“Up-Gradation Of Mie Sivsagar Under Asidc Ltd For The Year 2023-24
Tender Value
2.56 Crore
Estimated cost
Bid Submission
17 Jan 2024
0 days left
EMD
5.13 Lakhs
Bank guarantee accepted
Document Fee
5500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sivasagar → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
“Up-Gradation Of Mie Sivsagar Under Asidc Ltd For The Year 2023-24
BOQ
| Sl. No. | Item Description |
| 1 | Civil Work |
| 2 | PILE WORK |
| 3 | Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of gradeM-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile tobe embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile |
| 4 | 400 mm dia piles |
| 5 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. |
| 6 | Note: 1. Initial and Routine Load Test shall not be carried out byDynamic method of testing. |
| 7 | Note: 2. Testing agency shall submit the design of loading platformfor the approval of Engineer-in-charge. |
| 8 | Single pile upto 50 tonne Safe capacity |
| 9 | Initial test (Test Load 2.5 times the Safecapacity) |
| 10 | Routine test (Test Load 1.5 times the Safecapacity) |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 12 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 13 | EARTHWORK |
| 14 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (not exceeding 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 15 | All kinds of Soil |
| 16 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials |
| 17 | All kinds of soil (From 1.5 - 3.0 m) |
| 18 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20 cmin depth, consolidating each deposited layer by ramming and watering, lead upto 50 meter and lift upto 1.5 meter. |
| 19 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 20 | Supplying & filling in plinth with Sand under floors, including watering, ramming, consolidating and dressing complete. |
| 21 | Supplying chemical emulsion in sealed container including delivery as specified. Chlorpyriphus / Lindane emulsifiable concentrate of 20% |
| 22 | Diluting and injecting chemical emulsion for Post constructional antitermite treatment (excluding the cost of chemical emulsion). |
| 23 | With Chlorpyriphus / Lindane emulsifiable concentrate of 20% with 1% concentration. |
| 24 | Along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 liter per lenear meter including drilling and plugging holes etc. |
| 25 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: |
| 26 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 27 | CONCRETE WORK |
| 28 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel : |
| 29 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from naturalsources : 8 graded stone aggregate 40 mm nominal sizederived from natural sources) |
| 30 | 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 31 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidatedandgroutedwithfinesandincluding finishingthetop smooth. |
| 32 | REINFORCED CEMENT CONCRETE |
| 33 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level : |
| 34 | :1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natura sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 35 | Reinforced cement concrete work in walls (any thickness), includingattach ed pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing andreinforcement : |
| 36 | :1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 37 | Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 38 | Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources). |
| 39 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 40 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 41 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level. |
| 42 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 43 | Centering and shuttering including strutting, propping etc and removalof forms of all heights. |
| 44 | Foundations, footings, bases of columns, etc for mass concrete. |
| 45 | Suspended floors, roofs, landings, balconies and access platforms. |
| 46 | Lintels, Beams, plinth beams , girders , bressumers, cantilevers. |
| 47 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 48 | Extrafor additionalheightin centering,shutteringwhere everrequiredwithadequatebracing,proppingetc., including costofde-shuttering anddecentering atall levels,overa heightof3.50meter foreveryadditional height of1meterorpartthereof(Planareatobe measured). |
| 49 | Suspendedfloors,roofs,landings,beamsandbalconies (Plan area to be measured). |
| 50 | MASONARY WORK |
| 51 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in: |
| 52 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 53 | Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level |
| 54 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 55 | Providing and placing in position 2 Nos. 6 mm dia M.S. bars at every third course of half brick masonry-the payment of RCC band and reinforcement shall be made for |
| 56 | Random rubble masonry with hard stone in foundation and plinth includinglevelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12graded stone aggregate 20 mm nominal size) upto plinth level with |
| 57 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 58 | FINISHING WORK |
| 59 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. |
| 60 | Providingand applyingplaster of putty 2mm thickness over the plastered surface to prepare the surface even and smooth complete |
| 61 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 62 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 63 | Applying priming coat: |
| 64 | With ready mixed red oxide zinc chromate primer ofapproved brand and manufacture on steel galvanised iron/ steel works |
| 65 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade |
| 66 | Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacture |
| 67 | FLOORING WORK |
| 68 | cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 69 | 40 mm thick with 20 mm nominal size stone aggregate |
| 70 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 71 | Size of Tile 600x600 mm |
| 72 | Glazed Vitrified tiles Matt/Antiskid finish of size 600 X1200 MM |
| 73 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 74 | Size of Tile 600x600 mm |
| 75 | Providingand fixing Ist quality ceramic glazed wall tiles conformingto IS : 15622 (6 to 7mm thick) of approved make in all colours, shades except burgundy, bottle green, black ofany sizeas approved by Engineer-in- Chargein skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing inwhitecement mixedwithpigment ofmatching shade complete. |
| 76 | Providing and laying Polished Granite stone flooring/ Riverwash (Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent) in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab colour of Black, Cherry/RubyRed or equivalent Polished Granite stone slab of all colour and texture exceptBlack, Cherry/Ruby Red |
| 77 | Providingandfixing18mmthickgangsawcut,mirror polished, remoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with whiteement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 78 | Granite of any colour and shade (Area of slabover 0.5 sqm. ) |
| 79 | Providing edge moulding to 18 mm thick marble stone counters, Vanitiesetc., including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-Charge.Granite work |
| 80 | Extra forfixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. |
| 81 | Extra for providing opening of required size & shape for wash basins / kitchen sink in kitchen platform, vanity counters and similar location in marble / stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. |
| 82 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. |
| 83 | Extra for pre finished nosing to treads of steps of Marble/Granite stone. |
| 84 | Providing and fixing Granite Stone of approved shade stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 85 | WOOD WORK & DOOR |
| 86 | Providing and fixing pressed steel door frames Profile B confirming to IS 4351, manufactured from commercial mild steel sheet of 1.60mm thickness,including hinges, jamb,lock,bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60mm,pressed mild steel welded or rigidity fixed together by mechanical means,including MS pressed butt hinges 2.5mm thick with mortar guards,lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre treatment of the the surface as directed by Engineer in charge.Fixing with adjustable lugs with split end tail toeach jamb |
| 87 | Providing and fixing 35 mm thick ISI marked flush door shutters including ISI marked Stainless Steel butt hinges with necessary screws conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 88 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 89 | 300x16 mm |
| 90 | 250x16 mm |
| 91 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete M-10 (Nominal Mix with 20 mm maximum size of stone aggregate) block 30x10x15 cm |
| 92 | Providingand fixing IS : 3564 markedAluminiumdie cast body tubular typeuniversalhydraulicdoorcloserwithnecessary accessories and screws etc. complete. |
| 93 | Providing and fixing 50cm long aluminium kicking plate 100x3.15 mm anodised (anodic coatingnot less than grade AC 10 as per IS:1868) transparentor dyed to requiredcolour or shade with necessary screws etc. complete. |
| 94 | 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. |
| 95 | ALLUMINIUM AND GLAZING WORK |
| 96 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular and other sections of approved makeconforming toIS:733andIS:1285,fixing with dash fasteners of required dia and size , including necessary filling up the gaps at junctions, ie at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling CP brass/stainless steel , all complete as per architectuural drawings and the directions of Engineer-in-charge.(Glazing andpanelling to be paid for separately) : |
| 97 | Anodised aluminium (anodised transparentor dyed to required shade according toIS: 1868, Minimum anodic coating of gradeAC 15) |
| 98 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) : |
| 99 | With float glass panes of 4.0 mm thickness (weight notless than 10kg/sqm) |
| 100 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 101 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width |
| 102 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-inchargePowder coated minimum thickness 50 micron aluminium |
| 103 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge |
| 104 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 105 | 250x10 mm |
| 106 | FABRICATION WORK |
| 107 | Providing and fixing M.S. grills Fixed to openings /wooden frames with rawl plugs screws etc of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete |
| 108 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 109 | RAILING WORK |
| 110 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 111 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strengthconforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 112 | 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 113 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 114 | 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 115 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approvedby Engineer-in-charge). |
| 116 | CHAINLINK FENCING |
| 117 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction ofEngineer-in-charge. |
| 118 | Made of G.I. wire of dia 4 mm |
| 119 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 120 | Sanitary Fixtures & CP Brass Fittings |
| 121 | Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal designcomplete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: |
| 122 | White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend. |
| 123 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders withunions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the wallsand floors wherever required : |
| 124 | Single half stall urinal with 5 litre P.V.C. automaticflushing cistern |
| 125 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- |
| 126 | (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 127 | Providing and fixing CP Brass 32 mm size bottle trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 128 | Providing and fixing CP Brass single lever telephonic wall mixer of quality & make as approved by Engineer-in-charge. |
| 129 | 15 mm Nominal dia. |
| 130 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 131 | Semi rigid pipe |
| 132 | 40 mm dia. |
| 133 | Providing and fixing 600x450 mm beveled edge mirror of superiorglass (of approved quality) complete with 6 mm thick hard boardground fixed to wooden cleats with C.P. brass screws and washerscomplete. |
| 134 | Providing and fixing toilet paper holder : |
| 135 | C.P. Brass |
| 136 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 137 | 100 mm diameter |
| 138 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 139 | 15 mm nominal bore |
| 140 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 141 | 15 mm nominal bore |
| 142 | Providing and fixing C.P. brass stop cock (consealed)of standard design and of approved make conforming to IS:8931 |
| 143 | 15 mm nominal bore |
| 144 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 145 | 15 mm nominal bore |
| 146 | Providing and fixing C.P. brass extention nipple (size 15 mm x 50 mm ) of approved make & quality as per direction of Engineer-in-Charge. |
| 147 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved qualityand colour, weighing not less than 105 gms. |
| 148 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms. |
| 149 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includesjointing of pipes & fittings with one step CPVC solvent cement ,trenching,refilling&testingofjointscomplete asperdirectionofEngineer in Charge |
| 150 | 40 mm nominal outer dia Pipes |
| 151 | Soil, Waste, Vent & Rain Water Pipes |
| 152 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 153 | 75 mm diameter |
| 154 | 110 mm diameter |
| 155 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 156 | Coupler |
| 157 | 75 mm |
| 158 | 110 mm |
| 159 | Bend 87.5° |
| 160 | 75 mm Bend |
| 161 | 110 mm Bend |
| 162 | Shoe (Plain) |
| 163 | 75 mm Shoe |
| 164 | 110 mm Shoe |
| 165 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 166 | Water Supply System |
| 167 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. |
| 168 | 25 mm nominal outer dia Pipes |
| 169 | 32 mm nominal outer dia Pipes |
| 170 | 40 mm nominal outer dia Pipes |
| 171 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. |
| 172 | Internal Work - Exposed on Wall |
| 173 | 20 mm dia nominal bore |
| 174 | 25 mm dia nominal bore |
| 175 | 32 mm dia nominal bore |
| 176 | Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) : |
| 177 | 25 mm nominal bore |
| 178 | 20 mm nominal bore |
| 179 | 32 mm nominal bore |
| 180 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 181 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. |
| 182 | All types of soil |
| 183 | 300 mm dia |
| 184 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of requireddia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. |
| 185 | 200 mm nominal size dia |
| 186 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs,conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction ofEngineer-in-charge. |
| 187 | 200 mm nominal size dia |
| 188 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 189 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \"V\" notch method or any otherapproved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested inapproved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 190 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: |
| 191 | 200 mm dia |
| 192 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. |
| 193 | 200 mm clamp |
| 194 | ELECTRICAL WORKS |
| 195 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 196 | Group A |
| 197 | Group B |
| 198 | Group C |
| 199 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required. |
| 200 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required. |
| 201 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 202 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 203 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 204 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 205 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 206 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 207 | Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 208 | 2 x 1.5 sq. mm |
| 209 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required. |
| 210 | 20 mm |
| 211 | 25 mm |
| 212 | 32 mm |
| 213 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 214 | 5/6 A switch |
| 215 | 3 pin 5/6 A socket outlet |
| 216 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 217 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 218 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 219 | 1 or 2 Module (75mmX75mm) |
| 220 | 4 Module (125mmX75mm) |
| 221 | 6 Module (200mmX75mm) |
| 222 | 8 Module (125mmX125mm) |
| 223 | 12 Module (200mmX150mm) |
| 224 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 225 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required. |
| 226 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 227 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 228 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 229 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 230 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 231 | Upto 450 mm sweep |
| 232 | Supplying and fixing of following ways surface/ recessmounting, vertical type, 415 V, TPN MCB distribution board ofsheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 233 | 12 way (4 + 36), Double door |
| 234 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 235 | Single pole |
| 236 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 237 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 238 | 63 A |
| 239 | Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 240 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brassnut bolt & spring washer spaced at 50mm) |
| 241 | FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL) |
| 242 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with |
| 243 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 244 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 10 Zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 set. Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required- 1 No.Gooseneck microphone with stand and ON/OFF switch- 1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free batteries -1 set. |
| 245 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 246 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 247 | Above 35 sq. mm and upto 95 sq. mm |
| 248 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 249 | 100 A, 16 KA,TPMCCB |
| 250 | 200 A, 25 KA,TPMCCB |
| 251 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 252 | 63 A |
| 253 | TOTAL COST OF ELECTRICAL WORKS DSR ITEM |
| 254 | Supplyingoffollowing type recessed / surface mounted LED light fixture complete with drivers, earthing point complete as required. (Havells or equivalent) |
| 255 | 1) 12W LED |
| 256 | 3) 20W LED bulb |
| 257 | Supplying of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. |
| 258 | High Speed 225 mm sweep(Havellsmake) |
| 259 | Havells-FLORIO Solar Post Top Light withinbuilt high efficency poly-crystalline solar module and maintenance free lithium battery with expected life of 1000 cycle and backup for three days and high efficiency long life LED housed in elegant looking die cast aluminium body with IP65 protection, pole length of 3.5 meter.(considering 15% discount on MRP) |
| 260 | Supply installation testing & commissioning of 2.5 HP Submersible pump with Steel wire rope |
| 261 | FIRE FIGHTING WORKS |
| 262 | FIRE PUMP WORKS FOR HYDRANTS & SPRINKLER SYSTEM |
| 263 | 1.NOC from fire authority shall be in the scope of Contractor . Only fee paid to the fire authority shall be reimbursed against the submission of the receipt and nothing shall be paid extra. |
| 264 | 2.All the Fire Fighting works shall be done in compliance of Fire Fightinga uthority requirement & relevant codes/standards. |
| 265 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) |
| 266 | Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 |
| 267 | Suitable HP squirell cage induction motor TEFC typesuitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. |
| 268 | M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. |
| 269 | Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 270 | 900 lpm at 35 m Head |
| 271 | PIPING & ACCESSORIES |
| 272 | Providing laying, testing & commissioning of \"C\" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. |
| 273 | 150 mm. Dia |
| 274 | Providing, laying, testing & commissioning of \"B\" class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 275 | 80 mm dia. |
| 276 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : |
| 277 | Single headed Stainless steel |
| 278 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts,washers, gaskets conforming to IS 13095 of following sizes as required : |
| 279 | 150 mm dia |
| 280 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 281 | 150 mm dia |
| 282 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : |
| 283 | Gun Metal |
| 284 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : |
| 285 | 4 way - 150 mm dia M.S. Pipe |
AI Tender Summary
Tender Timeline
Jan 02, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedJan 17, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 17, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents