Tender For Repair /Maintenance Of Dg Sets, Amf Panel, Laundry Plant And Repair To Turbo Charger, Self Starter, Battery Charger, Replacement Of Battery And Its Associated Work At New Cantt Prayagarj., prayagraj-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair /Maintenance Of Dg Sets, Amf Panel, Laundry Plant And Repair To Turbo Charger, Self Starter, Battery Charger, Replacement Of Battery And Its Associated Work At New Cantt Prayagarj.. Submission Date for this Tender is 22-01-2024. Starter Tenders in prayagraj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41349858
Corrigendum : Tender For Repair /Maintenance Of Dg Sets, Amf Panel, Laundry Plant And Repair To Turbo Charger, Self Starter, Battery Charger, Replacement Of Battery And Its Associated Work At New Cantt Prayagarj.
Open Tender
Indian
Uttar Pradesh
prayagraj
22-01-2024

Tender Details

Tender For Repair /Maintenance Of Dg Sets, Amf Panel, Laundry Plant And Repair To Turbo Charger, Self Starter, Battery Charger, Replacement Of Battery And Its Associated Work At New Cantt Prayagarj.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPAIR /MAINTENANCE OF DG SETS, AMF PANEL, LAUNDRY PLANT AND REPAIR TO TURBO CHARGER, SELF STARTER, BATTERY CHARGER, REPLACEMENT OF BATTERY AND ITS ASSOCIATED WORK AT NEW CANTT PRAYAGARJ.
Sl. No. Item Description
1SECTION "A" (DG SET)
2M&L for periodicalservicing of diesel engine driven Gen set 3 phase 415 volts 50 c/s AC supply by cleaning thoroughly and replacing fuel filters, air filters, oil filtersdraining out engine oil etc. and replacing with new oil, tightening of all gaskets , connection of battery terminals, electric cable connections foundation bolts, coupling bolts etc includingtest running and tappet setting of alternator by checking and setting of voltage and frequency complete all as directed. Note: Engine oil, Fuel filters, Air filters, oil filtersreplaced will be measured and paid separately under respective item ofSch "A" . forfollowingcapacities of DG set
3320 / 380 KVA DG SET
4250/ 200 KVA DG SET
5100 KVA DG SET
663/62.5 KVA DG SET
740/ 50 KVA DG SET
825 /20 KVA DG SET
97.5 / 5 KVA DG SET
10Supply only following spare parts for Ceiling / Exhaust fan : -
11Supply and fixing in replacement of maintenance free batterywith initiallychargedcapacity 180 AH , 12 Volt complete all as specified and as directed.
12Supply and fixing in replacement of maintenance free batterywith initiallychargedcapacity 150 AH , 12 Volt complete all as specified and as directed.
13Supply and fixing in replacement of maintenance free batterywith initiallychargedcapacity90 AH , 12 Volt complete all as specified and directed.
14Supply, fixing & testing in replacement of Radiator of 320 KVA DG Setwater cooled of kirloskar make with coppertubing including replacement of connected items such as inlet & outlet rubber hoses & all other connected items complete all as specified and directed.
15Supply, fixing & testing in replacement of Radiator of 62.5 /100 KVA DG Setwater cooled of kirloskar make with coppertubing including replacement of connected items such as inlet & outlet rubber hoses & all other connected items complete all as specified and directed.
16S&F in replacement of UNSV radiatorhose pipeset complete forDG set of 320 / 380 KVA capacity complete all as specified and directed.
17S&F in replacement of UNSV radiatorhose pipeset complete forDG set of 250 / 200 KVA capacity complete all as specified and directed.
18S&F in replacement of UNSV radiatorhose pipeset complete forDG set of 100 KVA capacity complete all as specified and directed.
19S&F in replacement of UNSV radiatorhose pipeset complete forDG set of 63/62.5 KVA capacity complete all as specified and directed.
20S&F in replacement of UNSV radiatorhose pipeset complete forDG set of 40 / 50 KVA capacity complete all as specified and directed.
21S&F in replacement of UNSV radiatorhose pipeset complete forDG set of 25 / 30 KVA capacity complete all as specified and directed.
22S&F in replacement of UNSV radiatorhose pipeset complete forDG set of 7.5 / 15 KVA capacity complete all as specified and directed.
23M & L in replacement of UNSV fan belts for DG setsof 320 / 380 KVA capacity complete all as specified and directed.
24M & L in replacement of UNSV fan belts for DG setsof 250 / 200 KVA capacity complete all as specified and directed.
25M & L in replacement of UNSV fan belts for DG setsof 100 KVA capacity complete all as specified and directed.
26M & L in replacement of UNSV fan belts for DG setsof 63/ 62.5 KVA capacity complete all as specified and directed.
27M & L in replacement of UNSV fan belts for DG setsof 40 / 50 KVA capacity complete all as specified and directed.
28M & L in replacement of UNSV fan belts for DG setsof 25 / 30 KVA capacity complete all as specified and directed.
29M&L in replacement of stranded copper conductor battery lead for 24 volts DC grade red for (+) ve terminal and black for (-) ve terminal fitted with battery terminal at one end & battery lug at other end complete length 1.5 mtr complete all as specified and directed.
30M&L for cleaning of radiator by cleaning agent/ Ready wash (make: Fleet guard/cool guard) including removal/ dismantling of radiator from engine transporting to work shop or cleaned at site, soldering / brazing, testing for any leakage , remounting to its original positionfor 320 / 380 KVA capacity DG Set complete all as specified and directed.
31M&L for cleaning of radiator by cleaning agent/Ready wash (make: fleet guard/cool guard) including removal/ dismantling of radiator from engine transporting to work shop or cleaned at site , soldering / brazing, testing for any leakage , remounting to its original position for 200/ 250 capacity DG Set complete all as specified and directed.
32M&L for cleaning of radiator by cleaning agent/Ready wash (make: Fleet guard/Cool guard) including removal/ dismantling of radiator from engine transporting to work shop or cleaned at site , soldering / brazing, testing for any leakage , remounting to its original position for 100 KVA capacity DG Set complete all as specified and directed.
33M&L for cleaning of radiator by cleaning agent/ Ready wash (make: Fleet guard/cool guard) including removal/ dismantling of radiator from engine transporting to work shop or cleaned at site, soldering / brazing, testing for any leakage , remounting to its original positionfor 63 / 62.5 KVA capacity DG Set complete all as specified and directed.
34M&L for cleaning of radiator by cleaning agent/ Ready wash (make: Fleet guard/cool guard) including removal/ dismantling of radiator from engine transporting to work shop or cleaned at site, soldering / brazing, testing for any leakage , remounting to its original positionfor 40 / 50 KVA capacity DG Set complete all as specified and directed.
35M&L for cleaning of radiator by cleaning agent/Ready wash (make: Fleet guard/Cool guard) including removal/ dismantling of radiator from engine transporting to work shop or cleaned at site , soldering / brazing, testing for any leakage , remounting to its original position for 15 / 30 KVA capacity DG Set complete all as specified and directed.
36M&L for replacement of set of hose clips for 320 / 380 KVA DG sets complete all as specified and directed.
37M&L for replacement of set of hose clips for 200 / 250 KVA DG sets complete all as specified and directed.
38M&L for replacement of set of hose clips for 100 KVA DG sets complete all as specified and directed.
39M&L for replacement of set of hose clips for 63 / 62.5 KVA DG sets complete all as specified and directed.
40M&L for replacement of set of hose clips for 40 / 50 KVA DG sets complete all as specified and directed.
41M&L for replacement of set of hose clips for 15 / 30 KVA DG sets complete all as specified and directed.
42M&L for coolant radicool SFO premixfor DG set complete all as specified and directed.
43M&L to drain out the old used engine oil from sump of DG sets& cleaning & refilling with new engine oil 15 W 40 up to required level including top up complete all as specified and directed.
44M&L for replacement of defective self starter assembly by new self starter assembly 12/24 volts complete all as specified and directed. Make: lucas / Bosch
45M&L for replacement of defective alternator assembly by new alternator assembly 12/24 volts complete all as specified and directed. Make: lucas / Bosch
46M&L in for replacement of PCB card Procom R E L-7-1.0 for 225/63.5 KVAAMF panel complete all as specified and directed.
47M&L in for replacement coil Relay-24 volts,5 Amp 240 volt AC 5Amp 30 volts DC model HJQ 22 F –VZ make YOI/ Siemens for 160/100KVA AMF panel complete all as specified and directed.
48M&L in for replacement coil Relay-24 volts,5 Amp 240 volt AC 5Amp 30 volts DC model HJQ 22 F –VZ make YOI/ Siemens for 62.5/40KVA AMF panel complete all as specified and directed.
49M&L in for replacement of timer switch0 to 80 seconds MakeSiemens for160/100KVA AMF panel complete all as specified and directed.
50M&L for servicing of DG set 250 / 200 KVA AMF panel, setting of time delay switch ,tightening of all electrical incoming & outgoingconnections including replacement of cable lugs& adjustment of solenoid switches & relays complete all as specified & directed.
51M&L for servicing of DG set 100 KVA AMF panel,setting of time delay switch ,tightening of all electrical incoming & outgoingconnections including replacement of cable lugs & adjustment of solenoid switches & relays complete all as specified & directed.
52M&L for servicing of DG set 62.5/40 KVA AMF panel, setting of time delay switch ,tightening of all electrical incoming & outgoingconnections including replacement of cable lugs & adjustment of solenoid switches & relays complete all as specified & directed.
53Supply, installation, commissioning & testing of electronic battery charging setsuitable for charging batteries12/24 V, 10/12Amps complete with meter equipments, selector switch with required size of copper wire up to required lengthand 1No. 3 pin plug top 5 Amps including disconnecting & taking out of existing battery charging set complete all as specified.
54M & L for painting of Generating set of capacity100KVA to 320KVA complete in existing colour with twocoat of synthetic enamelled paint byspray machineafter preparation of surfaces complete all as specified and as directed.
55M & L for painting of Generating set of capacity7.5KVA to 62.5KVA complete in existing colour with twocoat of synthetic enamelled paint with spray machine after preparation of surfaces complete all as specified and as directed.
56S & F in repair euroload four pole change over with advance Neutral On load change over switch I-O-II ,current Rating 100 Amps, 415 Volts complete all as specified and directed.
57S & F in repair euroload four pole change over with advance Neutral On load change over switch I-O-II ,Current Rating 200 Amps,415 Volts complete all as specified and directed.
58S & F in repair euroload four pole change over with advance Neutral On load change over switch I-O-II ,Current Rating 400 Amps, 415 Volts complete all as specified and directed.
59Supply only Diesel Filter suitable for 40 KVA to 100 KVA DG set complete all as specified and directed.
60Supply only Diesel Filter suitable for 200KVA to 320 / 380 KVA DG set complete all as specified and directed.
61Supply only Lube Oil filter suitable for 40 KVA to 100 KVA DG set complete all as specified and directed.
62Supply only Lube Oil Filter suitable for 200KVA to 380KVA DG set complete all as specified and directed.
63Supply only Airfilter suitable for 40 KVA to 100 KVA DG set complete all as specified and directed.
64Supply only Air Filter suitable for 200 KVA to 320 / 380 KVA DG set complete all as specified and directed.
65Supply & fixing of spare parts & accessories of original make for repair of DG set of capacity mentioned under Srl item No.2.01 to 2.03 here-in-before complete all as specified & directed by Engr-in-Charge. Note :- (i) All spares & accessories shall be fixed in the DG set only after prior inspection & approval of Engineer-in-Charge for which these shall be produced by the contractor at store yard of AGE E/M New Cant. (ii) Spare parts shall be measured & paid separately under respective items.
66Kit bypass filter
67Upper Gasket set (Cylinder head)
68Valve exhaust
69Valve inlet
70Valve seat Exhaust
71Valve seat Inlet
72Guide valve
73Collect Valve
74Spring valve
75Kit turbo charging
76Collar thrust
77Kit injector
78Kit Piston and ring set
79Kit Cylinder liner
80Kit Sump Gasket
81Gear pump assembly (Fuel pump FIP)
82Weight & carrier
83Barrel sleeve
84Gasket Set
85Suction filter
86Governor Pressure valve (Hydraulic Governor)
87Gear assembly
88Ball bearing
89Head gasket
90Nozzle
91Block
92Liner
93Battery terminal
94Packing Kit
95Crank
96Main bearing
97CR bearing
98Came bush
99Connecting Rod
100Rod balancing
101Bush
102Third washer
103Valve seal
104Supply & fixing of spare parts & accessories of original make for repair of DG set of capacity mentioned under Srl item No.2.04 to 2.07 here-in-before complete all as specified & directed by Engr-in-Charge. Note :- (i) All spares & accessories shall be fixed in the DG set only after prior inspection & approval of Engineer-in-Charge for which these shall be produced by the contractor at store yard of AGE E/M New Cant. (ii) Spare parts shall be measured & paid separately under respective items.
105Kit Fuel filter
106KitLube oil filter
107Kit bypass filter
108Kit Air cleaner
109Air filter
110Upper Gasket set (Cylinder head)
111Valve exhaust
112Valve inlet
113Valve seat Exhaust
114Valve seat Inlet
115Guide valve
116Collect Valve
117Spring valve
118Kit turbo charging
119Collar thrust
120Kit injector repair
121Kit Piston and ring set
122Kit Cylinder liner
123Kit Sump Gasket
124Gear pump assembly (Fuel pump FIP)
125Weight & carrier
126Barrel sleeve
127Gasket Set
128Suction filter
129Governor Pressure valve (Hydraulic Governor)
130Gear assembly
131Ball bearing
132Head gasket
133Nozzle
134Block
135Liner
136Battery terminal
137Packing Kit
138Crank
139Main bearing
140CR bearing
141Came bush
142Connecting Rod
143Rod balancing
144Bush
145Third washer
146Valve seal
147Dismantling ofDG Set Alternator of capacity 62.5 KVA / 63 KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M complete all as specified & directed. Note:- Necessary winding of alternator & repairing of armature shaft and required parts to be replaced shall be paid as supply only under respective items here-in-after.
148Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, nomex paper, cotton tape, glass sleeve, soldering rod, Grease etc complete all as specified & directed.
149Repairing ofarmature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete all as specified & directed.
150Supply only ball bearing at DE (Driven End) side of No.6310 complete all as specified & directed.
151Supply only rectifier diode for 63/62.5 KVA complete all as specified & directed.
152Supply only AVR (Automatic Voltage Regulator) for 63/62.5 KVA complete all as specified & directed.
153Supply only connection plate of suitable size for 63/62.5 KVA complete all as specified & directed.
154Dismantling ofDG Set Alternator of capacity 100/ 200/ 250 KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M complete all as specified & directed. Note:- Necessary winding of alternator & repairing of armature shaft and required parts to be replaced shall be paid as supply only under respective items here-in-after.
155Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, nomex paper, cotton tape, glass sleeve, soldering rod, Grease etc for 100/ 200/ 250 KVA DG set complete all as specified & directed.
156Repairing ofarmature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete all as specified & directed.
157Supply only ball bearing at DE (Driven End) side of No.6310 /6311/6312/6314 complete all as specified & directed.
158Supply only rectifier diode 100/200/250 KVA complete all as specified & directed.
159Supply only AVR (Automatic Voltage Regulator) 100/200/250 KVA size complete all as specified & directed.
160Supply only connection plate of suitable size complete all as specified & directed.
161Dismantling ofDG Set Alternator of capacity 15/25/40 KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M complete all as specified & directed. Note:- Necessary winding of alternator & repairing of armature shaft and required parts to be replaced shall be paid as supply only under respective items here-in-after.
162Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, nomex paper, cotton tape, glass sleeve, soldering rod, Grease etc for 15/25/40 KVA DG set complete all as specified & directed.
163Repairing ofarmature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete all as specified & directed.
164Supply only ball bearing at DE (Driven End) side of No.6310 /6311/6312/6314 complete all as specified & directed.
165Supply only rectifier diode complete all as specified & directed.
166Supply only AVR (Automatic Voltage Regulator) complete all as specified & directed.
167Supply only connection plate of suitable size complete all as specified & directed.
168S & F in repair MCCB 100 Amps, 415 Volts, 4 Pole, breaking capacity 16/25 KA, ISI marked, fix type complete all as specified & directed.
169S & F in repair MCCB 200 Amps, 415 Volts, 4 Pole, breaking capacity 25KA, ISI Marked, Fix / Adjustable type complete all as specified & directed.
170M&L for repair/overhauling of existing starter panel board of any size/type including cleaning with compressed air tightening of all electric connections to switches including repair/replacement of existing MCB/ switch fuse disconnect or units each of anyratingincluding testing complete with fixing of door (front & backside) with proper fixing & locking arrangement replacement of worn-out lugs, nut, bolts, internal wiring with suitable size (minimum 1.5 Sqmm) of PVC copper conductor wire and lugs, proper connection to main earth lead, to be provided/replaced as required at cable entries, fixing of door front & back with copper locking arrangement as required as site and painting with spray machine with super enamelled paint light grey paint in outer/ inner side of panel after cleaningand preparing surface including sign writing complete all as specified and directed. Note : Defective parts to be replaced& shall be measured and paid separately as supply only under respective item.
171Supply only contractor TF 34 make Siemens or equivalent approved
172Supply only contactor TF 30 Make Siemens or equivalents approved
173Supply only Contactor TF 31 Make Siemens or equivalents approved
174Supply only PVC Connector
175Supply only over Load Relay capacity 20-30 amp Make Siemens or equivalents approved
176Supply only over Load Relay capacity 10-20 amp Make Siemens or equivalents approved
177Supply only MCB TPN 63amps "C" series 415 Volt
178Supply only MCB TPN 32amps "C" series 415 Volt
179S & F in replacement of exhaust silencer complete with muffler of 100 KVA/62.5 KVA DG set complete & connect engine and DG silencer to drive away hot gases generated during operation of DG to atmosphere through silencer complete all as specified & directed.
180Dismantling and taking out the self starter,12 Volt DCfitted in 15to 62.5 KVA 3 phase 50 HZof DG setsand strip opening of self starter 12 Volt DC for carrying out repair/ servicing /overhauling mechanically ,cleaning, oiling/greasing/varnishing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, complete and re-assembling ofself starter 12 Volt DC after repair/ servicing /overhaulingand fixing the same in position and testing complete all as specified and directed .Notes :- (i)Repairs/servicing / reassembling and testing of Self starter 12 Volt DC shall be carried out through a authorised service centre .(ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts.The new replaced parts shall bemeasured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation toauthorized service centre & return back to site. (iv) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item.
181Supply only solenoid switch suitable for self starter, 12 Volt DC
182Supply only commutator suitable for self starter, 12 Volt DC
183Supply only carbon brush suitable for self starter, 12 Volt DC
184Supply only field coils suitable for self starter, 12 Volt DC
185Supply only bendix pinion assembly suitable for self starter, 12 Volt DC
186Supply only Bush suitable for self starter, 12 Volt DC
187Supply & fixing ofmicro processer start/stop control PCB panel for 250/100/62.5 KVA DG set including taking out unserviceable relay complete with following parameters Make: Kirloskar/ Greaves /Cummins (a)Individual phase current (Amps) (b) Phase voltages (V) (c ) Generator output frequency (Hz) (d) Engine water temperature (Deg.C) (e) Lube oil pressure (kpa) (f) Working hours (g) Push button (Starter) & (stop) (h) LED indications for main function
188Material & labour for replacement of unserviceable interconnection wiring and its interlocking system in AMF electric control panel for DG setwith using and including PVC insulated and unsheathed stranded copper conductor cable, single core, minimum 1.5 Sqmm size or as required 1100 Volts grade cable for making functional controls of the DG set, auxiliary contactor, push buttons, indicator, amps meter, volt meter complete as required at site for functioning of DG set in auto and manual mode, checking AC/DC circuits and removing & replacement of defective / unserviceable parts with new parts,complete all as specified and directed . Notes:(i) The complete panel shall be checked and tested on full load after necessary repairs and replacement of unserviceable wiring. for its smooth functioning and proper interlocking including shut down on high water temperature and low Oil pressure. (ii)All control wires shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of copper lugs. the cost of same are deemed to include under these items.(iii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts.The new replaced parts shall bemeasured and paid separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc.(iv) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item.
189Supply only electronic timer, on delay type, dual range, suitable of 220 Volts/ 24 Volts, 2NO+2NC, 50 Hz, AC supply/ DC supply, for 0-60 seconds.
190Supply only Power contactor 3 polewith 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC 3 rating 300/325/330 Amps. Complete all as specified and directed .
191Supply only Power contactor 3 polewith 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC 3 rating 400 Amps. Complete all as specified and directed .
192Supply only Power Contactor No volt coil suitable for 400Amp Contactor
193Supply only Power Contactor No volt coil suitable for 300/325/330 Amp Contactor
194Supply only Auxiliary relay 8 pin, 24 Volts ,DC , 2 change over.
195Supply only Auxiliary relay 8 pin, 220 Volts , AC , 2 change over.
196Supply only Bimetal under volt / over volt relay suitable for 3 phase, 3 wire with 2 NO+2NC auxiliary contacts
197Supply only Engine starting relay with sequence timer & Master timer suitable for 12 / 24 Volts DC supply.
198Supply only Selector switch 3 way for auto manual operation .
199Supply only Selector switch 4 way for operation of volt meters & Ammeter.
200Supply only Indicating lamps LEDtype with holderfor 12 / 24 volts DC supply
201Supply only Digital electronic ammeter double ratio with 5 Amps secondary current of any range, flush pattern sequence type size 96 mm X 96 mm suitable for existing CT ratiofor maintaining on 415 Volts built in selector switch
202Supply only Digital electronic volt meter 0-50 V range suitable for 12 / 24 volt DC supply panel flush pattern square type size 96mm X 96mm
203Supply only Digital electronic volt meter 0-500 V range suitable for 415 Volts panel flush pattern square type size 96mm X 96mm
204Supply only Digital electronic Frequency meter 40-99.99 HZ built in selector switch, suitable for 415 Volts panel flush pattern square type size 96mm X 96mm
205Supply only HRC fuse DIN type with base for AC circuit 415 volts having rating of 400 Amps .
206M & L for cleaning of MS fuel tank of DG sets of 100 to 300 ltr capacity by collecting the fuel in cleaned barrels and removing sludge deposited/accumulated inside the tank of and disposal of sludge at a distance not exceeding 100 metre and cleaning the tank with kerosene oil including replacement of fuel tank strainer and unserviceable fuel gauge with new PVC fuel level indicator fixed with clips to the tank and marking levels for every 10 litre by marking and numbering on the side of fuel tank with synthetic enamelled paint and refilling the collected fuel after filtration complete all as specified and directed.
207Section "B" ( Mechanical Loundary)
208S&F in replacement on load change over switch (side handle) in sheet enclosure 415 V AC 50 Hz 100 Amps capacity including necessary connections with suitable size aluminium conductor cable and lugs complete all as specified and directed
209S&F in replacement on load change over switch (side handle) in sheet enclosure 415 V AC 50 Hz 200 Amps capacity including necessary connections with suitable size aluminium conductor cable and lugs complete all as specified and directed
210S&F in replacement of DOL Starter three phase 415V suitable for 5 HP motor including connection and fixing completed all as specified and directed
211Quarterly Periodical, preventive and comprehensive maintenance of hydraulic pump of steam boiler for lifting of water to steam coil and overhauling of hydraulic pump of steam boiler includingreplacement of head valve seat, fibre gland copper bush, repairing of connecting rod, replacement of bearing and bush of required size complete in all respect all as specified and directed.
212Quarterly Periodical, preventive and comprehensive maintenance by de-scaling of boiler with high pressure descaling pump of 600 Kg/hour boiler capacity by using suitable chemical powder including necessary T&P arrangement as required at site complete all as specified and directed
213S & F in replacement of FRP Vessel pentair of capacity 1000 ltrs per hours including connection with existing system complete all as specified and directed.
214Quarterly periodical and preventive servicing of industrial RO Plant disconnecting piping arrangement including cleaning washing complete all as specified and directed
215M & L forOpening the vessel painter and taking out old filter media and filling for new sand and carbon filter media all as directed.
216S& F in replacement of Membrane filter for 500ltr/hrs capacity RO plant complete all as specified and directed.
217S & F in replacement ofpump 1/2 HP 230 voltscomplete with inlet & out let valve 20/25 mm dia complete all as specified and directed.
218S & F in replacement of Anti scalantfilterfor 500ltr/hrs capacity RO plant complete all as specified and directed.
219S & F jumbo housing complete all as specified and directed
220S & F solenoid valve 20/25 mm dia complete all as specified and directed.
221S & F in replacementHigh pressure vertical pump for RO plant 1000 ltr/hrs complete all as specified and directed.
222Material & labour in replacement of steam coil of boiler of material of BS 3059 including re-fixing cover plate, photocell, nozzle, hose connection, pipe lineetcof oil fired boiler incl all connection complete all as specified and directed
223Supply & replacement ofall hoses of fuel pump, calibration of fuel pump, setting of valve for proper delivery of fuel to the nozzle complete all as specified & directed
224Checking & repairing of 30 Kg/cm air compressor, by oiling, greasing and servicingincluding painting with one coat of synthetic ennamalled paint complete all as specified and directed.
225Material and labour for rewinding of 3 HP motor 3 phase, 415 volt incl painting with one coat of synthetic ennamalled paint complete all as specified and directed.
226Opening, checking, repairing & cleaning of boiler economiser, decarbonising of tubes, brushing, flushing of outer dia and inner dia of tubes and refixing incl replacement of worn-out gasket, nut, bolts etc. at both end, cleaning of chimney complete all as specified & directed.
227Quarterly Periodical, preventive and comprehensive maintenance of 30 Kg washer extractor for proper functioning, repair/replacement of temperature controller, sensor, limit switch, hydraulic locking device, electrical locking device, V belt ribbed type including adjustment of bush after replacement of belt, oiling/greasing and alignment of motor with proper tightening of belts complete all as specified & directed
228Quarterly Periodical, preventive & comprehensive maintenance by disconnection, dismantling & taking out all mechanical/electrical/electronic circuit connections old steam roller ironer, removing of hot iron steam plate, taking out roller from machine, repairing of uneven surface of base material and damage sheet cover cloth, refixing of base material/parts including replacement of new cloth cover as per sample of 20 mtrs length on roller base material, stitching of canvas cloth & refixing of pedestal roller on machine & re-fixing of all electrical/electronic/mechanical connection & testing of machine complete all as specified & directed
229S & F in replacement ofCR steel scrap for wrappingsurrounding the roller complete all as specifiedand directed.
230Repair, servicing, calibration and programming of variable frequency drive including replacement of minor parts as required and rewiring of control wiring complete all as specified & directed. i.e. FABCARE/FABTECH Engg .
231Repair and replacement of PLC unit suitable for washer extractor complete all as specified and directed.
232Repair and replacement of HMI unit suitable for washer extractor (touch screen type) complete all as specified and directed.
233S & F in replacement of industrial ironing machine complete with ironing table and piping arrangement complete all as specified and directed.
234SECTION "C" ( FIRE HYDRANT, DIESEL PUMP & JOCKEY PUMP AND ITS CONNECTED ITEMS)
235S&F in repair fire hydrant landing valve type A Single headed outlet of63mm dia conforming to IS 5290 complete all as specified and directed.
236S&F in repair fire hydrant landing valve type B double headed outlet of 63mm dia conforming to IS 5290 complete all as specified and directed.
237S&F in repair hose pipe box for keeping 2 Nos hose pipeof length 15 mtr each branch pipe nozzle coupling etc of MS sheet of thickness 2mm complete all as specified and directed.
238S&F in repair 63mm dia hose 15 mtr long hose conforming to IS-636 complete with male and female coupling conforming to IS-903 complete all as specified and directed.
239S&F in repair fire hydrant stand post with provision of single outlet conforming to IS-908 complete all as specified and directed.
240Repair and replacement of worn-out partsafter taking out from installation shifting to civil workshop rewinding motor cleaning greasing and refitting at installation to electric driven jockey motor withpumps delivering 180 LPM upto 70 mtr head complete all as specified and directed.
241Repair & maintenance of diesel engine driven fire pumphorizontal end suction, complete servicing/overhauling and replacement of all warn out parts centrifugalci casing and bronze impeller stainless steel shaft suitable for delivering 1620 LPM 70 mtr head, 1800RPM complete all as specified and directed.
242Supply and replacement of 80/100 mm bore MS flanged heavy duty pipe for multi storied bldg duly painted complete all as specified and directed
243Supply, installation, testing and commissioning in replacement ofindoor type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and CPRI approved manufacturerfactory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gasket to make it dust and vermin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable andduly compartmentalized for each control gears. The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity 400 Amps of the incomer MCCB. The panel should have the following incoming and outgoing controls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. Note:- PCC platform of suitable size for mounting the LT Panel is deemed to be included in the quoted rate.
244M&L for earthingwith galvanised earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised iron wire 4 mm dia as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm bore GI pipe medium grade for watering with alternate layer of char coal dust and salt including all accessories like nut bolts, reducer, nipple wire mesh/screened funnel and making brick machinery finished chamber of intern size 300x300x300mm with concrete base covered with a cost iron hinged cover resting over the cost iron frame painted with black bituminous paint which shall be imbedded in the block machinery including excavation work refilling connecting to main switch/MCB DB for feeding the electric supply all as specified and directed and shown in electrical plate No. 3 of SSR Part-I and testing the earth resistance as required complete all as specified and directed.
245Supply, fixing & testing in replacement of oil pump of capacity 60/62.5 KVA DG Set including replacement ofall other connected items complete all as specified and directed.
246Supply, fixing & testing in replacement of oil pump of capacity 100 KVA DG Set including replacement of all other connected items complete all as specified and directed.
247Supply, fixing & testing in replacement of oil pump of capacity 320 KVA DG Set including replacement of all other connected items complete all as specified and directed.
248Schedule of Credit (MINUS) Rs. 1,17,282.00 B/F from Serial Page No.[Note : Detailsof items for schedule of credit is given on Srl Page No. ] This amount shall be automatically deducted to arrive at tendered sum
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail