Tender For Certain Repair Maintenance Of Deep Freezer, Water Cooler, Window / Split Ac Etc In Zone B And C Area Under Age Em Of Ge ( East ) Jabalpur. ; 1 Comprehensive Maint Of Window Type / Split Type Air Conditioner Of Capacity 1.5 / 2 Ton Including Taking Out, Reinstalling After Repairing, Cleaning, Servicing, Oiling In Moveable Parts And Charging Of Refrigrent Gas If Required Including Testing, Comissioning And Quarterly Servicing Of Each Air Conditioner And In Between Period As An When Required Machanic Will Visit For Minor Repair Such As Electric Connections, Replacement Of Small Size Of Wire, Cleaning Of Filtertill Completion Of Work Complete All As Specified And Directed. Note :- ( I ) Cost Of Refrigrent Gas And Necessary Spare Parts Shall Be Paid Separately. ( Ii ) No Extra Payment Will Be Made To The Contractor For Machanic Visit. 2 Servicing, Maintenance And Repairs To Refrigerator / Deep Freezeof Capacity Up To 500 Ltrs Of Any Make And Model Including Periodical Cleaningto Condenser Coil And Compresser Complete All As Specified And Directed.Note : Replacement Of Defective Spares Shall Be Measured And Paid Separately Under Relevant Items As Under 3 Comprehensive Maintenance Of Water Cooler Of Any Make, Any Type And Any Capacity After Disconnecting Inlet, Outlet Drain Pipe And Reinstalling, Connecting The Same After Repairing Including Taking Out, Reinstalling After Repairing, Servicing, Cleaning Of Water Tank And Charging Of Refrigrent Gas If Required Including Testing, Comissioning And Quarterly Servicing Of Each Water Cooler And In Between Period As An When Required Machanic Will Visit For Minor Repair Such As Electric Connections, Replacement Of Small Size Of Wire, Cleaning Of Inner Tank Till Completion Of Work Complete All As Specified And As Directed. Note : ( I ) Cost Of Refrigrent Gas And Necessary Spare Parts Shall Be Paid Separately. ( Ii ) No Extra Payment Will Be Made To The Contractor For Machanic Visit. 4 S&F In Repair Sealed Unit Compressor Suitable For Window Type / Split Type Air Conditioner Of 1.5 Ton Capacity, Cutting Of Suction And Discharge Copper Tubes Including Breezing, Jointing, Testing Andcommissioning Complete All As Specified And Directed. Note : Cost Of Refrigrent Gas Shall Be Paid Under Relavent Item. 5 S&F In Repair Sealed Unit Compressor Suitable For Split Type Air Conditioner Of2 Ton Capacity, Cutting Of Suction And Discharge Copper Tubes Including Breezing, Jointing, Testing Andcommissioning Complete All As Specified And Directed.Note : Cost Of Refrigrent Gas Shall Be Paid Under Relavent Item. 6 S&F In Repair Sealed Unit Compressor Suitable For Water Cooler Of 40 / 80 Litres Capacity, Cutting Of Suction And Discharge Copper Tubes Including Breezing, Jointing, Testing Andcommissioning Complete All As Specified And Directed.Note : Gas For Charging Shall Be Measured And Paid Under Relavent Item. 7 S&F In Repair Sealed Unit Compressor Suitable For Water Cooler Of 60 / 120 Litres Capacity, Cutting Of Suction And Discharge Copper Tubes Including Breezing, Jointing, Testing Andcommissioning Complete All As Specified And Directed.Note : Gas For Charging Shall Be Measured And Paid Under Relavent Item. 8 S&F In Repair Sealed Unit Compressor Suitable For Water Cooler Of 20 / 20 Litres Capacity, Cutting Of Suction And Discharge Copper Tubes Including Breezing, Jointing, Testing Andcommissioning Complete All As Specified And Directed.Note : Gas For Charging Shall Be Measured And Paid Under Relavent Item. 9 S&F In Repair Pcb ( Printed Control Board ) With Remote Control Operation And Sensor For Window Type Ac / Split Type Ac / Multi Split Ac 1.5 / 2.0 Tr For Any Type Of Model As Per Sample Received From Site In Presence Of Mes Representative Complete All As Specified And Directed. 10 S&F In Repair Pcb ( Printed Control Board ) With Remote Control Operation And Sensor For Outdoor Unit Of Inverter Typesplit Ac 1.5 / 2.0 Tr For Any Type Of Model As Per Sample Received From Site In Presence Of Mes Representative Complete All As Specified And Directed. 11 S&F In Repair Pcb ( Printed Control Board ) With Remote Control Operation And Sensor For Indoor Unit Of Inverter Typesplit Ac 1.5 / 2.0 Tr For Any Type Of Model As Per Sample Received From Site In Presence Of Mes Representative Complete All As Specified And Directed. 12 S&F In Replacement Of Unserviceable Starting Capacitor Of 80-100 Mfd Capacity 220-240 Volts Including Taking Down Old ( Starting Capacitor For Water Cooler ) Complete All As Specified And Directed. 13 S&F In Replacement Of Unserviceable Starting Capacitor Of 40-60 Mfd Capacity 220-240 Volts Including Taking Down Old ( Starting Capacitor For Water Cooler ) Complete All As Specified And Directed. 14 S&F In Replacement Of Unserviceable Running Capacitor 220-240 Volts, 50 Hzof 36-4 Mfd Capacity Including Taking Down Old Running Capacitor ( Suitable For Air Conditioner / Water Cooler ) Complete All As Specified And Directed. 15 S&F In Replacement Of Unserviceable Running Capacitor 220-240 Volts, 50 Hzof 45-6 Mfd Capacity Including Taking Down Old Running Capacitor ( Suitable For Air Conditioner / Water Cooler ) Complete All As Specified And Directed. 16 S&F In Replacement Of Unserviceable Running Capacitor 220-240 Volts, 50 Hzof 50-6 Mfd Capacity Including Taking Down Old Running Capacitor ( Suitable For Air Conditioner / Water Cooler ) Complete All As Specified And Directed. 17 S&F In Replacement Of Unserviceable Running Capacitor 220-240 Volts, 50 Hzof 60-4 Mfd Capacity Including Taking Down Old Running Capacitor ( Suitable For Air Conditioner / Water Cooler ) Complete All As Specified And Directed. 18 S&F In Replacement Of Unserviceable Relay Suitable For 1.5 / 2 Ton Capacity Split Type Ac Of Any Type And Any Make As Per Sample / Make Received From Site In Presence Of Mes Representative Would Be Make To Be Replaced All As Specified And Directed. 19 S&F In Replacement Of Unserviceable Over Load Protector For Water Cooler Of Any Capacity, Any Type And Any Make As Per Sample / Make Received From Site In Presence Of Mes Rep Would Be Make To Be Replaced Complete All As Specified And Directed. 20 S&F In Replacement Of Unserviceable Over Load Protector For 1.5 / 2 Ton Capacity Split Type Ac, Any Type And Any Make As Per Sample / Make Received From Site In Presence Of Mes Representative Would Be Make To Be Replaced Complete All As Specified And Directed. 21 S&F In Replacement Of Rotory Compressor Of Same Make And Capacity Of Replaced One, All Per Site Requirement For 1.5 Ton Capacity Ac, Complete All As Specified And Directed. Make-Tecumseh / Highly / Gmc 22 S&F In Replacement Of Rotory Compressor Of Same Make And Capacityof Replaced One, All Per Site Requirement For 2 Ton Capacity Splitac, Complete All As Specified And Directed.Make-Tecumseh / Highly / Gmc 23 S&F In Replacement Of Condenser Fan Motor For Indoor Unitof Same Make And Capacityof Replaced One, All Per Site Requirement For 1.5 Ton Capacitysplit Ac, Complete All As Specified And Directed. 24 S&F In Replacement Of Condenser Fan Motor For Indoor Unitof Same Make And Capacityof Replaced One, All Per Site Requirement For 2 Ton Capacity Split Ac, Complete All As Specified And Directed. 25 S&F In Replacement Of Condenser Fan Motor For Outdoor Unit Of Same Make And Capacityof Replaced One, All Per Site Requirement For 1.5 Ton Capacity Splitac Complete All As Specified And Directed. 26 S&F In Replacement Of Condenser Fan Motor For Outdoor Unitof Same Make And Capacityof Replaced One, All Per Site Requirement For 2 Ton Capacity Split Ac Complete All As Specified And Directed. 27 S&F In Replacement Of Split Ac Outdoor Unit Without Compressor Completewith All Accessories ( Copper Condenser Coil, Propeller Fan, Condensor Fan Motor Etc ) Of Same Make And Capacity Of Replaced One, All Per Site Requirement For 1.5 Ton Capacity Ac Complete All As Specified And Directed. 28 S&F In Replacement Of Split Ac Outdoor Unit Without Compressor Completewith All Accessories ( Copper Condenser Coil, Propeller Fan, Condensor Fan Motor Etc ) Of Same Make And Capacity Of Replaced One, All Per Site Requirement For 2 Ton Capacity Ac Complete All As Specified And Directed. 29 S&F In Replacement Of Water Cooler 40 / 80 Ltr Copper Condensor Coil Complete With All Accessories, All As Per Site Requirement For Any Capacity / Any Type Water Cooler Complete All As Specified And Directed. 30 S&F In Replacement Of Water Cooler 60 / 120 Ltr Copper Condensor Coil Complete With All Accessories, All As Per Site Requirement For Any Capacity / Any Type Water Cooler Complete All As Specified And Directed. 31 S&F In Replacement Of Water Cooler 20 / 40 Ltrcopper Condensor Coil Complete With All Accessories, All As Per Site Requirement For Any Capacity / Any Type Water Cooler Complete All As Specified And Directed. 32 S&F In Replacement Copper Condensor Coil Of Split Ac Outdoor Unitcomplete With All Accessories, All As Per Site Requirement For 1.5 Ton Capacity Ac Complete All As Specified And Directed. 33 S&F In Replacement Copper Condensor Coil Of Split Ac Outdoor Unitcomplete With All Accessories, All As Per Site Requirement For 2.0 Ton Capacity Ac Complete All As Specified And Directed. 34 S&F In Replacement Of Split Ac Indoor Unit Complete With All Accessories ( Cooling Coil, Blower Motor, Swing Motor, Pcb, Etc ) Ofsame Make And Capacity Of Replaced One, All Per Site Requirement For 1.5 Ton Capacity Ac Complete All As Specified And Directed. 35 S&F In Replacement Ofunserviceable Brass Flare Nut For Joint Discharge Section Of Indoor And Outdoor Unit Of 1.5 / 2 Ton Air Conditoner Any Type And Any Make Complete All As Specified And Directed. 36 S&F In Replacement Of Rusted Outdoor Mounting Stand Set With New One For Outdoor Unit Ofsplit Type Ac Including Nuts, Bolts & Wahers Complete All As Specified And Directed. 37 S&F Drain Hose Pipe For 1.5 / 2 Ton Ac Complete All As Specified And Directed. 38 S&F Swing Motor Suitablefor 1.5 / 2 Tonac Complete All As Specified And Directed. 39 S&F Coil Sensor And Air Sensor Suitablefor 1.5 / 2 Tonac Complete All As Directed. 40 S&F In Replacement Of Unserviceable Pvc Sleeves Of Size 5 / 8 Or 1 / 2 Or 1 / 4 With Taflon Tape For Copper Tubing Of Split Type Air Conditioner From Indoor Unit To Out Door Unit As Per Requirement Received Complete All As Specified And Directed. 41 S&F In Replacement Of Unserviceable Dry Filter Of Silica Gel Suitable For Any Capacity Window / Split Type Air Conditioner Complete All As Specified And Directed. 42 S&F In Replacement Of Unserviceable Propellerfan Blade Suitable For Window / Split Type Air Conditioner For Outdoor Unit Of Any Capacity 1.5 / 2.0 Ton For Lg / Voltas Preferably Complete All As Specified And Directed. 43 S&F In Replacement Of Unserviceable Propellerfan Blade Suitable For Water Cooler Compressor Unit Any Type And Any Capacity Complete All As Specified And Directed. 44 S&F In Replacement Of Unserviceable Chromium Plated Cock Of 15Mm Dia For Water Cooler Self Close Type Complete All As Specified And Directed. 45 S&F In Replacement Of Unserviceablethermostate Suitable Forwater Cooler Of Any Make And Any Capacity Complete All As Specified And Directed. Make-Annpurna / Ranutrol 46 Supply And Charging Of Gas F-22 / R-32 / R-134 A ( Freon ) Suitable For Water Cooler / Window Or Split Ac Any Type Complete All As Specified And Directed. 47 S&F In Replacement Of Unserviceable Copper Tube Of Size 5 / 8 Or 1 / 2 Or 1 / 4 Or 5 / 16 ( Suction / Discharge Line Copper Tube ) For Window / Splita / C Of Any Make And Any Type Complete All As Specified And Directed. 48 S&F In Replacement Offloat Valve For Exclusive Suitable For Water Cooler Of Existing Size Of Any Make And Any Type Complete All As Specified And Directed. 49 S&F In Replacement Ofdoor Gasket For Water Cooler Of Any Make And Any Size Complete All As Specified And Directed. 50 S&F In Replacement Ofunserviceable Blower Motor For Lg / Voltas 1.5 / 2.0 Ton Air Conditioner Ofcapacity 0.038 Hp ( 29 Watt ) / 0.024 Hp ( 18 Watt ) / 0.048 Hp ( 36 Watt ) , 240 Volt, 50 Hz ( Suitable For Air Conditioner ) & Testing Complete All As Specified And Directed.Note : 6 Pices For Each Type Of Capacity. 51 S&F In Replacement Ofunserviceable Condensor Motor Suitable For 20 / 40 / 60 Litre Water Cooler Ofcapacity 1 / 35 Hp Or 1 / 85 Hp, 240 Volt, 50 Hz ( Suitable For Water Cooler ) & Testing Complete All As Specified And Directed.Note :6 Pices For Each Type Of Capacity. 52 S&F In Repair Steel Sheetenclosure ( Body Cover ) Suitable For Window Type Air Conditioner Of Capacity 1.5 Ton Complete All As Specified And Directed. 53 S&F In Repair Cooling Coil For 1.5 / 2.0 Ton Capacity Lg / Voltas Split Type Accomplete All As Directed.Note : 02 Pieces For Each Type Of Capacity. 54 Comprehensive Maint Of Desert Cooler Of Any Make / Type Cleaning / Overhauling, Greasing Of Fan Motor, Fan And Checking Electric Connection And Reconnecting The Electric Connection Complete All As Directed. Note :Items Required To Be Replaced, Over Hauling& Rewinding Of Fan Motor If Required Shall Be Measured And Paid Separately. 55 Removing Thefan Motor Of Desert Cooler And Removing The Burnt Winding And M&L For Rewinding The Same With Supper Enamelledcopper Wire Of Existing Size, Gauge And Turns Including Cleaning The Slots Properly, And Testing Complete All As Specified And Directed. 56 S&F Electronic Fan Regulator Stepped Type Of Capacity Not Less Than 80 Watts Single Phase 230 Volt Suitable For Desert Coolers Complete All As Specified And Directed. 57 S&F Front Grill Suitable For Desert Cooler Of Any Make Any Type Complete All As Specified And Directed. 58 S&F Pvc Switch Board Assembly For Desert Cooler Including 5 Amps Switch - 02 Nos And Indicator Lamps Complete All As Specified And Directed. 59 S&F In Replacement Of Unserviceable Metal Fan Blade Suitable For Desert Cooler Any Type And Any Capacity Complete All As Specified And Directed. 60 S&F In Replacement Of Unserviceable Khas Pads / Wood Wool Pad Of Required Size For Desert Cooler Of Any Make Complete All As Specified And Directed. 61 S&F In Repair Of Fan Motor Of Copper Winding With Metal Blade Suitable For Desert Cooler Of Any Type / Capacity Single Phase, 230 Volt Complete All As Specified And Directed.Make- Crompton / Khaitan / Gec / Bajaj 62 S&F Sheet Metal Enclosure Single Pole And Neutral With A Two Pin And Earth Plug And Socket Complete With & Including Onesingle Pole Mcb 20 Amps Complete All As Specified And Directed.Make : Siemens / Legrend / Schneider 63 S&F In Replacement Ofunserviceablesubmersible Water Lifting Pump For Desert Cooler, 240 Volts, 50 Hz, Ac, 12 Watt, 1.5 Metres Max Head And Output : 800 Lph Complete All As Specified And Directed.Make-Crompton / Alstrom Or Equivalent 64 S&F Compressor Unitfor Deep Freezer Hard Top Capacity 300 / 320 Ltrs Complete All As Specified And Directed. Make:- Kcj412 Of Copland / Tecumseh Or Equivalent 65 S&F Compressor Unitfor Deep Freezer Hard Top Capacity 500 Ltrs Complete All As Specified And Directed. Make:- Kcn415 Of Copland / Tecumseh Or Equivalent 66 S&Fthermostat, 230 Voltfor Deep Freezer Hard Top Capacity 300 / 500 Ltrs Complete All As Specified And Directed. 67 S&F Compressor Suitable For 340 Ltrs Frost Free Refrigerator Complete All As Specified And Directed. 68 S&F Compressor Suitable For 340 Ltrs Frost Free Dc Inverter Refrigerator Complete All As Specified And Directed. 69 S&F Pcbsuitable For 340 Ltrs Frost Free Refrigerator Complete All As Specified And Directed. 70 S&F Timer Suitable For 340 Ltrs Frost Free Refrigerator Complete All As Specified And Directed. 71 S&F Cooling Fan Motorsuitable For 340 Ltrs Frost Free Refrigerator Complete All As Specified And Directed. 72 S&F Defrost Heater Suitable For 340 Ltrs Frost Free Refrigerator Complete All As Specified And Directed. 73 S&F Bimetal Strip Suitable For 340 Ltrs Frost Free Refrigerator Complete All As Specified And Directed. 74 S&F Thermostat Suitable For 340 Ltrs Frost Free Refrigerator Complete All As Specified And Directed. 75 Note:- ( I ) The Contractor Will Collect The Complaint Slip In Every Morning Of Working Day At 09:30 Hrs And Will Ensure Best Effort To Attend The Complaint From The Je E / M / Age E / M Moreover The Complaints Of Cooling Appliances To Be Attended On The Same Day On Receiving Verbally Or By Any Other Source And The Completion Report To Be Submitted Duly Signed By User To The Respective Section Or Je E / M. ( Ii ) If Contractor Fails To Attend Even Within 24 Hrs Time Then Penal Recovery Of 500 / - Per Day For Each Complaint Will Be Made From Contrator Dues. ( Iii ) The Contractor Will Ensure To Compliance The Requirement Strictly As Described Above For Smooth Functioning Of All Cooling Appiances And Contractor Are Advise To Quote Their Rates To All Aboveitems To Kept In Mind Mentioned Vide Sl No. ( I ) & ( Ii ) In This Aspect.Further No Extra Claim In This Regard Will Be Admissible To Contractor. 76 Schedule Of Credit Amount Of Rs. 31, 314.00 To Be Deducted During Aoc.