| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-01-2024 | Commercial Corrigendum 1 | Date | 29-01-2024 |
| Sl. No. | Item Description |
| 1 | PART - I : CIVIL WORKS |
| 2 | Site clerance and earth Work |
| 3 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the Engineer In Charge outside the premises to any place within GA designated by the local authority from site by mechanical transport.Item also include cutting and removing of bushes /tress upto 30cm girth (to be measured at 1.0m above ground) etc. (Approval of location of disposal from local authority is in scope of contractor.) |
| 4 | All kinds of soil |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan but upto depth of 3.0m) including dewatering of both ground and surface water in all season, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, strutting required for keeping earth in position etc. and packing cavities (wherever required) including disposal of excess excavated earth and stacking of required excavated earth, for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the project manager outside the premises to any place designated by the local authority from site by mechanical transport. ( Approval of location of disposal from local authority to be in scope of contractor.) |
| 6 | All kinds of soil |
| 7 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan but upto depth of 3.0m) including dewatering of both ground and surface water in all season, removal of slurry generated while excavation and keeping the area free of water with necessary shoring, strutting required for keeping earth in position etc. and packing cavities (wherever required) including disposal of excess excavated earth and stacking of required excavated earth, for all leads and lifts, Excavated portion to be neatly rammed, leveled, dressed & compacted to receive bed concrete.Carting away excess excavated earth / debris as directed by the project manager outside the premises to any place designated by the local authority from site by mechanical transport. ( Approval of location of disposal from local authority to be in scope of contractor.) |
| 8 | Ordinary rock |
| 9 | Felling of trees of the girth (measured at a height 1 m above ground level ) including cutting of trunks and branches , removing the roots and stacking of serviceable materials and disposal unserviceable material. |
| 10 | a) beyond 30 cm Girthuptoand including60 cm girth |
| 11 | b) Beyond 60 cm girth upto and including 120 cm girth |
| 12 | c) Beyond 120 cm girth upto and including 240 cm girth |
| 13 | d) Beyond 240 cm girth |
| 14 | Earthwork in excavation and backfilling in layer of 200mm for foundations of buildings, basements, pipe supports, equipments as well as for manholes, plinth, tunnels, trenches for pipes & sewers & storm water drains, culverts etc., in ordinary and hard soils in both dry andwet conditions including pumping and bailing out surfaceand subsoil water (dewatering),shoring,strutting,slush removal at all heights and depths as per drawing and specifications wherever required , and backfilling in foundation pits and other places with excavated suitable surplus earth, including reclaiming from other soil heaps kept elsewhere and dressing and levelling,watering and mechanical compaction etc.,transporting surplus unserviceable soilto aplace within GA andspreading in layers as per specifications or heaping up to any heightsand as per the direction of Engineer Incharge. The Measurementforpayment shall be for the theoretical volume only i.e., the volume of the block ofthe excavation having maximum bottom dimension of thefoundation asper drawing.(Approval of location of disposal from local authority is in scope of contractor.) (The Contractor shall take into account in his rate the provision for excess excavation for necessary working space, slope etc., required for excavation and other allied works and refilling the side slopes and working space as mentioned in the specification). |
| 15 | For depth upto & including 1.50 m |
| 16 | For depth beyond 1.50 m and upto & including 3.00 m |
| 17 | Extra FOR disposal of surplus earth beyond initial lead of 50m upto 10 KM |
| 18 | Earth filling from available earth (excluding rock) under floors and other places with special compaction to achieve dry density of 95% standard proctor density including cost of excavation, reclaiming from soil heaps withinwork premises as per instruction of the EIC at all heights/depths, transporting, depositing, compacting and dressing, trimming complete as desired in layers not exceeding 15 cms including watering, consolidating by mechanical means as per specifications and instructions of the EIC. |
| 19 | a) With available good quality earth |
| 20 | Earth work in filling with good quality imported earth from approved source in the layers of 150 mm and compacted up to 95% to its MDDand any plan dimension including all testing, watering, rolling each layer with roller or wooden or steel rammers, and every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing / filling up ground depressions etc. complete in all respect as per scope of work, detailed construction drawings , as per technical specifications and directions of the Engineer-in-charge. |
| 21 | CEMENT CONCRETE |
| 22 | Supplying and laying plain cement concrete ofthe following proportions at all leads and lifts in all levelling courses under foundations, floors, pipelines, trenches, pits etc. using graded stone aggregate 20 mm max. size and down includingmechanical mixing, transporting,shuttering (if required) consolidation, finishing, curing etc. complete,as per specifications, drawings and instructions of the Engineer Incharge. |
| 23 | M-15 1:2:4 |
| 24 | M-10 1:3:6 |
| 25 | STEEL REINFORCEMENT |
| 26 | Supplying, fabricating and fixing in position TMT steel reinforcements of grade Fe 500at all levels and positions, all leads and lifts including the cost of transport, straightening, cutting, bending, cranking, binding, fixing, tying in position withannealed binding wire, welding provision of necessary chairs and spacers, including tying and bending dowel bars and their straightening upon deshuttering (wherever necessary) as per drawings and specifications and including cost of binding wire, labour, cover blocks in CM 1:2 etc., all complete for reinforced concrete as per specifications, drawings and instructions of the Engineer Incharge. |
| 27 | a) Reinforcement conforming to Grade Fe-500of IS : 1786-2008 ( TMT bars from SAIL /RINL/TATA STEEL/JSW ) |
| 28 | NOTE: 1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as steel Reinforcement, binding wire and other minor construction materials, testing etc.all bye works and sundry works. 2. Chairs, Laps, Spacers, Wastage etc. shall be to contractor\"s account. |
| 29 | Supplying and Laying of design mix,Reinforced Cement Concrete of following Gradesat all depths and heights in all types of Foundations, Footings,equipment foundations,columns, pedestal,wall, lintels, ducts, beams, brackets, slabs of all shapes, sills, parapets,bandsandany otherworks both in sub andSuperstructures allcomplete with all bye works as perDrawings, Specification and instruction of Engineer. (The rates shall include the cost ofnecessary shuttering but excluding the cost of steel reinforcement) |
| 30 | M-25 Grade Design Mix Concrete using ordinary portland cement (20 mm down graded coarse aggregate.) UPTO PLINTH LEVEL |
| 31 | M-25 Grade Design Mix Concrete using ordinary portland cement (20 mm down graded coarse aggregate.) ABOVE PLINTH LEVEL |
| 32 | NOTE:1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade OPC cement, other minor construction materials, shuttering , staging, removal of form work, testing of concrete, curing etc. except reinforcement steel with all bye works and sundry works complete. 2. Mix deisgn shall be prepared confirming to relevant IS Codes ( IS 10262, SP.23 & IS 456 Latest Codes) from NABL approved lab and the same shall be approved by EIC. |
| 33 | Providing, constructing and finishing of compound wall in RCC frame structurewith precast RCC wall panels of 100mm thickness mounted on in-situ RCC columns of400mmx450mm size at an interval of 3.0 m or as specified in construction drawing and height 2m as specified as per scope of work , including plastering, coping, painting, whitewash,concertina coil, embossing of logo of the client, on all columns, finishes all complete as per technical specifications, tender drawing and direction of the Engineer-In-Charge. |
| 34 | NOTE: 1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade OPC cement, pre cast wall panels ,ISMC channel section,hard drawn steel wire fabric as per IS 1566 ,RCC M25, concertina coil, RBT , finishes, bitumen, Y angle, other minor construction materials, shuttering, staging, coping, expansion gap filling with \"Capcell\" armoured board of \"Supreme\" make or equivalentand white sealant material,plastering,painting and all other sundry works.2. Foundation/ sub-structure to bepaid separately in respective SOR items.3.Reinforcement for columns and beam for superstructure shall be paid separately in respective SOR Item. |
| 35 | Supplying & grouting for Foundations bolt holes/pockets for Equipments, Base plates,Anchoring etc, with cement based non shrink compound such as Shrinkomp of ACC or approved make of FOSROC/SIKA/ROFFincluding shuttering at all levels and as per drawings, specification and direction of Engineer in charge. |
| 36 | Providing and laying roof screed with M-15 grade concrete (12 mm down graded coarse aggregate) at all leads and lifts with wooden trowel finish and required slope including mixing of water proofing compound as per manufacturer\"s specification, curing etc. , as per drawings and direction of Engineer Incharge. |
| 37 | CC BLOCK work |
| 38 | Providing and layingcement blocks (solid blocks) masonry mix ratio of 1 :1.5:3 with 200 mm thick blocks upto plinth level and super structure above plinth level up to top level of building in cement mortar 1:3 (1 cement : 3 coarse sand ). |
| 39 | Upto Plinth level |
| 40 | Above plinthlevel |
| 41 | Brick work with bricks of class designationM 7.5 Grade with Mortar 1:6 (1Cement: 6 Coarse sand) in all levels. |
| 42 | Providing and fixing 100mm thick M-25 factory made RCC drain/trench cover including cost of shuttering and minimum reinforement@ 10mm dia TMT Fe-500bars @100mm c/c bothway in two layers as per direction of Engineer In Charge.The RCC cover shall have edge protection with 100mm wide 1.6mm thick MS sheet all around alongwith 2 nos 12 mm dia bar for hook etc complete including painting of MS sheet. |
| 43 | Providing and fixing 150mm thick M-25 Pre cast RCC drain/trench cover including cost of shuttering as per drawing and direction of Engineer In Charge. The RCC cover shall have edge protection with 150mm wide 1.6mm thick MS sheet all around alongwith 2 nos 16 mm dia bar for hook etc complete including painting of MS sheet. Reinforcement shall be paid in respective SOR Item. |
| 44 | Providing and laying R.C.C.(M25 Grade concrete) vacuum dewatering concrete flooring with floor hardener of approved make to be sprinkeled at the rate of 5 kg/sqm before mechanical troweeling as per manufacturer\"s specifications including mixing, tamping mechanically, consolidating, leveling cement concrete of grade M25 in grade slab, 200/150 thick including suction drying, mechanical trowelling (power float) and finishing, curing, cutting expansion grooves and filling expansion grooves with polysulphide joint fillers complete as specified and directed includingshuttering but excluding reinforcement, including doweled construction joints as per drawings. |
| 45 | FINISHING |
| 46 | 12 mm cement internalplaster on walls of all heights at all levels in perfect line and level |
| 47 | 18 mm external cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:5 (1 cement : 5 fine sand) for all heights and levels in perfect line and level |
| 48 | Painting with APEX/Wheathershield make exterior paint with one coat of primer and two or morecoat of approved paint on new work wherever required to achieveeven shade and colour for all heights and levels. |
| 49 | Providing and laying paving of pre cast concreteinterlocking pavers made of M30 grade concrete of 80 mm thickness of approved colour combination, pattern make, size, of compressive strength 300KG /sq cm. Paver blocks should be laid onsand cushion as required with a gap of 1.5mm between the blocks filled with sand including paving and curb gap to be filled with concrete of same grade of concrete pavers |
| 50 | DISMANTLING/DEMOLISHING |
| 51 | Demolishing of Cement Concrete (PCC) of all grades manually/mechanical means including disposal of debris as directed by the Engineer. Debris shall be disposed outside the site and this shall be entirly Contractor\"s responsibility irrespective of any Lead. |
| 52 | Demolishing ofRCC of all grades manually/ mechanical means including disposal of debris as directed by the Engineer. Debris shall be disposed outside the site and this shall be entirly Contractor\"s responsibility irrespective of any Lead. |
| 53 | PART II-ELECTRICAL WORKS |
| 54 | Supply of 63kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender specifcation. Transformer shall be as per SEB approved make.(Star rating / Efficiency class of transformer shall be as per SEB standard during execution). |
| 55 | Supply of 25kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender specifcation. Transformer shall be as per SEB approved make.(Star rating / Efficiency class of transformer shall be as per SEB standard during execution). |
| 56 | Supply of 11kV double pole structure with 9 mtr RCC poles including cross bracing’s of ISMC ,GOS with earth switch, polymeric type LA’s & pin insulator, HG fuses, ACSR conductor, stay sets, earthing, alkathine tube etc. as per the specification including civil works. Make of all components shall be as per SEB approved make. |
| 57 | Design, engineering, manufacture, shop testing, supply includingpacking and forwarding, transportation, delivery at storage and from storage to site of power distribution board (PDB) : |
| 58 | 415 V, 36 KA single front type indoor PDB to receive input power consisting ofbus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/U999/05/E9/E/1081A & as per standard Specification.Single In-comer of 125 Amp(with Single phase preventer ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) along with VMR.Outgoing with 01 no. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for Booster Compressor.Outgoing with 01 no. 63 Amp TPN MCCB(with TM based O/C,S/C & E/F RELASE) for APFC panel.Outgoing with 02 nos. 32 Amp TPN MCCB(with TM based O/C, S/C & E/FRELASE) for UPS and Static Bypass.Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCBwithout Timer |
| 59 | 415 V, 36 KA single front type indoor PDB to receive input power consisting ofbus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/U999/05/E9/E/1081B & as per standard Specification .Single In-comer 100A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.Outgoing with 3 nos. 63 Amp TPN MCCB(with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of Engine driven compressor like Exhaust fan/ lighting, etcii) Air Compressor iii) APFC PanelOutgoing with 2 nos. 32 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for UPS and Static Bypass.Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCBwithout Timer |
| 60 | 415 V, 36 KA single front type indoor PDB to receive input power consisting ofbus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/U999/05/E9/E/1081C & as per standard Specification .Single In-comer 63 (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.Outgoing with 2 nos. 32 Amp TPN MCCB(with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of DCU Unitii)SpareOutgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCBwithout Timer |
| 61 | Floor mounted APFC Panel of 10KVAR capacitor bank in steps of 4x2.5 KVAR capacitors consisting of bus bar chamber, cable alley incoming (FSU), outgoing feeder (FSUs) as specified in tender specification |
| 62 | Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 4 Pole and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgoing terminals, with RYB indication. |
| 63 | Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 63A, 415V, 4 Pole and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgoing terminals, with RYB indication. |
| 64 | Supply includingpacking and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box/ Junction Box ,glands ,lugs as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects. |
| 65 | Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/ Junction box (Model no. FLPW-1095 of Baliga make or equivalent) |
| 66 | Supply of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire (Baliga make or equivalent) |
| 67 | Supply of Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing & specification. |
| 68 | Design, engineering,supply includingpacking and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043. |
| 69 | Earth Pits- GI PIPE Electrode(3.0m long, 65 NB dia.) with 6 mm thick chequered plate cover |
| 70 | Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover |
| 71 | GI Strip (50X6) mm |
| 72 | GI Strip (25X3) mm |
| 73 | Arrangement for Earthing of LCV with Flexible green Cu wire (25 sqmm of approx 30 Meter length) ,Clamp (includingbolting arrangement) ,Flexible PVC, crcodile clamps(2 nos.each) and other item etc. including MS enclosure box with door of sheet thk (2.00mm) color etc. |
| 74 | Design, engineering,supply includingpacking and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) including Cable glands & Lugs etc.of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc. |
| 75 | 3.5x 120 mm2 A2XFY |
| 76 | 3.5x 95 mm2 A2XFY |
| 77 | 3.5x 50 mm2 A2XFY |
| 78 | 4x 25 mm2 A2XFY |
| 79 | 4x10 mm2 2XWY |
| 80 | 4x 6 mm2 2XWY |
| 81 | 4x 2.5 mm2 2XWY |
| 82 | Supply of following sizes of HDPE Pipe |
| 83 | 50 mm NB |
| 84 | 80 mm NB |
| 85 | 100 mm NB |
| 86 | 150 mm NB |
| 87 | Supply of point wiring as per details in construction drawing & specificationincludesPVC conduits in ceiling, complete wiring including flexible wire (FR PVC), switch boxes & switches (ANCHOR ROMA make or equivalent), Multi strand Flexible HR PVC insulated copper conductor wires/cables for following items- |
| 88 | Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-36-FO-CDL - 2 X 2 ft of CG make or equivalent). |
| 89 | Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-18-FO-CDL - 2 X 2 ft of CG make or equivalent). |
| 90 | Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap. |
| 91 | Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent |
| 92 | 20 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC. |
| 93 | Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep) |
| 94 | Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting |
| 95 | Supplyoffollowingincludingnecessary clamp, bolts, rawl plugs etc. |
| 96 | Shock hazard charts |
| 97 | First Aid Boxes |
| 98 | Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark, Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate. |
| 99 | Cautionboards |
| 100 | Single Line Diagram in teak wood wall cabinet with glass door |
| 101 | Wooden key box with glass cover |
| 102 | Supply of 1.1kV grade insulated mats required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per IS 15652and Indian Electricity Rules. |
| 103 | Supply of 150mm GI ladder type cable tray along with all accessories etc. |
| 104 | Supply of 2 Coats of Primer Painted & Fabricated support structure. |
| 105 | UPS SYSTEM |
| 106 | Design, engineering, manufacture, shop testing, supply,packing and forwarding, transportation, delivery at storage ,inspection, packing, forwarding, delivery including commissioning spares as required of UPS systems as per specification, block diagram and following rating: |
| 107 | 3KVA, 230 V Single phase, 50 Hz, single industrial type, UPS system suitable for input Power supply voltage of 320V-460V-TPN with healthy single-Phase Selection, Output 230V +/-1%, AC with Bypass supply, Battery Bank, and 2.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 13.0 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). As per enclosed Specification, Block diagram & Data sheet and shall be complete in all respect. Including All interconnecting cables among UPS, Rectifier, battery stand, ACDB etc (30 mtr shall be considered between battery bank and UPS panel, 30 mtr cable shall be considered between ACDB and UPS panel. |
| 108 | 230 V, 10 KA single front type indoor wall mounted ACDB to receive input from UPS consisting of Incomer 32A DP MCB & Outgoing 10 Nos. 6A to 10A DP MCB, complete with wiring, indication lamp, ammeter, voltmeter etc including all labour and materials with operating mechanism & all accessories. |
| 109 | Erection Material |
| 110 | Supply of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, supply of necessary anchor bolts and grouting etc supply of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including supply of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge. |
| 111 | For RO/DBS/DCU |
| 112 | Supply of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge. |
| 113 | For RO/DBS/DCU |
| 114 | Supply of required material for construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge. |
| 115 | 500X500(of inside clearance)X 600(Depth) |
| 116 | 750X750(of inside clearance)X800(Depth) |
| 117 | 1000X1000(of inside clearance)X1000(Depth) |
| 118 | Installation, Testing and Commissioning of 63kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender specifcation. Transformer shall be as per SEB approved make.(Star rating / Efficiency class of transformer shall be as per SEB standard during execution). |
| 119 | Installation, Testing and Commissioning of 25kVA, 11/0.433kV Outdoor type, 3 Ph, 50Hz, Cu wound, Dyn11,ONAN Distribution Transformer complete with all accessories and first oil filled as per tender specifcation. Transformer shall be as per SEB approved make.(Star rating / Efficiency class of transformer shall be as per SEB standard during execution). |
| 120 | Installation, Testing and Commissioning of 11kV double pole structure with 9 mtr RCC poles including cross bracing’s of ISMC ,GOS with earth switch, polymeric type LA’s & pin insulator, HG fuses, ACSR conductor, stay sets, earthing, alkathine tube etc. as per the specification including civil works. Make of all components shall be as per SEB approved make. |
| 121 | STATUTORY APPROVALS, PERMISSIONS : Coordination & Liasioning with statutory authorities for obtaining Licence/NOC/ Approval /Permission with statutory authorities for GAIL Gas as required for setting of CNG stations .However, all the statutory payment required for such Licence/NOC/ Approval /Permission shall be reimbursed by GGL at actuals against production of documentary evidence and this statutory payment at actuals shall be over and above the coordination and liasioning charges quoted in the items below.The bidder shall note that the quoted rates for the items shall be inclusive of all expenses (except for statutory payments which shall be reimbursed on actuals) for carrying out the liasioning and coordination work till obtaining the final Licence/NOC/ Approval /Permission.To submit application on behalf of Gail gas to SEB for the incoming power Installation, Testing and Commissioning along with all the required documents, obtaining NOC from SEB for final charging, obtaining drawing approval from CEIG before commencemnt of work and obtaining safety & comissionming approval of Transformer by CEIG and SEB.The price shall be inclusive of Application Fee,liaisioning, Local Transport, Incidental travelling etc, and all other expenses. |
| 122 | Installation, Testing and Commissioning of Switchboards |
| 123 | Design, engineering, manufacture, shop testing, Installation, Testing and Commissioning includingpacking and forwarding, transportation, delivery at storage and from storage to site of power distribution board (PDB) : |
| 124 | 415 V, 36 KA single front type indoor PDB to receive input power consisting ofbus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/U999/05/E9/E/1081A & as per standard Specification.Single In-comer of 125 Amp(with Single phase preventer ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) along with VMR.Outgoing with 01 no. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for Booster Compressor.Outgoing with 01 no. 63 Amp TPN MCCB(with TM based O/C,S/C & E/F RELASE) for APFC panel.Outgoing with 02 nos. 32 Amp TPN MCCB(with TM based O/C, S/C & E/FRELASE) for UPS and Static Bypass.Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCBwithout Timer |
| 125 | 415 V, 36 KA single front type indoor PDB to receive input power consisting ofbus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/U999/05/E9/E/1081B & as per standard Specification .Single In-comer 100A (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.Outgoing with 3 nos. 63 Amp TPN MCCB(with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of Engine driven compressor like Exhaust fan/ lighting, etcii) Air Compressor iii) APFC PanelOutgoing with 2 nos. 32 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE) for UPS and Static Bypass.Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCBwithout Timer |
| 126 | 415 V, 36 KA single front type indoor PDB to receive input power consisting ofbus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/U999/05/E9/E/1081C & as per standard Specification .Single In-comer 63 (with Single phase Protection ) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) etc as required along with VMR.Outgoing with 2 nos. 32 Amp 4 pole MCCB(with TM based O/C,S/C & E/F RELASE) for i)Auxiliaries of DCU Unit ii)SpareOutgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual Outgoing with 3 no. 40A Fuse and 3 nos. 10A DP MCBwithout Timer |
| 127 | Floor mounted APFC Panel of 10KVAR capacitor bank in steps of 4x2.5 KVAR capacitors consisting of bus bar chamber, cable alley incoming (FSU), outgoing feeder (FSUs) as specified in tender specification |
| 128 | Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 4 Pole and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgoing terminals, with RYB indication. |
| 129 | Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 63A, 415V, 4 Pole and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgoing terminals, with RYB indication. |
| 130 | Installation, Testing and Commissioning includingpacking and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box/ Junction Box ,glands ,lugs as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects. |
| 131 | Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/ Junction box (Model no. FLPW-1095 of Baliga make or equivalent) |
| 132 | Installation, Testing and Commissioning of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire (Baliga make or equivalent) |
| 133 | Installation, Testing and Commissioning of Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing & specification. |
| 134 | Installation, Testing and Commissioning includingpacking and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043. |
| 135 | Earth Pits- GI PIPE Electrode(3.0m long, 65 NB dia.) with 6 mm thick chequered plate cover |
| 136 | Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover |
| 137 | GI Strip (50X6) mm |
| 138 | GI Strip (25X3) mm |
| 139 | Arrangement for Earthing of LCV with Flexible green Cu wire (25 sqmm of approx 30 Meter length) ,Clamp (includingbolting arrangement) ,Flexible PVC, crcodile clamps(2 nos.each) and other item etc. including MS enclosure box with door of sheet thk (2.00mm) color etc. |
| 140 | Installation, Testing and Commissioning, Laying includingpacking and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) including Cable glands & Lugs etc.of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc. |
| 141 | 3.5x 120 mm2 A2XFY |
| 142 | 3.5x 95 mm2 A2XFY |
| 143 | 3.5x 50 mm2 A2XFY |
| 144 | 4x 25 mm2 A2XFY |
| 145 | 4x10 mm2 2XWY |
| 146 | 4x 6 mm2 2XWY |
| 147 | 4x 2.5 mm2 2XWY |
| 148 | Installation, Testing and Commissioning of following sizes of HDPE Pipe |
| 149 | 50 mm NB |
| 150 | 80 mm NB |
| 151 | 100 mm NB |
| 152 | 150 mm NB |
| 153 | Installation, Testing and Commissioning of point wiring as per details in construction drawing & specificationincludesPVC conduits in ceiling, complete wiring including flexible wire (FR PVC), switch boxes & switches (ANCHOR ROMA make or equivalent), Multi strand Flexible HR PVC insulated copper conductor wires/cables for following items- |
| 154 | Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-36-FO-CDL - 2 X 2 ft of CG make or equivalent). |
| 155 | Surface/ recess mounted LED light fixrure with LED lamp (type LCTLRN-18-FO-CDL - 2 X 2 ft of CG make or equivalent). |
| 156 | Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap. |
| 157 | Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent |
| 158 | 20 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC. |
| 159 | Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep) |
| 160 | Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting |
| 161 | Installation, Testing and Commissioningoffollowingincludingnecessary clamp, bolts, rawl plugs etc. |
| 162 | Shock hazard charts |
| 163 | First Aid Boxes |
| 164 | Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark, Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate. |
| 165 | Cautionboards |
| 166 | Single Line Diagram in teak wood wall cabinet with glass door |
| 167 | Wooden key box with glass cover |
| 168 | Installation and laying of 1.1kV grade insulated mats required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per IS 15652and Indian Electricity Rules. |
| 169 | Installation, Testing and Commissioning of 150mm GI ladder type cable tray along with all accessories etc. |
| 170 | Painting work of 2 Coats of Primer Painted & Fabricated support structure. |
| 171 | UPS SYSTEM |
| 172 | Installation, Testing and Commissioning, packing, forwarding, delivery by equipment supplier at site including commissioning spares as requiredof UPS systems as per specification, datasheet, block diagram of the following rating : |
| 173 | 3KVA, 230 V Single phase, 50 Hz, single industrial type, UPS system suitable for input Power supply voltage of 320V-460V-TPN with healthy single-Phase Selection, Output 230V +/-1%, AC with Bypass supply, Battery Bank, and 2.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 13.0 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). As per enclosed Specification, Block diagram & Data sheet and shall be complete in all respect. Including All interconnecting cables among UPS, Rectifier, battery stand, ACDB etc (30 mtr shall be considered between battery bank and UPS panel, 30 mtr cable shall be considered between ACDB and UPS panel. |
| 174 | 230 V, 10 KA single front type indoor wall mounted ACDB to receive input from UPS consisting of Incomer 32A DP MCB & Outgoing 10 Nos. 6A to 10A DP MCB, complete with wiring, indication lamp, ammeter, voltmeter etc including all labour and materials with operating mechanism & all accessories. |
| 175 | Erection Material |
| 176 | Installation,welding and Commissioning of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, Installation, Testing and Commissioning of necessary anchor bolts and grouting etc Installation, Testing and Commissioning of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including Installation, Testing and Commissioning of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge. |
| 177 | For RO/DBS/DCU |
| 178 | Installation, Termination and Commissioning of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge. |
| 179 | For RO/DBS/DCU |
| 180 | Civil Constructionof required material for the construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge. |
| 181 | 500X500(of inside clearance)X 600(Depth) |
| 182 | 750X750(of inside clearance)X800(Depth) |
| 183 | 1000X1000(of inside clearance)X1000(Depth) |
| 184 | PART - III : Mechanical &Tubing Works |
| 185 | SECTION-A : SS TUBE LAYING & TESTING |
| 186 | Supply and Erection of SS TUBES with PVCtube clamp,Pneumatic testing with Nitrogen at 280 bar and commissioning of SS tubes along with fittings, hose, mass flow meter and valves as given below and as per Technical Specification and scope of work including handling, lifting, transportation from stores tolocation of CNG stations. |
| 187 | 1”OD X 0.120” min Wall thk.SS Tube |
| 188 | ¾”OD X 0.095” min Wall thk.SS Tube |
| 189 | ½”OD X 0.083” min Wall thk.SS Tube |
| 190 | Supply of SS Fittings |
| 191 | Union |
| 192 | Size : 1\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 193 | Size : ¾” OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 194 | Size : ½\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 195 | Reducing Union |
| 196 | Tube OD 3/4\" x Tube OD 1/2\", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 197 | Tube OD 1\" x Tube OD ¾\", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 198 | Equal Tee |
| 199 | Size:1\" OD x 1\" OD x 1\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 200 | Size:3/4\" OD x 3/4\" OD x 3/4\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 201 | Nut |
| 202 | ¾ \" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 203 | ½\" OD, Material : SS316(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 204 | 1\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 205 | Front Ferrule |
| 206 | 3/4\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 207 | ½\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 208 | 1\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 209 | Back Ferrule |
| 210 | 3/4\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 211 | ½\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 212 | 1\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 213 | Plug |
| 214 | Size : ¾\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 215 | Size : 1\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 216 | Cap |
| 217 | Size : ¾\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 218 | Size : 1\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 219 | Cross |
| 220 | 3/4\" OD X 3/4”X 3/4\" OD X3/4\" OD Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 221 | Supply of SS Ball Valvesconforming to MECON’s Technical Specification No. MEC/TS/05/62/048 for SS Ball Valves of following sizes, specifications as indicated below : |
| 222 | 2-Way Floating Normal Bore Ball Valve ¾\" |
| 223 | 3-Way Trunnion Mounted, Reducer BoreBall Valve ½\" OD end Connection and ¼” NPT (F) bottom end connection |
| 224 | SUPPLY OF HIGH PRESSURE CNG HOSE ASSEMBLY (CONDUCTIVE CORE THERMOPLASTIC HOSE ASSEMBLY) |
| 225 | Design, Manufacture, testing, Loading , Supply,Transportation & Unloading at GGL stores of 1/2” ID Conductive Core Thermoplastic Hose of 5.0m length for CNG Service with break away couplingalong with Quick connect body & stem (End connection:½\" Tube OD for stem & ½”NPT (F) for body, Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F) .One end of the hose shall be 1/4\" NPT(M) and other end of the hose shall be 3/4\" OD.Supply and assembling of all necessary fittings with the hose for making the end conncetions as indicated above are in the scope of contractor. |
| 226 | SECTION-B : ERECTION OF MECH. EQUIPMENT |
| 227 | Handling (including lifting and transportation from Client\"s store within GA toCNG stations)and erecting in position, the following equipmenteither on the foundation oron roof at ~ 3 to 4 m above ground level.Contractor\"s scopeincludes supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc.. Scope also includes supply of all lifting tools / necessary accessories and hiring of cranes for same. |
| 228 | Type-I; Cascade 4500/3000 water capacity. Erection at + 3 to 4.0 M level |
| 229 | Type-IV; Cascade 8800 Water capapcity, Erection at 0.0 level |
| 230 | Decompression unit-The item also includes supervision of OEM required for installation and commissioning of the equipment at station. |
| 231 | DISMANTLING,SHIFTING , RE-INSTALLATION & COMMISSIONING OF CNG Decompression unit and Conversion of DBS to Online |
| 232 | Dismantling,disconnecting cables,earthing, SS tube,pipe, removal of Decompression unit/Daughter Booster Compressor along with related accessoriesfrom one Station within GA and shifting/transportation including loading, unloading and then installation, erection, testing and commissioning of same equipment along with accessories, cablesatother station within GANote: The above item also includesbreaking/dismantling of foundation if required, supply of pipes/cables ,pipe fittings, foundation bolts, supervision of OEM required for installation and commissioning of the equipment at otherstation. |
| 233 | Note:The quantities given above against individual items are indicative and shall not be considered to be binding.The quantities may increase or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge.The unit rate shall be operated to work out the final payment due to Contractor. |
| 234 | Handling including lifting and transportation of dispenser framefrom Client\"s store within city toCNG stations. |
| 235 | SECTION-C : SUPPLY, ERECTION & COMMISSIONING OF MISCELLANEOUS ITEMS |
| 236 | Supply, erection & commissioning of following miscellaneous items as per technical specification and at locations (within the stations) as directed by EIC |
| 237 | Fire fighting Equipments |
| 238 | Stored Pressure Type DCP -9 Kg confirming to IS 15683 and as per TS |
| 239 | DCP -75 Kg confirming to IS 10658 and as per TS |
| 240 | CO2 – 4.5 Kg confirming to IS 15683 and as per TS |
| 241 | Sand Bucket Stand with 4 Nos. Bucket and as per TS |
| 242 | Design, manufacture, assembly,testing & supplyas well as installation, testing and commissioning of LCV Filling post consisting ofthe following.-4” Pressure Gauge for pressure monitoring of CNG,-1/2” ID Conductive Core Thermoplastic Hose of 5.0m length for CNG Service with break away couplingalong with Quick connect body & stem (End connection:½\" Tube OD for stem & ½”NPT (F) for body, Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F) .One end of the hose shall be 1/4\" NPT(M) and other end of the hose shall be 3/4\" OD.Supply and assembling of all necessary fittings with the hose for making the end conncetions as indicated above are in the scope of contractor.-3-Way Trunnion Mounted, Reducer BoreBall Valve ½\" OD end Connection and ¼” NPT (F) bottom end connection-2-Way Floating Normal Bore Ball Valve ¾\"-Necessary SS tubing of sizes 3/4\"OD and 1/2\"OD, tube fittings-Vent tube -Required Structural frame and tube supports shall be payable through Structural SOR |
| 243 | PART IV :STEEL STRUCTURAL WORKS |
| 244 | Structure Steel Works for Miscellaneous Structures like Grating , Handrails , Hoardings etc |
| 245 | Supplying, Fabricating & Erecting in position steel structures fabricated out of MS Girders, channels, Tees, angle, flats, plate, square hollow sections pipes etc. conforming to IS:2062 and/or from pipes conforming to IS:1161 for structural purpose for cascade supporting structure, loading/unloading platform, Gratings for platform, catladder,handrails, hoardings for sinages,Lcv stand, etc. of any size/dia for required design including cutting, welding, bolting,hoisting, fixing in position, including application of one coat of primer at shop and second coat of primer at site after erection and two coats of finishing paint at site .The work is to be completed in all respect as per specification ,scope of work,detailed construction drawings and directions of the Engineer-in-charge.[ Rate to include cost of all labour, nut, bolts, tools, tackles, hire charges royalties, levies, transportation, scrap value, gas cutting, welding, other consumables,paints, compressed air, water, electric power etc. all complete.] |
| 246 | Providing and fixing Fencing Gates |
| 247 | Supplying, fabricating & fixing fencing gates fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, painting with enamel paint in approved shade including supply of all raw materials, bolts, electrodes, transportation etc complete as per enclosed sketch, technical specifications and directions of the Engineer-In-Charge. |
| 248 | 4m Wide x 2.1m High |
| 249 | 2m Wide x 2.1m High |
| 250 | Providing and Fixing 6 O/P Chequered Plate Covers |
| 251 | Providing and fixing chequered plate in approved panel or over steel structure including cutting, welding, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel over a priming coat of approved steel primer etc complete as per scope detailed drawings , technical specifications and directions of the Engineer-In-Charge.[ Rate to include cost of all labour, nut, bolts, stiffening sections, bars tools, tackles, hire charges, royalties, levies, transportation, scrap value, gas cutting, welding, other consumables, paints, compressed air, water, electric power etc. all complete.] |
| 252 | TotalExcluding GST |
| 253 | GST (CGST&SGST/UTGST or IGST) in percentage (%) on Total(Presently applicable @ 18%) |