Defence Government Departments Closing in 0 days TDR #41367036

Tender For Repair And Replacement Of Damaged Electric Cables And Lt Power Panels In Gs-I Shop Inside Ofc, Kanpur

Issued by Government Departments · kanpur, Uttar Pradesh
Tender Value
97.99 Lakhs
Estimated cost
Bid Submission
11 Jan 2024
0 days left
EMD
1.72 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kanpur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Repair And Replacement Of Damaged Electric Cables And Lt Power Panels In Gs-I Shop Inside Ofc, Kanpur ; 1 M&L Xlpe Insulated Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100Volts Grade, Crosssectional Area 300Sqmm, 3.5 Core, Make: Finolex, Havells, Kei 2 M&L Xlpe Insulated Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100Volts Grade, Crosssectional Area 240Sqmm, 3.5 Core, Make: Finolex, Havells, Kei 3 M&L Xlpe Insulated Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100Volts Grade, Crosssectional Area 185 Sqmm, 3.5 Core, Make: Finolex, Havells, Kei 4 M&L Xlpe Insulated Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100Volts Grade, Crosssectional Area 150 Sqmm, 3.5 Core, Make: Finolex, Havells, Kei, 5 Dismantling Of Old Cable Of Any Size And Any Type Inside Cable Trench 6 Cable Trench Cleaning Work 7 Disconnection / Dismantling Of Cable Of Any Size And Any Type Inside Panel. 8 Dismantling Of Cubical Lt Acb / Mccb Panel And Shifting It To Desired Place As Per Instruction Of Eic 9 This Specifications Cover The Design, Fabrication, Supply, Transportation, Unloading Of Panel At Ordnanace Factory Kanpur To The Designated Site, Testing, Erection And Commissioning Of Lt 3 Phase 4 Wire Acb & Mccb Cubical Panels And Associated Civil Works At Site. The Panels Shall Be As Per Relevant Is, 415 Volts, 50Hz Consisting Of 01 No. Acb ( Microprocessor Based ) Of 1600 Amp 4 Pole As Incomer ( Horizontal Drawout Type ) , 04 Mccbs 400 Amp ( Microprocessor Based ) And 08Nos. Mccbs ( Microprocessor Based ) 300Amp, 4 Poleas Outgoer In 3 Tier Compartment Along With Busbar-Highly Conductive Electrolytic Copper Of Rating 2000Amp, Protective Numerical Relays, Metering, Indicating Lamp & Control Wiring Etc. Control Wiring Should Be Done Using 1.5 Sqmm Copper Cable And Should Be Mcb Controlled. Breaking Capacity Of Acb 50Ka And For Mccb 36Ka. C.T. Ratio For Incomer Acb 1600 Amp: 1600 / 5 Amp And For Outgoer Mccbs 300 / 5 & 400 / 5 Amp. Tripping & Protection:Inbuiltmicro Processor Based Control, Adjustable Over Load, Short Circuit And Earth Fault Protection ( Ics=100%Icu ) . The Panel Shall Be Compartmentalised, Fabricated Out Of 1.6 Mm Thick Crca Sheet Of Suitable Size On Ms Channel Of Suitable Section And Shall Be Dust, Vermin, Rodent And Weather Proof Conforming To Ip:45. Painting Of Panel: After Seven Tank Process, Two Coats Of Shed Siemens Grey. Digital Multifunction Meter, Digital Ammeter & Voltmeter Tnc Switch, Numerical Relay, Motor Switch In Incoming Panel. Led Indication- R, Y, B , Trip & On / Off For Acb And On / Off For Mccbs. Each Mccb Should Have Digital Amperemeter. Cable Compartment: Provision For Cable Termination At The Back Side Of The Panel Having Sufficient Space For 06 Nos. Of Lt Xlpe Cables 3½ X 300 Sq.Mm In Incoming Acb And 02 Nos. Of Lt Xlpe Cables 3½ X 300 Sq.Mm For Each Out Going Mccbs.A Continuous Earth Bus Of Size 25Mm X 3Mm Copper Shall Be Provided Extending Over The Entire Length Of The Panel And To Each Outgoing Mccbs. Air Circuit Breaker Should Not Be Closed In Any Intermediate Position Other Than Three Distinct Position I.E. Service, Test And Isolated.Panel Should Have Seperate Acb / Mccb Chamber, Bus Bar Chamber, Acb Metering Chamber, Branch Bus Bar Chamber, Cable Chamber Etc. Acb Should Operate In Manual And Auto Mode. Make For Acb & Mccb:Siemens, Abb, Legrand, L&T. Make Of Multifunction Meter-Secure, Make Of Digital Ammeter & Voltmeters-Secure, L&T, Make Of Relays-Abb / Siemens / Legrand, Make Of Lug-Dowells. Make Of Control Wiring:Havells / Finolex / Polycab. 10 M&L Oflt, 1.1Kv Grade, 3.5Core Straight Through Heat Shrink Joint Suitable For Size 240 / 300 Sqmm Cable Make : Raychem, 3M, Danson 11 M&L Oflt, 1.1Kv Grade, 3.5Core Straight Through Heat Shrink Joint Suitable For Size 150 / 185 Sqmm Cable Make : Raychem, 3M, Danson 12 Cable Connection And Termination Work Complete With Gland / Armour Plate, Lugs, Nut Bolts, Washers, Crimping, Taping Etc Suitable For 300 / 240 Sqmm Cable. 13 Cable Connection And Termination Work Complete With Gland / Armour Plate, Lugs, Nut Bolts, Washers, Crimping, Taping Etc Suitable For 120 / 150 / 185 Sqmm Cable. 14 Dismantling Of Brick Work Built In Cement Mortar. 15 Removing Cement Or Lime Mortar For Cleaning Brick 16 Dismantling Of Structural Steel Work 17 M&L Brick Work With 1:6 Cement Mortar ( Except Brick ) 18 M&L Brick Work With 1:6 Cement Mortar 19 M&L For 10Mm Thick Cement Plaster With 1:4 Cement Mortar 20 M&L For Chalk White Over Plaster Surface On Walls 21 Only Fixing Steel Structure 22 M&L Steel Painting With Preparation Of Old Surface & Two Coat Of Synthetic Enamel Paint 23 M&L Rcc Cover Demolition 24 M&L Rcc Precast Cement Concrete Slabs Type B1 ( 1:2:4 ) Setting With 1:4 Cement Mortar 25 S&F Tmt Bar ( 10Mm Dia And Over ) 26 S&F Of Joist Channel Angle Fixed Independently 27 M&L Cement Concrete In Foundations Type C2 1:3:6 ( 40Mm Graded Aggregate )

BOQ

Name of Work: Repair and replacement of damaged electric cables and LT power panels in GS-I shop inside OFC, Kanpur
Sl. No. Item Description
1M&L XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100Volts grade, crosssectional area 300Sqmm, 3.5 Core, Make: Finolex, Havells, KEI
2M&L XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100Volts grade, crosssectional area 240Sqmm, 3.5 Core, Make: Finolex, Havells, KEI
3M&L XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100Volts grade, crosssectional area 185 Sqmm, 3.5 Core, Make: Finolex, Havells, KEI
4M&L XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100Volts grade, crosssectional area 150 Sqmm, 3.5 Core, Make: Finolex, Havells, KEI,
5Dismantling of old cable of any size and any type inside cable trench
6Cable trench cleaning work
7Disconnection/Dismantling of cable of any size and any type inside panel.
8Dismantling of cubical LT ACB/MCCB Panel and shifting it to desired place as per instruction of EIC
9This specifications cover the Design, Fabrication, Supply, Transportation, Unloading of panel at Ordnanace Factory Kanpur to the designated site, Testing, Erection and Commissioning of LT 3 phase 4 wire ACB & MCCB cubical Panels and associated civil works at site. The panels shall be as per relevant IS, 415 volts, 50Hz consisting of 01 No. ACB (Microprocessor based) of 1600 Amp 4 Pole as incomer (Horizontal drawout type),04 MCCBs 400 Amp (Microprocessor based) and 08Nos. MCCBs (Microprocessor based) 300Amp, 4 Poleas outgoer in 3 tier compartment along with Busbar-Highly conductive electrolytic copper of rating 2000Amp, protective numerical relays, metering, indicating lamp & control wiring etc. Control wiring should be done using 1.5 Sqmm copper cable and should be MCB controlled. Breaking capacity of ACB 50kA and for MCCB 36kA. C.T. RATIO for incomer ACB 1600 Amp: 1600/5 Amp and for outgoer MCCBs 300/5 & 400/5 Amp. Tripping & Protection:InbuiltMicro processor based control, Adjustable over load, Short circuit and Earth fault protection (Ics=100%Icu). The panel shall be compartmentalised, fabricated out of 1.6 mm thick CRCA sheet of suitable size on MS Channel of suitable section and shall be dust, vermin, rodent and weather proof conforming to IP:45. PAINTING OF PANEL: After seven tank process,two coats of shed Siemens Grey. Digital multifunction meter,Digital Ammeter & Voltmeter TNC switch, Numerical relay, Motor switch in incoming panel. LED Indication- R,Y,B , trip & ON/OFF for ACB and ON/OFF for MCCBs. each MCCB should have digital amperemeter. CABLE COMPARTMENT: Provision for cable termination at the back side of the panel having sufficient space for 06 Nos. of LT XLPE cables 3½ x 300 Sq.mm in incoming ACB and 02 Nos. of LT XLPE cables 3½ x 300 Sq.mm for each out going MCCBs.A continuous earth bus of size 25mm x 3mm copper shall be provided extending over the entire length of the panel and to each outgoing MCCBs. Air Circuit breaker should not be closed in any intermediate position other than three distinct position i.e. service, test and isolated.Panel should have seperate ACB/MCCB chamber, bus bar chamber, ACB metering chamber, branch bus bar chamber, cable chamber etc. ACB should operate in manual and auto mode. MAKE FOR ACB & MCCB:Siemens, ABB, Legrand, L&T. Make of Multifunction meter-Secure, Make of digital Ammeter & Voltmeters-Secure, L&T, Make of Relays-ABB/Siemens/Legrand, Make of Lug-Dowells. Make of control wiring:Havells/Finolex/Polycab.
10M&L ofLT,1.1kV grade, 3.5Core Straight through heat shrink joint suitable for size 240/300 Sqmm cable Make : Raychem, 3M, Danson
11M&L ofLT,1.1kV grade,3.5Core Straight through heat shrink joint suitable for size 150/185 Sqmm cable Make : Raychem, 3M, Danson
12Cable connection and termination work complete with gland/armour plate, lugs, Nut bolts, washers, crimping, taping etc suitable for 300/240 Sqmm Cable.
13Cable connection and termination work complete with gland/armour plate, lugs, Nut bolts, washers, crimping, taping etc suitable for 120/150/185 Sqmm Cable.
14Dismantling of brick work built in cement mortar.
15Removing cement or lime mortar for cleaning brick
16Dismantling of structural steel work
17M&L Brick work with 1:6 cement mortar (Except brick)
18M&L Brick work with 1:6 cement mortar
19M&L for 10mm thick cement plaster with 1:4 cement mortar
20M&L for chalk white over plaster surface on walls
21Only fixing steel structure
22M&L Steel painting with preparation of old surface & two coat of synthetic enamel paint
23M&L RCC cover demolition
24M&L RCC precast cement concrete slabs Type B1(1:2:4) setting with 1:4 cement mortar
25S&F TMT bar (10mm dia and over)
26S&F of joist channel angle fixed independently
27M&L Cement concrete in foundations type C2 1:3:6 ( 40mm graded aggregate)

AI Tender Summary

OUR REF NO 41367036
AUTHORITY Government Departments
TENDER VALUE 97.99 Lakhs
LAST DATE 11-01-2024
Authority
Authority Name Ordnance Factory
Work Description Tender For Repair And Replacement Of Damaged Electric Cables And Lt Power Panels In Gs-I Shop Inside Ofc, Kanpur ; 1 M&L Xlpe Insulated Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100Volts Grade, Crosssectional Area 300Sqmm, 3.5 Core, Make: Finolex, Havells, Kei 2 M&L Xlpe Insulated Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100Volts Grade, Crosssectional Area 240Sqmm, 3.5 Core, Make: Finolex, Havells, Kei 3 M&L Xlpe Insulated Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100Volts Grade, Crosssectional Area 185 Sqmm, 3.5 Core, Make: Finolex, Havells, Kei 4 M&L Xlpe Insulated Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100Volts Grade, Crosssectional Area 150 Sqmm, 3.5 Core, Make: Finolex, Havells, Kei, 5 Dismantling Of Old Cable Of Any Size And Any Type Inside Cable Trench 6 Cable Trench Cleaning Work 7 Disconnection / Dismantling Of Cable Of Any Size And Any Type Inside Panel. 8 Dismantling Of Cubical Lt Acb / Mccb Panel And Shifting It To Desired Place As Per Instruction Of Eic 9 This Specifications Cover The Design, Fabrication, Supply, Transportation, Unloading Of Panel At Ordnanace Factory Kanpur To The Designated Site, Testing, Erection And Commissioning Of Lt 3 Phase 4 Wire Acb & Mccb Cubical Panels And Associated Civil Works At Site. The Panels Shall Be As Per Relevant Is, 415 Volts, 50Hz Consisting Of 01 No. Acb ( Microprocessor Based ) Of 1600 Amp 4 Pole As Incomer ( Horizontal Drawout Type ) , 04 Mccbs 400 Amp ( Microprocessor Based ) And 08Nos. Mccbs ( Microprocessor Based ) 300Amp, 4 Poleas Outgoer In 3 Tier Compartment Along With Busbar-Highly Conductive Electrolytic Copper Of Rating 2000Amp, Protective Numerical Relays, Metering, Indicating Lamp & Control Wiring Etc. Control Wiring Should Be Done Using 1.5 Sqmm Copper Cable And Should Be Mcb Controlled. Breaking Capacity Of Acb 50Ka And For Mccb 36Ka. C.T. Ratio For Incomer Acb 1600 Amp: 1600 / 5 Amp And For Outgoer Mccbs 300 / 5 & 400 / 5 Amp. Tripping & Protection:Inbuiltmicro Processor Based Control, Adjustable Over Load, Short Circuit And Earth Fault Protection ( Ics=100%Icu ) . The Panel Shall Be Compartmentalised, Fabricated Out Of 1.6 Mm Thick Crca Sheet Of Suitable Size On Ms Channel Of Suitable Section And Shall Be Dust, Vermin, Rodent And Weather Proof Conforming To Ip:45. Painting Of Panel: After Seven Tank Process, Two Coats Of Shed Siemens Grey. Digital Multifunction Meter, Digital Ammeter & Voltmeter Tnc Switch, Numerical Relay, Motor Switch In Incoming Panel. Led Indication- R, Y, B , Trip & On / Off For Acb And On / Off For Mccbs. Each Mccb Should Have Digital Amperemeter. Cable Compartment: Provision For Cable Termination At The Back Side Of The Panel Having Sufficient Space For 06 Nos. Of Lt Xlpe Cables 3½ X 300 Sq.Mm In Incoming Acb And 02 Nos. Of Lt Xlpe Cables 3½ X 300 Sq.Mm For Each Out Going Mccbs.A Continuous Earth Bus Of Size 25Mm X 3Mm Copper Shall Be Provided Extending Over The Entire Length Of The Panel And To Each Outgoing Mccbs. Air Circuit Breaker Should Not Be Closed In Any Intermediate Position Other Than Three Distinct Position I.E. Service, Test And Isolated.Panel Should Have Seperate Acb / Mccb Chamber, Bus Bar Chamber, Acb Metering Chamber, Branch Bus Bar Chamber, Cable Chamber Etc. Acb Should Operate In Manual And Auto Mode. Make For Acb & Mccb:Siemens, Abb, Legrand, L&T. Make Of Multifunction Meter-Secure, Make Of Digital Ammeter & Voltmeters-Secure, L&T, Make Of Relays-Abb / Siemens / Legrand, Make Of Lug-Dowells. Make Of Control Wiring:Havells / Finolex / Polycab. 10 M&L Oflt, 1.1Kv Grade, 3.5Core Straight Through Heat Shrink Joint Suitable For Size 240 / 300 Sqmm Cable Make : Raychem, 3M, Danson 11 M&L Oflt, 1.1Kv Grade, 3.5Core Straight Through Heat Shrink Joint Suitable For Size 150 / 185 Sqmm Cable Make : Raychem, 3M, Danson 12 Cable Connection And Termination Work Complete With Gland / Armour Plate, Lugs, Nut Bolts, Washers, Crimping, Taping Etc Suitable For 300 / 240 Sqmm Cable. 13 Cable Connection And Termination Work Complete With Gland / Armour Plate, Lugs, Nut Bolts, Washers, Crimping, Taping Etc Suitable For 120 / 150 / 185 Sqmm Cable. 14 Dismantling Of Brick Work Built In Cement Mortar. 15 Removing Cement Or Lime Mortar For Cleaning Brick 16 Dismantling Of Structural Steel Work 17 M&L Brick Work With 1:6 Cement Mortar ( Except Brick ) 18 M&L Brick Work With 1:6 Cement Mortar 19 M&L For 10Mm Thick Cement Plaster With 1:4 Cement Mortar 20 M&L For Chalk White Over Plaster Surface On Walls 21 Only Fixing Steel Structure 22 M&L Steel Painting With Preparation Of Old Surface & Two Coat Of Synthetic Enamel Paint 23 M&L Rcc Cover Demolition 24 M&L Rcc Precast Cement Concrete Slabs Type B1 ( 1:2:4 ) Setting With 1:4 Cement Mortar 25 S&F Tmt Bar ( 10Mm Dia And Over ) 26 S&F Of Joist Channel Angle Fixed Independently 27 M&L Cement Concrete In Foundations Type C2 1:3:6 ( 40Mm Graded Aggregate )
Basic Detail
Tender No OFC/EOC/17/CF/2023-24
Bidding Type Tender
Location
City kanpur
State Uttar Pradesh
Key Dates
Publish Date 29 Dec 2023
Submission Date 11 Jan 2024
Open Date 13 Jan 2024
Finance
Tender Value 97.99 Lakhs
Tender Fee Ref. Documents
EMD 1.72 Lakhs
Exemption Not Available
Document List
2ec04c96-d840-45f6-ab50-68244dd196bb.html
BOQ_196742.xls
CheckListforCompliance.pdf
EligibilityCriteriaforCom_1.pdf
GeneralCondition.pdf
GeneralConditionsofContra_2.pdf
InstructiontotheBiddersfo_3.pdf
SpecialConditionsofcontra_4.pdf
SpecialNoteforCompliance.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 29, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 11, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 13, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

2ec04c96-d840-45f6-ab50-68244dd196bb.html

xls

BOQ_196742.xls

pdf

CheckListforCompliance.pdf

pdf

EligibilityCriteriaforCom_1.pdf

pdf

GeneralCondition.pdf

pdf

GeneralConditionsofContra_2.pdf

pdf

InstructiontotheBiddersfo_3.pdf

pdf

SpecialConditionsofcontra_4.pdf

pdf

SpecialNoteforCompliance.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders