Reflective Aluminium Paint @ 0.10 Litre / Sqm On Wall Surfaces Complete All As Specified And Directed. 33 M & L For Galvanised Powder Coated Snap Grid Framework Of Size 605 X 605Mm For False Ceiling All As Specified Including Vinyl Laminated Mpl Gypsum Panels ( Gyptech ) 9Mm Thick Of Size 60 X 60 Cm Fixing Withstapples On Snap Grid By Means Of Gi Wires Not Less Than 4Mmdia Hooks And Raw Plug Etc Centre Of Amke. Gyptech / Armstrong Or Equivalent All As Directed By Engr-In-Charge 34 M&L Pcc Type B2 ( 1:2:4 ) Using 40Mm Graded Stone Aggregates As In Foundation, Filling And Mass Concrete 35 Cutting Grooves In Brick Wall, 75Mm Wide And 65Mm Deep And Shaping Horizontal Face Of Groove With Cement Mortar 1:3 Complete All As Specified And Directed. 36 Disconnecting Existingtanks, Setting Aside ( Orlowering If Required ) For Repairs, Cleaning, Etc. Andcleaning And Removing All Scale And Dirt, Etc, From Tanks And From Mouths Of Circulating Pipes, Etc. Capacity Exc 250Ltrs But N.Exc 500Ltrs Complete All As Specified And Directed. 37 All As Per Item 36.00 Above But For Exc 500 Ltand Not Exc 1000 Lt Capacity 38 All As Per Item 36.00 Above Butfor Exc 1000 Ltand Not Exc 2000 Lt Capacty 39 S&F Galvanised Steel Water Tubing Medium Grade Including Provision Of All Pipe Fittings Such As Bends, Tees, Elbows, Reducers, Unions, Plugs, Sockets Etc., Fixed To Walls / Ceilings Or Laid In Floors Etc., Complete Including Taking Up ( Or ) Down The Existing Gi Pipe Completely All As Specified For 15Mm Bore Pipes. 40 All As Per Item No 39.00 Above But 20Mm Bore Pipes 41 All As Per Item No 39.00 Above But 25Mm Bore Pipes 42 Refixing Onlygalvanised Steel Water Tubing Medium Grade Including Provision Of All Pipe Fittings Such As Bends, Tees, Elbows, Reducers, Unions, Plugs, Sockets Etc., Fixed To Walls / Ceilings Or Laid In Floors Etc., Complete Including Taking Up ( Or ) Down The Existing Gi Pipe Completely All As Specified For 15Mm Bore Of Pipes. 43 All As Per Item No 42.00 Above But 20Mm Bore Pipes 44 All As Per Item No 42 Above But 25Mm Bore Pipes 45 M & L Gun Metal Globe Or Gate Valve With Iron Wheel Head Screwd Both Ends For Iron Pipe And Fixed For 25 Mm Dia Bore Pipes Fixed In Repairs 46 M & L Gun Metal Globe Or Gate Valve With Iron Wheel Head Screwd Both Ends For Iron Pipe And Fixed For 20 Mm Dia Bore Pipes Fixed In Repairs 47 S&F Rotational Moulded Polyethylene Water Tank ( Cylindrical Vertical Closed Top ) Hoisted And Fixed In Position Capacity Of Tank 1000 Ltrs Including Dismantling Of Existing Tank Of Any Descriptionand S&F 20 Mm Ball Ptmt Ball Valve High Pressure With Exposy Coated Aluminum Rod And High Density Plastic Ball Screwed For Iron Pipe. 48 S&F Rotational Moulded Polyethylene Water Tank ( Cylindrical Vertical Closed Top ) Hoisted And Fixed In Position Capacity Of Tank 500 Ltrs Including Dismantling Of Existing Tank Of Any Descriptionand S&F 20 Mm Ball Ptmt Ball Valve High Pressure With Exposy Coated Aluminum Rod And High Density Plastic Ball Screwed For Iron Pipe. 49 Pvc ( Swr ) Pipes 110Mmsingle Socketed , In Any Length With Rubber Ringjoints , Fixed To Walls / Floor, Spouts Etc Complete Including Dismantling Existing Pipes Of Any Description All As Specified Anddirected. 50 Pvc ( Swr ) Bends With Oval Access Door 110Mm Fixed In Repairs Complete All As Specified Anddirected.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-01-2024
2 30-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPAIRS TO WATER PROOFING TREATMENT TO WALLS, ROOF AND CONNECTED WORKS AT ZONE B AND E UNDER GE CHENNAI
Sl. No. Item Description
1Dismantling of Plain or corrugated steel sheeting,any gauge, thickness, includingNainital or similar pattern roofcoverings
2Excavating in post holes (or similar holes) each n exc 0.5cu m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/dense soil complete all as specified and directed.
3Dismantling of wall and ceiling boards ( fibre pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets
4Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
5M&L for flyash brick work with old size fly ash sub class B bricks straight or curved on plan exc 6M mean radius built in CM 1:4
6Takingdown cement plaster on brick work or stone walls etc including racking out of joint , hackingfor key scrubbing down with water etc
7M&L for rendering 15mm thick on fair faces of brick work in two layers, first layer 10mm thick in CM 1:6and second finishing coat 5mm thick in CM 1:4 mixed with water proofing compound as per manufacturers instructions and finished even and fair on external surfaces.
8M&L Rendering in CM 1:3, 10 mm thick as inceiling on fair faces of concrete surfaces including finished even and fair in patchesall as specified and as directed.
9M & L for applying three coat of white wash as in ceiling incl preparation of newly plastered ceiling surfaces all as specified and as directed.
10Material and labour for applying two or more coats of 100% premium acrylic mulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of newly plastered /treated surfaces of walls all as specified and as directed by the Engineer-in-Charge.Make: APEX ofAsian or equivalent of shalimar / Nerolac/ Berger.
11S&F in repairs 20 mm bore Ball valves highpressure of PTMT withepoxy coatedAluminium rod &highdensity plastic ballscrewed for iron pipeand fixed. (Minimum weight 20mm - 210 gms) .
12S&F in repairs 25 mm bore Ball valves highpressure of PTMT withepoxy coatedAluminium rod &highdensity plastic ballscrewed for iron pipeand fixed. (Minimum weight 25mm - 455 gms)
13M&L forPrepare the surface thoroughly by cleaning, washing and removing dust, dirt, oil, grease, vegetation, plants and loose particles.In existing old terraces with brickbat coba or screeds, damaged or hollow portions, sharp edges, etc. must be cut and removed till the mother slab. The slab should be recoated with slurry of Dr. Fixit Pidicrete URP and cement in 1:1 proportion. After drying,the surface cracks must be filled with Dr. Fixit. Crack-X or polymer-modified mortar in case cracks are wider than 5 mm.Cracks less than 2 mm, should be cleaned free of dust with a vacuum cleaner. Apply Dr. Fixit Primeseal in the crack and let it dry. Then pour Dr. Fixit Newcoat into these cracks and waitfor it to dry.Bitumen based waterproofing treatments if existing, must be completely removed by mechanical scarification or by any other effective mechanical means.and Dilute 2 parts of Dr. Fixit Primeseal with 1 one part of water. This dilution will cover 7 to 8 sq.mt. Allow it to dry for6 to 8 hrs.Apply the first coat of Dr. Fixit Newcoat without any dilution at the rate of 2 m2 per litre and allow it to dry before taking up the second and third coats, the rate of application being the same. and open woven glass fibre mesh of 2.5 mm x 2.5 mm must be sandwiched between the first and second coat. While the 1st coat is still wet, place the fibre mesh on it. After the coat dries, start applying the 2nd coat of Dr. Fixit Newcoat. , to take care of al lmovements in cracks and cold joints in the substrate caused by variations of high and low temperatures. This reinforcement with fibre mesh shall be extended up to the drip mould over the angle fillets.The sequence of colours of Dr. Fixit Newcoat can be decided depending on the desired top coat colour. Drying time between coats will be 6 to 8 hrs.A llow the system to air cure for 7 days minimum. A total thickness of 1 to 1.2 mm must be achieved whenDr. Fixit Newcoat is dry. 7 days after application of Dr. Fixit Newcoat, it should be checked for its adhesion to the substrate. For this, mark a square of 5 cm x 5 cm, for every 200 sq. m of the area.Cut the square with a knife diagonally across the square. Rip the coating and check the coating’s thickness with vernier callipers, to see if the dry film has an average thickness of 1 mm. This should be done in every 200 m2.over the entire roof. Once these tests are done, reapply Newcoat over these portions, in accordance with the Dr. Fixit Newcoat all as specified and directed
14M&L forPreparati of new Surface for treatment must be thoroughly cleaned of all laitance, loose material, oil, grease,etc. by mechanical means such as wire brushing. Treat any areas affected by Algae,moss or fungal growth with biocide wash solution. All surface cracks up to 5 mm width should be filled up with Dr. Fixit Crack-X.Cracks more than 5 mm and all separation gaps should be filled up with Dr. Fixit Pidicrete URP modifiedmortar or as specified. Pri ming saturated surface dry condition proceed for priming using Dr. Fixit Primeseal diluted in 2:1 ratio with water (2parts Primeseal diluted with 1 part water). Maintain the spreading rate of 8-10 sq mtr per litre for a single coat application to achieve about 20 – 25 microns DFT. Allow it to dry for 6-8 hrs.Applicat on Use Dr. Fixit Raincoat Waterproof Coating directly from the container. Stir contents well before use. and Apply one coats of Dr. Fixit Raincoat Waterproof Coating without dilution by brush or roller for rain lashing walls at the thickness of 120 – 130 microns all as specified and directed .
15M&L forPreparati of Existing substrates must be cleaned to remove all dirt, vegetation, plants, mildew and other contaminants. Treat any areasaffected by Algae, moss or fungal growth with biocide wash solution. This is accomplished by pressurecleaning equipment with a minimum capability of 100-140 bar water pressure. All grease, oils and asphalt materials must be removed completely.. All surface cracks up to 5 mm width should be filled up with Dr. Fixit Crack-X.Cracks more than 5 mm and all separation gaps should be filled up with Dr. Fixit Pidicrete URP modifiedmortar or as specified. Pri ming saturated surface dry condition proceed for priming using Dr. Fixit Primeseal diluted in 2:1 ratio with water (2parts Primeseal diluted with 1 part water). Maintain the spreading rate of 8-10 sq mtr per litre for a single coat application to achieve about 20 – 25 microns DFT. Allow it to dry for 6-8 hrs.Applicat on Use Dr. Fixit Raincoat Waterproof Coating directly from the container. Stir contents well before use. and Apply one coats of Dr. Fixit Raincoat Waterproof Coating without dilution by brush or roller for rain lashing walls at the thickness of 120 – 130 microns all as specified and directed .
16M&L for aplly a tack coat coat of bitumen 85 /25 at the rate of 1.20 Kg /Sqm on rooof surfaces including cleaning of surfaces in patches including sealing the open jointsin the water prooffelt including one coat solar reflective f aluminium painting @ .10 Lit per sqm on repaired portion complete all as as specified and directed
17M&L for PCC 1:2:4 type B1 (using 20mm graded aggregate) in copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating etc complete all as specified and asdirected.
18S&F pre- painted galvatume aluminum zinc coating GI based corrugated steelsheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
19S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
20Dismantling of wrought iron or mild steel work of any description not otherwise provided for all as specified and directed by Engr-in-charge
21S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running railsand guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410- W(Gde- E-250) quality-Ball as specified and as directed
22M&L for applying two coats of synthetic enamelled paint over a coat of red oxide on steel or iron surfacebased materials of any description , not other wise described over 10 cm width or girth including preparation of new surfaces.
23S&F for Framed brackets of angles or tees with web and flanges cut toshape, drilled and countersunk for screw, including bending andwelding angles, as necessary, gusset plates, riveting, etc.. n exc10 kg each brackets, conforming to Fe.290.Gde-E-165 (Bracketsover 10 kg each to be measured under "Structural Steel")all as specified and as directed
24S&F for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. Fe-410- W(Gde- E-250) quality- B(cut to ordinary lengths i.e. Within 20mm of the length indicated) all as specified and directed.
25Preparation of new steel surfaces and appying two coats ofblack bituminous paint all as specified and directed.
26Cutting holes into or through brick walls but in brick walls superficial area n.exc 150sqcm built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete. and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required
27Cutting holes into or through brick walls built in but in brick walls area exc 150 sqcm but n.exc 400 sqcm built in lime mortar and stone walls and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required
28Complete removal of existing roof treatment including vegetation and plantsany type and demolition of cement concrete padding at roof slab n exc 15cm thickness all specified and directed by Engr-in-Charge
29M & L for plain cement concrete 40mm thick average thickness as roof padding type B0, 1:2:4 (12.5mm graded aggregate) finished fair and even over concrete surface on roof top, and finished even and smooth with 10mm thick cement plaster in CM 1:4 mixed with WPC @ 200 ml per bag, when the concrete is green all as per manufacturer instructions ( Note: Water proofing compound will be paid under measured seperately)
30Supply only Liquid water proofing compoud
31Cleaning and preparation of newly plasteres roof surfaces and applying the water proofing treatment as under. (a)Applying 1st course of bituminious (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b)Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlapand 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane,(e)Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on roof surfaces complete all as specified and directed.
32Taking down of existing cemen or lime plaster along with the existing water proofing treatment including vegetation and plants on walls andapplying 10 mm thick cement plaster 1:3 mixed with liquid Water Proofing Compound @ 200 ml per bag, cleaning and preparation of newly plastered wall surfaces and applying the water proofing treatment as under.(a)Applying 1st course of bituminious (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b)Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlapand 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane,(e)Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on wall surfaces complete all as specified and directed.
33M & L for galvanised powder coated snap grid framework of size 605 x 605mm for false ceiling all as specified including vinyl laminated MPL gypsum panels ( GYPTECH) 9mm thick of size 60 x 60 cm fixing withstapples on snap grid by means of GI wires not less than 4mmdia hooks and raw plug etc centre of amke. GYPTECH/ARMSTRONG or equivalent all as directed by Engr-in-Charge
34M&L PCC Type B2 (1:2:4) using 40mm graded stone aggregates as in foundation, filling and mass concrete
35Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
36Disconnecting existingtanks, setting aside (orlowering if required) for repairs, cleaning, etc. andCleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. Capacity exc 250ltrs but n.exc 500ltrs complete all as specified and directed.
37All as per item 36.00 above but for exc 500 ltand not exc 1000 lt capacity
38All as per item 36.00 above butFor exc 1000 ltand not exc 2000 lt capacty
39S&F Galvanised steel water tubing medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed to walls/ceilings or laid in floors etc., complete including taking up (or) down the existing GI pipe completely all as specified for 15mm bore pipes.
40All as per item no 39.00 above but 20mm bore pipes
41All as per item no 39.00 above but 25mm bore pipes
42Refixing onlyGalvanised steel water tubing medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed to walls /ceilings or laid in floors etc., complete including taking up (or) down the existing GI pipe completely all as specified for 15mm bore of pipes.
43All as per item no 42.00 above but 20mm bore pipes
44All as per item no 42 above but 25mm bore pipes
45M & L Gun metal globe or gate valve with iron wheel head screwd both ends for iron pipe and fixed for 25 mm dia bore pipes fixed in repairs
46M & L Gun metal globe or gate valve with iron wheel head screwd both ends for iron pipe and fixed for 20 mm dia bore pipes fixed in repairs
47S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 1000 ltrs including dismantling of existing tank of any descriptionand S&F 20 mm ball PTMT Ball valve high pressure with exposy coated aluminum rod and high density plastic ball screwed for iron pipe.
48S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 500 ltrs including dismantling of existing tank of any descriptionand S&F 20 mm ball PTMT Ball valve high pressure with exposy coated aluminum rod and high density plastic ball screwed for iron pipe.
49PVC (SWR) pipes 110mmsingle socketed , in any length with rubber ringjoints ,fixed to walls /floor,spouts etc complete including dismantling existing pipes of any description all as specified anddirected.
50PVC (SWR) bends with oval access door 110mm fixed in repairs complete all as specified anddirected.