Tender For Repair /Maintenance Of Summer / Winter Appliances And Petty Repairs Of Em Nature Including Internal Electrification At Dad New Cantt Prayagraj., prayagraj-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair /Maintenance Of Summer / Winter Appliances And Petty Repairs Of Em Nature Including Internal Electrification At Dad New Cantt Prayagraj.. Submission Date for this Tender is 22-01-2024. Electrification Work Tenders in prayagraj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41349864
Corrigendum : Tender For Repair /Maintenance Of Summer / Winter Appliances And Petty Repairs Of Em Nature Including Internal Electrification At Dad New Cantt Prayagraj.
Open Tender
Indian
Uttar Pradesh
prayagraj
22-01-2024

Tender Details

Repair / Maintenance Of Summer / Winter Appliances And Petty Repairs Of Em Nature Including Internal Electrification At Dad New Cantt Prayagraj.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 92000.0 /-
Tender Value
INR 46 Lakhs /-

BOQ Items

Name of Work: REPAIR /MAINTENANCE OF SUMMER / WINTER APPLIANCES AND PETTY REPAIRS OF EM NATURE INCLUDING INTERNAL ELECTRIFICATION AT DAD NEW CANTT PRAYAGRAJ
Sl. No. Item Description
1Taking down carefully point wiring of any type complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, surface conduit/casing caping/conceal etc. removing materials including accessories for taking credit and making good disturbed surface to match the existingcompleteall as specified & directed.
2M&L for point wiringwith FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade concealed conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed conceal surfaces complete all as specified and directed for the following :- Note:(a) Colour code of wire shall be strictly followed , Red for Phase , Black for neutral and green for earth wire (b) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surface.
3One light/fan/bell point controlled by one switch
4One point for socket outlet 5 amps on independent board
5One point for socket outlet 5 amp same board
6One 3 pin socket outlet 15 amps, independent, with cables 2.5 sq. mm size on independent board.
7M&L for point wiringwith FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) along with same size and type of wire as continuous earth wire connected to common earth dolly drawn in and includingnon metallicPVC casing and capingnot less than 20mm widemed grade ISI marked complete with all fixing accessories including factory madepressed steel concealed terminal boxof required size of 1.2mm thickduly painted with 3mm thick plasticlaminated sheet top cover with brass screw and cup washerscomplete all as specified and directedfor the following :- . Note:(a) Colour code of wire shall be strictly followed , Red for Phase , Black for neutral and green for earth wire (b) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surface.
8One light/fan/bell point controlled by one switch
9One point for socket outlet 5 amps on independent board
10One point for socket outlet 5 amp same board
11One 3 pin socket outlet 15 amps, independent, with cables 2.5 sq. mm size on independent board.
12M&L for point wiringwith FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade surface conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed surfaces complete all as specified and directed for the following :-Note:(a) Colour code of wire shall be strictly followed , Red for Phase , Black for neutral and green for earth wire (b) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surface.
13One light/fan/bell point controlled by one switch
14One point for socket outlet 5 amps on independent board but not below the switch board in same vertical plane.
15One point for socket outlet 5 amp same board
16One 3 pin socket outlet 15 amps, independent, with cables 2.5 sq. mm size on independent board.
17S&F in repair switch piano flush type, 5 amps, 230V AC,single pole, one waycompleteall as specified & directed.
18S&F socket out let 2-in-1, 3 pin, 5 amp flush type completeall as specified & directed.
19S&F bell push piano flush type 5 amp, SP , 230V ACcompleteall as specified & directed.
20S&F call bell, ding dong type, AC, 230 V, single polecompleteall as specified & directed.
21S&F fan regulator, 5 stepped, electronic type, single phase, 80 watt, socket size incl connection complete all as specified & directed.
22S&F in repair ceiling rose surface type bakelite 65x50mm three terminal complete all as specified and directed.
23S & F lamp holder adopter, two pin, insulated bakelite body for proper connection to light fitting/fixture from light point completeall as specified & directed.
24S&F angle/batten type holder insulated body with back plate suitable for light point complete all as specified and directed.
25S&F socket out let 2-in-1, 3 pin, 5 & 15 amp flush type completeall as specified & directed.
26S&F switch piano flush type 16 amps, 230V AC single pole one waycompleteall as specified & directed.
27S&F in replacement of switch socket combination 2-in-1, 3 pin, 6 and 16 Amp flush type 240 Volts, complete all as specified and directed.
28S&F PVC insulation tape of width - 18 mm, thickness - 0.125 mm in length of 25 mtr, ISI markedfor proper insulation of joints in wire where as required or directed
29S&F in repair switch modular flush type 10 amps, single pole, one way 230 voltcompleteall as specified & directed.
30S&F in repair socket modular flush type suitable for 10 amp, 5 pin ,230 voltcompleteall as specified & directed.
31S&F in repair switch modular flush type 20 amps, single pole, one way ,230 voltcompleteall as specified & directed.
32S&F in repair socket modular flush type suitable for 16 amp, 6 pin ,230 voltcompleteall as specified & directed.
33S&F fan regulator, 2 module type, 5 stepped, electronic type, single phase 230 volt includingconnection complete all as specified & directed.
34S&F bell push modular flush type 6 amp 230 voltcompleteall as specified & directed.
35S & F in repair MODULAR white cover plate with frame suitable for 2 module type complete all as specified and directed.
36S & F in repair MODULAR white cover plate with frame suitable for 3 module type complete all as specified and directed.
37S & F in repair MODULAR white cover plate with frame suitable for 6 module type complete all as specified and directed.
38S & F in repair MODULAR metal flush box suitable for 8 module type complete all as specified and directed.
39S&F MCB single pole, 6 to 32 amps rating, 240 volts, "C" series, 10 KA breaking capacity & makingconnection complete all as specified and directed.
40S&F MCB single pole & Neutral, 40/ 63 amps rating, 240 volts, "C" series, 10 KA breaking capacity & makingconnection complete all as specified and directed.
41S&F in repair MCB tripple pole & neutral 63 amp, 415 volts, "C" series, 10 KA breaking capacity & makingconnection complete all as specified and directed.
42S&F in repair MCCB 63 amp, 415 volts, "C" series, 25 KA breaking capacity with separate at both side & makingconnection complete all as specified and directed.
43Taking down main switches fuse unit, MCB/Kit kat distribution board with steel enclosure along with MCB’s /Kit kat fuse of any amps/ways including wooden board or from steel board and making good disturbed surfacescompleteall as specified & directed.
44S&F sheet metal enclosure for MCB"s 240 volt 4 way single pole and neutral with 200 amps rated busbardouble door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wallcomplete all as specified and directed.
45S&F sheet metal enclosure for MCB"s 240 volt 6 way single pole and neutral with 200 amps rated busbardouble door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wallcomplete all as specified and directed.
46S&F sheet metal enclosure for MCB"s 240 volt 8 way single pole and neutral with 200 amps rated bus bar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
47S&F sheet metal enclosure for MCB"s 240 volt 12 way triple pole and neutral with 200 amps rated busbardouble door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wallcomplete all as specified and directed.
48S&F in replacement of sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket of current rating 20 amps along with one MCB, single pole of current rating 25 amps, C series 240 volts AC completeall as specified & directed.
49S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 0.75 Sqmm or 24/0.20, 1100 Volt grade, ISI marked complete all as specified and directed.
50S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 1.5 Sqmm or 22/0.30 or 48/0.20 or 30/0.25, 1100 Volt grade, ISI marked complete all as specified and directed.
51S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size2.5 Sqmm or 36/0.30 or 80/0.20 or 50/0.25 , 1100 Volt grade, ISI marked complete all as specified and directed.
52S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 4.0 Sqmm or 56/0.30 or 128/0.20, 1100 Volt grade, ISI marked complete all as specified and directed.
53S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 6.0 Sqmm or 84/0.30, 1100 Volt grade, ISI marked complete all as specified and directed.
54S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 10.0 Sqmm or 140/0.30, 1100 Volt grade, ISI marked complete all as specified and directed.
55S&F in repair PVC insulated, unsheathed flexible twin twisted copper conductor wire ofnominal size 23/.0076, 1100 Volt grade, ISI marked complete all as specified and directed.
56S&F in repair PVC insulated, unsheathed flexible twin twisted copper conductor wire ofnominal size 40/.0076, 1100 Volt grade, ISI marked complete all as specified and directed.
57S & F in repair condenser of 2.5 MFD, 440 Volt AC , conforming to IS - 1709 suitable for fans complete all as specified and directed.
58Taking down carefully sub main wiring of any nos of wire and size with earth wire on wooden batten/surface conduit/casing caping complete with its all accessories completeall as specified & directed.
59M&L for concealed submain wiring using FRLS PVC insulated, unsheathed stranded copper conductor cable two single core of size 2.5 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories alongwith one run of PVC insulated unsheathed stranded copper conductor of size 2.5 Sqmm as earth continuity conductor & making good to disturbed surface with CM 1:4 and colour wash complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
60M&L for concealed submain wiring using FRLS PVC insulated, unsheathed stranded copper conductor cable two single core of size 4.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories alongwith one run of PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm as earth continuity conductor & making good to disturbed surface with CM 1:4 and colour wash complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
61M&L for concealed submain wiring using FRLS PVC insulated, unsheathed stranded copper conductor cable two single core of size 6.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories alongwith one run of PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm as earth continuity conductor making good to disturbed surface with CM 1:4 and colour wash complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
62M&L for concealed submain wiring using FRLS PVC insulated, unsheathed stranded copper conductor cable two single core of size 10 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories alongwith one run of PVC insulated unsheathed stranded copper conductor of size 10 Sqmm as earth continuity conductor making good to disturbed surface with CM 1:4 and colour wash complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
63Supply & fixing in replacement surface /wall mounted light fitting in CRCA powder coated white housing with pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen output - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed.
64Supply & fixing in replacement energy efficient LED light fitting of 10 Watt LED of length - 02 Feet long having minimum 1150 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, Surge protection 3KV, CRI>80 life 40000 hrs sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat part No: -LUMILINEPLUSSBS10WLED865SPCSS of make Havells "or" BN 021 LED10S- 6500 PSU GR S1 of make Philips "or" LDL-10-WW of make Crompton or its equivalent as approved
65S&F in replacement energy efficient LED Bulkhead in high pressure die cast aluminium housing of system wattage - 9/10 Watt, lumen out put - 700 Lm, colour Temp - 6500 K having Ingress protection - IP 65 fpr dust, water & IK 08 for external impact complete all as specified and directed.
66S&F in replacement of worn out/old linear fluorescent tube of 36 watt with energy efficient/saving retrofitLED tube in polycarbonate housing of nominal wattage - 18/20 Watt, Lumen output - 2100 Lm or above, Colour Temp - 6500 Kelvin, Size & Length - G13/T8/4 Feet, Operating Voltage - 230 Volt AC, THD = 20 % with integral/in built driver, having short circuit and surge protection upto 4 KV and other safety test as per IS 15885 Part 2/Sec 13 including making minor addition/alteration in existing circuit as required complete all as specified and directed.
67S&F in replacement of existing worn out ceiling light with environmental friendly, new generation, aesthetically designed, ultra modern recessed mounted LED light luminaries of size 595 mm x 595 mm an independent Isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage - 36/40/42 Watt, Lumen out put- 4000-4300 Lm, THD < 10%, PF > 0.9, having short circuit and surge protection suitable for Armstrong/ Grid ceiling with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed.
68S&F in replacement of Decorative wall mounting fixture with elegant diffuser, Floral blown glass, Metal of holder base, ambience E27, 1x8W, along with LED lamp 8 watt ,complete in specified and as directed. Make : Philips Model No. 37934/06 or its equivalent inHavells/Crompton Greaves.
69S & F in replacement of existing worn out spot light 12 watt of 155 mm dia with Recess mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver complete with LEDs, in built electronic LED driver and accessories pre-wired up to terminal block including making connection complete all as specified and directed. Cat pt No: EDGEPRODDLR12WLED840S of make Havells "or" DN191B LED12S-4000 PSU WH S2 of make Philips "or" CDR -204-12-57-SL-NWHof make Crompton orits equivalent as approved.
70Supply and fixing in replacement of worn out wooden batten/PVC Conduit with Non Metallic Rigid PVC conduit of 20 mm niminal dia, ISI Marked, conforming to IS 9537 Part III, medium grade including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete in all respect as specified and directed.
71Supply and fixing in replacement of worn out wooden batten/PVC Conduit with Non Metallic Rigid PVC conduit of 25 mm niminal dia, ISI Marked, conforming to IS 9537 Part III, medium grade including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete in all respect as specified and directed.
72Supply & fixing in replacement of worn out/rustedsunken box of size 100 mm X 100 mm with pressed MS/GI steel terminal boxes of depth not less than 50 mm, flush type of thickness lot less than 1.22 mmof following size alongwith new 3.0 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete in all respect as specified and directed.
73Supply & fixing in replacement of worn out/rustedsunken box of size 175 mm X 100 mm with pressed MS/GI steel terminal boxes of depth not less than 50 mm, flush type of thickness lot less than 1.22 mmof following size alongwith new 3.0 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete in all respect as specified and directed.
74Supply & fixing in replacement of worn out/rustedsunken box of size 200 mm X 150 mm with pressed MS/GI steel terminal boxes of depth not less than 50 mm, flush type of thickness lot less than 1.22 mmof following size alongwith new 3.0 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete in all respect as specified and directed.
75Supply & fixing in replacement of worn out/rustedsunken box of size 250 mm X 200 mm with pressed MS/GI steel terminal boxes of depth not less than 50 mm, flush type of thickness lot less than 1.22 mmof following size alongwith new 3.0 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete in all respect as specified and directed.
76M& L for repairing of unserviceable Gate lightof any type/makeby replacing burn out/worn-out/ weakLED lamp 25 watt and re- fixing the fitting in position after repair and testingcomplete.
77S&F (in replacement) Gate light post top luminaire with diamond shaped opal diffuser mounted on cast aluminium capsule suitable for 1x15 watt LED including lamp and connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm complete all as specified & directedMake-Crompton Greaves Cat Part No. CFPT1145/BM/BC ortechno commercially equivalent model in Philips/Havells/Wipro/Crompton
78S&F (in replacement) garden light fitting suitable for LED lamp 1x18 wattincluding LED, light fittings moulded plastic capsule which house ballast, lamp holder, baffles for glare control etc. along with GI tubing 50 mm bore light grade - 1.2 RM approx.duly groutedwith required civil/PCC/brick work as in foundation incl connection using suitable bakalite connector & connection with PVC insulated cable with copper conductor of size 1.5 sqmm of length 1 mtr approx. from connector to fitting terminal complete all as specified and directed.
79S &F in replacement of Oval shaped post top lantern in prismatic finish made up of polycarbonate, suitable up to 27 watt retrofit CFL/LED (B-22 base) connection of pole boxto fitting with 1.5 sqmm pvc insulated copper conductor flexible wire and testing complete all as specified and directed. Make : Havells model No. Athena2 Code No. LHDC12115099 ortechno commercially equivalent model in Philips/Havells/Wipro/Crompton
80S &F in replacement of Crown shapedpost top lantern in smoothing moon finish made up of polycarbonate, suitable up to 27 watt retrofit CFL/LED (B-22 base) including connection of pole boxto fitting with 1.5 sqmm pvc insulated copper conductor flexible wire and testing complete all as specified and directed. Make : Havells model No. Athena3 Code No. LHDC11126099 or techno commercially equivalent model in Philips/Havells/Wipro/Crompton
81S &F in replacement of worn out CFL with energy efficientrechargeable LED lamp of 7 watt with in built lithium battery of capacity 2000 mAH minimum lumen output 600 Lm or above, based cap- B 22 complete all as specified and directed.
82CEILING FAN, EXHAUST FAN
83M&L for rewinding of stator complete with super enameled copper winding wire of existing gauge/ weight of copper coil, quick varnishing, oiling, greasinginsulating materials including replacement of worn out parts like u/s cotter pin, nut, screw, check nuts and bolts as required incl. cleaning of body, and testingof the following size of fans of any make complete all as specified and directed. Note - (i) Fans to be collected by the contractor at their own arrangement from AGE E/M store forrepair/rewinding and to be deposited at same place after making serviceable duly tested. (ii) Aditional spare parts as required to make the serviceable of same will be measured and paid separately as supply only under srl item No. 3 of schedule here in below:-
84Ceiling fan of 1200 mm sweep
85Ceiling fan of 1400 mm sweep
86Exhaust fan of 230 mm sweep
87Exhaust fan of 300 mm sweep
88Exhaust fan of 380 mm sweep
89Exhaust fan of 450 mm sweep
90Wall fan/cabin/Pedestal of 400 mm sweep
91Supply only following spare parts for Ceiling / Exhaust fan : -
92Ball bearing of ceiling/exhaust fan of any size of exactly similar as existing in fan complete all as specified and directed. (Make-NBC/SKF)
93U" shape shackle clamp assembly made out of MS flat iron incl checknut, bolts, screws, washer, split pin, lock nut, rubber reel etc. suitable to the down rod pipe and connecting complete all as specified and directed.
94Capacitor 2.5 Mfd, 440 Volt AC complete all as specified and directed. Make - Asian/Usha/Epcos of siemens /Havells or as approved by GE
95Capacitor 3.15 Mfd, 440 Volt AC complete all as specified and directed. Make - Asian/Usha/Epcos of siemens /Havells or as approved by GE
96PVC insulated, sheathed flexible copper conductor cable in three core of size 23/0.0076 from connector to the ceiling rose complete all as specified and directed.
97Capacitor clip as per existing complete all as specified and directed.
98Canopy for ceiling fan suitable for any sweep/make as required incl. screw complete all as specified and directed.
99M&Lfor Spray painting of stained/rusted/corroded Ceiling fan/Exhaust fan complete body with one coats of synthetic enamel white/smoke gray paint incl writing of MES No over one coat of primer all as specified and directed.
100S&F in replacement of MS louvers shutters on wall suitable for 300 mm sweep exhaust fan including suitable size of nut, bolts & washercomplete all as specified and directed.
101S&F in replacement of MS louvers shutters on wall suitable for 450 mm sweep exhaust fan including suitable size of nut, bolts & washercomplete all as specified and directed.
102M & L for servicing of ceiling fans at site, oiling, greasing and checking of fan hook for damage spilt pin, nut bolt, rubber reels and down rod including proving new split pin and replacement of damage nut bolt and down rod complete all as specified and directed. Note: (i)Down rod measured and paid separately under relevant items
103S&F in replacement Mild steel"Medium grade" 15mm dia pipe down rod of required length with makingsplit, holes, cut etc at both end of pipe as required for hanging ofceiling fan including painting of rod with two coats of synthetic enamel white paint over one coat of primer along with U" shape shackle clamp assembly made out of MS flat iron incl checknut, bolts, screws, washer, split pin, lock nut, rubber reel complete all as specified and directed.
104S&F in repair fan hook suitable for 40 mm dia pipe, made out of MS flat iron size 50x6 mm including suitable size of nut, bolt & washer complete all as specified and directed.
105AC WINDOW/SPLIT TYPE
106Repair/maint of window type AC/split AC any capacity of any make by cleaning and servicing of serviceable parts replacement of wiring kit, knobs & unserviceable parts replacement of air filter made of jute and reassembling the serviceable spare parts etc and testing for smooth functioning and re installation at site or deposit in MES store yard after repair. [Notes : (a) Spare parts shall be measured and paid separately as supply only under respective items. (b) Replacement of nuts, bolts and washers deemed to be included in unit rate. (c) Minor repair of chassis by brazing/welding work deemed to be included in unit rate.]
107Removing burnt/defective sealed compressor unit of any make from any type of air conditioner window type 1.5 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply amd fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc all as directed. Make:Emersion/ LG/ Haier
108All as per item No. 81 above but for 1.5 ton Split type Air conditioner [Notes : (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b) New compressors will be purchased from authorized dealer only. (c) Unserviceable compressor either cut open or sealed unit have to be replaced by new one
109All as per item No. 81 above but for air conditioner window / split type 2 ton capacity
110Repair to Air conditioner window type/Split type 1/1.5/2 ton capacity by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system and charging of gas as existing andtesting etc complete all as specified & directed (Note : Drier capillary and copper tubing are inclusive in unit rate)
111S&F in replacement of blower Motor 1/5 or 1/6 HP 230V AC, 50 Hz suitable for Air conditioner window type 1.5 ton capacity blower motor complete all as directed and specified
112S&F in replacement of blower Motor 0.2/0.25 HP for Air conditioner split type 1.5 ton/2 ton complete and as directed and specified (Make - GE/Crompton/Polar)
113M & L for repair to blower Motor1/6 HP to 0.25 HPwith super enamelled copper wire of existing size suitable for Air conditioner window type / split type complete all asspecifiedand directed
114M& L for repair to PCB circuit in air conditioner split type all as specified & directed.
115S&F in replacement ofpower contactor 240V AC, 50 Hz 16 - 25 Amps range (ISI marked) as approved complete all asspecifiedand directed.
116Supply and fixed in replacement of power contactor 415V AC, 50 Hz 16-25 Amps (Make - L&T Type MK-I/BCH or as approved)
117M&L for painting of chassis/body of AC with one coat of synthetic enamel paint by spray painting of approved make including preparation of surface and one coat of aluminium paint to outer cover.
118Supply only following spare parts for window type AC capacity 1.5/2 ton : -
119Capacitor 4 mfd
120Running capacitor 36 mfd AC
121Starter capacitor 80/100 mfd
122Relay any make and type as approved
123Over load protector
124Thermostat
125Cooling coil
126Filter pad made of Jute
127Condensers coil
128Selector switch
129Wiring kit
130Front Panel of window AC any make of 1.5/2TR
131Blower
132M&L for Stands for Discharge unit of Split type AC/ Desert coolerstand etc. as per requirement and directed by Engr -in-charge
133S&F in replacement indoor unit of AC 1.5 ton capacity split type of approved make as directed (Note-Old unit to be deposited in MES store yard)
134WATER COOLER
135Dismantling of electric connection and water connection of water cooler & opening the condensor fan motor blade, electrical accessories and spare parts of system carefully servicing of serviceable parts, replacement of U/S parts, oiling of fan motor etc reassembling all spare parts incl rewiring of internal connection of water cooler, testing and commissioning complete all as specified. (Note: Worn out or unserviceable spare parts to be replaced & shall be measured and paid separately as supply only under respective item.)
136Removing burnt/defective sealed compressor unit of any make from water cooler cap 40 Ltrs/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, supply and fixing new sealed compressor unit Make as existing or equivalent in kirloskar or tecumsehby tightening the foundation nuts and bolts and connecting suction and discharge line with gas welding work etc complete. [Note:- (i) Cost of transportation shall be deemed to be included in the quoted rates. GI fitting damaged while taking out/fixing back water coolers shall be replaced by the contractor at his own cost. (ii) New compressor shall be purchased from authorised dealer only. (iii) Capillary, drier, filter strainer are inclusive in unit rate. (iv) Old compressor either cut open or sealed have to replaced with new one.]
137All as per item No 97 above but water cooler Cap 60 Ltrs/hr
138All as per item No 97 above but water cooler cap 150 Ltrs/hr.
139M&L for replacement of Rubber hose pipe of 20mm bore with clips for outlet tray of water cooler of length 1.5 Mtr long approx. complete all as specified & directed
140M&L for replacement of PVC sheet rubber bedding and lock of top cover of water cooler by screwing/welding MS sheet of top cover complete all as specified & directed
141M&L for replacement of PVC connection rigid type 18” long 15mm bore, with adopter at both ends complete all as specified & directed.
142M&L for making the system leak proof and charging of gas Freon 12/22 as required in water cooler of capacity 40/60 Ltr including replacement of drier and capacity tube and testing on load complete all as specified & directed.
143All as per item No. 103 above but of capacity 120/150 ltrs.
144M&L for scraping old painted surface of water cooler any capacity and painting with two coats of synthetic enameled paint including writing SM/MES No with black paint with minimum 25 mm size of letters complete all as specified & directed.
145M&L for replacement of old condenser fins with new, forced air-cooled including necessary brazing work for water cooler of any capacity including testing for leakage complete all as specified & directed.
146S&F in replacement of condenser fan motor of cap 1/35 HP with fan blade complete all as specified & directed.
147M & L for winding of condenser fan motor of cap upto 1/8 HP with super enamelled copper wire of existing size including replacement of bush and fan blade incl painting complete all as specified & directed.
148S&F in replacement of push cock/lift cock brass chromium plated 15 mm bore complete all as specified & directed..
149M&L for replacement of 40 mm dia flexible PVC pipe for the drainage of waste water of water coolers or concealing the copper tubing of split AC and condensed moisture of air conditions complete all as specified & directed.
150M&L for replacement of 50 mm dia flexible PVC pipe for the drainage of waste water of water coolers or concealing the copper tubing of split AC and condensed moisture of air conditions complete all as specified & directed.
151M&L for replacement of 60 mm dia flexible PVC pipe for the drainage of waste water of water coolers or concealing the copper tubing of split AC and condensed moisture of air conditions complete all as specified & directed.
152Detection and rectification of leakage of storage tank of water cooler by brazing soldering/welding as required at site or work shop testing for leak proof complete all as specified & directed. [Note : (a) Nipple adoptor if required deemed to be included in unit rate. (b) Push cock, float valve etc if required will be measured and paid separately. (c) Changing of rubber/plastic packing is incl in unit rate]
153Taking out the drain tray with PVC pipe of water cooler, electroplating (chromium plating) of drain tray after repair by denting/painting and including replacement of new PVC pipe of suitable size and length and refixing back all as directed.
154Supply only following spare parts for water cooler : -
155Starting capacitor 60/80 mfd
156Running capacitor 10 mfd
157Thermostat
158Relay over load kit
159Relay
160Over load protector 1022
161Wiring kit
162Strainer/filter drum type/pen type
163Door gasket
164Float valve 1/2" including assembly brass made.
165VOLTAGE STABILIZER
166M&L for opening unserviceable automatic voltage stabilizer capacity 5 KVA / 4 KVA for repair,detection of fault and its repair cleaning of serviceable parts, replacement/repair of unserviceable or worn out parts soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally all as specified including sign writing "AGE E/M New Cantt" all as directed any make:-[Note: (a) Replacement of new parts/worn out parts in lieu of unserviceable/worn out parts shall be measured and paid separately as supply only under respective item.(b) The flexible 3 core cable, 40/.0076, 23/.0076, 70/.0076 to be provided at least 1.5 RM is included in unit rate.]
167M&L for opening unserviceable automatic voltage stabilizer capacity 3 KVA for repair,detection of fault and its repair cleaning of serviceable parts, replacement/repair of unserviceable or worn out parts soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally all as specified including sign writing "AGE E/M New Cantt" all as directed any make:-[Note: (a) Replacement of new parts/worn out parts in lieu of unserviceable/worn out parts shall be measured and paid separately as supply only under respective item. (b) The flexible 3 core cable, 40/.0076, 23/.0076, 70/.0076 to be provided at least 1.5 RM is included in unit rate.]
168Supply only the following spare parts suitable for automatic voltage stabilizer of any make and capacity :-
169Volt meter (0-300 volts)
170Control relay
171IC controlled circuit for 5KVA/4 KVA
172IC controlled circuit for 3 KVA
173Control transformer
174Low/high voltage cut off and TDR system
175Main transformer for 5 KVA/4 KVA
176Main transformer 3 KVA
1773 pin plug top 16 amp make Anchor
178M&L for rewinding of boost/buck transformer of5 KVA/4 KVA capacity stabilizer with copper wire of existing gauge and same number of turn with best quality insulating material including testing complete and refixing back electrically and mechanically complete all as specified & directed.
179M&L for rewinding of boost/buck transformer of3 KVA capacity stabilizer with copper wire of existing gauge and same number of turn with best quality insulating material including testing complete and refixing back electrically and mechanically complete all as specified & directed.
180S&F in replacementof 5 KVA stabilizer 230 volts Single phase (Note-Old to be deposited in MES store yard). (Make : Blue star/Vinitec/Brentford/Automatic Electric)
181WINETR APPLIANCES
182Taking down existing geyser any capacity/ type after suitable disconnecting all electrical and water supply connection, removing geyser to E/M store, opening and dismantling the complete geyser, cleaning all serviceable parts completely including descaling the geyser, for replacing the defective/wornout parts, reassembling the geyser, testing for proper functioning, transporting to& refixing in original location i.e. in the same in position, reconnecting the geyser with electric supply and water supply line and testing complete all as specified and directed. Note :-(i) Parts/sparesrequired for replacement shall be measured and paid separately as supply only under respective item. (ii) Unit rate quoted shall be deemed to include minor items i.e. nut bolts, screws, lugs etc .
183S&F in repair Heating element Square, threaded/ screwed type 1500 watt ISI markedcomplete all as specified and directed. Make Theeta/ Bajaj/ Hot top/Daspass or equivalent as approved.
184S&F in repair Heating element cup type 1500 watt (ISI marked) complete all as specified and directed.Make - Bajaj/ Dass Pass/ Threeta or equivalent approved.
185S&F in repair Heating element threaded/screwed type 2000 watt (ISI marked) suitable markedcomplete all as specified and directed. Make - Bajaj/Theeta/Hot top/ Daspass or equivalent as approved.
186S&F in repair Heating elementcup type 3000 watt (ISI marked) complete all as specified and directed. Make - Bajaj/Theeta/Hot top/ Daspass or equivalent as approved.
187S&F in repair Thermostat suitable for geyser range 20 degree to 80 degree (ISI marked) complete all as specified and directed.Make-Thermoking/TTE,Elcon/ Expo/ Antriksh or equivalent approved.
188S&F in repair PVC connection cotton braided heavy duty with brass union/coupling of length 450 mm with rubber washer suitable for 15 mm pipe complete all as specified and directed..
189S&F in repair Hot water outlet connection made of chromium plated flexible tubing for 15 mm bore pipe complete all as specified and directed.
190S&F in repair Indicator lamp assembly with bulb with long lead suitable for geysers round or square type as sample kept in GE’s office complete all as specified and directed..
191S&F in repair PVC insulated flexible wire three core 2.5 sqmm copper conductor heavy duty complete all as specified and directed..
192S&F in repair Aperture plate assembly suitable for25 ltrs geyserscomplete all as specified and directed.
193S&F in repair Apperture plate assembly suitablefor 50 ltrs geysers complete all as specified and directed.
194S&F in repair Inner copper tank made out of 0.8mm(min.)for 25 ltrs geyser complete all as specified and directed.
195S&F in repair Outer body with red,green indicator and bottom cover as per existing size & shape of capacity 25 ltrs geyser complete all as specified and directed.
196S&F in repair 3 pin 15 amp plug top complete all as specified and directed. Make Anchor or equivalent as approved
197S&F in repair electronic sensor for thermal setting as per sample kept in AGE E/M office complete all as specified and directed.
198M&L for painting of geysers after scraping, cleaning and preparing surface for painting and painting with two coats of white enameled paint of approved make and sign writing MES No etc of 25 ltr capacity geyser complete all as specified and directed
199M&L for painting of geysers after scraping, cleaning and preparing surface for painting and painting with two coats of white enameled paint of approved make and sign writing MES No etc of 50 ltr capacity geyser complete all as specified and directed
200Repair of leakage of inner tank 25/50 ltr capacity geyser by brazing/soldering, testing including cutting of nut, bolt as required with gas welding cutter and providing new nut, bolts, washers etc complete all as specified and directed.
201S&F in repairs Chromium plated brass stop cock 15 mm bore, screwed down, high pressure with crutch or butterfly handle complete all as specified and directed.
202S&F in repairs MCB DP 32 amp, 230 volt, AC , 10 KAwith indication & enclosure complete all as specified and directed.
203S&F in repairs mild steelfoundation nuts, bolts & washers heavy duty for fixing of geyser including grouting in wall complete all as specified and directed. .
204M&L for Non return valve verticletype screwed for both ends with 15mm bore GI pipe. Complete all as specified and as directed.
205S&F in repair fusible plug steel nut complete all as specified and directed.
206S&F in repair Timmer suitable for Hevalls geyser (ISI marked) complete all as specified and directed.
207M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washersincluding necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and saltPCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover reinforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed.
208S&F mirror light fitting 8 watt LED decorative compact energy efficient luminaire with anti glare diffuser complete all as specified and directed.
209M&L for repair to light/fan/bell point, socket point, power point, two way point by replacing defective/ worn out wire/ switch/ holder/socket/fitting & fixtures/light fittings or any other fault and making good the point serviceable in all respect complete all as specified & directed. Note:- (i) Cost of replacing burnt wire/holder/fitting& fixtures will be measured and paid separately(ii) Contractor will report to JE E/M of PCDA (P) complaint cell daily at morning 0900 hrs except Sunday and holidays and collect the complaint slip from respective JE and attending all the complaints given by JE and completion report will given to the concerned JEs every day at 1700 hrs without any delay.
210Schedule of Credit (MINUS) Rs. 2,30,899.50 B/F from Serial Page No.[Note : Detailsof items for schedule of credit is given on Srl Page No. ] This amount shall be automatically deducted to arrive at tendered sum
Disclaimer :