Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #41355679

Dnit For Providing And Fixing Of Inlet Effluent, Monitoring System For Data Transfer To Phed, Hspcb And Cpcb And Server, 2 No. Of Uv Flow Meter At Inlet And Byepass Of Stp( As Per Guideline Of Haryana State Pollution Control Board) And Monitoring Of 4.5 M

Issued by Government Departments · Sonipat, Haryana
Tender Value
25.24 Lakhs
Estimated cost
Bid Submission
12 Jan 2024
0 days left
EMD
50481
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sonipat → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Dnit For Providing And Fixing Of Inlet Effluent, Monitoring System For Data Transfer To Phed, Hspcb And Cpcb And Server, 2 No. Of Uv Flow Meter At Inlet And Byepass Of Stp ( As Per Guideline Of Haryana State Pollution Control Board ) And Monitoring Of 4.5 Mld Stp At Matindu Road In Kharkhoda Town App

BOQ

Name of Work:-DNIT for providing and Fixing of inlet effluent, monitoring system for data transfer to PHED, HSPCB and CPCB and server, 2 No. of UV flow meter at Inlet and Byepass of STP( as per guideline of Haryana State Pollution control Board) and monitoring of 4.5 MLD STP at Matindu road in Kharkhoda Town App Cost of Rs 25.24 Lacs
Sl. No. Item Description
1Providing and fixing of inlet effluent quality Monitoring system HSPCB and CPCB server and monitoring of 4.5 MLD capacity at Matindu road in Kharkhoda Town for online ( continuous) measurement o PH, Total Suspended Solids (TSS) , Chemical Oxygen Demand (COD) , Biological Oxygen Demand (BOD) by single analyzer with various sensors (spectral measurement in the UV-VIS range 200-720mm ) performing reagent and chemical free analysis with automatic cleaning of censor, signal cables and power cables, local data acquisition and display of data on Continuous basis for up linking the data to CPCB, HSPCB and PHED, TUV approved complete in all respect as per Central Pollution Control Bord (CPCB) guidelines for online continuous monitoring system for effluents and as contained in scope of work with complete description as per NIT..
2Supply installation, testing and commissioning of Ultrasonic Flow Meter. Accessories: Mounting bracket Cable V-Notch frame Connection with existing panel Flow Meter Specifications Measuring Principle: Ultrasonic Characteristic/application Separted version with field housing or tap hat rail housing for control cabinet instrumentation, 300m in between sensor and transmitter Supply/Communications 4-wire (HART. PROFIBUS DP) Accuracy plus /-2mm plus 0.17% of measured distance Process temperature -40?C ….80?C Process pressure absolute/max,overpressure limit 0.7bar….4 bar abs Main wetted parts PVDF(IP38/NEMA6P) Process connetion Front side thread G/NPT 1 1/2` Rear side thread : G/NPT 1 ` Celling mounting Blocking distance 0.07 m (0.23 ft) Max measurement distance 1.2 m (3.9ft.) Communication Transformiyyrt 4…20 mA HART Profibus DP Options Second 4…20 mA oUtput Components Transmitter FMU90
31st year (after one year guarantee period) including existing 1 No. flow meter and 1 No. OMD sensor
42nd year (after one year guarantee period) including existing 1 No. flow meter and 1 No. OMD sensor
53rd year (after one year guarantee period) including existing 1 No. flow meter and 1 No. OMD sensor
64th year (after one year guarantee period) including existing 1 No. flow meter and 1 No. OMD sensor
75th year (after one year guarantee period) including existing 1 No. flow meter and 1 No. OMD sensor
86th year (after one year guarantee period) including existing 1 No. flow meter and 1 No. OMD sensor
97th year (after one year guarantee period) including existing 1 No. flow meter and 1 No. OMD sensor
108th year (after one year guarantee period) including existing 1 No. flow meter and 1 No. OMD sensor
119th year (after one year guarantee period) including existing 1 No. flow meter and 1 No. OMD sensor
1210th year (after one year guarantee period) including existing 1 No. flow meter and 1 No. OMD sensor

AI Tender Summary

OUR REF NO 41355679
AUTHORITY Government Departments
TENDER VALUE 25.24 Lakhs
LAST DATE 12-01-2024
Authority
Authority Name Public Health Engineering Department
Work Description Dnit For Providing And Fixing Of Inlet Effluent, Monitoring System For Data Transfer To Phed, Hspcb And Cpcb And Server, 2 No. Of Uv Flow Meter At Inlet And Byepass Of Stp ( As Per Guideline Of Haryana State Pollution Control Board ) And Monitoring Of 4.5 Mld Stp At Matindu Road In Kharkhoda Town App
Basic Detail
Tender No 2023A0A382B0 F342 4D37 9184 135D323CBBC5588PUH
Bidding Type Tender
Location
City Sonipat
State Haryana
Key Dates
Publish Date 29 Dec 2023
Submission Date 12 Jan 2024
Open Date 12 Jan 2024
Finance
Tender Value 25.24 Lakhs
Tender Fee 5000
EMD 50481
Exemption Not Available
Document List
102c89c4-6f69-482e-8de5-6b5aae156d85.html
BOQ_415207.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 29, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 12, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 12, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

102c89c4-6f69-482e-8de5-6b5aae156d85.html

xls

BOQ_415207.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders