Tender For Repair Maintenance Of Summer Appliances Installed At Dgrr Casd Dg Ncc 512 Lt Ad 7 Jat 422 Fd Hosp Esd 262 Trasit Camp Supply Depot 972 Tpt Coy Parade Ground 1811 Pioneer 19 Bihar Cod 505 Abw Cvd Hqtg Eme And 6 Sikh Under Ge (U) Plant An, delhi-Delhi

Military Engineer Services-MES has published Tender For Repair Maintenance Of Summer Appliances Installed At Dgrr Casd Dg Ncc 512 Lt Ad 7 Jat 422 Fd Hosp Esd 262 Trasit Camp Supply Depot 972 Tpt Coy Parade Ground 1811 Pioneer 19 Bihar Cod 505 Abw Cvd Hqtg Eme And 6 Sikh Under Ge (U) Plant An. Submission Date for this Tender is 23-01-2024. AMC of Air Condition Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

41298843
Corrigendum : Tender For Repair Maintenance Of Summer Appliances Installed At Dgrr Casd Dg Ncc 512 Lt Ad 7 Jat 422 Fd Hosp Esd 262 Trasit Camp Supply Depot 972 Tpt Coy Parade Ground 1811 Pioneer 19 Bihar Cod 505 Abw Cvd Hqtg Eme And 6 Sikh Under Ge (U) Plant An
Open Tender
Indian
Delhi
delhi
23-01-2024

Tender Details

Repair Maintenance Of Summer Appliances Installed At Dgrr Casd Dg Ncc 512 Lt Ad 7 Jat 422 Fd Hosp Esd 262 Trasit Camp Supply Depot 972 Tpt Coy Parade Ground 1811 Pioneer 19 Bihar Cod 505 Abw Cvd Hqtg Eme And 6 Sikh Under Ge ( U ) Plant And Machinery

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 98040.0 /-
Tender Value
INR 49.02 Lakhs /-

BOQ Items

Name of Work: REPAIR/ MAINTENANCE OF SUMMER APPLIANCES INSTALLED AT DGRR, CASD, DG NCC, 512 LT AD, 7 JAT, 422 FD HOSP, ESD, 262 TRASIT CAMP, SUPPLY DEPOT, 972 TPT COY, PARADE GROUND, 1811 PIONEER, 19 BIHAR, COD, 505 ABW, CVD, HQTG EME AND 6 SIKH UNDER GE (U) PLANT AND MACHINERY, DELHI CANTT-10
Sl. No. Item Description
1Disconnecting from mains and taking downfor servicingofWater Cooler ofCapacity 40/40, 40/80, 60/120, 150/150,Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs,fan andblower, etc., andkeepingthe Water coolerunit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed . Note :- 1. Replacement of defectivespares for making the water cooler units in satisfactory working condition will be measured & paidseparately under relevant items and Transportation & labour charges for taking down old spares and fixing of new sparesshall deemed to be included in unit rate quoted above.
2Supply onlyfollowing new spare parts of Water cooler unit ofcapacity 40/80 to 60/120 Ltrs:-
3Starting relaysuitable for any capacity of water cooler. (Make :- Sri Ram/Renutrol/Micro Tech.)
4Starting Capacitor 25 MFD. (Make :- Usha/Epcos/Keltron)
5Running Capacitor 10 MFD . (Make:-Usha/Epcos/Keltron)
6PVC flexible drainHose pipe 40 mm. (Make :- Prayag/ Supreme/ Polytuff)
7Condenser fan blade aluminium body for Motorsuitable for any capacity of water cooler . (Make :- Tipcon/ Usha/Epcos/Keltron)
8Over load protector devicesuitable for any capacity of water cooler. (Make :- Sri Ram/Renutrol/Micro Tech.)
9Over load protector devicesuitable for any capacity of water cooler. (Make :- Sri Ram/Renutrol/Micro Tech.)
10Tharmostat switchsuitable for any capacity of water cooler. (Make :-Indfoss/Renutrol/Godrej.)
11Self closing chromium plated push taps suitable for any capacity of water cooler.(Make :- Usha/Prayag/ Cera/ Essco) Note for item Nos. 2.01 to 2.09 - Materials of item Nos. 2.01 to 2.09 to be incorporated in item No 1.00 here-in-before
12Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity150/150 Ltrs from any location andsupply installation & testing of new sealed unit compressorof similar capacity in same locationalongwith test Certificate from manufacturer and cleaning of condenser by machine doing vacum the fully system and supply and charging of oil gas and other necessary lubricants including reconnecting the electric and water connections, transportaion& testing complete all as directed by. (Make :- Tecumseh/Emerson/LG.)
13ditto- all as per item No. 3.00 above butWater coolerofcapacity 60/120 Ltrs.
14ditto- all as per item No. 3.00 above butWater coolerofcapacity 40/80 Ltrs.
15ditto- all as per item No. 3.00 above butWater coolerofcapacity 40/40 Ltrs.
16Disconnecting the electric mains and taking out unserviceable condenser fan motorSuitable for Water cooler of capacity 150/150 Ltrs and supply and replace with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as directed. (Make :-AUE, Crompton Greaves / Cool Master)
17All as per item No. 7.00 above but Suitable for Water cooler of capacity 60/120 Ltrs.
18All as per item No. 7.00 above but Suitable for Water cooler of capacity 40/80 Ltrs.
19All as per item No. 7.00 above but Suitable for Water cooler of capacity 40/40 Ltrs.
20Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water/Coolers of capacity 60/120 Ltrs complete all as specified & as directed.
21All as per item No 11.00 above but for Water coolers of capacity 60/120 ltrs
22All as per item No 11.00 above but for Water coolers of capacity 40/80 ltrs
23All as per item No 11.00 above but for Water coolers of capacity 40/40 ltrs
24Dismantling the evaporator/cooling coil for water cooler of any capacity, checking the leakages of gas and rectify the leakages by brazing or as other manner and refixing in same position complete all as specified & as directed.
25Cleaning & removing the existing paint of water cooler of any capacity by rubbing & preparing the surface smooth & applying one coat of zinc chrome primer and two coats of synthetic enamel paint (1st grade quality) by spray gun machine of colour as approvedcomplete all as specified & as directed. (Make of paint and primer :- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
26Taking up or down steel tubing and connections and removing off site15mm bore of pipecomplete all as specified and as directed.
27Spply and fixinggalvanised steel tubing 15 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.)fixed on wall or floor complete all as specified and as directed. (Make:- JINDAL STEEL/ PRAKASH/ TATA/ OSWAL.)
28Supplying and fixing in repairs stop valve 15mm bore dia, fancy type chromium plated with long shank and cup (concealed type), screwed both ends for iron pipe or for unionscomplete all as specified and as directed. (Make:-JAQUAR/ KOHLER/ CERA/ MARC)
29Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections pipe of 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed. (Make:- Prayag/ Polytuff/ Supreme)
30Material and labour for detecting of leakages of gases in Water cooler, Refrigerator, deep freezer of any capacity at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition.
31Taking down desert cooler of any type (Steel body/Plastic body) and any capacity from any height / floor andrefixing the same in same location after repair work/ overhauling all as required at site. Note:- Repair work not included in the quoted rate.
32Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface.Repainting the complete desert coolers ie side panel, bracket, body & desert cooler stand with two coats of synthetic enameled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “ GE(U) P&M (MES)” letter size of 50mm height in stencil in black/white including servicingandgreasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as per site requirement. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
33Supply and fixing in repairs wood wool padapproximate weight 800 - 900gms of size 24” sweep desert cooler as per existingcomplete all as specified and directed.
34ditto- all as per item No 24.00 above but approximate weight 700 - 800gms and20” sweep.
35Supply and fixing in repairs submersible pump motor 230 Volts , single phase, AC suitable for Plastic body/Steel body Desert cooler complete all as specified & as directed. (Make :- Bajaj/ Crompton/ Khaitan.)
36Supply and fixing in repairs of exhaust fan motor copper woundedhaving 1400 RPM, 150 watts with 500mm sweep suitable for operation on 230 volts, 50Hz, AC supply including fan brackets/ clamps of suitable size and all fixing accessories complete all as specified & as directed. (Make:- Khaitan/ Crompton/ Cool master.)
37Supply and fixing in repairs front grill for desert cooler of approved make complete with 5 Amp switch, three speed regulator including indicator lamp complete all as specified and directed.
38Supply & fixingin repairs GI wire mesh for desert cooler pad (Set of Three).
39Supply & fixing in repairsPVC pipe for connecting pump and water distributor of size 15 mm complete all as specified & as directed. (Make:- Prayag/ Supreme/ Prince).
40Supply & fixingin repairsPVC elbow for desert cooler of suitable size complete all as specified & as directed.
41Supply & fixingin repairs PVC 4 Way distribution cross for desert cooler complete all as specified & as directed.
42Supply & fixingin repairs flexible copper conductor cable, 3 corePVC insulated & PVC sheathed of size 1.5sqmm complete all as specified and directed. (Make -Polycab/Kalinga Premium/Plaza).
43Supply & fixing in repairs desert coolers fan blade of 18 inch sweep of plastic bodycomplete all as specified & as directed..
44ditto- all as per item No 34.00 here-in-before but 20 inch sweep.
45Supply and fixing in repairs side panel of desert cooler of 20” sweep made out with GI sheet of 20 SWG duly painted with two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer complete all as specified & as directed. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
46Supply and fixing in repairs switch piano flush type single pole one way 5Amp / 6 Amp 230 V for desert cooler all as directed. (Make :- Anchor/ Kinjal/ Havells).
47Supply and fixing in repairs 3 pin plug top 5 Amp, 230V for desert cooler complete all as specified and directed (Make :- Anchor/ Kinjal/ Havells).
48Supply and fixing in repairs cooler fan motor bracket sets made up as existing includingpaintingcomplete all as specified and directed.
49Material and labour for out door stand for desert cooler of any capacity made up of angle iron frame of any size grouting on wall or floor as directed and apllying of two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer including taking down old unserviceable one complete all as specified and directed.
50Supply & fixing in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 20 SWG PGI Sheet alongwith PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e, side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with "GE (U) P&M (MES)" letter size of 50mm height in stencil in black/white all as specified and directed. (Make of paint and primer :- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
51Taking downfor servicingof split type AC 1.5/2 TR Capacityincluding cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing connections from heating mode to cooling mode or vice-versa and keepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed .
52Taking downfor servicingofWindow type AC 1.5/2 TR Capacityincluding cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa andkeepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing positioncomplete all specified and as directed. Notes for Ser Item No 42 & 43 :- (i) Replacement of defectivespares for making the AC units in satisfactory working conditionwill be measured & paidseparately under relevant items and Labour charges for taking out old spares & refixing of new sparesshall deemed to be included in unit quoted rate. (ii) Penaltywill be charged for not attending complaint from 12 Hoursto 24 hours Rs. 500/- each complaint. Furtherif complaint not attended and rectifiedwithin 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioningtime of complaint,for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues.
53Supply only 15mm dia PVC pipe medium grade including fittings. (Make:- Prayag/ Supreme/ Prince.)
54Supply only printed circuit board (PCB) compatible with electric accessories and sensors for split type AC/ window type AC of capacity of 1.5/ 2 TR.
55Supply only printed circuit board (PCB) compatible with electric accessories and sensors suitable for indoor of inverter type split type AC of capacity of 1.5/ 2 TR.
56Supply only printed circuit board (PCB) compatible with electric accessories and sensors suitable for outdoor of inverter type split type AC of capacity of 1.5/ 2 TR.
57Supply only starting capacitors 80-100 MFD. (Make:- Epcos/ Usha/ Keltron.)
58Supply only starting capacitors 100-120 MFD. (Make : – Usha/ Keltron/Epcos)
59Supply only running capacitor 50+6 MFD. (Make:- Epcos/ Usha/ Keltron.)
60Supply only running capacitor 45+5 MFD. (Make:- Epcos/ Usha/ Keltron.)
61Supply and fixing in repairs of condenser motor 1/3 HP suitable for window type AC double shaft. (Make:- AUE/ Crompton Greaves/Cool Master.)
62Supply only starting relay SR-1622. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.)
63Supply only running capacitor 36 MFD. (Make:- Epcos/ Usha/ Keltron.)
64Supply only thermostat switch 2059/ 2064/ 2054. ( ( Make :- Indfoss/ Renutrol).
65Supply only copper filter double capilary pencil type.
66Supply only regulator knob suitable for 1.5TR /2.0 TR capacity window AC. Note for item Nos. 44 to 57 :- Materials of item Nos.44 to 57 to be incorporated in item No 42 & 43 here-in-before.
67Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the window type Air Conditioner of Cap2 Ton,of any make any type from any locationandSupply , Installingand testing of new sealed unit compressorandone yearguarantee certificate includingcleaning and removing dust/dirt from the cooling coil condenser coilwith necessary modification capillary tube etc&Charging of Gas R-22/R-410A/R-32 and commissioning complete all as specified & directed. ( Make:- Emerson /Tecumseh/LG) Note :- Transportation Charges from siteto trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
68ditto- all as per item No. 58.00 abovebut window type Air Conditioner ofCapacity1.5 TR.
69ditto- all as per item No. 58.00 abovebut spilt type Air Conditioner ofCapacity 2 TR.
70ditto- all as per item No. 58.00 above but spilt type Air Conditioner Capacity 1.5 TR.
71Supply & fixing in repairs 1.5 TR capacity window type AC kit including condenser coil, cooling coil, front grill blower motor, chasis, base plate complete set except compressor. (Make:- Nepoleon/ Commander/ Speed.)
72ditto- all as per item No. 62.00 abovebut window type Air Conditioner ofCapacity 2.0 TR. (Make:- Nepoleon/ Commander/ Speed.)
73Taking down unserviceable indoor unitof split AC of any make andsupply & fixing new indoor unit complete set suitable for 1.5 TRcapacity complete all as directed . (Make:- Nepoleon/ Commander/Camipro.)
74All as per item No. 64.00 above but spilt type Air Conditioner of capacity2 TR. (Make:- Nepoleon/ Commander/Camipro.)
75Supply and fixing in repairs of1.5TR capacity split type Air Conditioner outdoor kit including condenser coil, blower motor, chasis, base plate complete set except compressor. (Make:- Nepoleon/ Commander/Camipro.)
76ditto- all as per item No. 66.00 above but spilt type Air Conditioner of capacity2 TR. (Make:- Nepoleon/ Commander/Camipro.)
77Material and labour for sub main wiring with two runs of single core 2.5 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded,unsheathed1100 volts grade in PVC casing caping(heavy grade) of adequit size with all fittings and casing capingaccessories of surface type including one run 2.5 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694)as earth wire including taking down old unservisible sub main wiring complete all as specified and as directed. (Make of cable:- RR Kabel/Finolex/ Havells/ Polycab/ KEI Industries.) PVC Casing Caping :- Finolex/ Precision/ Prestoplast/ Supreme)
78Material and labour for sub main wiring with two runs of single core 4.0 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded,unsheathed1100 volts grade in PVC casing caping(heavy grade) of adequit size with all fittings and casing capingaccessories of surface type including one run 4.0 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694)as earth wire including taking down old unservisible sub main wiring complete all as specified and as directed. (Make of cable:- RR Kabel/Finolex/ Havells/ Polycab/ KEI Industries.) PVC Casing Caping :- Finolex/ Precision/ Prestoplast/ Supreme)
79Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded,unsheathed1100 volts grade in PVC casing caping(heavy grade) of adequit size with all fittings and casing capingaccessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694)as earth wire including taking down old unservisible sub main wiring complete all as specified and as directed. (Make of cable:- RR Kabel/Finolex/ Havells/ Polycab/ KEI Industries.) PVC Casing Caping :- Finolex/ Precision/ Prestoplast/ Supreme) Note for item no. 68 to 70 :- (i) Two runs of cable with one runs earth wire and PVC casing capping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing capping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.
80Supply & fixing in repairs industrial type plug with two pin and earth confirming to IS/IES-309 of capacity 20 Amps complete all as specified and as directed (Make : Schneider/ Legrand/ ABB/ Seimens/L&T)
81Supply and fixing in repairs metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps iincluding taking down old unservisible metal clad socket complete all as specified and as directed. (Make : Schneider/ Legrand/ ABB/ Seimens/L&T)
82Supply and fixing in repairs MCB SP 240 volts 6 to 32 Amps, 10 kA, "C" curve complete all as specified and as directed. (Make : Schneider/ Legrand/ ABB/ Seimens/L&T)
83Supply & fixing in repairs of metal clad socket of 20/ 32Amps complete all as specified & as directed. (Make:- L & T/ Legrand/ C & S/ ABB/Seimens)
84Material and labour for detecting of leakages of gases in window type /Split Type AC unit of capacity 1.5/2 TR at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition. Note:- Refrigerant for toping up/ filling in will be measured and paid seperately under relevant items in the Schedule.
85Supply and fillingrefrigerant gas R-22/R-410A/R-32/R-134A in window type /Split Type AC unit of capacity 1.5/2 TR, Deep Freezer, Refrigerator, Water Cooler of any capacity complete all as specified and as directed. (Make :- Mefron/Floron/ Refron.)
86Supply and fixing in repairs of front grill of window type AC of capacity 1.5 TRcomplete all as specified and directed.
87Supply and fixing in repairs of front grill of window type AC of capacity 2.0 TRcomplete all as specified and directed.
88Taking down unserviceable reversible valve for split/ window type AC of capacity 1.5TR and supply & fixing new reversible valve with solenoid coil including required copper pipe complete all as specified and directed. (Note:- Supply & filling of refrigerant gasshall be measured and paid under relevent item.)
89ditto- all as per item No. 79.00 above but spilt/window type Air Conditioner of capacity2 TR.
90Supply & fixing heavy duty copper pipe 6mm (1/4") dia/ bore complete including insulation brazing, welding, nuts,bolts and screws of required size complete all as specified and directed. (Make:- MALASIA/CAMIPRO/ DIAMOND/STAR)
91ditto- all as per item No. 81.00 above but copper pipe 12mm (1/2") dia/ bore.
92ditto- all as per item No. 81.00 above but copper pipe 15mm (5/8") dia/ bore.
93Supply & fixing in repair Indoor Air blower motor for Split type AC 1.5 TR & 2 TR capacity complete all as specified & as directed. (Make :- AUE/ Crompton Greaves/ Cool Master.)
94Supply & fixing in repair Window AC air blower motor for 1.5 TR & 2 TR capacity AC complete all as specified & as directed. (Make :- AUE/Crompton Greaves/Cool Master.)
95Supply & fixing in repairs Window AC condenser fan blade plastic body for 1.5 TR & 2 TR capacity AC complete all as specified & as directed.
96Supply & fixing in repairsSplit AC Condenser fanblade plastic body for 1.5 TR & 2 TR capacity AC complete all as specified & as directed.
97Supply & fixing in repairs running capacitor of 2.5 MFD capacitycomplete all as directed. (Make :- USHA/ EPCOS/ KELTRON)
98Supply & fixing in repairs running capacitor of 4 MFD capacitycomplete all as directed. (Make :- USHA/ EPCOS /KELTRON)
99Supply & fixing in repairsrunning capacitor of 6 MFDcapacitycomplete all asdirected. (Make :- USHA/ EPCOS/ KELTRON)
100Supply only remote control including battery for split AC Cap 1.5/2 TR of make as per site requirement and replace of old one complete all as directed . (Make :- LG/ Blue Star/ Voltas)
101Supply & fixing in repairs plastic louvers (Front panel)for Window type AC of capacity 1.5/2 TR complete all as directed.
102Supply & fixing in repairs of selector switch for fan/cooling of Window AC 1.5/2 Ton complete all as specified & as directed.
103Supply & fixing in repairs of suctionand discharge valve set of size 15mm (5/8""), 6mm (1/4"") and 12mm (1/2"")for Split AC 1.5/2 TR capacity complete all as directed. (Make:- LG/ VOLTAS/ BLUE STAR/ HITACHI.) Note:- (i) 15mm (5/8"") or 6mm (1/4"") and 12mm (1/2"") made one set (ii) Supply & filling of refrigerant gasshall be measured and paid under relevent item.
104Material and labour for 4 mm thick plywood of grade BWR, type BB including necessary fixing accessories and taking down old one and applying two coat of synthetic enamel paint(1st grade quality) over a coat of pink primer complete all as specified & as directed. (Make:- Century/ Dura/ Green ply/ Kitply.)
105Disconnecting the mains and taking out the unserviceable condenser coilof window type AC of capacity 1.5/ 2TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. (Make:-Suitable for Voltas/Carrier/LG/ Hitachi/ Blue Star)
106ditto- all as per item No. 96.00 above but spilt type Air Conditioner Capacity 1.5/ 2 TR.
107Dismantling the evaporator/cooling coil of window type Air Conditioner of capacity 1.5/ 2TR, checking the leakages of gas and rectify the leakages by brazing or as other manner and refixing the same complete all as specified & as directed.
108ditto- all as per item No. 98.00 above but spilt type Air Conditioner Capacity 1.5/ 2 TR.
109Taking down unserviceable insulation for copper pipe of any dia, supply and fixing new insulation for copper pipes suitabale for Split AC of capacity from 1.5 to 2.0 TR complete all as specified and directed.
110Taking down unserviceable contactor for split type AC of capacity 1.5 TR/ 2.0TR, supply and fixing new contactor single phase suitable for split type ACcomplete allas specified and directed.
111Disconnection and removing of serviceable window type AC of capacity 1.5 TR/ 2.0TR of any make and model along with stabilizer from its position and fixing the same in other location including all other fixing accessories and testing complete allas specified and directed.
112Disconnection and removing of serviceable split type AC of capacity 1.5 TR/ 2.0TR of any make and model along with stabilizer (Indoor & Outdoor Unit) from its position and fixing the same in other location including all other fixing accessories and testing complete allas specified and directed.
113Disconnecting the unserviceable PCB compatible from existing Window/ Split type AC of capacity 1.5/ 2TR and refixing after necessary repair for satisfactory functioning of the AC unit complete allas specified and directed.
114Disconnecting the unserviceable PCB compatible from existing Window/ Split type AC invertor Type of capacity 1.5/ 2TR and refixing after necessary repair for satisfactory functioning of the AC unit complete allas specified and directed.
115Dismantling and removing defective burnt blower unit motor ofcapacity 1.5/ 2.0 TR of any make ofwindow type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete allas specified and directed.
116Dismantling and removing defective burnt blower unit motor ofcapacity 1.5/ 2.0 TR of any make of indoor units of split type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete allas specified and directed.
117Dismantling and removing defective burnt blower unit motor ofcapacity 1.5/ 2.0 TR of any make of outdoor units of split type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete allas specified and directed .
118Supply & fixing in repairs of blower fan blade of indoor unit for Split 1.5 TR & 2 TR capacity complete all as specified & as directed.
119Supply and fixing in repair GI Sheet Tray Suitable for Window/ Split Acs of any capacity as per Sample as directed.
120Disconnecting from mains and taking downfor servicingof Refrigerator/Deep freezerofCapacity 165/180/195/310/330/450 and 500 Ltrsincluding detecting the leakage of gas and refilling of refrigerant ,cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., andkeepingthe Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed. Note :- 1. Replacement of defectivespares for making the Refrigerator/ Deep Freezer units in satisfactory working condition will be measured & paidseparately under relevant items and Labour charges for taking out old spares and fixingof new sparesshall deemed to be included in unit rate quoted.
121Supply onlyfollowing new spare parts of Refrigerator/Deep freezer 165/180/195/310/330/450 and 500 Ltrs capacity:-
122Thermostat switchwith Knob. ( Make :- Indfoss/ Renutrol).
123Starting relay 1/6 H.P.Open type with O.L.P. (Make :-Renutrol/ Sri Ram/ Microtech).
124Starting relay 1/8 H.P. open type with O.L.P. (Make :-Renutrol/ Sri Ram/ Microtech).
125Copper filter single capilary pencil type.
126Vegetable tray PVC for 165 to 330 Ltr capacity (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.).
127Defrost tray for refrigerator capacity 165 to 330 Ltr (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.).
128PVC ice tray flexible. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
129Refrigerator bottle shelf for 165 to 330 ltr capacity (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
130Waste water tray suitable for different type of Refrigerator. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
131Freezer door for 165/180/195 Ltr capacity. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
132Freezer door for 280/300/330 Ltr capacity. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
133Door Lock for refrigerator 165 to 330 ltrs. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
134Door switch for refrigerator 165 to 330 ltrs . (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
135Interior light fittings with bulb. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
136Door handle suitable for 165 to 330 Ltrs. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
137Refrigerator Glass shelves of capacity 165/180/195 Ltrs. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
138Refrigerator Glass shelves of capacity 280/300/310/330 Ltrs. (Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
139Printed circuit board (PCB) compatible with electric accessories and sensors suitable for inverter type Refrigerator of capacity 195/210/250/308/300 Ltrs. Note for item Nos. 112.01 to 112.18 :- Materials of item Nos. 112.01 to 112.18 to be incorporated in item No 111.00 here-in-before
140Disconnecting from mains and taking down the unserviceable compressorunit of Refrigerator of any make and type and providing New Compressor suitable for 165 to 195 ltr capacityalongwith test certificate from manufacturer including supply of therefrigerant gas R-134A and filling and replacement of filter and put in working condition all as directed. (Make :- Tecumseh/LG/Godrej.) Note :-The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor"s repair workshop and back.
141All as per item No. 113.00above but following capacity of Refrigerator:-
142Refrigerator 280/300/310/330 Ltrs capacity.
143Deep Frteezer 400 Ltrs capacity.
144Deep Freezer 500 Ltrs capacity.
145Taking out unserviceable evaporator /freezer from the refrigerator & supply & fixing evaporator/freezer made out of aluminium press type of capacity 280/300/310/330/400 and 500 ltrwith freezer frame and door including connection, complete all as specified & as directed. (Make - Whirlpool/Godrej/Kelvinator/LG/Sumsung.)
146ditto- all as per item No. 115.00 but capacity of the refrigerator 165 to 195Ltrs capacity.