Tender For 325/24-Supply And Providing Gen Sets In Community Hall And Additional Crematorium At Kadungalloor, Ernakulam-Kerala

Grama Panchayat has published Tender For 325/24-Supply And Providing Gen Sets In Community Hall And Additional Crematorium At Kadungalloor. Submission Date for this Tender is 03-01-2024. Electrification Work Tenders in Ernakulam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

41299485
Tender For 325/24-Supply And Providing Gen Sets In Community Hall And Additional Crematorium At Kadungalloor
Open Tender
Indian
Kerala
Ernakulam
03-01-2024

Tender Details

325/24-Supply And Providing Gen Sets In Community Hall And Additional Crematorium At Kadungalloor , Electrical , 14.1:Excavation For Foundation In Soft Soil Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 Metres. , 14.3:Filling Available Excavated Earth (Excluding Rock) In Trenches, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 Metres. , 14.7:Providing And Laying In Position Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) In Foundation Of Pump, Dg Set Etc Including Form Work Etc As Required. , 14.12:Providing 15Mm Thick Cement Plaster Of Mix 1:4(1 Cement: 4 Fine Sand) At All Levels , Od209850/2023-2024:Supply Installation Testing And Commissioning And Trail Run Of 15Kva/12 Kwsilent Three Phase 440 V, 1500 Rpm , 0.8 Power Factor, 50 Hz Canopised Diesel Comprising Generation Unit Ofashok Leyland Model Al2cdg1diesel Engine Developing 21Bhp At 1500 Rpm Coupledwithleroy Somers/ Crompton15 Kva/12 Kw Alternator 415 Volts- 3 Phase, Complete With Standard Accessories Mounted On A Channel Iron Base Frame, Fuel Tank, Standardcontrol Paneland Battery Battery Leads With Battery Charger Etcincludingsupply And Fitting Ats/ Amf Panel Etc Complete As Required With Cpcb Approvedacoustic Enclosure Complete With Stdcontrol Panel, Sound Level-75 Db (A) At One Metre From Enclosure Surface In Free Field Condition As Per Iso 8528 And Maintain A Warranty Of 24 Months From The Date Of Commissioning Including 5 Years Engine Critical Parts Warranty Etc As As Required. , Od170316/2023-2024:Supply Installation Testing And Commissioning And Trail Run Of 100 Kva/ 80 Kwsilent Three Phase 440 V, 1500 Rpm , 0.8 Power Factor, 50 Hz Canopised Diesel Comprising Generation Unit Ofashok Leyland Model Al6dtidg1 Diesel Engine Developing 126.01 Bhp At 1500 Rpm Coupledwithleroy Somers/ Crompton100 Kva /80 Kw Alternator 415 Volts- 3 Phase, Complete With Standard Accessories Mounted On A Channel Iron Base Frame, Fuel Tank, Standardcontrol Paneland Battery Battery Leads With Battery Charger Etcincludingsupply And Fitting Amf Panel Etc Complete As Required With Cpcb Approvedacoustic Enclosure Complete With Stdcontrol Panel, Sound Level-75 Db (A) At One Metre From Enclosure Surface In Free Field Condition As Per Iso 8528 And Maintain A Warranty Of 24 Months From The Date Of Commissioning Including 5 Years Engine Critical Parts Warranty As Required. , Od193969/2023-2024: Supply, Conveying & Fixing 100 Mm Dia Medium Gi Pipe With Suitable Heavy Type Gi Specials Such As Bend, Reducer Etc As Silencer Extensionpipe Including Cutting In To Required Length,And Supply And Providing Ms Flanges Having 12 Mm Thickness As Required, Including Conveyance Charges And Paintingthe Pipe Etc , Od209887/2023-2024: Supply, Conveying & Fixing 50Mm Dia Medium Gi Pipe With Suitable Heavy Type Gi Specials Such As Bend, Reducer Etc As Silencer Extensionpipe Including Cutting In To Required Length,And Supply And Providing Ms Flanges Having 12 Mm Thickness As Required, Including Conveyance Charges And Paintingthe Pipe Etc , 5.4:Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , 90.12.7.1:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.2 Core 4 Sq Mm With Factory Made Clamp , 90.12.5.1:Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1Kv Grade Of The Following Sizes In The Existing Rcc/ Hume / Stone Ware/ Gi/ Dwc Pipe As Required.2 Core 4 Sq Mm , 90.12.7.41:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , 90.12.7.32:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.3.5 Core 120 Sq Mm , Od230683/2023-2024:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Copper Control Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.10 Core 1.50 Sq Mm With Factory Made Clamp , 90.12.1.41:Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground Including Excavation Of Trench Of Size 35 X 75 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering (In Ordinary Soil).4 Core 16 Sq Mm , 90.12.1.32:Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground Including Excavation Of Trench Of Size 35 X 75 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering (In Ordinary Soil).3.5 Core 120 Sq Mm , 90.12.2.32:Supply And Laying Of One Number Additional Pvc Insulated And Pvc Sheathed Armoured Aluminium Powercable Of 1.1Kv Grade Of The Following Sizes In Ground In The Same Trench In One Tier Horizontal Formation Including Wideningthe Trench By 20 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering (In Ordinary Soil)3.5 Core 120 Sq Mm , Od230682/2023-2024:Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Copper Control Cable Of 1.1Kv Grade Of The Following Sizes In The Existing Rcc/ Hume / Stone Ware/ Gi/ Dwc Pipe As Required.10 Core 1.50 Sq Mm , Od170637/2023-2024:Supplying And Providing Earth Clamps For Siemens/ Tropodur Type Cable Glands Of Suitable Length And Other Dimensions Noted Along With Eachsize Of Glands For The Following Sizes Of Cables As Required.25 To 95 Sq Mm With 20Mm Wide X 1.20 Mm Thick Clip , Od209942/2023-2024:Supply And Providing Copper Earthing Clip 12Mm Widex1mm Thick Suitable For 4 Sq Mm To 16 Sq Mm Cable Gland Connection Etc In Correct Alignment. , Od192718/2023-2024:Supply ,Conveyance And Fabrication Of Ms. Clamp / Bracket Using Ms Angle / Flat/Rode And Bend/ Weld In Shape And Fitting Charges Of The Same In Required Position Using Bolts And Nuts Including Painting As Required . , 90.16.1.2:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.65 Mm Copper Conductor (12 Swg) , 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , 90.16.3.9:Supply And Clamping The Following Size Of Strips On Surface Of Wall/ Parapet/ Existing Cable Tray Using Clamps Fabricated From 20 X 3 Mm Gi Flat Duly Painted Or Heavy Duty Gi Spacer Saddles Spacing Of Clamps Not Exceeding 1 M, Making Good The Damages, Colour Washing Etc. As Required ( For Horizontal Run)25 X 3 Mm Copper Strip , 90.16.2.1:Supply And Laying Of The Following Sizes Of B Class Gipipe Laid 0.6 M Below Ground Level Including Excavating Trench Of Suitable Size And Refilling Etc, As Required.15.Mm Dia. G.I Pipe ( Medium Class) , 90.16.2.4:Supply And Laying Of The Following Sizes Of B Class Gipipe Laid 0.6 M Below Ground Level Including Excavating Trench Of Suitable Size And Refilling Etc, As Required.40 Mm Dia G.I. Pipe ( Medium Class) , Od170858/2023-2024:Supply And Providing 5Kg Dry Chemical Powder Type Fire Extinguisher With Hose And Clamp And Fix It To The Wall As Required , Od170859/2023-2024:Supply And Providing First Aid Chart Duly Framed And Placed In Required Place For Clear Vision , 90.12.9.3:Supplying, Laying And Jointing Of The Following Sizes Of Double Wall Corrugated (Dwc) Pipes Made Out Of Hdpe Conforming To Is 14930 Part Ii For Mechanical Protection To Underground Power Cables With All Required Accessories In Ground In The Existing Trench63/50 Mm Or Nearest Size , 90.12.9.2:Supplying, Laying And Jointing Of The Following Sizes Of Double Wall Corrugated (Dwc) Pipes Made Out Of Hdpe Conforming To Is 14930 Part Ii For Mechanical Protection To Underground Power Cables With All Required Accessories In Ground In The Existing Trench50/38 Mm Or Nearest Size , Od170860/2023-2024:Supply And Providing 9 Ltr Capacity Gi Bucket Painted With Post Office Red And Write Letter With Paint As Required And Filling Fine Sand In Required Quantity In Position Using Coch Screw Etc , 9.1.24:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 95 Sq. Mm (45Mm) , 9.1.33:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm (28Mm) , 1.27.2:Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75mm) , 1.24.3:Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch , 1.24.5:Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet , 9.1.1:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.2 X 6 Sq. Mm (19Mm) , 9.1.11:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 X 50 Sq. Mm (32Mm) , 2.10.1:Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, &Quot;C&Quot; Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Od230684/2023-2024:Charges For Getting Approval From The Electrical Inspectorate Including Preparation Of All Drawings Including Schematic Circuit Diagram And All Liaison Works (1 No 15Kvaand1 No 100Kva ) ( Actual Amount Paid On Production Of Original Bill/Challan/Invoice )

Key Value

Document Fees
Refer document
EMD
INR 37710.0 /-
Tender Value
INR 15.08 Lakhs /-

BOQ Items

Work Name:Annual Plan-So 325/24- GP Kadungalloor --Supply and providing Gen Sets inCommunity hall and addl Cremetorium at Kadungalloor. -General Electrical Work
Sl. No. Item Description
1Electrical
214.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
314.3:Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres.
414.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
514.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
6OD209850/2023-2024:Supply Installation Testing and Commissioning and Trail run of 15KVA/12 KWsilent Three phase 440 V, 1500 RPM , 0.8 Power factor, 50 HZ Canopised Diesel Comprising Generation unit ofASHOK LEYLAND Model AL2CDG1Diesel engine developing 21BHP at 1500 RPM coupledwithLEROY Somers/ Crompton15 KVA/12 KW Alternator 415 Volts- 3 Phase, complete with standard accessories mounted on a Channel Iron Base Frame, Fuel Tank, Standardcontrol Paneland Battery battery leads with battery Charger etcincludingSupply and fitting ATS/ AMF Panel etc complete as required with CPCB approvedAcoustic enclosure complete with stdcontrol panel, Sound level-75 dB (A) at one metre from enclosure surface in free field condition as per ISO 8528 and maintain a Warranty of 24 months from the date of commissioning including 5 years engine critical parts warranty etc as as required.
7OD170316/2023-2024:Supply Installation Testing and Commissioning and Trail run of 100 KVA/ 80 KWsilent Three phase 440 V, 1500 RPM , 0.8 Power factor, 50 HZ Canopised Diesel Comprising Generation unit ofASHOK LEYLAND Model AL6DTIDG1 Diesel engine developing 126.01 BHP at 1500 RPM coupledwithLEROY Somers/ Crompton100 KVA /80 KW Alternator 415 Volts- 3 Phase, complete with standard accessories mounted on a Channel Iron Base Frame, Fuel Tank, Standardcontrol Paneland Battery battery leads with battery Charger etcincludingSupply and fitting AMF Panel etc complete as required with CPCB approvedAcoustic enclosure complete with stdcontrol panel, Sound level-75 dB (A) at one metre from enclosure surface in free field condition as per ISO 8528 and maintain a Warranty of 24 months from the date of commissioning including 5 years engine critical parts Warranty as required.
8OD193969/2023-2024: Supply, conveying & fixing 100 mm dia medium GI pipe with suitable heavy type GI specials such as bend, reducer etc as silencer extensionpipe including cutting in to required length,and supply and providing MS flanges having 12 mm thickness as required, including conveyance charges and paintingthe pipe etc
9OD209887/2023-2024: Supply, conveying & fixing 50mm dia medium GI pipe with suitable heavy type GI specials such as bend, reducer etc as silencer extensionpipe including cutting in to required length,and supply and providing MS flanges having 12 mm thickness as required, including conveyance charges and paintingthe pipe etc
105.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1190.12.7.1:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp
1290.12.5.1:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 4 sq mm
1390.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
1490.12.7.32:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm
15OD230683/2023-2024:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper control cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.10 core 1.50 sq mm with factory made clamp
1690.12.1.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 16 sq mm
1790.12.1.32:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 120 sq mm
1890.12.2.32:Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including wideningthe trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 120 sq mm
19OD230682/2023-2024:Supply & laying of one number PVC insulated and PVC sheathed armoured copper control cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.10 core 1.50 sq mm
20OD170637/2023-2024:Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with eachsize of glands for the following sizes of cables as required.25 to 95 sq mm with 20mm wide x 1.20 mm thick clip
21OD209942/2023-2024:Supply and Providing copper earthing clip 12mm widex1mm thick suitable for 4 Sq mm to 16 Sq mm cable gland connection etc in correct alignment.
22OD192718/2023-2024:Supply ,conveyance and fabrication of MS. clamp / bracket using MS angle / flat/rode and bend/ weld in shape and fitting charges of the same in required position using bolts and nuts including painting as required .
2390.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
2490.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
2590.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
2690.16.2.1:Supply and laying of the following sizes of B class GIpipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
2790.16.2.4:Supply and laying of the following sizes of B class GIpipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class)
28OD170858/2023-2024:Supply and providing 5KG Dry chemical powder type Fire Extinguisher with hose and clamp and fix it to the wall as required
29OD170859/2023-2024:Supply and providing First Aid Chart duly framed and placed in required place for clear vision
3090.12.9.3:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench63/50 mm or nearest size
3190.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
32OD170860/2023-2024:Supply and providing 9 Ltr capacity GI bucket painted with Post office Red and write letter with paint as required and filling fine sand in required quantity in position using coch screw etc
339.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
349.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
351.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
361.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
371.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
389.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
399.1.11:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 50 sq. mm (32mm)
402.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
41OD230684/2023-2024:Charges for getting approval from the Electrical Inspectorate including preparation of all drawings including Schematic circuit diagram and all liaison works (1 no 15KVAand1 NO 100KVA ) ( Actual amount paid on production of Original bill/challan/invoice )