Himachal Pradesh State Electricity Board-HPSEB has published E-Tender For Replacement Of Damaged Clamps And Repair Of 220Kvisolator And Inveter At 220/132/33Kv Sub-Station At Girinagar.. Submission Date for this Tender is 05-01-2024. Fuses Tenders in Sirmaur Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | O/M of 220kV Substation Giri Nagar |
2 | Replacement of damaged/wornout/hotspot bearing33 kV CT Clamps with new clamps made of heavy duty aluminuim alloy bolted with galvanished steel parts, Zordar/Anushree make, suitable for ACSR Zebra conductor to be mounted and CT primary terminal as per the sample complete in all respectsas per the direction of Engineer in Charge at 220/132/33kV Substation Giri Nagar |
3 | Replacement of damaged/wornout/hotspot bearing33 kV IsolatorClamps with new clamps made of heavy duty aluminuim alloy bolted with galvanished steel parts,Zordar/Anushree make, suitable for ACSR Zebra conductor33 kV isolatorend as per the sample complete in all respects as per the direction of Engineer in Charge. at 220/132/33kV Substation Giri Nagar |
4 | Replacement of damaged/wornout/hotspot bearing33 kV Incomer IsolatorClamps with new clamps made of heavy duty aluminuim alloy bolted with galvanished steel parts,Zordar/Anushree make, suitable for ACSR Zebra conductor33 kV Incomer Isolatorend as per the sample complete in all respects as per the direction of Engineer in Charge. at 220/132/33kV Substation Giri Nagar |
5 | Replacement of damaged/wornout/hotspot bearing 33 kV Female Isolator clamps with new clamps made of heavy dutyaluminium alloy with copper strips to be mounted and bolted on 33 kVisolator as per the sample complete in all respects as per the direction of Engineer in Charge at 220/132/33kV Substation Giri Nagar |
6 | Replacement of damaged/wornout/hotspot bearing 132 kV Bus Isolator femaleclamps with new clamps made of heavy duty aluminuim alloy with copper strips & bolted with galvanished steel partsto be mounted and bolted on 132 kV Bus isolatorend as per the sample complete in all respects as per the direction of Engineer in Charge at 220/132/33kV Substation Giri Nagar |
7 | Replacement of damaged/wornout/hotspot bearing 132 kV T-clamp made with new T-clamps made of heavy duty aluminuim alloy & bolted with galvanished steel parts, Zordar/Anushree make, suitable for ACSR Goat conductor to beboltedbetween 132 kV Bus A to Bus B isolator as per the sample complete in all respects as per the direction of Engineer in Charge at 220/132/33kV Substation Giri Nagar |
8 | Replacement of damaged/wornout/hotspot bearing 132 kV PG clamps with new PG clamps made of heavy duty aluminuim alloy & bolted with galvanished steel parts, Zordar/Anushree make, suitable for ACSR Goat conductor to beboltedone conductor to another conductor as per the sample complete in all respects as per the direction of Engineer in Charge |
9 | Replacement of damaged/wornout/hotspot bearing 220 kV Line Isolator clamps with new clamps made of heavy duty aluminuim alloy & bolted with galvanished steel parts, Zordar/Anushree make, suitable for ACSR Zebra conductor to be mounted and bolted on 220 kV Incomming isolatorend as per the sample complete in all respects as per the direction of Engineer in Charge at 220/132/33kV Substation Giri Nagar |
10 | Replacement of damaged/wornout/hotspot bearing220 KV Rotary clamps of Line & Bus Isolators with new Rotary clamps made of heavy duty bimetalic strip with bolttype clamp lower side provision for fixing on isolator rod and upper side arrangment for fixing on flat aluminium isolator clamp along with all nuts bolts & plain washer as per the sample complete in all respects as per the direction of Engineer in Charge at 220/132/33kV Substation Giri Nagar |
11 | Repair & overhauling of 220 kV outdoor horizontal mounting IsolatorsWigman make at 220kV Substation Giri Nagar. The scope of work includes cleaning and lubrication of isolator post insulator base for free movement, replacing defective female contacts, setting of tendom pipes, providing and applying corrosion protection kit on male and female contacts after cleaning contact"s surface and providing a layer of anti-static coating to prevent pitting and carbon deposition due to arcing on contacts,repairing of hard operating gear mechanism by replacing of gear worm, refilling of hydraulic oil in gear chamber, replacement of Push Button switches and indication lamps, replacement of contactors, replacement of HRC fuse holders with MCB, cleaning & tightening of terminals & terminal blocks, spray painting from inside and finally testing forsmooth operation of gear mechanism and proper closing and opening of isolator blades to the entire satisfaction of Engineer-in-charge for the following isolators at 220/132kV Substation Giri Nagar:- 1. 220kV Incomer-1 : Bus-B Isolator = 1 No. 2. 220kV Incomer-2 : Bus-B Isolator = 1 No. 3. 220/132kV 100MVA Transformer-1 : Bus-B Isolator = 1 No. 4. 220/132kV 100MVA Transformer-2: Bus-B Isolator = 1 No. |
12 | Repair of inverter rating 3 KVA , Input 220 V DC, Output 230 V AC,machine No. 20170801230, modelI302P2OD, make Power One Microsystem with complete testing and commisiioning at 220/132/33KV Sub Station at Giri Nagar. |