Tender For Creation Of 250 Kva Sub Station At Kanuyan Dhara, poonch-Jammu And Kashmir

Power Development Department has published Tender For Creation Of 250 Kva Sub Station At Kanuyan Dhara. Submission Date for this Tender is 13-01-2024. Substation Tenders in poonch Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

41283520
Corrigendum : Tender For Creation Of 250 Kva Sub Station At Kanuyan Dhara
Open Tender
Indian
Jammu And Kashmir
poonch
13-01-2024

Tender Details

Tender For Creation Of 250 Kva Sub Station At Kanuyan Dhara- Erection of 11 KV (HT) Line(Note: For detailed specifications please refer attached SBD which forms a part of the tender) 2 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard) 3 G.I Channel/Flat/Angle in shape of Fabricated X-arm Top Bracket, Angle Braced, Clamp etc. 4 Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard) 5 Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard) 6 Supplying and fixing of Galvanized Nuts and Bolts of sizes. 7 Supplying and fixing of Galvanized Stay Set with 50X8 mm Stay Clamp, Guy insulator (02 Nos) anchor plate (200x200x6mm) nut bolts, 2 nos. Turn buckles, 1.80 m long 16 mm diameter solid GS Stay rod & 7/3. 15 dia GI Stranded wire complete 8 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing, binding and Jumperig of conductor including joints with PG clamps of required size30 mm2 ACSR ( Weasel) (As per recommended IS/REC Standard) 9 Supply and installation of 11 KV Link Set, 3-phase, 100A (As per recommended IS/REC Standard) 10 Earthing complete, G.I Rod 20 mm 2.5 Mtr. Long through G.I Wire 11 Cement Bottoming 1:2:4 Mix as per REC Standard 0.5 Cubic Mtr.Per Pole 12 Anti Clamping Device 13 Erection of 11/0.433 kV Distribution Transformer(Note: For detailed specifications please refer attached SBD which forms a part of the tender) 14 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 250 KVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Copper Wound, oil filled, with LT cable termination box with detachable Copper Gland Plate.(As per recommended IS/REC Standard) (with one year warranty) 15 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard) 16 Supply and installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type (As per recommended IS/REC Standard) 17 Supply and installation of 11 kV Horn,Gap Fuse Set, 3-phase, 100A (As per recommended IS/REC Standard) 18 Supply and installation of 11 kV Link Set, 3-phase, 100A (As per recommended IS/REC Standard) 19 Supply and fixing of Un Armoured Single Core PVC Cable 220 mm2 alongwith 12 no. Al. thimble 120 mm2 20 Supplying and fixing of Galvanized Nuts and Bolts of sizes. 21 Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard) 22 Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard) 23 Supplying and fixing of Angle Belt 1.5 Mtr for the protection of transformer 24 Supply and fixing of LT Distibution fuse set of standard making using clamps/thimbles with Brass Bolts and washers etc. Complete job as per REC standard (Drilling of holes Prohibited). 25 Supplying and fixing of Angle Brace for transformer bed 26 Supplying and fixing of Cross X-mar 2.8. Mtr 27 Cement Bottoming 1:2:4 Mix as per REC Standard 0.5 Cubic Mtr.Per Pole 28 Excavation of Earthing Pits of dia = 650 mm and depth= 3000 mm, Supplying and fixing of 3 No. sub station earthingby GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 mm 1 nofor neutral earthing and 25X3 mm 2 nos (for 2 Nos transformer body earth, 2 Nos Pole earth, 1 no. LA Earth and 1 no. GO handle earth). (Note: For LA Earth 1 pipe shall be kept separate) GI Nuts, Bolts and Clamps, refilled with earth enhancement materials and earthing chamber made of brick masonary with RCC Slab Cover. (As per recommended IS/REC Standard) 29 Erection of 1kM of LT Line on Conductor, 3-Ph, 4-wire, 2-Ph, 3-wire & 1-Ph, 2-wire(Note: For detailed specifications please refer attached SBD which forms a part of the tender) 30 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard) 31 Supply and fixing of Mukky clamps for LT Shackle insulators (As per recommended IS/REC Standard) 32 Supplying and fixing of Shackle Insulators (polymer) ( 16KN) (As per recommended IS/REC Standard) 33 Supplying and fixing of Galvanized Nuts and Bolts of sizes. 34 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size.30 mm2 ACSR (Weasel) (As per recommended IS/REC Standard) 35 Cement Bottoming 1:2:4 Mix as per REC Standard 0.5 Cubic Mtr.Per Pole

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Jan-2024 Extension Notice Date 13-01-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 26800.0 /-
Tender Value
INR 13.40 Lakhs /-

BOQ Items

Name of Work:Creation of 250 KVA S/Stn. at Kanuyian Base under JJM (All the items should be as per latest specifications and drawing adopted/Approved by Department)
Sl. No. Item Description
1Erection of 11 KV (HT) Line (Note: For detailed specifications please refer attached SBD which forms a part of the tender)
2Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard)
3G.I Channel/Flat/Angle in shape of Fabricated X-arm Top Bracket, Angle Braced, Clamp etc.
4Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard)
5Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard)
6Supplying and fixing of Galvanized Nuts and Bolts of sizes.
7Supplying and fixing of Galvanized Stay Set with 50X8 mm Stay Clamp, Guy insulator (02 Nos) anchor plate (200x200x6mm) nut bolts, 2 nos. Turn buckles, 1.80 m long 16 mm diameter solid GS Stay rod & 7/3. 15 dia GI Stranded wire complete
8Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing, binding and Jumperig of conductor including joints with PG clamps of required size 30 mm2 ACSR ( Weasel) (As per recommended IS/REC Standard)
9Supply and installation of 11 KV Link Set, 3-phase, 100A (As per recommended IS/REC Standard)
10Earthing complete, G.I Rod 20 mm 2.5 Mtr. Long through G.I Wire
11Cement Bottoming 1:2:4 Mix as per REC Standard 0.5 Cubic Mtr.Per Pole
12Anti Clamping Device
13Erection of 11/0.433 kV Distribution Transformer (Note: For detailed specifications please refer attached SBD which forms a part of the tender)
14Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 250 KVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Copper Wound, oil filled, with LT cable termination box with detachable Copper Gland Plate.(As per recommended IS/REC Standard) (with one year warranty)
15Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard)
16Supply and installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type (As per recommended IS/REC Standard)
17Supply and installation of 11 kV Horn,Gap Fuse Set, 3-phase, 100A (As per recommended IS/REC Standard)
18Supply and installation of 11 kV Link Set, 3-phase, 100A (As per recommended IS/REC Standard)
19Supply and fixing of Un Armoured Single Core PVC Cable 220 mm2 alongwith 12 no. Al. thimble 120 mm2
20Supplying and fixing of Galvanized Nuts and Bolts of sizes.
21Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard)
22Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard)
23Supplying and fixing of Angle Belt 1.5 Mtr for the protection of transformer
24Supply and fixing of LT Distibution fuse set of standard making using clamps/thimbles with Brass Bolts and washers etc. Complete job as per REC standard (Drilling of holes Prohibited).
25Supplying and fixing of Angle Brace for transformer bed
26Supplying and fixing of Cross X-mar 2.8. Mtr
27Cement Bottoming 1:2:4 Mix as per REC Standard 0.5 Cubic Mtr.Per Pole
28Excavation of Earthing Pits of dia = 650 mm and depth= 3000 mm, Supplying and fixing of 3 No. sub station earthingby GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 mm 1 nofor neutral earthing and 25X3 mm 2 nos (for 2 Nos transformer body earth, 2 Nos Pole earth, 1 no. LA Earth and 1 no. GO handle earth). (Note: For LA Earth 1 pipe shall be kept separate) GI Nuts, Bolts and Clamps, refilled with earth enhancement materials and earthing chamber made of brick masonary with RCC Slab Cover. (As per recommended IS/REC Standard)
29Erection of 1kM of LT Line on Conductor, 3-Ph, 4-wire, 2-Ph, 3-wire & 1-Ph, 2-wire (Note: For detailed specifications please refer attached SBD which forms a part of the tender)
30Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard)
31Supply and fixing of Mukky clamps for LT Shackle insulators (As per recommended IS/REC Standard)
32Supplying and fixing of Shackle Insulators (polymer) ( 16KN) (As per recommended IS/REC Standard)
33Supplying and fixing of Galvanized Nuts and Bolts of sizes.
34Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size. 30 mm2 ACSR (Weasel) (As per recommended IS/REC Standard)
35Cement Bottoming 1:2:4 Mix as per REC Standard 0.5 Cubic Mtr.Per Pole
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail