Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | DIAMONDHARBOUR FERRY GHAT. |
| 2 | EARTH WORKS. |
| 3 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.Depth of excavation not exceeding 1,500 mm. |
| 4 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 5 | BRICK WORKS, CONCRETE WORKS etc. |
| 6 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 7 | Brick work with 1st class bricks in cement mortar (1:6)In foundation and plinth |
| 8 | 60 mm thick interlocking designer concrete paver block M-35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.)(ii) Coloured Decorative |
| 9 | CONCRETE WORKS |
| 10 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]Pakur Variety In foundation. |
| 11 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]In ground floor. |
| 12 | Cement concrete with graded stone ballast (40 mm size excluding shuttering)In ground floor Pakur Variety 1:3:6 proportion. |
| 13 | Cement concrete with graded stone ballast (40 mm size excluding shuttering) 1:4:8 proportion. |
| 14 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work In ground floor. |
| 15 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.For works in foundation, basement and upto roof of ground floor/upto 4 mTor steel/Mild Steel SAIL/ TATA/RINL In foundation. |
| 16 | Above foundation upto roof of ground floor |
| 17 | Supplying, fitting & fixing granite tiles 10mm to 12mm. thick in columns, wall, facia etc. with 15 thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete.[Using cement slurry at back side of tiles@ 4.4 kg/sq.m &white cement slurry for joint filling @ 1.8 kg/sq.m]Area of each slab upto 0.2 Sq.m |
| 18 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.With Sand Cement Mortar (1:4)20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.Ground Floor & wall. |
| 19 | With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.Area of each tile upto 0.09 Sq.m Coloured decorative Ground Floor |
| 20 | STRUCTURAL STEEL WORK |
| 21 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.Ground floor |
| 22 | Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. |
| 23 | CARPENTER\"S WORKS |
| 24 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Siliguri at Ground Floor. |
| 25 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.35 mm thick shutters (single leaf)in ground floor. |
| 26 | Supplying, fitting and fixing M.S. clamps for fixing door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction. (Cost of cement concrete will be paid separately).40 mm. x 6 mm., 200 mm. length. |
| 27 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm. X 58mm. X 1.90mm. |
| 28 | Supplying \"Godrej\" mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete. |
| 29 | Door stopper (Anodised aluminium) |
| 30 | Godrej Hydraulic door closer fitted and fixed complete. Medium type |
| 31 | PLASTERING, POINTING ETC. |
| 32 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/stagingwhere necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement mortar.20 mm thick(External Surface) Ground floor. |
| 33 | With 1:4 cement mortar 15 mm thick(Internal Surface) wall Ground floor. |
| 34 | With 1:3 cement mortar 10 mm thick(Internal Surface) ceiling Ground floor. |
| 35 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.NOTE : Cement 0.152 cu.m. per 100 sq.m. |
| 36 | Labour for Chipping of concrete surface before taking up Plastering work. |
| 37 | FALSE CEILING |
| 38 | P.V.C- False Ceiling :Providing False Ceiling made with framework of steel tube of 40mm x 20mm of not less than 18 gauge,the long and cross section will be welded with each other 1000mm to 1200mm apart the entire framework will be fixed in wall using rawlplug or gutties or screws etc. and suspended from ceiling with M.S flat 19mmx3mm as necessary,the entire frame will be painted with red oxide.PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm) of approved quality and colour will be fixed on the frame so that the entire framework will not be visible from below P.V.C Section will be fixed with the frame with the help of self tapping steel screws including all materials and labour charges including fitting,fixing the same and hoisting including mending the damages in all respect and cost of paint as required as per direction of Engineer in- Charge .In ground floor. |
| 39 | Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP)(b) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating) |
| 40 | Supplying, Aluminium Grill with F channel frame of approved make and brand having ultimate tensile strength of 19 Kg/Sq.m. and modulus of elasticity 7000 kg/ sq.m., with 15 micron anodised fitted & fixed with necessary screws etc. complete as per direction of Engineer-in-charge.Grill made with 10 mm wide and 5.2 mm thick aluminium sheet having expansion width of 66.00 mm and weight not less than 3.26 Kg/Sq.m. |
| 41 | WHITE WASH, COLOUR WASH, DISTEMPER |
| 42 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.One Coat Water based interior grade Acrylic Primer Ground Floor. |
| 43 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finishacrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. One Coat External surfaceGround Floor. |
| 44 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost ofprimer.Premium 100% Acrylic Emulsion (Two Coat) External surface Ground Floor. |
| 45 | PAINTING, VARNISHING ETC. |
| 46 | Priming one coaton steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 47 | Priming one coat on timber or plasteredsurface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 48 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: On timber or plastered surface With super gloss (hi-gloss)Two coats (with any shade except white). |
| 49 | On steel or other metal surface With super gloss (hi-gloss) Two coats (with any shade except white) |
| 50 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) (Two coats) Standard Quality |
| 51 | Pontoon & Gangway Deck Painting |
| 52 | Painting with best quality anti skid paint of approved make and brand including smoothening surface by sand papering etc. including using of approved primer etc. on the surface, if necessary. On steel or other metal surface: Two coats |
| 53 | The Pontoon shall be cleaned mechanically / manuallyinternal & external area prior to apply paints the pontoon internal & external hull area deck fittings shall be painted with 2-coats Tuff coat Red oxide Zinc chromate & final 2-coat as per painting schedule under instruction & satisfaction of Engineer-in-charge.(Blue & White coloured paint only) |
| 54 | DRAIN, DOWN PIPES |
| 55 | Supplying, fitting , fixingC.I Grating (Heavy Type) Above 100 mm and upto 150 mm Square or round. |
| 56 | Stainless Steel railing: |
| 57 | Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle Brushed/Mat finish, complete as per direction of the Engineer-in-charge.Weight of Strainless Steel railing per metre 6.5 Kg (approx). |
| 58 | Galvanised iron sheets valley gutter with perimeter not less than 750 mm with 225 mm lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley gutter made of 0.63 mm. thick sheets. (300mm End lapping) |
| 59 | Grouting the foundation bolt (by HILTI method) for yoke and roller base plate from yoke staging platform as per the direction & instruction to the satisfaction of Engineer-in-charge |
| 60 | HORTICULTURE |
| 61 | Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment) |
| 62 | Supplying and fixing grasses tiles of grass Maxican Carpet/Selection No. 1 Healthy & fresh grasses (size 1\"x1\" or bigger) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from wees and fit for mowing including supplying good earth as required by Engineer-in-charge. (Rate includes supply of labour, tools & plants including materials) |
| 63 | Supplying and Planting of different plant / trees (Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift, carriage, handling, manuring, applying presticide and fertilizer etc.i) Furcaria veriegated 10-12 leaves in height 20-30cm inearthen pots of size 25cm. |
| 64 | ii) Rangon chineese of size not less than 20cm |
| 65 | China palm of leaves 4-5 in earthen pots size 25cm |
| 66 | Ficus blakii (F. Vivicon) well branched (Bushy) of height 120cm - 135 cm in earthen pot of size 30cm. |
| 67 | Ficus elastica Decora ( Rubber plant ) of height 90cm-60cm in each earthen pot of size 25cm. |
| 68 | Adenium obesum of height 90cm-60cm in earthen pots of size 25cm. |
| 69 | Bougainvillea (name variety, bushy plants, full bloom) of height 90cm-60cm in cement pots of size 30cm. |
| 70 | Areca Palm 4 - 5 suckers of height 90 cm to 105 cm in earthen pots of size 25 cm. |
| 71 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)With carried earth arranged by the contractor within a radius exceeding 5 km. but not exceeding 10 km. including cost of carried earth. |
| 72 | Supply, fitting & fixing of different items maintaining Standard Operating Procedure guideline. |
| 73 | Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). iv) 80 mm x 60 mm rectangular |
| 74 | Installation of Fire Bucket 9 L(filled with sand or water) to prevent or extinguish fire. |
| 75 | Installation of Fire Extinguisher (6 Kg) to prevent or extinguish fire. |
| 76 | Installation of buoyant device (Life Buoy) to provide Buoyancy and prevent drowning (Weight-65Kg). |
| 77 | Installation of Display Board for S.O.P. (Standard Operating Procedure) to maintain the routine operation. |
| 78 | Supplying, Stainless Steel Swing Dust Bin, Garbage Bin Trash can with Removable lid Round Shape Silver Color (Set of 1) Slim and Fingerprint-Proof Finish Diameter x Height- (12X28-60Liter) of approved make complete. |
| 79 | ELECTRICAL WORK |
| 80 | Supply Fitting & FixingCeling Fan and making necessary connections as required. |
| 81 | Supply Fitting & Fixing 70 Watt LED Flood Light and making necessary connections as required. |
| 82 | Supply Fitting & Fixing20 Watt LED Tube Light and making necessary connections as required. |
| 83 | Supplying fitting fixing Solar street light with 80 mm G.I. Pipe (4.0 m long) and necessary fittings including cost of all materials , light , battery and other equipment and labour charges for fitting as per direction of Engineer-in-charge(LED 1 street light PV Module :35W panel solar charging full sunlight : 8 Hrs Battery capacity : 5200 m An Battery nominal voltage :14.8v). |
| 84 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.32A DP MCB |
| 85 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.32A SP MCB |
| 86 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 mtrs long and 1 x 4 SWG GI (Hot Dip) wire (4 mtrs long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers including supply and fixing of 15 mm dia GI pipe protection (1 mtrs long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mtrs below the ground level and restoring surface duly rammed as below.By ISI-Medium GI pipe |
| 87 | Treatment of soil by using salt and charcoal or coke for plate electrode (for soft soil/morrum soil). |
| 88 | Providing masonry enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work (1:6) of 25 cm width duly plastered with cement mortar (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 Nos 12 mm dia holes on the GI pipe. |
| 89 | Connecting the equipments to earth bus bar including supply and fixing of GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc, as required and mending good the damages.6 SWG |
| 90 | Connecting the equipments to earth bus bar including supply and fixing of GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc, as required and mending good the damages.8 SWG |
| 91 | LT Cable and AccessoriesSupply of XLPE/PVC insulated, Armoured/Unarmoured/Flexible, Aluminium conductor( all rates are excluding of vat). 3.5C x 70 Sq.mm / A2XFY |
| 92 | 4C x 10 Sq.mm Copper Armour Cable (for Ductable AC and DB) |
| 93 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 4 core 10 to 16 sqmm |
| 94 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 3.5 core upto 70 sqmm |
| 95 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :4 core 25 sqmm cable |
| 96 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :3.5 core 70 sqmm cable |
| 97 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 4 Module |
| 98 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.12 Module(2 Row) |
| 99 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required. |
| 100 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc |
| 101 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. |
| 102 | Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 103 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. Average run 5 mtr |
| 104 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. On Board |
| 105 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. Average run 1.5 mtr |
| 106 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. Average run 4.5 mtr |
| 107 | Supply, installation, testing & commissioning of heavy duty exhaust fan with gravity louvers and gaurds etc. complete in all respect as per technical specification, drawings & as required at site.300 mm dia , 1400 rpm 1 phase. |
| 108 | Supply, installation, testing & commissioning of 400mm wall fancomplete in all respect as per technical specification, drawings & as required at site. |
| 109 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 100 mm x 100 mm x 65 mm deep |
| 110 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 150 mm x 100 mm x 65 mm deep |
| 111 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 200 mm x 150 mm x 65 mm deep |
| 112 | Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required. 200 mm x 150 mm x 65 mm deep |
| 113 | Supply, installation, assembling, testing and commissioning of the following Light Fixtures with complete accessories, control gears, civil works complete in all respect as per technical specifications and drawings.The quoted rate shall be inclusive of Lamps,fixtures and accessories including all necessary supports, brackets, down rods and painting etc. as required.Supply of 10 W/ 15W LED Down light fittings with6.5K (Philips/ Syska or equivalent make) |
| 114 | RAICHAK FERRY GHAT. |
| 115 | EARTH WORKS. |
| 116 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.Depth of excavation not exceeding 1,500 mm. |
| 117 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 118 | BRICK WORKS, CONCRETE WORKS etc. |
| 119 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 120 | Brick work with 1st class bricks in cement mortar (1:6)In foundation and plinth |
| 121 | 60 mm thick interlocking designer concrete paver block M-35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.)(ii) Coloured Decorative |
| 122 | CONCRETE WORKS |
| 123 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]Pakur Variety In foundation. |
| 124 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]In ground floor. |
| 125 | Cement concrete with graded stone ballast (40 mm size excluding shuttering)In ground floor Pakur Variety 1:3:6 proportion. |
| 126 | Cement concrete with graded stone ballast (40 mm size excluding shuttering) 1:4:8 proportion. |
| 127 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work In ground floor. |
| 128 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.For works in foundation, basement and upto roof of ground floor/upto 4 mTor steel/Mild Steel SAIL/ TATA/RINL In foundation. |
| 129 | Above foundation upto roof of ground floor |
| 130 | Supplying, fitting & fixing granite tiles 10mm to 12mm. thick in columns, wall, facia etc. with 15 thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete.[Using cement slurry at back side of tiles@ 4.4 kg/sq.m &white cement slurry for joint filling @ 1.8 kg/sq.m]Area of each slab upto 0.2 Sq.m |
| 131 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.With Sand Cement Mortar (1:4)20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.Ground Floor & wall. |
| 132 | With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.Area of each tile upto 0.09 Sq.m Coloured decorative Ground Floor |
| 133 | STRUCTURAL STEEL WORK |
| 134 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.Ground floor |
| 135 | Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. |
| 136 | CARPENTER\"S WORKS |
| 137 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Siliguri at Ground Floor. |
| 138 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.35 mm thick shutters (single leaf)in ground floor. |
| 139 | Supplying, fitting and fixing M.S. clamps for fixing door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction. (Cost of cement concrete will be paid separately).40 mm. x 6 mm., 200 mm. length. |
| 140 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm. X 58mm. X 1.90mm. |
| 141 | Supplying \"Godrej\" mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete. |
| 142 | Door stopper (Anodised aluminium) |
| 143 | Godrej Hydraulic door closer fitted and fixed complete. Medium type |
| 144 | PLASTERING, POINTING ETC. |
| 145 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/stagingwhere necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement mortar.20 mm thick(External Surface) Ground floor. |
| 146 | With 1:4 cement mortar 15 mm thick(Internal Surface) wall Ground floor. |
| 147 | With 1:3 cement mortar 10 mm thick(Internal Surface) ceiling Ground floor. |
| 148 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.NOTE : Cement 0.152 cu.m. per 100 sq.m. |
| 149 | Labour for Chipping of concrete surface before taking up Plastering work. |
| 150 | FALSE CEILING |
| 151 | P.V.C- False Ceiling :Providing False Ceiling made with framework of steel tube of 40mm x 20mm of not less than 18 gauge,the long and cross section will be welded with each other 1000mm to 1200mm apart the entire framework will be fixed in wall using rawlplug or gutties or screws etc. and suspended from ceiling with M.S flat 19mmx3mm as necessary,the entire frame will be painted with red oxide.PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm) of approved quality and colour will be fixed on the frame so that the entire framework will not be visible from below P.V.C Section will be fixed with the frame with the help of self tapping steel screws including all materials and labour charges including fitting,fixing the same and hoisting including mending the damages in all respect and cost of paint as required as per direction of Engineer in- Charge .In ground floor. |
| 152 | Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP)(b) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating) |
| 153 | Supplying, Aluminium Grill with F channel frame of approved make and brand having ultimate tensile strength of 19 Kg/Sq.m. and modulus of elasticity 7000 kg/ sq.m., with 15 micron anodised fitted & fixed with necessary screws etc. complete as per direction of Engineer-in-charge.Grill made with 10 mm wide and 5.2 mm thick aluminium sheet having expansion width of 66.00 mm and weight not less than 3.26 Kg/Sq.m. |
| 154 | WHITE WASH, COLOUR WASH, DISTEMPER |
| 155 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.One Coat Water based interior grade Acrylic Primer Ground Floor. |
| 156 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finishacrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. One Coat External surfaceGround Floor. |
| 157 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost ofprimer.Premium 100% Acrylic Emulsion (Two Coat) External surface Ground Floor. |
| 158 | PAINTING, VARNISHING ETC. |
| 159 | Priming one coaton steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 160 | Priming one coat on timber or plasteredsurface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 161 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: On timber or plastered surface With super gloss (hi-gloss)Two coats (with any shade except white). |
| 162 | On steel or other metal surface With super gloss (hi-gloss) Two coats (with any shade except white) |
| 163 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) (Two coats) Standard Quality |
| 164 | Pontoon & Gangway Deck Painting |
| 165 | Painting with best quality anti skid paint of approved make and brand including smoothening surface by sand papering etc. including using of approved primer etc. on the surface, if necessary. On steel or other metal surface: Two coats |
| 166 | The Pontoon shall be cleaned mechanically / manuallyinternal & external area prior to apply paints the pontoon internal & external hull area deck fittings shall be painted with 2-coats Tuff coat Red oxide Zinc chromate & final 2-coat as per painting schedule under instruction & satisfaction of Engineer-in-charge.(Blue & White coloured paint only) |
| 167 | DRAIN, DOWN PIPES |
| 168 | Supplying, fitting , fixingC.I Grating (Heavy Type) Above 100 mm and upto 150 mm Square or round. |
| 169 | Stainless Steel railing: |
| 170 | Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle Brushed/Mat finish, complete as per direction of the Engineer-in-charge.Weight of Strainless Steel railing per metre 6.5 Kg (approx). |
| 171 | Galvanised iron sheets valley gutter with perimeter not less than 750 mm with 225 mm lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley gutter made of 0.63 mm. thick sheets. (300mm End lapping) |
| 172 | Grouting the foundation bolt (by HILTI method) for yoke and roller base plate from yoke staging platform as per the direction & instruction to the satisfaction of Engineer-in-charge |
| 173 | HORTICULTURE |
| 174 | Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment) |
| 175 | Supplying and fixing grasses tiles of grass Maxican Carpet/Selection No. 1 Healthy & fresh grasses (size 1\"x1\" or bigger) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from wees and fit for mowing including supplying good earth as required by Engineer-in-charge. (Rate includes supply of labour, tools & plants including materials) |
| 176 | Supplying and Planting of different plant / trees (Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift, carriage, handling, manuring, applying presticide and fertilizer etc.i) Furcaria veriegated 10-12 leaves in height 20-30cm inearthen pots of size 25cm. |
| 177 | ii) Rangon chineese of size not less than 20cm |
| 178 | China palm of leaves 4-5 in earthen pots size 25cm |
| 179 | Ficus blakii (F. Vivicon) well branched (Bushy) of height 120cm - 135 cm in earthen pot of size 30cm. |
| 180 | Ficus elastica Decora ( Rubber plant ) of height 90cm-60cm in each earthen pot of size 25cm. |
| 181 | Adenium obesum of height 90cm-60cm in earthen pots of size 25cm. |
| 182 | Bougainvillea (name variety, bushy plants, full bloom) of height 90cm-60cm in cement pots of size 30cm. |
| 183 | Areca Palm 4 - 5 suckers of height 90 cm to 105 cm in earthen pots of size 25 cm. |
| 184 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)With carried earth arranged by the contractor within a radius exceeding 5 km. but not exceeding 10 km. including cost of carried earth. |
| 185 | Supply, fitting & fixing of different items maintaining Standard Operating Procedure guideline. |
| 186 | Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). iv) 80 mm x 60 mm rectangular |
| 187 | Installation of Fire Bucket 9 L(filled with sand or water) to prevent or extinguish fire. |
| 188 | Installation of Fire Extinguisher (6 Kg) to prevent or extinguish fire. |
| 189 | Installation of buoyant device (Life Buoy) to provide Buoyancy and prevent drowning (Weight-65Kg). |
| 190 | Installation of Display Board for S.O.P. (Standard Operating Procedure) to maintain the routine operation. |
| 191 | Supplying, Stainless Steel Swing Dust Bin, Garbage Bin Trash can with Removable lid Round Shape Silver Color (Set of 1) Slim and Fingerprint-Proof Finish Diameter x Height- (12X28-60Liter) of approved make complete. |
| 192 | ELECTRICAL WORK |
| 193 | Supply Fitting & FixingCeling Fan and making necessary connections as required. |
| 194 | Supply Fitting & Fixing 70 Watt LED Flood Light and making necessary connections as required. |
| 195 | Supply Fitting & Fixing20 Watt LED Tube Light and making necessary connections as required. |
| 196 | Supplying fitting fixing Solar street light with 80 mm G.I. Pipe (4.0 m long) and necessary fittings including cost of all materials , light , battery and other equipment and labour charges for fitting as per direction of Engineer-in-charge(LED 1 street light PV Module :35W panel solar charging full sunlight : 8 Hrs Battery capacity : 5200 m An Battery nominal voltage :14.8v). |
| 197 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.32A DP MCB |
| 198 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.32A SP MCB |
| 199 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 mtrs long and 1 x 4 SWG GI (Hot Dip) wire (4 mtrs long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers including supply and fixing of 15 mm dia GI pipe protection (1 mtrs long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mtrs below the ground level and restoring surface duly rammed as below.By ISI-Medium GI pipe |
| 200 | Treatment of soil by using salt and charcoal or coke for plate electrode (for soft soil/morrum soil). |
| 201 | Providing masonry enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work (1:6) of 25 cm width duly plastered with cement mortar (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 Nos 12 mm dia holes on the GI pipe. |
| 202 | Connecting the equipments to earth bus bar including supply and fixing of GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc, as required and mending good the damages.6 SWG |
| 203 | Connecting the equipments to earth bus bar including supply and fixing of GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc, as required and mending good the damages.8 SWG |
| 204 | LT Cable and AccessoriesSupply of XLPE/PVC insulated, Armoured/Unarmoured/Flexible, Aluminium conductor( all rates are excluding of vat). 3.5C x 70 Sq.mm / A2XFY |
| 205 | 4C x 10 Sq.mm Copper Armour Cable (for Ductable AC and DB) |
| 206 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 4 core 10 to 16 sqmm |
| 207 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 3.5 core upto 70 sqmm |
| 208 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :4 core 25 sqmm cable |
| 209 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :3.5 core 70 sqmm cable |
| 210 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 4 Module |
| 211 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.12 Module(2 Row) |
| 212 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required. |
| 213 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc |
| 214 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. |
| 215 | Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 216 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. Average run 5 mtr |
| 217 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. On Board |
| 218 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. Average run 1.5 mtr |
| 219 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. Average run 4.5 mtr |
| 220 | Supply, installation, testing & commissioning of heavy duty exhaust fan with gravity louvers and gaurds etc. complete in all respect as per technical specification, drawings & as required at site.300 mm dia , 1400 rpm 1 phase. |
| 221 | Supply, installation, testing & commissioning of 400mm wall fancomplete in all respect as per technical specification, drawings & as required at site. |
| 222 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 100 mm x 100 mm x 65 mm deep |
| 223 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 150 mm x 100 mm x 65 mm deep |
| 224 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 200 mm x 150 mm x 65 mm deep |
| 225 | Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required. 200 mm x 150 mm x 65 mm deep |
| 226 | Supply, installation, assembling, testing and commissioning of the following Light Fixtures with complete accessories, control gears, civil works complete in all respect as per technical specifications and drawings.The quoted rate shall be inclusive of Lamps,fixtures and accessories including all necessary supports, brackets, down rods and painting etc. as required.Supply of 10 W/ 15W LED Down light fittings with6.5K (Philips/ Syska or equivalent make) |
| 227 | NOORPUR FERRY GHAT. |
| 228 | EARTH WORKS. |
| 229 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.Depth of excavation not exceeding 1,500 mm. |
| 230 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 231 | BRICK WORKS, CONCRETE WORKS etc. |
| 232 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 233 | Brick work with 1st class bricks in cement mortar (1:6)In foundation and plinth |
| 234 | 60 mm thick interlocking designer concrete paver block M-35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.)(ii) Coloured Decorative |
| 235 | CONCRETE WORKS |
| 236 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]Pakur Variety In foundation. |
| 237 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]In ground floor. |
| 238 | Cement concrete with graded stone ballast (40 mm size excluding shuttering)In ground floor Pakur Variety 1:3:6 proportion. |
| 239 | Cement concrete with graded stone ballast (40 mm size excluding shuttering) 1:4:8 proportion. |
| 240 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work In ground floor. |
| 241 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.For works in foundation, basement and upto roof of ground floor/upto 4 mTor steel/Mild Steel SAIL/ TATA/RINL In foundation. |
| 242 | Above foundation upto roof of ground floor |
| 243 | Supplying, fitting & fixing granite tiles 10mm to 12mm. thick in columns, wall, facia etc. with 15 thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete.[Using cement slurry at back side of tiles@ 4.4 kg/sq.m &white cement slurry for joint filling @ 1.8 kg/sq.m]Area of each slab upto 0.2 Sq.m |
| 244 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.With Sand Cement Mortar (1:4)20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.Ground Floor & wall. |
| 245 | With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.Area of each tile upto 0.09 Sq.m Coloured decorative Ground Floor |
| 246 | STRUCTURAL STEEL WORK |
| 247 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.Ground floor |
| 248 | Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. |
| 249 | CARPENTER\"S WORKS |
| 250 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Siliguri at Ground Floor. |
| 251 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.35 mm thick shutters (single leaf)in ground floor. |
| 252 | Supplying, fitting and fixing M.S. clamps for fixing door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction. (Cost of cement concrete will be paid separately).40 mm. x 6 mm., 200 mm. length. |
| 253 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm. X 58mm. X 1.90mm. |
| 254 | Supplying \"Godrej\" mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete. |
| 255 | Door stopper (Anodised aluminium) |
| 256 | Godrej Hydraulic door closer fitted and fixed complete. Medium type |
| 257 | PLASTERING, POINTING ETC. |
| 258 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/stagingwhere necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement mortar.20 mm thick(External Surface) Ground floor. |
| 259 | With 1:4 cement mortar 15 mm thick(Internal Surface) wall Ground floor. |
| 260 | With 1:3 cement mortar 10 mm thick(Internal Surface) ceiling Ground floor. |
| 261 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.NOTE : Cement 0.152 cu.m. per 100 sq.m. |
| 262 | Labour for Chipping of concrete surface before taking up Plastering work. |
| 263 | FALSE CEILING |
| 264 | P.V.C- False Ceiling :Providing False Ceiling made with framework of steel tube of 40mm x 20mm of not less than 18 gauge,the long and cross section will be welded with each other 1000mm to 1200mm apart the entire framework will be fixed in wall using rawlplug or gutties or screws etc. and suspended from ceiling with M.S flat 19mmx3mm as necessary,the entire frame will be painted with red oxide.PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm) of approved quality and colour will be fixed on the frame so that the entire framework will not be visible from below P.V.C Section will be fixed with the frame with the help of self tapping steel screws including all materials and labour charges including fitting,fixing the same and hoisting including mending the damages in all respect and cost of paint as required as per direction of Engineer in- Charge .In ground floor. |
| 265 | Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP)(b) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating) |
| 266 | Supplying, Aluminium Grill with F channel frame of approved make and brand having ultimate tensile strength of 19 Kg/Sq.m. and modulus of elasticity 7000 kg/ sq.m., with 15 micron anodised fitted & fixed with necessary screws etc. complete as per direction of Engineer-in-charge.Grill made with 10 mm wide and 5.2 mm thick aluminium sheet having expansion width of 66.00 mm and weight not less than 3.26 Kg/Sq.m. |
| 267 | WHITE WASH, COLOUR WASH, DISTEMPER |
| 268 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.One Coat Water based interior grade Acrylic Primer Ground Floor. |
| 269 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finishacrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. One Coat External surfaceGround Floor. |
| 270 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost ofprimer.Premium 100% Acrylic Emulsion (Two Coat) External surface Ground Floor. |
| 271 | PAINTING, VARNISHING ETC. |
| 272 | Priming one coaton steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 273 | Priming one coat on timber or plasteredsurface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 274 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: On timber or plastered surface With super gloss (hi-gloss)Two coats (with any shade except white). |
| 275 | On steel or other metal surface With super gloss (hi-gloss) Two coats (with any shade except white) |
| 276 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) (Two coats) Standard Quality |
| 277 | Pontoon & Gangway Deck Painting |
| 278 | Painting with best quality anti skid paint of approved make and brand including smoothening surface by sand papering etc. including using of approved primer etc. on the surface, if necessary. On steel or other metal surface: Two coats |
| 279 | The Pontoon shall be cleaned mechanically / manuallyinternal & external area prior to apply paints the pontoon internal & external hull area deck fittings shall be painted with 2-coats Tuff coat Red oxide Zinc chromate & final 2-coat as per painting schedule under instruction & satisfaction of Engineer-in-charge.(Blue & White coloured paint only) |
| 280 | DRAIN, DOWN PIPES |
| 281 | Supplying, fitting , fixingC.I Grating (Heavy Type) Above 100 mm and upto 150 mm Square or round. |
| 282 | Stainless Steel railing: |
| 283 | Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle Brushed/Mat finish, complete as per direction of the Engineer-in-charge.Weight of Strainless Steel railing per metre 6.5 Kg (approx). |
| 284 | Galvanised iron sheets valley gutter with perimeter not less than 750 mm with 225 mm lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley gutter made of 0.63 mm. thick sheets. (300mm End lapping) |
| 285 | Grouting the foundation bolt (by HILTI method) for yoke and roller base plate from yoke staging platform as per the direction & instruction to the satisfaction of Engineer-in-charge |
| 286 | HORTICULTURE |
| 287 | Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment) |
| 288 | Supplying and fixing grasses tiles of grass Maxican Carpet/Selection No. 1 Healthy & fresh grasses (size 1\"x1\" or bigger) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from wees and fit for mowing including supplying good earth as required by Engineer-in-charge. (Rate includes supply of labour, tools & plants including materials) |
| 289 | Supplying and Planting of different plant / trees (Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift, carriage, handling, manuring, applying presticide and fertilizer etc.i) Furcaria veriegated 10-12 leaves in height 20-30cm inearthen pots of size 25cm. |
| 290 | ii) Rangon chineese of size not less than 20cm |
| 291 | China palm of leaves 4-5 in earthen pots size 25cm |
| 292 | Ficus blakii (F. Vivicon) well branched (Bushy) of height 120cm - 135 cm in earthen pot of size 30cm. |
| 293 | Ficus elastica Decora ( Rubber plant ) of height 90cm-60cm in each earthen pot of size 25cm. |
| 294 | Adenium obesum of height 90cm-60cm in earthen pots of size 25cm. |
| 295 | Bougainvillea (name variety, bushy plants, full bloom) of height 90cm-60cm in cement pots of size 30cm. |
| 296 | Areca Palm 4 - 5 suckers of height 90 cm to 105 cm in earthen pots of size 25 cm. |
| 297 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)With carried earth arranged by the contractor within a radius exceeding 5 km. but not exceeding 10 km. including cost of carried earth. |
| 298 | Supply, fitting & fixing of different items maintaining Standard Operating Procedure guideline. |
| 299 | Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). iv) 80 mm x 60 mm rectangular |
| 300 | Installation of Fire Bucket 9 L(filled with sand or water) to prevent or extinguish fire. |
| 301 | Installation of Fire Extinguisher (6 Kg) to prevent or extinguish fire. |
| 302 | Installation of buoyant device (Life Buoy) to provide Buoyancy and prevent drowning (Weight-65Kg). |
| 303 | Installation of Display Board for S.O.P. (Standard Operating Procedure) to maintain the routine operation. |
| 304 | Supplying, Stainless Steel Swing Dust Bin, Garbage Bin Trash can with Removable lid Round Shape Silver Color (Set of 1) Slim and Fingerprint-Proof Finish Diameter x Height- (12X28-60Liter) of approved make complete. |
| 305 | ELECTRICAL WORK |
| 306 | Supply Fitting & FixingCeling Fan and making necessary connections as required. |
| 307 | Supply Fitting & Fixing 70 Watt LED Flood Light and making necessary connections as required. |
| 308 | Supply Fitting & Fixing20 Watt LED Tube Light and making necessary connections as required. |
| 309 | Supplying fitting fixing Solar street light with 80 mm G.I. Pipe (4.0 m long) and necessary fittings including cost of all materials , light , battery and other equipment and labour charges for fitting as per direction of Engineer-in-charge(LED 1 street light PV Module :35W panel solar charging full sunlight : 8 Hrs Battery capacity : 5200 m An Battery nominal voltage :14.8v). |
| 310 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.32A DP MCB |
| 311 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.32A SP MCB |
| 312 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 mtrs long and 1 x 4 SWG GI (Hot Dip) wire (4 mtrs long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers including supply and fixing of 15 mm dia GI pipe protection (1 mtrs long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mtrs below the ground level and restoring surface duly rammed as below.By ISI-Medium GI pipe |
| 313 | Treatment of soil by using salt and charcoal or coke for plate electrode (for soft soil/morrum soil). |
| 314 | Providing masonry enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work (1:6) of 25 cm width duly plastered with cement mortar (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 Nos 12 mm dia holes on the GI pipe. |
| 315 | Connecting the equipments to earth bus bar including supply and fixing of GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc, as required and mending good the damages.6 SWG |
| 316 | Connecting the equipments to earth bus bar including supply and fixing of GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc, as required and mending good the damages.8 SWG |
| 317 | LT Cable and AccessoriesSupply of XLPE/PVC insulated, Armoured/Unarmoured/Flexible, Aluminium conductor( all rates are excluding of vat). 3.5C x 70 Sq.mm / A2XFY |
| 318 | 4C x 10 Sq.mm Copper Armour Cable (for Ductable AC and DB) |
| 319 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 4 core 10 to 16 sqmm |
| 320 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 3.5 core upto 70 sqmm |
| 321 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :4 core 25 sqmm cable |
| 322 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :3.5 core 70 sqmm cable |
| 323 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 4 Module |
| 324 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.12 Module(2 Row) |
| 325 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required. |
| 326 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc |
| 327 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. |
| 328 | Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 329 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. Average run 5 mtr |
| 330 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. On Board |
| 331 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. Average run 1.5 mtr |
| 332 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. Average run 4.5 mtr |
| 333 | Supply, installation, testing & commissioning of heavy duty exhaust fan with gravity louvers and gaurds etc. complete in all respect as per technical specification, drawings & as required at site.300 mm dia , 1400 rpm 1 phase. |
| 334 | Supply, installation, testing & commissioning of 400mm wall fancomplete in all respect as per technical specification, drawings & as required at site. |
| 335 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 100 mm x 100 mm x 65 mm deep |
| 336 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 150 mm x 100 mm x 65 mm deep |
| 337 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 200 mm x 150 mm x 65 mm deep |
| 338 | Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required. 200 mm x 150 mm x 65 mm deep |
| 339 | Supply, installation, assembling, testing and commissioning of the following Light Fixtures with complete accessories, control gears, civil works complete in all respect as per technical specifications and drawings.The quoted rate shall be inclusive of Lamps,fixtures and accessories including all necessary supports, brackets, down rods and painting etc. as required.Supply of 10 W/ 15W LED Down light fittings with6.5K (Philips/ Syska or equivalent make) |
| 340 | KUKRAHATI FERRY GHAT. |
| 341 | EARTH WORKS. |
| 342 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.Depth of excavation not exceeding 1,500 mm. |
| 343 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)With earth obtained from excavation of foundation. |
| 344 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 345 | BRICK WORKS, CONCRETE WORKS etc. |
| 346 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 347 | Brick work with 1st class bricks in cement mortar (1:6)In foundation and plinth |
| 348 | 60 mm thick interlocking designer concrete paver block M-35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.)(ii) Coloured Decorative |
| 349 | CONCRETE WORKS |
| 350 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]Pakur Variety In foundation. |
| 351 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]In ground floor. |
| 352 | Cement concrete with graded stone ballast (40 mm size excluding shuttering)In ground floor Pakur Variety 1:3:6 proportion. |
| 353 | Cement concrete with graded stone ballast (40 mm size excluding shuttering) 1:4:8 proportion. |
| 354 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work In ground floor. |
| 355 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.For works in foundation, basement and upto roof of ground floor/upto 4 mTor steel/Mild Steel SAIL/ TATA/RINL In foundation. |
| 356 | Above foundation upto roof of ground floor |
| 357 | Supplying, fitting & fixing granite tiles 10mm to 12mm. thick in columns, wall, facia etc. with 15 thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete.[Using cement slurry at back side of tiles@ 4.4 kg/sq.m &white cement slurry for joint filling @ 1.8 kg/sq.m]Area of each slab upto 0.2 Sq.m |
| 358 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.With Sand Cement Mortar (1:4)20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.Ground Floor & wall. |
| 359 | With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.Area of each tile upto 0.09 Sq.m Coloured decorative Ground Floor |
| 360 | STRUCTURAL STEEL WORK |
| 361 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.Ground floor |
| 362 | Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. |
| 363 | CARPENTER\"S WORKS |
| 364 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Siliguri at Ground Floor. |
| 365 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.35 mm thick shutters (single leaf)in ground floor. |
| 366 | Supplying, fitting and fixing M.S. clamps for fixing door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction. (Cost of cement concrete will be paid separately).40 mm. x 6 mm., 200 mm. length. |
| 367 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm. X 58mm. X 1.90mm. |
| 368 | Supplying \"Godrej\" mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete. |
| 369 | Door stopper (Anodised aluminium) |
| 370 | Godrej Hydraulic door closer fitted and fixed complete. Medium type |
| 371 | PLASTERING, POINTING ETC. |
| 372 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/stagingwhere necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement mortar.20 mm thick(External Surface) Ground floor. |
| 373 | With 1:4 cement mortar 15 mm thick(Internal Surface) wall Ground floor. |
| 374 | With 1:3 cement mortar 10 mm thick(Internal Surface) ceiling Ground floor. |
| 375 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.NOTE : Cement 0.152 cu.m. per 100 sq.m. |
| 376 | Labour for Chipping of concrete surface before taking up Plastering work. |
| 377 | FALSE CEILING |
| 378 | P.V.C- False Ceiling :Providing False Ceiling made with framework of steel tube of 40mm x 20mm of not less than 18 gauge,the long and cross section will be welded with each other 1000mm to 1200mm apart the entire framework will be fixed in wall using rawlplug or gutties or screws etc. and suspended from ceiling with M.S flat 19mmx3mm as necessary,the entire frame will be painted with red oxide.PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm) of approved quality and colour will be fixed on the frame so that the entire framework will not be visible from below P.V.C Section will be fixed with the frame with the help of self tapping steel screws including all materials and labour charges including fitting,fixing the same and hoisting including mending the damages in all respect and cost of paint as required as per direction of Engineer in- Charge .In ground floor. |
| 379 | Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP)(b) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating) |
| 380 | Supplying, Aluminium Grill with F channel frame of approved make and brand having ultimate tensile strength of 19 Kg/Sq.m. and modulus of elasticity 7000 kg/ sq.m., with 15 micron anodised fitted & fixed with necessary screws etc. complete as per direction of Engineer-in-charge.Grill made with 10 mm wide and 5.2 mm thick aluminium sheet having expansion width of 66.00 mm and weight not less than 3.26 Kg/Sq.m. |
| 381 | WHITE WASH, COLOUR WASH, DISTEMPER |
| 382 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.One Coat Water based interior grade Acrylic Primer Ground Floor. |
| 383 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finishacrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. One Coat External surfaceGround Floor. |
| 384 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost ofprimer.Premium 100% Acrylic Emulsion (Two Coat) External surface Ground Floor. |
| 385 | PAINTING, VARNISHING ETC. |
| 386 | Priming one coaton steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 387 | Priming one coat on timber or plasteredsurface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 388 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: On timber or plastered surface With super gloss (hi-gloss)Two coats (with any shade except white). |
| 389 | On steel or other metal surface With super gloss (hi-gloss) Two coats (with any shade except white) |
| 390 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) (Two coats) Standard Quality |
| 391 | Pontoon & Gangway Deck Painting |
| 392 | Painting with best quality anti skid paint of approved make and brand including smoothening surface by sand papering etc. including using of approved primer etc. on the surface, if necessary. On steel or other metal surface: Two coats |
| 393 | The Pontoon shall be cleaned mechanically / manuallyinternal & external area prior to apply paints the pontoon internal & external hull area deck fittings shall be painted with 2-coats Tuff coat Red oxide Zinc chromate & final 2-coat as per painting schedule under instruction & satisfaction of Engineer-in-charge(Blue & White coloured paint only) |
| 394 | DRAIN, DOWN PIPES |
| 395 | Supplying, fitting , fixingC.I Grating (Heavy Type) Above 100 mm and upto 150 mm Square or round. |
| 396 | Stainless Steel railing |
| 397 | Supplying, fitting & fixing Zn -Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm Self tapping screw , EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).(i) In Roof:- a) With 0.5 mm thick sheet. |
| 398 | Galvanised iron sheets valley gutter with perimeter not less than 750 mm with 225 mm lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley gutter made of 0.63 mm. thick sheets. (300mm End lapping) |
| 399 | Grouting the foundation bolt (by HILTI method) for yoke and roller base plate from yoke staging platform as per the direction & instruction to the satisfaction of Engineer-in-charge |
| 400 | HORTICULTURE |
| 401 | Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment) |
| 402 | Supplying and fixing grasses tiles of grass Maxican Carpet/Selection No. 1 Healthy & fresh grasses (size 1\"x1\" or bigger) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from wees and fit for mowing including supplying good earth as required by Engineer-in-charge. (Rate includes supply of labour, tools & plants including materials) |
| 403 | Supplying and Planting of different plant / trees (Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift, carriage, handling, manuring, applying presticide and fertilizer etc.i) Furcaria veriegated 10-12 leaves in height 20-30cm inearthen pots of size 25cm. |
| 404 | ii) Rangon chineese of size not less than 20cm |
| 405 | China palm of leaves 4-5 in earthen pots size 25cm |
| 406 | Ficus blakii (F. Vivicon) well branched (Bushy) of height 120cm - 135 cm in earthen pot of size 30cm. |
| 407 | Ficus elastica Decora ( Rubber plant ) of height 90cm-60cm in each earthen pot of size 25cm. |
| 408 | Adenium obesum of height 90cm-60cm in earthen pots of size 25cm. |
| 409 | Bougainvillea (name variety, bushy plants, full bloom) of height 90cm-60cm in cement pots of size 30cm. |
| 410 | Areca Palm 4 - 5 suckers of height 90 cm to 105 cm in earthen pots of size 25 cm. |
| 411 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)With carried earth arranged by the contractor within a radius exceeding 5 km. but not exceeding 10 km. including cost of carried earth. |
| 412 | Supply, fitting & fixing of different items maintaining Standard Operating Procedure guideline. |
| 413 | Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). iv) 80 mm x 60 mm rectangular |
| 414 | Installation of Fire Bucket 9 L(filled with sand or water) to prevent or extinguish fire. |
| 415 | Installation of Fire Extinguisher (6 Kg) to prevent or extinguish fire. |
| 416 | Installation of buoyant device (Life Buoy) to provide Buoyancy and prevent drowning (Weight-65Kg). |
| 417 | Installation of Display Board for S.O.P. (Standard Operating Procedure) to maintain the routine operation. |
| 418 | Supplying, installation of 16 M. Highmast (Thin wall shell lighting mast polygonal tapered section made of E-350 grade of steel, hot dip galvanised, fit together in slip jointing system)6 nos luminaries with necessary lantern ring at top, inspection door at bottom, lightening arestor, canopy, winch, wire rope etc including suitable cable of approved make complete. |
| 419 | Supplying, Stainless Steel Swing Dust Bin, Garbage Bin Trash can with Removable lid Round Shape Silver Color (Set of 1) Slim and Fingerprint-Proof Finish Diameter x Height- (12X28-60Liter) of approved make complete. |
| 420 | ELECTRICAL WORK |
| 421 | Supply Fitting & FixingCeling Fan and making necessary connections as required. |
| 422 | Supply Fitting & Fixing 70 Watt LED Flood Light and making necessary connections as required. |
| 423 | Supply Fitting & Fixing20 Watt LED Tube Light and making necessary connections as required. |
| 424 | Supplying fitting fixing Solar street light with 80 mm G.I. Pipe (4.0 m long) and necessary fittings including cost of all materials , light , battery and other equipment and labour charges for fitting as per direction of Engineer-in-charge(LED 1 street light PV Module :35W panel solar charging full sunlight : 8 Hrs Battery capacity : 5200 m An Battery nominal voltage :14.8v). |
| 425 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.32A DP MCB |
| 426 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.32A SP MCB |
| 427 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 mtrs long and 1 x 4 SWG GI (Hot Dip) wire (4 mtrs long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers including supply and fixing of 15 mm dia GI pipe protection (1 mtrs long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mtrs below the ground level and restoring surface duly rammed as below.By ISI-Medium GI pipe |
| 428 | Treatment of soil by using salt and charcoal or coke for plate electrode (for soft soil/morrum soil). |
| 429 | Providing masonry enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work (1:6) of 25 cm width duly plastered with cement mortar (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 Nos 12 mm dia holes on the GI pipe. |
| 430 | Connecting the equipments to earth bus bar including supply and fixing of GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc, as required and mending good the damages.6 SWG |
| 431 | Connecting the equipments to earth bus bar including supply and fixing of GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc, as required and mending good the damages.8 SWG |
| 432 | LT Cable and AccessoriesSupply of XLPE/PVC insulated, Armoured/Unarmoured/Flexible, Aluminium conductor( all rates are excluding of vat). 3.5C x 70 Sq.mm / A2XFY |
| 433 | 4C x 10 Sq.mm Copper Armour Cable (for Ductable AC and DB) |
| 434 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 4 core 10 to 16 sqmm |
| 435 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 3.5 core upto 70 sqmm |
| 436 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :4 core 25 sqmm cable |
| 437 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :3.5 core 70 sqmm cable |
| 438 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 4 Module |
| 439 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.12 Module(2 Row) |
| 440 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required. |
| 441 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc |
| 442 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. |
| 443 | Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 444 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. Average run 5 mtr |
| 445 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. On Board |
| 446 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. Average run 1.5 mtr |
| 447 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. Average run 4.5 mtr |
| 448 | Supply, installation, testing & commissioning of heavy duty exhaust fan with gravity louvers and gaurds etc. complete in all respect as per technical specification, drawings & as required at site.300 mm dia , 1400 rpm 1 phase. |
| 449 | Supply, installation, testing & commissioning of 400mm wall fancomplete in all respect as per technical specification, drawings & as required at site. |
| 450 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 100 mm x 100 mm x 65 mm deep |
| 451 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 150 mm x 100 mm x 65 mm deep |
| 452 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works. 200 mm x 150 mm x 65 mm deep |
| 453 | Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required. 200 mm x 150 mm x 65 mm deep |
| 454 | Supply, installation, assembling, testing and commissioning of the following Light Fixtures with complete accessories, control gears, civil works complete in all respect as per technical specifications and drawings.The quoted rate shall be inclusive of Lamps,fixtures and accessories including all necessary supports, brackets, down rods and painting etc. as required.Supply of 10 W/ 15W LED Down light fittings with6.5K (Philips/ Syska or equivalent make) |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail