Tender For Annual Repairs And Maintenance Of Electrical Installations At Bsc Hanuman Junction For The Year 2023-24, Krishna-Andhra Pradesh

Food Corporation Of India-FCI has published Tender For Annual Repairs And Maintenance Of Electrical Installations At Bsc Hanuman Junction For The Year 2023-24. Submission Date for this Tender is 09-01-2024. Electrical Maintenance Tenders in Krishna Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41317993
Tender For Annual Repairs And Maintenance Of Electrical Installations At Bsc Hanuman Junction For The Year 2023-24
Open Tender
Indian
Andhra Pradesh
Krishna
09-01-2024

Tender Details

Annual Repairs And Maintenance Of Electrical Installations At Bsc Hanuman Junction For The Year 2023-24. S.H Rewiring To Godown NoS 5 & 6 And Improvement Of External Lighting With New Energy Efficient Led Street Light Fittings At Depot Complex By Providing Ug Cable To The Existing Poles And Other Allied Works.

Key Value

Document Fees
Refer document
EMD
INR 32120.0 /-
Tender Value
INR 16.05 Lakhs /-

BOQ Items

Name of Work: Annual Repairs and Maintenance of electrical installations at BSC Hanuman Junction for the year 2023-24. S.H Rewiring to Godown No"s 5 & 6 and improvement of external lighting with new energy efficient LED street light fittings at depot complex by providing UG cable to the existing poles and other allied works.
Sl. No. Item Description
1Supplying of PVC/XLPE armoured cable with aluminium conductor 1.1 KV Gradeconfirming to IS 7098 (part I)1988 with upto date amendments of the following size at the site of work.
23 X 10 Sq.mm
3Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
4upto 35 Sq.mm
5Laying and fixing of one number PVC insulated and PVC sheathed/XLPE Power cable of following size on wall surface as required
6Upto 35 sq.mm (Clamped with 1mm thick saddle)
7Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
8Upto 35 sq. mm
9Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
10Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
11100 mm dia
12Supplying and fixing of following size of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
1320 mm
14Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required.
153 X 1.5 Sq mm
166 X 1.5 Sq mm
179 X 1.5 Sq mm
18Supplying and fixing 20 A, 240V, SPN Industrial type socket outlet with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc, as required.
19Supply, installation, Testing and commissioning of 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy min of 100 lumens/W along with Surface/Suspended waterproof industrial luminaire(IP 66) with polycarbonate housing and diffuser suitable for single 4 ft T8 tube etc.at the site of work.(ISI certified)
20Supplying, installation, testing andcommissioningof 20W LED T8 tubelight with PC body in the existing LED box type luminaire etc. at site of work as required.(NABL certified as per ISO/IEC specification)
21Supplying, installation, Testing and commissioning of 70 watt LED type Well Glass Light in pressure die-cast aluminium housing and fixing on truss /wall/pole with suitable clamps and nut bolts(ISI certified ) .. (RatingIP66,Luminare efficacy>120Lm/W,CRI>75, ).
22Supplying, installation, Testing and commissioning of 40 watt LED type Well Glass Light in pressure die-cast aluminium housing and fixing on truss /wall/ pole with suitable clamps and nut bolts(NABL certified as per ISO/IEC specification) .. (RatingIP66,Luminare efficacy>120Lm/W,CRI>75, ).
23Supplying, installation, Testing and commissioning of70W LED Street light fitting made up of pressure die cast alluminium housing and fixing on wall/truss/pole with suitable clamps and nut bolts including giving connection etc., at site of work as required.(ISI certified)
24Removing, Checking, installation and refixing of Phillips make 36W,0.16 A,240 V Xitanium Driver in the existing 40 W LED Well glass light fitting including giving connection etc. at site of work as required. .
25Supplying, installation, testing andcommissioningof 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current(BLDC) motor, class of insulation: B, 3 no.s blades, 30 cm long down rod, 2 no.s canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, Service value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit forspeed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230v, 50Hz, single phase AC supply, earthing etc. complete as required.
26Supplying and fixing of Hot pressed moulded SMC Junction box of size 230mm x 170mm x 105mm with 6A SP MCB, 2/4 way strip connector etc. as required at the site of work.
27Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
283 X 10 sq. mm (22mm)
29Supplying and drawing of 1.5 Sq.mm,three core PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 in the existing surface/ recessed steel/ PVC conduit as required.
30Providing and Making steel pole colar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required.(volume of pole/pipe not to be deducted)
31Supplying of 7m high hot dip galvanized octagonal street light pole with 70 mm top dia, 130 mm bottom dia, 3mm thick and with a base plate of 200 mm x200 mm x 12 mm complete with 1 mtr hot dip galvanized single Arm bracket for fixing the street light and suitable foundation bolts etc. as required at the site of work.
32Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
33Above 6.5 metre and upto 8.0 metre
34Supplying and fixing of 32 mm dia X 2.00 metres long G.I pipe (medium class ) bracket for mounting of flurescent/ HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40mm X 3mm flat iron clamps with nuts, bolts and washer, Painter the flat iron with primer and finish paint etc. as required.
35Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
36One or more coats on old work
37Painting the MS/GI/Rail pole and all accesories including cleaning by rubbing with sand paper , removing dust with cotton, painting with one coat of primer and one or more coats of aluminium enamel paint and providing zebra lining (y/b) up to 1.5 mtr from ground level with proper numbering, etc. as required.
38Dismantling of existing damaged Polesand shifting to depot stores etc., as required.
39CREDIT ITEMS
40Dismantled MS Conduit Pipes of different sizes, DB"s, GI Wire etc
41Dismantled 40w box type tube light fitting
42Dismantled aluminium inulated wire