Tender For Construction/Retrofitting Of Pipe Water Supply Scheme At Waghli Bamnoli, Tal.Jaoli, Dist- Satara

Issued by Government Departments · jaoli, Maharashtra
Tender Value
53.08 Lakhs
Estimated cost
Bid Submission
08 Jan 2024
0 days left
EMD
53086
Bank guarantee accepted
Document Fee
5250
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jaoli → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Construction/Retrofitting Of Pipe Water Supply Scheme At Waghli Bamnoli, Tal.Jaoli, Dist- Satara

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 30-Dec-2023 2nd call Date 03-Jan-2024
2 04-Jan-2024 3rd call Date 08-Jan-2024

BOQ

Name of Work: RETRO FITTING TO PWSS AT WAGHALI (BAMNOLI) , TAL-JAOLI,DIST-SATARA
Sl. No. Item Description
1Existing Supplywell Strengthening (6 m ø 12.6 m depth)
2Excavation in general in soft material comprising of soft soil, soft murum, sand, hard murum with boulders in wet or dry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, Supply Well, etc. for lift 0 to 1.5M and lead of 150 M including barricading, guarding, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-in-charge, etc. complete excluding refillingFor Head Works on nalla or any other siteof GSDA for initial lift of 0 to 1.5 MLift 0-1.5m
3Lift 1.5 - 3m
4Lift 3-4.5 m
5Lift 4.5-6 m
6Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc.
7Desilting the Supply Well, Intake Well /Head Works, Sump of water supply /sewerage works etc. in wet or dry condition including lifts upto 9 M and lead upto 150 M as required beyond the work site, stacking, spreading, including necessary guarding, etc. complete, as directed by Engineer-in-charge.Add for each additional lift of 1.5 Mbeyond initial lift 9.0 M
8Providingandlayingin situ followinggradesofcementconcreteoftrap/ granite/ quartzite /gneiss metal for foundationand bedding including dewatering,form work, compaction, curing, finishing etc. complete.a) M-150
9Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements)Bottom Ring ( 500 mm x300 mm )
10a) ForVertical Wall (6 m below GL & 1.5 m above GL )Above 1.2 m from GL
11From GL to 5 m
12From 5 to 6 m
13Providingand fixingin positionsteel bar reinforcementof variousdiametersfor RCC piles, caps, footings, foundations,slabs, beams, columns, canopies, staircase, newels,chajjas,lintels,pardies,copings,fins,arches,etc. as per detailed designs, drawingsandschedulesincludingcutting,bending,hookingthebars,bindingwith wiresor tackweldingand supportingas required,etc.complete.(includingcost of binding wire)100 kg per cum
14Providingstucturalsteelworkin single stanchionscomposedof RSJ, channel,etc, withcaps,bases,mildsteel plates,angles,brackets,cleats,gussetplates,anchor bolts, etc. as per detaileddesign and drawing or as directed by Engineer-in-charge includingcutting,fabrication,hoisting,erecting,fixinginposition,makingriveted/bolted/weldedconnectionsandonecoatsofanticorrosivepaintandoverittwo coats of oil painting, etc. complete.
15Providingand fixing M.S. chequerredplate flooringof following thicknesssupported onM.S.angles(25x25x5 mmsize)includingwelding,cuttingandfabricatingthe plates to the requiredsquare or rounding shape,makingholes in the plate, includingprovidingandapplying3coatsofanticorrosivepaint,etc.completeasdirectedby Engineer-in-charge.6 mm thick
16Providing and fixing in position M.S. ladder 0.50 M wide consisting of 75 x 10 mm M.S. flats as stringers and 16 mm dia M.S. bars in double rows as steps placed at 25 cm c/c including cost of material and labour involved welding,anchoring and applying 3 coats of anticorrosive paint, etc. complete asdirected by Engineer-in-charge
17Dewateringtheexcavatedtrenchesandpoolsofwaterinthe buildingtrenches/ pipeline trenches,well works by using pumps and other devices including disposing offwatertosafedistanceasdirectedbyEngineer-in-charge(includingcostof machinery, labour, fuel), etc. complete.10 BHP pumps daily 8 hrs for 8 days
18Providing and fixing in position C.I. dapuri steps for 22 mm dia. M.S. step with proper anchorage,etc.andprovidingandapplying3coatsofant-corrosivepaint,etc complete as directed by Engineer-incharge
19Providing, and fixing 80 mm dia A.C. / P.V.C. pipe weep holes at 1.5 m.c/c staggered including costofallmaterialsandlabourinvolvedwithallleadsandlifts.etc.complete with all leads and lifts
20Refillingthe trencheswith available excavatedstuff with soft material first over pipe lineandthenhardmaterialin15cmlayerswithall consolidation, surcharging etc. complete.Net Qty
21Providing, erecting triple spur gear type Chain Pulley Block suitable for capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per IS 3832 carrying ISImark.1 Tonne Capacity
22Rectangular Chamber 1.5 M x 1.5 M x 1 M - 2 nos Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift of 0 to 1.5 M
23Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC M-150
24Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements)
25Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire)Tor Steel
26Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
27Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-chargeAs above of 90 x 60 cm internal size and depth upto
28Rectangular Chamber 1.5 M x 1.5 M x 1 M Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift of 0 to 1.5 M
29Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC M-150
30Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements)
31Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire)Tor Steel
32Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
33Valve chamber with cast iron manhole frame and covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion, 12 mm thick cement plaster in CM 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion x 15 cm thick slab, etc. complete as directed by Engineer-in-chargeAs above of 90 x 60 cm internal size and depth upto
34Metallic Tank 100000 litA) Foundation For Metallic TankItem NO-1 Excavation for foundation /Pipe trenches in soil/HardMurum/Soft Rock/ Hard Rock including removing the excavated materials upto a distance of 50 M and lift 1.50 m stacking and spreading as directed by Engineer in charge normal dewatering shoring and strutting preparing the bed for the foundation and excluding back filling etc.A) Soil
35B) Soft Rock
36C) Hard Rock
37For Approach RoadA) Soil
38B) Soft Rock
39C) Hard Rock
40Item NO-2 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)P.C.C. M-150
41Item No-3 Providing and laying in situ Cement Concrete of trap/ granite / quartzite /gneiss metal for RCC work in foundationlike raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)M-250
42Item No-4 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete(including cost of binding wire). Tor Steel
43B) Patable Water Tank Item No-1 Supply and installation of prefabricated ground water storage bolted tanks, acomplete package in knock down, ready to assemble construction consisting of outer wall surface made out of special grade hot dip aluminum Zincalloy, metalic factory coated steel confirming toIS-15961 2012, minimum thickness of 0.6 mm. The inner surface should be provided withliners of minimum 0.6 mm thickness of reinforce polyethylene or polye propelene or metallocene material suitable for drinking water purpose.etc. complete.
44A) For the dome type GI corrougated roof structur ewith hot dip galvanized trusses with GI manhole for access for cleaning and maintenance, 10% extra shall be added.
45B) In case rain water harvesting filters & system to catch the rain from the GI tank roofs mounted on the tank roof and supplied with the tank then 10% extra shall be added.
46C) Hilly region
47C) Compound For Metalic Water Tank :ITEM NO.1- Providing and erecting chain link fencing 1.6M. height with G.I. chain link of size 50 x 50 mm8gauge thick and fixed 75 mm above Ground level vertical M.S Angle of 40 x 40 x 6 mm size embedded in C.C. block of 1:4:8 mix of size 450X 450 x 670 mm. at 1.75 M.cc with iron bar 16 mm dia. as bold fast including welding link with angle frame at 30 cm c/c nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. lat 35 x 5 mm and 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm Angles both sides at every corner or bends embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 nm including 3 coats of oil painting etc. complete. Spec. No.: As directed by Engineer in charge.
48ITEM NO.2-Providing and fixing MS Gate 2.5 m wide for compound with 40mm dia. GI pipe approved grill work RCCM150, side piller of 25cmx40cmx2.5m height, foundation, finishing, painting etc complete.
49ITEM NO.3-Providing and fixing Wicket Gate 1.0rn wide for compound with 40inim dia. GI pipe approved grill work RCC M150, side piller of 25cmx40cmx2.5mm height, foundation, finishing, painting etc complete.
50ITEM NO.4-Online Chlorination unit -1 unit-2500000lit water chlorination capacity of single cartridge at 1ppm dosing price includes transportation upto site with installation.(As per Jalswaraj II scheme )
51Annual maintenance & operation of non electric online automatic chlorination fitted online on water supply scheme as mentioned in above item.
52Pumping Machinary for Pr.well 15 BHP, Discharge = 12482 LPH, Head = 136 m Providing, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer. Pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump.Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) upto 8 stagesProvideduplicate set of submersible pump capable of discharging 219 litres/hour against a total head 42 M be driven by 3 B.H.P electrical motor directly coupled to it . One pump will be in operation and one pump will be standby.
53Supplyingand erecting Cupboard type panel board.
54Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
55Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.50mm dia (Medium) on well
56Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 150 mm dia
57Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc complete.a) Sluice valve - PN - 1(Without bypass)50 mm dia
58Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)a) Sluice valve - PN - 1(Without bypass)50 mm dia
59Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia)
60Providing pipe type earthing with 40mm dia G.I Pipe or 20 mm dia G.I Rod complete with all materials as per specifications no EA-EPPlate type Electrode (IS 3043)1. For panel board- 1No.
61Supplying and erecting \"b\" class GI bend in position withnecessary material.50 mm dia
62Supplying and erecting \"b\" classGI Teein position withnecessary material.50 mm dia
63Gravity Main GI -40 MMspring 1 toExGSR -1000 m Dismantling dead pipeline of M.S./ R.C.C./ C.I./ P.S.C. and G.I./ A.C./ P.V.C./ S.W./ H.D.P.E. pipe including cost of necessary excavation and refilling of trenches, breaking the joints, lifting the pipes and stacking to the place as directed by Engineer-in-charge with all leads and lifts including cleaning the surface, etc. complete40mm
64Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Medium Pipe40mm
65Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeWithout by pass arrangement - PN -1 Scour Valve50 ø
66Providingandsupplying Air Valvesas per IS-10845and MJP’s standard specificationsdoubleorificetypecombinedwithscrewdownisolatingvalve,small orificeelasticballrestingonagunmetalorificenipple,largeorificevulcaniteball seatingon mouldedseatring,inletfaceanddrilled,includingall taxes(Centraland local), insurance, third party inspection charges, loading, unloding, transportatoin upto departmental stores / site, etc. complete. Air Valve Single Ball Flanged Type - PN -115 ø
67Labour SectionExcavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
68Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
69Filling in plinth and floors murum bedding intrenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)from excavated stuff
70Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.Medium Pipe40mm
71Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.Medium Pipe40mm
72Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )50 ø
73Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached.)upto 150mm
74ProvidingandconstructingB.B.masonryvalvechamberwith15cmthick1:2:4 proportionPCCbedding,excludingexcavation,B.B. masonryin C.M. 1:5 Proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge.As above of 60x45cm internal size and depth upto 0.9 m with precast R.C.C slab and cover.
75Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)Forencasingand reconstruction of road
76Refillingthetrenches withavailableexcavated stuffwithsoftmaterialfirstover pipelineandthenhardmaterialin15cmlayerswithallleadsandliftsincluding consolidation, surcharging,etc. complete.Net Volume of Refilling
77Gravity Main GI -40 MMspring 2 toExGSR -150 m Dismantling dead pipeline of M.S./ R.C.C./ C.I./ P.S.C. and G.I./ A.C./ P.V.C./ S.W./ H.D.P.E. pipe including cost of necessary excavation and refilling of trenches, breaking the joints, lifting the pipes and stacking to the place as directed by Engineer-in-charge with all leads and lifts including cleaning the surface, etc. complete40mm
78Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Medium Pipe40mm
79Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeWithout by pass arrangement - PN -1 Scour Valve50 ø
80Providingandsupplying Air Valvesas per IS-10845and MJP’s standard specificationsdoubleorificetypecombinedwithscrewdownisolatingvalve,small orificeelasticballrestingonagunmetalorificenipple,largeorificevulcaniteball seatingon mouldedseatring,inletfaceanddrilled,includingall taxes(Centraland local), insurance, third party inspection charges, loading, unloding, transportatoin upto departmental stores / site, etc. complete. Air Valve Single Ball Flanged Type - PN -115 ø
81Labour SectionExcavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
82Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5
83Filling in plinth and floors murum bedding intrenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)from excavated stuff
84Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.Medium Pipe40mm
85Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.Medium Pipe40mm
86Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )50 ø
87Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached.)upto 150mm
88ProvidingandconstructingB.B.masonryvalvechamberwith15cmthick1:2:4 proportionPCCbedding,excludingexcavation,B.B. masonryin C.M. 1:5 Proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge.As above of 60x45cm internal size and depth upto 0.9 m with precast R.C.C slab and cover.
89Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)Forencasingand reconstruction of road
90Refillingthetrenches withavailableexcavated stuffwithsoftmaterialfirstover pipelineandthenhardmaterialin15cmlayerswithallleadsandliftsincluding consolidation, surcharging,etc. complete.Net Volume of Refilling
91Distribution System Total Length = 551 m 75 ø mm to 110 ømm HDPE PN6 MATERIAL Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GSTlevied by GI & GOM in all respect etc. complete.63 ø
92Providing & Supply of Electro Fusion Fittingsin accordance with BS EN12201: Part-3 suitablefor drinking water with in black/ blue colourmanufactured from compounded PE80/ PE100virgin polymer and compatible with PE80/PE100pipes, in pressure rating SDR11 with min PN12.5rated for water application and shall be inclusive ofall cost such as testing, inspection charges,transportation up to store, transit insurance,loading, unloading, stacking excluding GST leviedby GOI & GOM in all respect, etc. complete.Couplers 63
93Equal Tee 63
94LNPE 63 Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint
95Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Medium Pipe65 ø
96Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. complete.Without by pass arrangement - PN-1.50 ø
97LABOURExcavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5
98Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5
99Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-3/259)Lift 0 to 1.5
100Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in_x0002_charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259)Lift 0 to 1.5
101Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259)Lift 0 to 1.5
102Filling in plinth and floors murum bedding intrenches with approved murum fromexcavated materials from foundation in 15cm to 20 cm layers including watering andcompaction, etc. complete. (Bd-A-10/263)from excavated stuff
103Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including allspecials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part IIWorking Pressure 6 kg/cm²63 ø
104Hydraulic testing of H. D. P. E./ M. D. P. E.pipe line to specified pressure including cost ofall materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position...63 ø
105Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.Medium Pipe65 ø
106Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.Medium Pipe65 ø
107Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )50 ø
108Providing and fixing C.I. road box including loading, unloading and carting to site of work including all necessary excavation in all types of strata and fixing in murum packing, etc. complete100 mm x 225 mm (20 kg)
109Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)For Road Reconstruction PCC M150
110Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.Net volume of refilling
111Making cross connection to existing distribution main of any type including excavation, breaking and removing existing pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line. (The number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores.)50 mm
11265 mm
113INFORMATORY SIGN BOARDS, TRIAL RUN AND CHLORINATION Commisioning running and maintaining the scheme to quantities, rate capacity, including manning necessory personnel such as operator, valveman, etc, as pr requirements of the scheme and who should also administer chemical dose for a period of one month for individual scheme together with training of personnel spared by MJP/ Local Body and handling over the scheme to Local Body after completion of the above period as directed by Engineer - in charge.For single village
114Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Chargewith two coats of greystove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground levelas per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.

AI Tender Summary

OUR REF NO 41270068
AUTHORITY Government Departments
TENDER VALUE 53.08 Lakhs
LAST DATE 08-01-2024
Authority
Authority Name Rural Development Department
Work Description Tender For Construction/Retrofitting Of Pipe Water Supply Scheme At Waghli Bamnoli, Tal.Jaoli, Dist- Satara
Basic Detail
Tender No ZPS/RWS/JJM/2023 - 1st Call
Bidding Type Tender
Location
City jaoli
State Maharashtra
Key Dates
Publish Date 04 Jan 2024
Submission Date 08 Jan 2024
Open Date 10 Jan 2024
Finance
Tender Value 53.08 Lakhs
Tender Fee 5250
EMD 53086
Exemption Not Available
Document List
NITWAGHLIBAMNOLI.pdf
Tendernotice_1.pdf
d9a96862-dbbb-4ec1-8764-11f5afc27742.html
B1WAGHLIBAMNOLI.pdf
BOQ_1701787.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 04, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 03, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 08, 2024
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 08, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 10, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

NITWAGHLIBAMNOLI.pdf

pdf

Tendernotice_1.pdf

html

d9a96862-dbbb-4ec1-8764-11f5afc27742.html

pdf

B1WAGHLIBAMNOLI.pdf

xls

BOQ_1701787.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders