BOQ
| Sl. No. | Item Description |
| 1 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches including all T & p etc complete |
| 2 | Same as item no 1 but for depth 1.50 mtr. To 3.0 mtr. Depth |
| 3 | Same as item no 1 but for depth 3.0 mtr. To 4.50 mtr. Depth |
| 4 | Filling of carted earthincluding supply of necessary quantity of earth from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 5 | Cement concrete with 4 CM guage approved stone ballast approved coarse sand and cement in the proportion of 8:4:1 including supply of all material labour and tools and plants etc required for proper completion for the work. (PWD SOR- S.I. NO-281) |
| 6 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work.(excluding royality) |
| 7 | Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete.(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer\"s standard dilution) |
| 8 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in Foundation excluding supply of reinforcement and its fixing and binding the same with 24 BWGGI binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being included in the item. |
| 9 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lighter beam excluding supply of reinforcement and its fixing and binding the same with 24 BWGGI binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being included in the item. |
| 10 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWGGI binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. |
| 11 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in slab excluding supply of reinforcement and its fixing and binding the same with 24 BWGGI binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being included in the item. |
| 12 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in Column excluding supply of reinforcement and its fixing and binding the same with 24 BWGGI binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being included in the item. |
| 13 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including binding for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured. |
| 14 | M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 15 | M-150 brick work in 1:4 (one cement and four coarse sand) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 16 | 40mm thick damp proof course with cement concrete consisting of 1:1.5:3 one part cement 1.5 parts approved coarse sand and 3 parts approved 13mm graded stone grit and including water proofing material as orderd by the Engineer in charge in the proportion as specified by the manufactures including supply of all material labour T & P etc required for the proper completion of the work and including proper curing and shuteering as necessary. |
| 17 | Painting on DPC with two coats of air blown bitumen 8/50 or 85/25@ 1.7 kg/Sqm approx including cost of fuel if any. |
| 18 | M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortarin super-structure includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) |
| 19 | M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortarin super-structure includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall less than 12cms. (1:6 cement : coarse sand) |
| 20 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) soliddecorative type flush door shutter of required size comprising of virgin polymer of K value58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 35 mm thick |
| 21 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) soliddoor/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVCpolymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 45 x 85 mm |
| 22 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 23 | Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws 35 mm thick shutters With ISI marked stainless steel butt hinges of required size Second class teak wood |
| 24 | Providing and fixing of 4.5 cm (1.3/4\") thick c.p. teak wood part panelled or panelled and glazed shutters for doors, windows and clerestory windows shutters includingfixing of wooden cleates and stops and including fixing & adjustment ofbutt hinges , bolts locks handels of or other fittingsbut excluding their supply and including painting with with two coats of of black japan on all iron fitting if necessary & Including fixinig the glass panes with putty & Bard glass to be 0.64 kg |
| 25 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
| 26 | Mild steel or iron workofsmall sizes and sections suchas holding down bolts, holdfast tierods, gratings etc.(when not included in and over all rates) brought to requiredfrom including supply of steel & its wastage including cost of bolts,nuts,if required forand welding,grinding and making holes as required for proper completion of the work. Fabrication of grill/stairs case railing |
| 27 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). |
| 28 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.Second class teak wood 30 mm thick shutters |
| 29 | 12 mm thick Plinth plaster with cement mortar 1:4 consisting of 1 part cement and 4 part of approved coarse sand of Minimum thickness not to be less than 10 mm .Including supply of all materials , labour and T&P etc requried for proper complition of the work (plinth plaster) |
| 30 | 12mm thick plaster with cement mortar consisting of 1 part cement and 6 part of approved coarse sand minimum thickness not to be less than 10mm including supply of all material labour & T & P etc required for proper completion of work.external |
| 31 | 12mm thick plaster with cement mortar consisting of 1 part cement and 6 part of approved coarse sand minimum thickness not to be less than 10mm including supply of all material labour & T & P etc required for proper completion of work. |
| 32 | Making grooves 10 to 12mmwide x 8 mm deep inplaster of the walls or in ceiling vertically or horizontally as required. |
| 33 | Providing and laying vitrified floor tiles(300x300) in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete (Anti Skid Vitrified flooring) |
| 34 | Providing and laying vitrified floor tiles Kajaria KERRO Brand or equivalent brand of super quality in diffrent size (thickness specified by manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 35 | Supply & fixing ceramic tiles in flooring laidof 10 mm cement mortar in flooringwith 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all material labour and T & P et required of proper completion of the work. |
| 36 | Supply & fixing 6mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all material labour and T & P et required of proper completion of the work. |
| 37 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble Area of slab upto 0.50 sqm |
| 38 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Polished Granite stone slab colour of Black, Cherry/RubyRed or equivalent |
| 39 | Painting or varnishing new steel work in small areas or new wood with one coat (up to one sq. meter) of ready mixed priming paint and one coat of approved superior quality ready mix paint (2nd quality synthetic enamel paint of approved brand such as British paint shalimar Asian or equivalent supply of all material labour T & P etc required for proper completion of work.Paint to be used should confirm the ISI No. 103-1950 |
| 40 | Painting or varnishing new wood work in small areas or new wood with one coat (up to one sq. meter) of ready mixed priming paint and one coat of approved superior quality ready mix paint (2nd quality synthetic enamel paint of approved brand such as British paint shalimar Asian or equivalent supply of all material labour T & P etc required for proper completion of work.Paint to be used should confirm the ISI No. 103-1950 |
| 41 | Melamine polishing on wood work (one or more coat). |
| 42 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 43 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 44 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 45 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes |
| 46 | Providing & fixing Stainless steel Sliding bolts with nuts & bolts (Bolt 16mm dia 250mm long) |
| 47 | Providing & fixing Stainless steelTower bolts with nuts & bolts (Bolt 10mm dia 250mm long) |
| 48 | Providing & fixing Stainless steelhandles with screws etc. complete (a) 150 mm |
| 49 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b)Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e)The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge With average thickness of 120 mm and minimum thickness at khurra as 65 mm |
| 50 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and lerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 2nd class teak wood beading 62X19 mm |
| 51 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, platesetc., including welding, grinding, bufÏng, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 52 | 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction CoefÏcient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 53 | Cement concrete with 2 CM guage approved stone ballast approved coarse sand and cement in the proportion of 4:2:1 including supply of all material labour and tools and plants etc required for proper completion for the work. |
| 54 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 55 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer GODREJ OR EQUIPMENT |
| 56 | Glass fibre Reinforced concrete ( GRC JALI ) grade -10 including supply of all material labour and tools and plants etc. required for proper completion for the work. |
| 57 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry |
| 58 | 25mm thick 1:2:4 cement concrete floor with cement approved coarse sand and 2 cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cementfinish including supply of all materials labour T & P etc required for proper completion of the work. |
| 59 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 1729 |
| 60 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar |
| 61 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 62 | 2 cm thick cement plaster in dado or skirting in 1:2 consisting of one part of cement and 2 parts of approved coarse sand laid in panels finished with 3 mm floating coat of neat cement or cement & marble dust in ratio of 5:1 including supply of all materials labour & t & P etc equired for proper completion of the work. |
| 63 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls, floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow, bend, tee and y-tee including supply of al marerial labour and T&P required for proper completion of work. 160 mm dia |
| 64 | Hanching of SWR pipe with PCC 1:2:4 ( 1 cement: 2 coarse sand: 4 stone grit) of cross section 200 x 200 mm concrete P.V.C./ S.W.R Pipes including conccrete for bedding necessary form work and curing complete 160 mm dia |
| 65 | Constructing brick masonry manhole with 150 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement :4coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4(1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.Inside size 60x60 cm & 75 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg. |
| 66 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter |
| 67 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually.Drilling of 300mm dia bore hole manually. |
| 68 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia 150 mm nominal size dia |
| 69 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge |
| 70 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge |
| 71 | Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 72 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 73 | Development of boring of compressor |
| 74 | Laying Of C.C Road Slab 150 Mm Thick Consisting Of 1:1.5:3 Cement:Coarse Sand :20 Mm Gauge StoneBallast Over Prepared Sub Grade After Its Rectification And Bringing It To Proper Camber And Including Supply Of All Material ,Labour T And P Etc Complete |
| 75 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade \"A\" sealing compound. |
| 76 | P & L of Interlocking Concrete Block Pavement having80mm thicki/c levelling & dressing of surface to required level & slopespreading and moisting 30 mm thick local sand on bend filling joints with local sand for proper completion of work as per drawing and Technical specification |
| 77 | Mild Steel or iron work in heavy sizes such as trusses,built up gates,door frames record racks roof work,gates etc. wrought to required form including drilling holes rivetting or welding where necessary and also including supply of steel bolts nuts etc & their required for proper completion of the work. pwd 503 |
| 78 | Providing & fixing white vitreous china pedastal type water closet (European type) with seat and lid, 10litre white low level PVC flushing cistren including flush pipe with mannualy controlled device(Handle lever)conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.W.C. pan with ISI marked white solid plastic seat and lid. |
| 79 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 80 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Flat back wash basin size 630x 450 mm with a single 15 mm C.P. brass pillar tap. |
| 81 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 32 mm dia (for wash basin) |
| 82 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 40 mm dia(for sink and urinal) |
| 83 | Providing & Fixing 600 x 450 mm bevelled edge mirror of superiorglass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 84 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 85 | Providing and fixing of 15 mm nominal dia CP brass/Health Fuccet of standard design and approved make including flexible tube upto 1.0 m long etc complete. |
| 86 | Providing and fixing of Two way 15 mm nominal bore CP brass bib cock of standard design and approved make etc complete. |
| 87 | Providing & fixing white vitreous china flat back halfstallUrinalof 580x380x350 mm with white PVC automatic flushing cistern with fittings standard size CP brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in CP brass including painting of fittings and brackets cutting & making good the walls & floors wherever required. Range of two half stall urinals with 5 liter P.V.C. automatic flushing cistern. |
| 88 | Providing & fixing white vitreous china flat back halfstallUrinalof 580x380x350 mm with white PVC automatic flushing cistern with fittings standard size CP brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in CP brass including painting of fittings and brackets cutting & making good the walls & floors wherever required. Range of three half stall urinals with 10 liter PVC automatic flushing cistern. |
| 89 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade |
| 90 | Providing & fixingsalem stainless steel AISI 304(18/8) kitchen sink without drain board asper IS : 13983 with C. I. brackets and stainless steelplug 40 mm including painting of fitting and brackets cutting and making good the walls wherever required. 610 x 510 bowl depth 200 mm |
| 91 | Providing & fixing PVC pipes conforming to IS make working pressure 6 Kg/sqcm including testing labour T&P and all complete fitting. (RWP) 110mm dia |
| 92 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls, floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow, bend, tee and y-tee including supply of al marerial labour and T&P required for proper completion of work.90mm dia |
| 93 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls, floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow, bend, tee and y-tee including supply of al marerial labour and T&P required for proper completion of work. 110mm dia |
| 94 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100/75 mm, 110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
| 95 | Supply and fixing of UPVC S.W.R. door bend confirming to IS : 14735. 110 mm dia |
| 96 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS : 14735. 90 mm dia |
| 97 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS : 14735. 110 mm dia |
| 98 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS : 14735. 90x90x90 mm |
| 99 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS : 14735. 110x110x110 mm |
| 100 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS : 14735. 110 mm dia |
| 101 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS : 14735. 90 mmdia |
| 102 | Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chase and making good the wall etc. 15mm nominal outer dia pipes |
| 103 | Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chase and making good the wall etc.20mm nominal outer dia pipes |
| 104 | Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chase and making good the wall etc. 25mm nominal outer dia pipes |
| 105 | Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.Internal work exposed on wall 15mm nominal outer dia pipes |
| 106 | Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.Internal work exposed on wall 20mm nominal outer dia pipes |
| 107 | Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.Internal work exposed on wall 25mm nominal outer dia pipes |
| 108 | Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.Internal work exposed on wall 32mm nominal outer dia pipes |
| 109 | Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.Internal work exposed on wall 40mm nominal outer dia pipes |
| 110 | Providing and fixing ball valve (brass) of approved quality complete. (High or low pressure with plastic floats). 25 mm nominal bore |
| 111 | Providing& fixing 15 mm nominal bore 45 cm long unplasticised PVC connection pipe with brass unions. |
| 112 | Providing & fixing 15 mm nominal bore CP brass bib cock of approved quality conformingtoIS 8931. |
| 113 | Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standards and weighing not lessthan 810 gms. |
| 114 | Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931. |
| 115 | Providing, fixing G.I. pipes complete with all required G.I. fittings including trenching and refilling etc. (external work) 50 mm. dia nominal bore |
| 116 | Providing & fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 50 mm nominal bore |
| 117 | Constructing brick masonry chamber 600 x 600x 750 mm inside with F.P.S. brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20 mm nominal size); necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement : 3 coarsesand ) 12mmthick finished with a floating coat of neat cementcomplete as per standarddesign |
| 118 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls, floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow, bend, tee and y-tee including supply of al marerial labour and T&P required for proper completion of work. 110 mm. dia. Pipes |
| 119 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls, floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow, bend, tee and y-tee including supply of al marerial labour and T&P required for proper completion of work. 160mm. dia. Pipes |
| 120 | Hanching of SWR pipe with PCC 1:2:4 ( 1 cement: 2 coarse sand: 4 stone grit) of cross section alround pipe concrete 110 mm. dia. Pipes |
| 121 | Hanching of SWR pipe with PCC 1:2:4 ( 1 cement: 2 coarse sand: 4 stone grit) of cross section alround pipe concrete 160 mm. dia. Pipes |
| 122 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Inside size 90 x 80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 123 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5Inside size 120 x 90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : |
| 124 | Extra for depth formanhole with F.P.S. bricks size 90 X 80 cm |
| 125 | Extra for depth formanhole with F.P.S. bricks size 1.2m X 90 cm |
| 126 | Providing M.S. foot rests including fixinginmanholes with 20*20*10 cm cementconcreteblocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as perstandard design : with 20 x 20 mm square bar |
| 127 | Providing and fixing square mouth S.W. Gully trapgrade `A\" complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 180 x 150 mm. size P type |
| 128 | Providing & fixing viterous china toilet paper holder. |
| 129 | Providing and fixing PTMT Liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms |
| 130 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 75 mm dia pipe |
| 131 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia pipe |
| 132 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed withstiffmixture of cement mortar in the proportion of 1:2 (1cement : 2 finesand) includingtestingof joints etc. complete. 300 mm.dia. RCCPipes (AT ENTRANCE OF MAIN GATE) |
| 133 | Constructing brick masonaryroadgully chamber 50 x 45 x 60cm with F.P.S. brick in cement mortar 1 : 4 (1 cement : 4 coarse sand) including 500 x 450 mm precastRCChorizontal grating withframecompleteas per standard design.(AT ENTRANCE OF MAIN GATE) |
| 134 | Wiring point for light with 1 sq.mm FR P.V.C. insulated multistrand single core Copper Conductor cable in P.V.C. conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting complete with 1.5 sq mm FR P.V.C. insulated multistrand single core Copper Conductor cable as earth wire drawn inside & piano type switch and ceiling rose/angle/batten holder on 3 mm thick phinolic laminated backelite sheet etccomplete in all respects as directed including matching colour wash. |
| 135 | Wiring point for fan/fresh air fn (Light duty exhaust fan) with 1 sq.mm FR P.V.C. insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting complete with 1.5 sq mm FR P.V.C. insulated multistrand single core Copper Conductor cable as earth wire, piano type switch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheetetc. complete in all respect as directed including maching colour wash. |
| 136 | Wiring point for plug with 1 sq.mm FR P.V.C. insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting complete with 1.5 sq mm FR P.V.C. insulated multistrand single core Copper Conductor cable as earth wire, piano type switch & socket on 3 mm thick phenolic laminated backelite sheetetc. complete in all respect as directed including maching colour wash. |
| 137 | Wiring point for call bell with 1 sq.mm FR P.V.C. insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting complete with 1.5 sq mm FR P.V.C. insulated multistrand single core Copper Conductor cable as earth wire with piano type bell pushor 2 pin socket on 3 mm thick phenolic laminated backelite sheetetc. complete in all respect as directed including maching colour wash. |
| 138 | Wiring point for HPMV/sodium vapour lamp with 1.5 sqmm FR PVC insulated multistrand single core copper conductor cable in PVC conduit partially concealed in wall & partly laid in slab along with the reinforcement before concreting complete with 1.5 sq mm FR P.V.C. insulated multistrand single core Copper Conductor cable as earth wire and 15-A piano type switches etc. complete in all respect as directed including maching colour wash. |
| 139 | Add for light / fan points with modular type switches in place of piano type switches |
| 140 | Add for plug point with modular switch & socket in place of piano type switch & socket |
| 141 | Add for call bell point with modular type bell push in place of piano type bell push |
| 142 | Add for HPMV/Exhaust fan point with modular type switch in place of piano type switch. |
| 143 | Supply & fixing of power plug with 20A/250 volts flush type modular switch and 5 pin 20 A/250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of the work |
| 144 | S/F of sheet steel enclosure surface / flush mounting fitted with 20 amp 2 pin and earth metal clad scraping earth plug and socket complete. (for AC etc) |
| 145 | Supply & fixingof 20 amp. SP MCB (10 KA) (for AC etc) |
| 146 | Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge rigid steel coduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, including matching colour wash etc complete in all respects. 4 x 16 sq. mm. with 2 no 10 SWG copper earth continuity wire, in 40 mm dia conduit. |
| 147 | Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge P.V.C. coduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. 2 x 2.5 sq. mm. with 1 x 1.5 sq.mm. earth wirein 20 mm dia conduit. |
| 148 | 2 x 4 sq. mm. with 1 x 2.5 sq.mm. earth wire in 20 mm dia conduit. |
| 149 | 2 x 6 sq. mm. with 1 x 4 sq.mm. earth wire in 25 mm dia conduit. |
| 150 | 4 x 6 sq. mm. with 2 x 4 sq.mm. earth wire in 32 mm dia conduit. |
| 151 | 4 x 10 sq. mm. with 2 x 6 sq.mm. earth wirein 32 mm dia conduit. |
| 152 | Supply and fixing and concealing of PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and T&P etc. required for proper completion of the work as per directions and to the satisfaction of Engineer in charge. (for Telephone / Television / circuits) 20 mm dia. conduit (2 mm thick) |
| 153 | 25 mm dia. conduit (2 mm thick) |
| 154 | 32 mm dia. conduit |
| 155 | S/F of surface/flush mounting TPN distribution board with additional metal door and without MCBcompletein all respect as directed at site by Engineer-in-charge. (Cat-A) 6 WAYS |
| 156 | S/F of surface/flush mounting TPN distribution board with additional metal door and without MCBcompletein all respect as directed at site by Engineer-in-charge. (Cat-A) 8 WAYS |
| 157 | Supply & fixingof Single Pole MCB Blanking plate Cat-A |
| 158 | Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) Cat-A |
| 159 | S/F of 25 amp FP MCB(10 KA) Cat-A |
| 160 | S/F of 40 amp FP MCB (10 K.A.)Cat-A |
| 161 | S/F of 63 amp FP MCB (10 K.A.) |
| 162 | Supply Fixing and making commection of 30 MA E.L.C.B. (Earth leakage circuit breaker) of din/R.C.C.B. rail mounting complete in all respects as per directionandsatisfaction of engineer-in-charge. 25 Amp 4 Pole |
| 163 | Supply Fixing and making commection of 30 MA E.L.C.B. (Earth leakage circuit breaker) of din/R.C.C.B. rail mounting complete in all respects as per directionandsatisfaction of engineer-in-charge. 40 Amp 4 Pole |
| 164 | Supply Fixing and making commection of 30 MA E.L.C.B. (Earth leakage circuit breaker) of din/R.C.C.B. rail mounting complete in all respects as per directionandsatisfaction of engineer-in-charge. 63 Amp 4 Pole |
| 165 | Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with itstop at least 3 meters below ground level complete with 20 mm G.I. pipefor watering funnel, 30 cm square C.I. frame with hinged cover, masonry housing, alternate layersof coke/charcoal and salt at least 150 mm thick alroundetc. complete in all respects. |
| 166 | Supplying & Layingof 25mm x 3mm. G.I. strip for earthing purpose as required complete in all respects. |
| 167 | Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc. 10 sqmm 4core |
| 168 | same as item above but for 16 sqmm 4core |
| 169 | same as item above but for 1 185 sqmm 3 1/2core |
| 170 | Supply and fixing brass nickle plated compression glands for PVC insulated armoured, served, sheathed cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connectedwith the earth conductor. 10 sqmm 4core |
| 171 | same as item above but for16 sqmm 4core |
| 172 | same as item above but for185 sqmm 3 1/2core |
| 173 | Supply & fixing of plam or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections etc. complete in all respects as per direction of Engineer-in-charge. 10 sq.mm. |
| 174 | same as item above but for 1 16 sq.mm. |
| 175 | same as item above but for 1 95 sq.mm. |
| 176 | same as item above but for 1 185 sq.mm. |
| 177 | S/F of recess/surface/pendent mounted 10 to 15 watt LED down lighter having powder coated die cast aluminium housing with heat sink, difuser / refelector and driver set complete in all respectCategory AAA |
| 178 | S/F of 55 watt indoor recess mounting LED square fitting for Armstron ceiling having powder coated die cast aluminium housing body with extended heat sink, difuser of polycarbonate material and driver set complete in all respect. Category AA |
| 179 | S/F of LED Tube Light with batten suitable for up to 1x22 watt LED tube light fitting including tube on surface complete in all respect.Category AAA |
| 180 | S/F of LED Tube Light with batten suitable for up to 2x22 watt LED tube light fitting including tube on surface complete in all respect.Category AAA |
| 181 | S/F of single LED light wall bracket 3 to 6 Watt on matching M.D.F.E.G. Board base etc complete in all respect. Category AAA |
| 182 | S/F ofLED street light fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 watt confirming to IP 66 protection complete in all respect. Category AAA |
| 183 | Supply of ceiling fan with fan motor of AC permanent insulation, capacitor rating conforming BEE 5 star rating and IS : 374/79 and also comply with IS:1709/1984 with latest amendment the rated voltage 220/240 volts, 50 HZ single phase AC, the fan assembled should consists of down rod, blades, shackel canopies etc and with double ball bearing system. BEE 5 star rating - 1200 mm sweep |
| 184 | Erection and testing of ceiling fan and regulator for room height upto 3.50 meter including supply of 3 mm thick G.I. Rod 19 mm dia. Duly painted, complete in all respect. |
| 185 | Add extra to above item for 15 cm or part thereof for room height from 3.50 to 5.00 meter. |
| 186 | Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. |
| 187 | Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. |
| 188 | S/F of hexagonal fan box with hexagonal side of approx. 80 mm.in lengthfabricatedfrom 16 SWG M.S. sheet incorporating with10 mm. dia. M.S. round bar duly bent for supporting fan hanger duly painted with redoxideand screwingarrangementwithwiringconduit laid in the R.C.C.roofbeforeconcreting along with supply of all materials,labour, T&P etc. for proper completion of work. |
| 189 | Supply & fixing ofelectronic Fanreulator, 120-280 V, ISI marked, on the existing switch board including making connections, required material,labour T/P etc. for proper completion of work to the satisfaction of Engineer of work. |
| 190 | S/F of doorchimeonPolishedM.D.F.E.G. board includingmakingconnectionsetc. complete in all respects. |
| 191 | S/F of danger board fabricated from 10 gauge M.S. sheet as per E/I rules. |
| 192 | S/Fof shocktreatmentchart ( prescribed under I.E.rules ) duly framed with glass and supported from back with hard board orsoft board with supply of all material labour T & P etc for proper completion of work. |
| 193 | Supply andlayingof 1800 mm x 900 mm x 12 mm thick chequered rubber mattingof tested quality. |
| 194 | Supply & Errecetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB\"s (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F, KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB\"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. Incomer : 400 Amp MCCB-1 No Outgoings :200 Amp MCCB, 100 Amp MCCB, 63 Amp MCCB or as required Cat-B Panel Cubical Type |
| 195 | Supplying and fixing following size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75 mmX75 mm) |
| 196 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module (75 mmX75 mm) |
| 197 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet |
| 198 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet |
| 199 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 pair |
| 200 | Supplying and drawing Co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 201 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 202 | Providing, fixing, connecting & testingof Krone box (Telephone Tag Block) in athermoplastic, IP 65 (weather proof) enclosure, internally embedded gasket, anti corrosive, insulated and shock proof with provision for cable through IP 65 glands complete in all respects. (Make : Hensel) 10 pair krone (Hensel - KG 9001 - size 136*253*115 mm) |
| 203 | Providing, laying, connecting, testing& commissioning of multi-core telephone armoured cables of conductor size 0.5 sq.mm. annealed tinned electrolitic grade copper, PVC insulated, twisted pairs bunched together, over all PVC sheathed, GI strip or wire armouring laid on existing cable tray or along the wall or laidin pipes or in trenches including excavationofcabletrench, sand filling covering with bricks andback filling complete as required. 10 pair |
| 204 | Providing & Fixing of modular plate type white RJ 45 Data outlet / information outlets ETL verified to meet or exceed TIA / EIA category 5e requirements, universal wiring label permitting to either T568A or T568B, UL listed,for computer networkingcomplete in all respect with cover plate, grid plate, screws, MS box, etc with connections as required.1 nos. RJ 45 Data Outlet |
| 205 | Providing, drawing, connecting and testing of enhanced category 4 pair LAN (local area network) cable, UL and CUL listed, in existing MS/PVC conduit or floor raceways including connections etc as required complete in all respects. (Make : AMP / Systemax) CAT-5 network cable |
| 206 | Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Crompton / Havells)300 mm sweep 900 rpm |
| 207 | Supply of AC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete (Make : Bajaj / Usha / newtek / Havells)300 mm sweep |
| 208 | Supply of 400 mmsweepAC 230/250 volts, 50 HZ wall mounting revolving fan with brackets etc. complete (Make : Bajaj / crompton / havells) |
| 209 | Supply, Installation, testing & commissioning of totally enclosed, floor mounting, metal clad, Indoor type, horizontal drawout type HT Panelhigh voltage board with 24 Volts DC closing and tripping coils and 230 Volts AC spring charging motor with battery bakup and charger unit for installation. |
| 210 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/ IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50 mm Dia |
| 211 | same as item above but for80 mm Dia |
| 212 | same as item above but for 100 mm Dia |
| 213 | same as item above but for 150 mm Dia |
| 214 | Providing laying, testing & commissioning of \"C\" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 NB |
| 215 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal /Stainless Steel cap and chain as required :( Single headed Gun Metal |
| 216 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 150 mm Dia |
| 217 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :(DSR E&M-2022) 50 mm Dia |
| 218 | same as item above but for80 mm Dia |
| 219 | same as item above but for 100 mm Dia |
| 220 | same as item above but for 150 mm Dia |
| 221 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80 mm Dia |
| 222 | same as item above but for150 mm Dia |
| 223 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 Meter |
| 224 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required:Gun Metal |
| 225 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal |
| 226 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :3 way-150 mm dia M.S. Pipe |
| 227 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm Dia |
| 228 | same as item above but for150 mm Dia |
| 229 | Providing & fixing air release made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height, with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metalwheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. (DSR E&M-2022) |
| 230 | Providing & fixing pressure switch in MS pipe line including connection etc as required. (DSR E&M-2022) |
| 231 | Constructing brick masonry chamber 900 x 900 x 1000 mm inside with F.P.S. brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20mm nominal size);necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cementcomplete as per standard design (DSR Civil-2021) |
| 232 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fitting andbase support for tank. (Rs 9.70/Lt) ( 2500 litres capacity |
| 233 | Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered with anti vibration pads.Discharge : 2280 lpm,Head : 56 meter |
| 234 | Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, completein all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.Discharge : 2280 lpm,Head : 56 meter |
| 235 | Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS : 325.M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. Discharge : 180 lpm,Head : 56 meter |
| 236 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-\"F\" insulation, conforming to IS-325.M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.Discharge : 450 lpm,Head : 35 meter |
| 237 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : Incomer : 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-400A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Bus Bar : Set of copper bus bar 500 AMP .Outgoings : Outgoings : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lampsMain Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fullyJockey Pumpautomatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation-2sets 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local / remote, auto / manual / OFF operation.- 2 sets Diesel Engine Control Control of diesel engine comprising - Automatic/manual selector switch and 3 attempts starting device timer and relays as required, push buttons, start/stop in manual mode indicating lamp for high/low lub. Oil pressure, high water temp and engine on indication. Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC Voltmeter and 0-20 A DC ammeter all standard relays and accessories for automatic operation of diesel engine.System Controller Designing, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays timers, sensors, annunciations window for fault indication, complete as per specification. |
| 238 | Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc.95 sqmm 3 1/2core |
| 239 | Supply and fixing brass nickle plated compression glands for PVC insulated armoured, served, sheathed cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connectedwith the earth conductor. 95 sqmm 3 1/2core |
| 240 | Supply & fixing of plam or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections etc. complete in all respects as per direction of Engineer-in-charge. 50 sq.mm. |
| 241 | same as item above but for 95 sq.mm. |
| 242 | S/Fof shocktreatmentchart ( prescribed under I.E.rules ) duly framed with glass and supported from back with hard board orsoft board with supply of all material labour T & P etc for proper completion of work. |
| 243 | Supply andlayingof 1800 mm x 900 mm x 12 mm thick chequered rubber mattingof tested quality. |
| 244 | Supply & erection of ISI marked portable fire extinguishers, wall mounted type, wall brackets complete in all respect as per standard item with all accessories, delivery hose & nozzle whereever required, including fixing on walls as per the directions ofEngineer-in-charge.ABC Powder type 6 kg. capacity (IS:15683 & TAC Approved) |
| 245 | CO2 gas type. 4.5 kg. Capacity (IS:2878 & TAC Approved) |
| 246 | Providing & fixing standard carbon steel fireman axe with rubber insulated handle tested to 20000 Volts. |
| 247 | Providing and fixing standard fire hose cabinet door frame (1000 / 1200 mm x 2000 mm ) suitable to fit in the duct made of not less than 16 SWG MS sheethaving full fronted glass hinged door (5 mm thick clear glass) including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall or as required. The words \"FIRE HOSE\" to be painted on the box. |
| 248 | Providing and fixing in position M.S. pipe sleeves (heavy class) of upto 300 mm longwith M.S. puddle flange in RCC beams / retaining wall and other structural members during the time of casting the same including hot dipped galvanization after fabrication and painting with two coats of anti corrosive paint over primer. (for the crossing of sprinkler pipes)65NB |
| 249 | same as item above but for 100NB |
| 250 | same as item above but for150NB |
| 251 | Providing and fixing in position M.S. pipe flanged sleeves of 600 mm long (heavy class) with M.S. puddle flange fabricated out of 6 mm thick MS plate in RCC walls of water tanks / retaining walls during the time of casting the same including hot dipped galvanization after fabrication and painting with two coats of anti corrosive paint over primer.65NB |
| 252 | same as item above but for 100 NB |
| 253 | same as item above but for 150 NB |
| 254 | Supply, installation, testing and commissioning of intelligent analog adderessble photo thermal detector complete withmounting base complete as required. |
| 255 | Supply, installation, testing and commissioning ofintelligent adderessble thermal detector with rate of rise cum fixed temprature thermistor complete with base as required. |
| 256 | Supply, installation, testing and commissioning of Adderessable Manual call pointcomplete as required. (DSR E&M-2022) |
| 257 | Supply, installation, testing and commissioning of addressable horn cum strobe complete as required. (DSR E&M-2022) |
| 258 | Supply, installation, testing and commissioning of response indicators on surface/recessed MS box having two LED metallic cover complewith all connectionsetc as required. (DSR E&M-2022) |
| 259 | providing, installing, connecting, testing and commissioning of microprocessor based intelligent addressable Main Fire Alarm panel central processing unit with the following loop modules and capable of supporting not less than 240 device (including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphic / LCD display with touch screen or other key pad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit(230 +/- 5% V, 50 Htz) 48 hrs backup with 24 volt sealedmaintenance fre bateries with automatic charger. The Panel shall have facility to connect printer to print out log and and facility to have seamless integration with analog/digital voice evacuation system (and shall be be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BAC net/Modbus over IP complete as per specifications.(DSR E&M-2022) 10 loop panel |
| 260 | Supply and fixing of following size medium class PVC conduit along with accessories in surface / reccess including cutting the wall and making good the same in case of reccessed conduit as required.( 25 mm |
| 261 | Supplying, and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / reccessed, steel / PVC conduit as required.( 2 x 1.5 Sqmm |
| 262 | Supply, installation, testing and commissioning of Talk back slave station in surface/recess suitable for operation om simplex mode complete with PTT knob and speaker / microphone enclosed in a MS (16 SWG) / ABS box with break glass in front etccomplete as required. (DSR E&M-2022) |
| 263 | Providing and fixing of self illuminated / auto glow \"EXIT\" signs printed on photoluminescentsheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site. |
| 264 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.10 sqmm 4.0core |
| 265 | same as item above but for 25 sqmm 3.5 core |
| 266 | same as item above but for 120 sqmm 3.5 core |
| 267 | Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metresbelow ground level complete with 20mm dia G.I. pipeand funnel for watering and one earthing lead of two no.8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respect. |
| 268 | Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects. |
| 269 | Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects. |
| 270 | Supply and erection of steel tubular pole 9.0 meters long designated 410 SP-29 in 1:3:6 cement concrete foundation including excavation, back filling etc. complete in all respects. |
| 271 | Supply and Fixing ofservice bracket of 50mm. Dia 4 meter long fabricated from class \"\"B\"\" G.I. pipe complete with two bend, socket, wall clamps. 7/3.15 mm G.I. stay wire, stay insulators etc..complete in all respects. |
| 272 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66protection complete in all respect. CAT- AAA |
| 273 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN complete in all respect. 25A SPN |
| 274 | Transportation of mini drilling Rig machine with camp equipage to site. |
| 275 | Drilling of 350mm dia bore hole with lowering of tubewell assembly. DSR - 23.2.1.2 |
| 276 | Supply and fixing of 200mm dia plain rigid PVC casingpipe (10 Kg./sqcm pressure rating) and accessories. DSR - 23.3.3 |
| 277 | Supply and fixing of 150mm dia plain rigid PVC slottedpipeand accessories. DSR - 23.3.2 |
| 278 | Supply and fixing of nylon jali around the slotted pipes complete as required. |
| 279 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin-charge DSR 23.8 |
| 280 | Supply of submersible pump of make KSB 5.0 HP with control panel, support wire etc. complete. |
| 281 | Providing 3 core 2.5 sqmm PVC insulated copper conductor submersible cable.(from pump panel to submersible pump) |
| 282 | Providing and fixing 65mm dia G.I. Pipe complete with fitting and clamps including cutting and making good the wall etc. (from submersible pump to ground level) DSR -18.12.7 |
| 283 | Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality. D.S.R.-18.17.5 |
| 284 | Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect. |
| 285 | Fixing, testing and commissioning for erection and lowering of submersible pump, 65mm dia GI column pipe, 3 core 2.5 sqmm submersible copper cable upto the control panel, supporting clamps, cable clips pressure gauge, connection line and all other accessories required for the proper completion of the work. |
| 286 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.DSR -23.12 |
AI Tender Summary
Tender Timeline
Dec 27, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedJan 16, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 16, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender