Military Engineer Services-MES has published Tender For Repair And Maintenance Of Ceiling Fans, Air Circulator, Exhaust, Geysers And Allied Works Services For Otm Accommodation At Jaipur Mil Stn Under Ge (S) Jaipur. Submission Date for this Tender is 22-01-2024. Air Circulators Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

41310308
Corrigendum : Tender For Repair And Maintenance Of Ceiling Fans, Air Circulator, Exhaust, Geysers And Allied Works Services For Otm Accommodation At Jaipur Mil Stn Under Ge (S) Jaipur
Open Tender
Indian
Rajasthan
jaipur
22-01-2024

Tender Details

Tender For Repair And Maintenance Of Ceiling Fans, Air Circulator, Exhaust, Geysers And Allied Works Services For Otm Accommodation At Jaipur Mil Stn Under Ge ( S ) Jaipur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work:REPAIR AND MAINT OF CEILING FANS, AIR CIRCULATOR, EXHAUST, GEYSERS AND ALLIED WORKS SERVICES FOR OTM ACCN AT JAIPUR MIL STN UNDER GE (S) JAIPUR
Sl. No. Item Description
1Taking down carefully existing storage type Geyser 25/50 litres capacity for repair complete overhauling including cleaning of geyser assembly inlet outlet pipe etc and re-fixing in position complete all as specified and as directed.
2Cleaning and preparation of outer surface of Geysers 25/50 litres capacity and painting with two coats of white synthetic enamel paint complete all as specified and as directed.
3M&L for opening of geyser 20/50 litrescapacity in position for carry out minor repair such as loose connection testing of thermostat, heating element, tightening of screws, PVC connection, bottom assembly pressure release valve, indicator etc. complete all as specified and as directed. Note :- Any major item required in measured and replacement shall be paidseparately as supply only.
4Supply only Stainless steel inner tank of capacity 25 Ltr.
5Supply only Stainless steel tank of capacity 50 Ltr.
6Supply only Glass wool/ rock wool for thermal insulation.
7Supply only Outer tank madeof MS sheet powder coated suitable for 50 Ltrs.
8Suppy only Outer tank made of MS Sheet powder coated suitable for 25 Ltrs.
9M&L dismantling of bottom assemble and de-scaling with acid and wire mess brush cleaning and refixing the same.
10Suppy only PVC insulated and over all PVC sheathed copper conductorwire of size 2.5 Sqmm x 3 core, Lead wire with ISI marked.
11Supply only Plug top 3 pin, 15 Amp rating ISI marked.
12Supply only replacement of heating element of capacity 1.5 KW ISI marked.
13Supply only heating element of capacity 2 KW ISI marked.
14Supply only heating element of capacity 1.5 KW having 115mm dia base with 6 hole with diaphram washer suitable for geyser 25 litre capacity.
15Supply only heating element Clip on made of copper, capacity 2 KW ISI marked.
16Supply only Geyser bottom assemblyof 7 hole/9 Hole/6 hole as per existing complete including, bolts and rubber gasket for 25/50 litres capacity Geysers as per requirement with the same make which is to be replaced.
17Supply only Pressure release safety valve for Geysers spring loaded suitable for 15mm pipe chromium plated.
18Supply only thermostat ISI marked of any make/ capacity of geyser.
19Supply only thermostat ISI marked suitable for geyser venus T105 type TBS 16 A 250 Volt
20Supply only thermostat ISI marked suitable for geyser make Bajaj with 2 male terminals and round base.
21Supply only neon indicator lamp round or rectangular type.
22Supply only PVC flexible connection hot and cold, high strength, impeccable finish, corrosion resistance 450mm long for geyser
23Supply only PVC flexible connectionhot and cold, high strength, impeccable finish, corrosion resistance 600mm long for geyser
24S&F repair GI tubes 15mm bore medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floors, complete all as specified and as directed.
25S&F in repair 15 mm bore Angle stop valve of PTMT any colour high pressure screwed for iron pipe (Minimum weight 90gms), complete all as specified and as directed.
26S&F in repair 15 mm Bib taps , cast copper alloy with crutch of butter fly handle screwed down , screwed for iron pipe or for brass ferrule, fancy type and fixed complete all as specified and as directed.
27Disconnecting electrical connection andwater connection and dismantling/ taking outGeyser of any make and capacity from any placeandinstallation, commissioning and testing to another location including grounting nut and bolts with washers or with fasteners and testing complete all asspecified and as directed.
28M&L in repair Point wiring using approved colour coding as per IS, with stranded copper conductor2.5 Sq. mm (nominal area), single core, FRLS insulated, PVC insulated and unsheathed stranded cable 1100 volts grade, confirming to IS-694/ISI markedin and including PVC casing caping25mm, medium grade, ISI marked, with mild steel sunken boxes with earth dolly zink coatedand including mounting frame andover cover plate, including PVC insulated stranded copper conductor 2.5 Sqmm (nominal area) single core cable as earth continuity conductor to common earthand connected FRLS cable 1100 V grade as continuous earth wire to earth dollyfor 3 pin switch socket outlet15Amp independent board complete all as specified and as directed including taking out old with switch and sockets.
29S & F Switch Piano typetype 230/ 250V grade on top covers 16 Amp, complete all as specified and as directed.
30S & FSocket outlet multipurpose use, non/shuttering non/ interlocking flush mounting type, 230/250 Volts grade on top covers16 Amp, complete all as specified and as directed.
31Repair to solar water heater Descaling of solar collectors with acid (dilute)for solar water heater panel of 200 LPD as recommendedby manufacture cleaning and re-assembling complete and soldering for change, complete all as specified and as directed.
32Descaling of solar collectors with acid (dilute)for solar water heater panel of 100 LPD as recommendedby manufacture cleaning and re-assembling complete and soldering for change, complete all as specified and as directed.
33Taking down water inlet/outlet of solar collectors plate , disconnetion of mounting and dismantlling into parts and cutting inner copper tubes, removing the scaling from the chocked copper tube by drilling and scraping with hard metal rods including washing with acid(dilute) competer for solar panel 3 Nos suitable for 200 LPDhaving 6 Nos tubes in each panel, brazing with existig pipes after descaling complete including testing for leackage, if any and reassembling the same in the existing mountingas recommendedby manufacture cleaning and re-assembling complete and soldering for change, complete all as specified and as directed.
34Taking down water inlet/outlet of solar collectors plate , disconnetion of mounting and dismantlling into parts and cutting inner copper tubes, removing the scaling from the chocked copper tube by drilling and scraping with hard metal rods including washing with acid(dilute) competer for solar panel 1 Nos suitable for 100 LPDhaving 6 Nos tubes, brazing with existig pipes after descaling complete including testing for leackage, if any and reassembling the same in the existing mountingas recommendedby manufacture cleaning and re-assembling complete and soldering for change, complete all as specified and as directed.
35Supply and replace hose pipe for hot and cold water as per existing
36Taking out U/S gate valve and supply and fixingof gate valve 15mm dia ISI marked complete all as specified and as directed.
37Taking out U/S gate valve and supply and fixingof gate valve 20mm dia ISI marked complete all as specified and as directed.
38Supply and replace U/S electric back up element 240 volt AC supply 3KW rating ISI marked including thermostate all as per sample, complete all as specified and as directed.
39Supply and replace U/S electric back up element 240 volt AC supply 5 KW rating ISI marked including thermostate all as per sample, complete all as specified and as directed.
40Taking out old rusted GI pipe including supply and fixing GI pipe 20 mm bore ISI marked medium grade complete as specified and as directed.
41Repair to leakage for existing solor heater panel of 200 LPG complete all as specified and as directed.
42Supply & replace following unserviceable item from sheet metal enclosure complete 240 Volts, AC supply.
43Metallic Plug top.
44Metallic socket
45MCB 5 to 32 Amp, 10 KA,SP "C" Series
46S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 amp MCB 240V "C" series complete all as specified and as directed.
47S & F in replacement of rusted Angle iron of size 40x40x5 mm for supporting Solar panels on roof top including welding and fixing with suitable nut bolts and washer complete all as specified and as directed.
48M&L for PCC (1:2:4) type B-0 in cementconcrete for grouting angels in roof surface withusing 12.5 mm graded stone complete all as specified and as directed.
49Taking down carefully existing ceiling fans/wall fans of any make and sizes from ceiling/wall ,cleaning externally, opening for examination and overhauling complete by opening , cleaning of bearing ,stator ,rotor winding , providing new fresh clean proper grade lubricants oil/grease and reassembling after replacement of rubber real,wall fan blade , wall fan bracket ,MS nuts and bolts , split/safety pins and fan connector including replacement of old existing flexible cord connected from ceiling rose to fan through down rod and refixing and rehanging the same in existing position complete all as specified and as directed. Note: Rewinding shall be measured and paid separately under respective item.
50M &L for dismantling of worn out/burnt out ceiling fans 1200 mm sweep Fans/Wall fans 200/400 mm and re-winding the ceiling fan with the same size of super enamelled copper wire , varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut , complete all as specified and as directed.
51All all as per serial item No 47 here in before but for Ceiling fans of 1400 mm sweep. Note:- (a) Repairs under serial item No 46 here in before shall be carried out at the site of work. Where as fans for repair under serial item No 47 and 48 shall be issued to contractor and the same shall be returned by him after carrying out necessary repairs duly tested. (b) Rewinding under srl item No 47 & 48 shall be done with winding machine (c) Fans will be given to contractor for rewinding underGate Pass in Lots of appx 50 Fans and the same shall be returned by contracter in 10 Days time after all repairs and painting.And the panelity for not receipt of repair fan in stipulated time shall be Rs 20 per fan per day. (d) Spare parts like ball bearing, gun metal bush, capacitors and canopy required for repair/overhauling shall be measured and paid separately under relevant item of this schedule as supply only
52Supply only ball bearing suitable for ceiling fans of any make, type and size.
53Supply only bush made out of Gun metal suitable for ceiling fans of any make, type and size.
54Supply only capacitors 2.5 MFD suitable for ceiling fans of any make, type and size.
55Supply only canopy suitable for ceiling fans of any make, type and size.
56Supply only down rod suitable for ceiling fans of any type and any size as per Sample/approved by GEcomplete all as specified and as directed.
57Supply only clamp with nuts & bolts & locking pin suitable for ceiling fans of any make, type and size.
58Supply only replacement rubber reels suitable for ceiling fans of any make, type and size.
59Supply onlyfan regulator Piano type for ceiling fans of any make, type and size.
60Supply only Ceiling cover Plate circular type for ceiling fans of any make, type and size.
61Taking down carefully existing exhaust fans / PVC Air Freshner Fans of any make and sizes from wall , cleaning externally, opening for examination and overhauling complete by opening , cleaning of bearing ,stator ,rotor winding , providing new fresh clean proper grade lubricants oil/grease and re assembling after replacement of split/safety pins, MS nuts and bolts , including replacement of old existing flexible cord connected from ceiling rose to fan and , refixingthe same in position complete all as specified and as directed. Note:- Rewinding and spare parts like ball bearing, gun metal bush and capacitors required for repair/overhauling shall be measured and paid separately under relevant item of this schedule.
62M &L for dismantling of worn out/burnt out Exhaust fans/ / PVC Air Freshner Fans 200 mm to 300 mmsweep and re-winding the exhaust fan with the same size of super enamelled copper wire , varnishing with approved quality insulating varnish complete including replacement of split/safety pins, rusted nut, bolt and washer complete all as specified and as directed.
63M &L all as per serial item No 59 here in before but for Exhaust fans of size above 300 mm but up to 450 mm sweep, complete all as specified and as directed. Note: - (a) Repairs under serial item No 58 here in before shall be carried out at the site of work. Where as fans for repair under serial item No 59 and 60shall be issued to contractor and the same shall be returned by him after carrying out necessary repairs duly tested. (b) Exhaust fans will be given to contractor for rewinding underGate Pass in Lots of appx 50 Exhaust Fans and the same shall be returned by contracter in 10 Days time after all repairs and painting and the panalty for not receipt of repair fan in stipulated time shall be Rs 20 per fan per day. (c) Spare parts like ball bearing & capacitors etc required for repair/overhauling shall be measured and paid separately under relevant item of this schedule as supply only
64Supply only ball bearing suitable for exhaust fans of size from 200 mm to 300 mm sweep.
65Supply only capacitors 4.0 MFD for exhaust fans of size 300 mm to 450 mm sweep.
66Material and labour for preparation of old surfaces of Exhaust fan by scraping out old paint with the help of emery paper/ wire brush including filling the cavities and painting with two coats ofgrey paint for exhaust fansandexhaust fan louver over a coat of red oxide primer with the help of spray machine complete all as specified and as directed.
67S&F in replacement of louvers shutters complete with nuts, bolts and washers suitable for exhaust fans of size 250mm to 300 mm sweep complete all as specified and as directed.
68All as per serial item No 64 here in before but for exhaust fans above of size 300 mm to 450 mm sweep complete all as specified and as directed.
69S&F in replacement of worn out nuts and bolts for fixing of Exhaust fans including finishing the disturbed surface ofwall complete all as specified and as directed.
70Supply and fix in replacement for PVC insulated and over all PVC sheathed copper conductorwire of size 1.5 Sqmm x 3 core,flexible wireISI marked, for connection of fan from ceiling rose to fans complete all as specified and as directed.
71M &L for hanging clamps with provision of hook made out of MS flat of 20mm x 3mmlength 15 cmwith suitable size nut,bolt and washer complete all as specified and as directed.
72M &L for ceiling rose surface bakelite 65X50 mm, three terminal complete all as specified and as directed.