}

Construction Of Road From Nh-31 To Kurobaha Village Road & Nh-31 To Kalbari Namghar Via Kuchiajhar Village Including Routine Maintenance For Four Years Under Mukhya Mantrir Pakipath Nirman Aachani For The Year 2023-24Inbarpeta District, barpeta-Assam

Public Works Roads Department has published Construction Of Road From Nh-31 To Kurobaha Village Road & Nh-31 To Kalbari Namghar Via Kuchiajhar Village Including Routine Maintenance For Four Years Under Mukhya Mantrir Pakipath Nirman Aachani For The Year 2023-24Inbarpeta District. Submission Date for this Tender is 01-01-2024. Road Work Tenders in barpeta Assam. Bidders can get complete Tender details and download the document.




Tender Notice

41283278
Corrigendum : Construction Of Road From Nh-31 To Kurobaha Village Road & Nh-31 To Kalbari Namghar Via Kuchiajhar Village Including Routine Maintenance For Four Years Under Mukhya Mantrir Pakipath Nirman Aachani For The Year 2023-24Inbarpeta District
Open Tender
Indian
Assam
barpeta
01-01-2024

Tender Details

Construction Of Road From Nh-31 To Kurobaha Village Road & Nh-31 To Kalbari Namghar Via Kuchiajhar Village Including Routine Maintenance For Four Years Under Mukhya Mantrir Pakipath Nirman Aachani For The Year 2023-24Inbarpeta District

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Dec-2023 Maint/MMPPNA/2023-24/10 Date 01-01-2024

Key Value

Document Fees
INR 6000 /-
EMD
INR 596000.0 /-
Tender Value
INR 2.98 Crore /-

BOQ Items

Name of Work:Construction of Road fromNH-31 to Kurobaha Village Road & NH-31 to Kalbari Namghar via Kuchiajhar Villageincluding Routine maintenance for Four Years Under Mukhya Mantrir Pakipath Nirman Aachani for the year 2023-24inBarpeta District
Sl. No. Item Description
1Road from NH 31 to Kurobaha village road Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (i) By Manual Means (a) In area of non thorny jungle
2Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (i) Private Land
3Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i) Private Land
4Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material
5Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means
6Providingand laying interlocking concrete block pavement (M40) having thickness 80mm as per echnical specification clause 1504 including carriage. a) including Edge block/Edge restraints
7Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801 600mm equilateral triangle
8Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801 600mm circular
9Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801 800mm x 600mm rectangular
10Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges.The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level.The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube.All M.S. will be stove enameled on both sides.Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour.All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
11HPC Double row Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. I. Ordinary soil (upto 3m depth)
12Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (A)With crushed Stone (II) P.C.C grade M 15 Nominal mix (1:2.5:5)
13Laying concrete cradie bedding with M15 Grade Cement Concrete as Per Clause 1105(i)
14Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (A)With crushed Stone (II) P.C.C grade M 20 Nominal mix (1:2:4)
15Plastering with cement mortar (1:4)15 mm thick on brickwork in substructure as per tech.sp.
16Providing & laying NP3 Culvert on 1st class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation ,protection works, backfilling , concrete and masonary works in head walls and parapets cl.1106 B) 600 mm dia
17Utility Shifting
18Road from NH 31 to Kalbari Namghar via Kuchiajhan village Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (i) By Manual Means (a) In area of non thorny jungle
19Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (i) Private Land
20Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i) Private Land
21Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material
22Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means
23Providingand laying interlocking concrete block pavement (M40) having thickness 80mm as per echnical specification clause 1504 including carriage. a) including Edge block/Edge restraints
24Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801 600mm equilateral triangle
25Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801 600mm circular
26Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801 800mm x 600mm rectangular
27Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges.The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level.The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube.All M.S. will be stove enameled on both sides.Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour.All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
28construction of HPC Earthwork in exavation for foundation of structure as per drawings and technical specification clause 307 including setting out construction of shoring and bracing deleterious matter, dressing of sides and bottom and backfilling with approved material (Rate as per item No. 11.1 of Chapter 11).
29Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109
30Laying (First Class) bedding on well compacted sand, moorum as per Clause 1105 (ii)
31Brick Masonry Work in cement mortar in foundation of Head walls complete exculding pointing and plastering as per drawing and technical specification Clause 1109 A Brick Masonry in 1:4 cement mortar
32Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 1000mm dia
33Plastering with Cement Mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification
343.00 m Box culvert Earth work in excavation for structures as per drawings and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal up to a lead of 50m
35Filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9 (i) Sand filling
36Providing concrete for plain/reinforced concrete in open foundation complete as per drawing and Technical Specification Clause 802, 803,1202& 1203. A. With crushed stone ,I. PCC Grade M10
37Providing concrete for plain/reinforced concrete in open foundation complete as per drawing and Technical Specification Clause 802, 803,1202& 1203. A. With crushed stone ,I. RCC grade M20
38-Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar(From Primary Producer: (SAI / BISCON / THERMAX OR equivalent)) in foundationcomplete as per drawings and technical specification Clauses 1002, & 1202
39Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar(From Primary Producer:(SAI/ BISCON/THERMAX or equivalentin substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
40Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications Clauses 802,804,805,806,807,1202 and 1204. A. With crushed stone, III. RCC GRADE M20 (i) Height up to 5m
41Providing pressure relief pipes 100mm dia in botttom slab of box cell on a filter media base of 500mmx500mm as per drawing and technical specification clause 1205.5.7
42providing and laying of dry rubble flooring complete as per the drawing and technical specification clause 1303.3
43Providing and laying boulder apron for bed protection with stone boulders of minnum size and weight as per table 1300.1 no fragment weighing less then 25 kg laid dry complete as per drawing and technical specifiacations clause 1301
44Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
45Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications Clause 800 & 1206.3 A. With crushed stone :
46Construction of R.C.C. railing of M 30 grade size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500centre-to-centre spacing between vertical posts not to exceed 2000mm, leaving adequate space between vertical posts for expansionas per drawing and technical specifications clauses 800, 900 and 1208.
47Utility Shifting
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail