Tender For Construction/Retrofitting Of Pws Scheme At Alewadi, Tal.Jaoli, Dist- Satara
Tender Overview
Project Description
Construction / Retrofitting Of Pws Scheme At Alewadi, Tal.Jaoli, Dist- Satara
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-Dec-2023 | 2nd call | Date | 03-Jan-2024 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply Well PS1 Dia 6m and Depth 12 m |
| 2 | Taking trial bore (Core Bore Sampling) by Callyx machine with TCT/NX bits to gather undisturbed strata samples for investigation in all types of strata, soft soil, murum, hard murum with boulders, soft rock, hard rock and quartzite, etc. The item includes all hire and running cost of Callyx machine, conveying all materials to site of work excluding conveyance of callyx machine and back sampling all over burden strata in glass jar and core samples serially numbered at site in a wooden core box, samples to be taken at 1.0 M interval and conveying to the place as directed by Engineer-in-charge. The diameter of bore in overburden shall be 100 mm and of NX size (50 mm) in other strata. The item shall also include M.S. casing pipe of 2.5 mm thick plate in overburden only and shall be 1.0 M above GL with cap over it.a) In overburden (soft soil, murum) |
| 3 | b) In weathered rock with boulders |
| 4 | c) In weathered rock / soft rock |
| 5 | d)In hard rock other than quartzite |
| 6 | Excavation in general in soft material comprising of soft soil, soft murum, sand, hard murumwithboulders inwetordryconditionforheadworksi.e.intakewell, connecting main, jack well, pump house, supply well, etc. for lift as below and lead of 150Mincludingbarricading,guardinganddisposingoffsurplusexcavatedstuff within a radius of 0.5 km. as directed, etc. complete excluding refilling.Lift 0.00 to 1.50 M |
| 7 | Lift 1.50 to 3.00 M |
| 8 | Lift 3.00 to 4.50 M |
| 9 | Lift 4.50 to 6.00 M |
| 10 | Excavationin generalinhard material comprisingofsoftrock,hardrock,Manjara rock,etc,byblasting/controlledblasting,chisellingasrequiredinwetordry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, supply Well, etc. for lift 0 to 1.5 M and lead of 150 M including baricading, guarding, disposingoffsurplusexcavatedstuffwithinaradiusof0.5km.asdirectedby Engineer-in-charge, excluding refillingLift 6.00 to 7.50 M |
| 11 | Lift 07.50 to 09.00 M |
| 12 | Lift 09.00 to 10.50 M |
| 13 | Lift 10.50 to 12.00 M |
| 14 | Providingandlayingin situ followinggradesofcementconcreteoftrap/ granite/ quartzite /gneiss metal for foundationand bedding including dewatering,form work, compaction, curing, finishing etc. complete.a) M-150 |
| 15 | Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements)RCC M-200 for water retaining structurea) For RingBeam Bottom Ring ( 600 mm x300 mm ) |
| 16 | a) ForVertical Wall (7.5 m below GL & 1.5 m above GL )Above 1.5 m from GL |
| 17 | From GL to 5 m |
| 18 | From 5m to 7.5m |
| 19 | Providingand fixingin positionsteel bar reinforcementof variousdiametersfor RCC piles, caps, footings, foundations,slabs, beams, columns, canopies, staircase, newels,chajjas,lintels,pardies,copings,fins,arches,etc. as per detailed designs, drawingsandschedulesincludingcutting,bending,hookingthebars,bindingwith wiresor tackweldingand supportingas required,etc.complete.(includingcost of binding wire)1% of RCC Qty |
| 20 | Providingstucturalsteelworkin single stanchionscomposedof RSJ, channel,etc, withcaps,bases,mildsteel plates,angles,brackets,cleats,gussetplates,anchor bolts, etc. as per detaileddesign and drawing or as directed by Engineer-in-charge includingcutting,fabrication,hoisting,erecting,fixinginposition,makingriveted/bolted/weldedconnectionsandonecoatsofanticorrosivepaintandoverittwo coats of oil painting, etc. complete. |
| 21 | Providingand fixing M.S. chequerredplate flooringof following thicknesssupported onM.S.angles(25x25x5 mmsize)includingwelding,cuttingandfabricatingthe plates to the requiredsquare or rounding shape,makingholes in the plate, includingprovidingandapplying3coatsofanticorrosivepaint,etc.completeasdirectedby Engineer-in-charge.6 mm thick |
| 22 | Providing and fixing in position M.S. ladder 0.50 M wide consisting of 75 x 10 mm M.S. flats as stringers and 16 mm dia M.S. bars in double rows as steps placed at 25 cm c/c including cost of material and labour involved welding,anchoring and applying 3 coats of anticorrosive paint, etc. complete asdirected by Engineer-in-charge |
| 23 | Providing and fixing G.I. pipe railing having 1.0 M height consisting 50 x 50 x 6 mm thickM.S.angles as verticals at 1.5 M c/c and additional posts at every corner with 3 rows of 25 mm dia G.I. pipes of medium class variety as horizontal andpainting 3 coats of oil paint over 1 coat of anticorrosive paint of approved colour and shadeincluding cost of all labour, transporting bends to curved shape, etc.complete. |
| 24 | Providing, lowering, laying and placing in position, shrouding material for porous pipe gallery / slotted pipe gallery / trench gallerywith all leads and lifts involved includingtransportation of materials to site of works,screening and washing of materials and placing in position with given section, etc. complete as directed by Engineer-in-charge.40 mm gauge pebbles |
| 25 | 12 mm to 20 mm gauge pebbles |
| 26 | 6 to 12 mm gauge pebbles |
| 27 | Coarse sand (from river sand at site) |
| 28 | Fine sand (from river sand at site) |
| 29 | Dewateringtheexcavatedtrenchesandpoolsofwaterinthe buildingtrenches/ pipeline trenches,well works by using pumps and other devices including disposing offwatertosafedistanceasdirectedbyEngineer-in-charge(includingcostof machinery, labour, fuel), etc. complete.7.5 BHP pumps daily 8 hrs for 40 days |
| 30 | Providing and fixing in position C.I. dapuri steps for 22 mm dia. M.S. step with proper anchorage,etc.andprovidingandapplying3coatsofant-corrosivepaint,etc complete as directed by Engineer-incharge |
| 31 | Providing, and fixing 80 mm dia A.C. / P.V.C. pipe weep holes at 1.5 m.c/c staggered including costofallmaterialsandlabourinvolvedwithallleadsandlifts.etc.complete with all leads and lifts |
| 32 | Refillingthe trencheswith available excavatedstuff with soft material first over pipe lineandthenhardmaterialin15cmlayerswithall consolidation, surcharging etc. complete. |
| 33 | Carrying out recuperation/ yield test for asserting the discharge of constructed well/ excavated profile as directed by Engineer-incharge. The test is carried out by drawing down water from the well/profile below normal/ subsoil water level upto full depth rise in water level is recorded. The normal water level/ subsoil water level in the well/ profile as well as stainer/ suction level at pump as per design of W.S. scheme shall be recorded prior to the test including cost of all materials, overhead, labourers, etc. completed as directed.Lps less than 25,000 |
| 34 | Supply WELL PS2Taking trial bore (Core Bore Sampling) by Callyx machine with TCT/NX bits to gather undisturbed strata samples for investigation in all types of strata, soft soil, murum, hard murum with boulders, soft rock, hard rock and quartzite, etc. The item includes all hire and running cost of Callyx machine, conveying all materials to site of work excluding conveyance of callyx machine and back sampling all over burden strata in glass jar and core samples serially numbered at site in a wooden core box, samples to be taken at 1.0 M interval and conveying to the place as directed by Engineer-in-charge. The diameter of bore in overburden shall be 100 mm and of NX size (50 mm) in other strata. The item shall also include M.S. casing pipe of 2.5 mm thick plate in overburden only and shall be 1.0 M above GL with cap over it.a) In overburden (soft soil, murum) |
| 35 | b) In weathered rock with boulders |
| 36 | c) In weathered rock / soft rock |
| 37 | d)In hard rock other than quartzite |
| 38 | Excavation in general in soft material comprising of soft soil, soft murum, sand, hard murumwithboulders inwetordryconditionforheadworksi.e.intakewell, connecting main, jack well, pump house, supply well, etc. for lift as below and lead of 150Mincludingbarricading,guardinganddisposingoffsurplusexcavatedstuff within a radius of 0.5 km. as directed, etc. complete excluding refilling.Lift 0.00 to 1.50 M |
| 39 | Lift 1.50 to 3.00 M |
| 40 | Lift 3.00 to 4.50 M |
| 41 | Lift 4.50 to 6.00 M |
| 42 | Excavationin generalinhard material comprisingofsoftrock,hardrock,Manjara rock,etc,byblasting/controlledblasting,chisellingasrequiredinwetordry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, supply Well, etc. for lift 0 to 1.5 M and lead of 150 M including baricading, guarding, disposingoffsurplusexcavatedstuffwithinaradiusof0.5km.asdirectedby Engineer-in-charge, excluding refillingLift 6.00 to 7.50 M |
| 43 | Lift 07.50 to 09.00 M |
| 44 | Lift 09.00 to 10.50 M |
| 45 | Lift 10.50 to 12.00 M |
| 46 | Providingandlayingin situ followinggradesofcementconcreteoftrap/ granite/ quartzite /gneiss metal for foundationand bedding including dewatering,form work, compaction, curing, finishing etc. complete.a) M-150 |
| 47 | Providing and casting in situ c.c. of trap/ granite/ quartzite/ gnesis metal of approved quality for RCC works as per detailed drawings and designs or as directed including normal dewatering,centering,form work, bally, steel propups,compaction,finishing the formed surfaceswith C.M.1:3 of sufficientminimumthicknessto give asmooth andevensurface whereevernecessaryorrougheningif specialis to be provided and curing etc. complete ( By weigh batchingand mix design for M-250 and M-300 only.Use of L&T, A.C.C.Ambuja,BirlaGold, Manikgad,Rajashree,etc. cementis permitted.)( Excluding M.S. reinforcements)RCC M-200 for water retaining structurea) For RingBeam Bottom Ring ( 600 mm x300 mm ) |
| 48 | a) ForVertical Wall (7.5 m below GL & 1.5 m above GL )Above 1.5 m from GL |
| 49 | From GL to 5 m |
| 50 | From 5m to 7.5m |
| 51 | Providingand fixingin positionsteel bar reinforcementof variousdiametersfor RCC piles, caps, footings, foundations,slabs, beams, columns, canopies, staircase, newels,chajjas,lintels,pardies,copings,fins,arches,etc. as per detailed designs, drawingsandschedulesincludingcutting,bending,hookingthebars,bindingwith wiresor tackweldingand supportingas required,etc.complete.(includingcost of binding wire)1% of RCC Qty |
| 52 | Providingstucturalsteelworkin single stanchionscomposedof RSJ, channel,etc, withcaps,bases,mildsteel plates,angles,brackets,cleats,gussetplates,anchor bolts, etc. as per detaileddesign and drawing or as directed by Engineer-in-charge includingcutting,fabrication,hoisting,erecting,fixinginposition,makingriveted/bolted/weldedconnectionsandonecoatsofanticorrosivepaintandoverittwo coats of oil painting, etc. complete. |
| 53 | Providingand fixing M.S. chequerredplate flooringof following thicknesssupported onM.S.angles(25x25x5 mmsize)includingwelding,cuttingandfabricatingthe plates to the requiredsquare or rounding shape,makingholes in the plate, includingprovidingandapplying3coatsofanticorrosivepaint,etc.completeasdirectedby Engineer-in-charge.6 mm thick |
| 54 | Providing and fixing in position M.S. ladder 0.50 M wide consisting of 75 x 10 mm M.S. flats as stringers and 16 mm dia M.S. bars in double rows as steps placed at 25 cm c/c including cost of material and labour involved welding,anchoring and applying 3 coats of anticorrosive paint, etc. complete asdirected by Engineer-in-charge |
| 55 | Providing and fixing G.I. pipe railing having 1.0 M height consisting 50 x 50 x 6 mm thickM.S.angles as verticals at 1.5 M c/c and additional posts at every corner with 3 rows of 25 mm dia G.I. pipes of medium class variety as horizontal andpainting 3 coats of oil paint over 1 coat of anticorrosive paint of approved colour and shadeincluding cost of all labour, transporting bends to curved shape, etc.complete. |
| 56 | Providing, lowering, laying and placing in position, shrouding material for porous pipe gallery / slotted pipe gallery / trench gallerywith all leads and lifts involved includingtransportation of materials to site of works,screening and washing of materials and placing in position with given section, etc. complete as directed by Engineer-in-charge.40 mm gauge pebbles |
| 57 | 12 mm to 20 mm gauge pebbles |
| 58 | 6 to 12 mm gauge pebbles |
| 59 | Coarse sand (from river sand at site) |
| 60 | Fine sand (from river sand at site) |
| 61 | Dewateringtheexcavatedtrenchesandpoolsofwaterinthe buildingtrenches/ pipeline trenches,well works by using pumps and other devices including disposing offwatertosafedistanceasdirectedbyEngineer-in-charge(includingcostof machinery, labour, fuel), etc. complete.7.5 BHP pumps daily 8 hrs for 40 days |
| 62 | Providing and fixing in position C.I. dapuri steps for 22 mm dia. M.S. step with proper anchorage,etc.andprovidingandapplying3coatsofant-corrosivepaint,etc complete as directed by Engineer-incharge |
| 63 | Providing, and fixing 80 mm dia A.C. / P.V.C. pipe weep holes at 1.5 m.c/c staggered including costofallmaterialsandlabourinvolvedwithallleadsandlifts.etc.complete with all leads and lifts |
| 64 | Refillingthe trencheswith available excavatedstuff with soft material first over pipe lineandthenhardmaterialin15cmlayerswithall consolidation, surcharging etc. complete. |
| 65 | Carrying out recuperation/ yield test for asserting the discharge of constructed well/ excavated profile as directed by Engineer-incharge. The test is carried out by drawing down water from the well/profile below normal/ subsoil water level upto full depth rise in water level is recorded. The normal water level/ subsoil water level in the well/ profile as well as stainer/ suction level at pump as per design of W.S. scheme shall be recorded prior to the test including cost of all materials, overhead, labourers, etc. completed as directed.Lps less than 25,000 |
| 66 | Pumping Machinary 5 BHP, , Discharge = 6500 LPH, Head = 86 mProviding, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer. Pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump.Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) upto 8 stages |
| 67 | Supplyingand erecting Cupboard type panel board. |
| 68 | Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 69 | Providing & erecting ISI mark G.I. pipeof followingclassanddia. including all local and central taxes, octroi, inspection charges, transportation to stores, etc. complete50mm dia (heavy) on well |
| 70 | Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 150 mm dia |
| 71 | Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc complete.a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 72 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 73 | Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia) |
| 74 | Providing pipe type earthing with 40mm dia G.I Pipe or 20 mm dia G.I Rod complete with all materials as per specifications no EA-EPPlate type Electrode (IS 3043)1. For panel board- 1No. |
| 75 | Supplying and erecting \"b\" class GI bend in position withnecessary material.50 mm dia |
| 76 | Supplying and erecting \"b\" classGI Teein position withnecessary material.50 mm dia |
| 77 | Pumping Machinary 5 BHP, , Discharge = 2000 LPH, Head = 30 mProviding, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer. Pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump.Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) upto 8 stages |
| 78 | Supplyingand erecting Cupboard type panel board. |
| 79 | Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 80 | Providing & erecting ISI mark G.I. pipeof followingclassanddia. including all local and central taxes, octroi, inspection charges, transportation to stores, etc. complete50mm dia (heavy) on well |
| 81 | Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 150 mm dia |
| 82 | Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc complete.a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 83 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 84 | Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia) |
| 85 | Providing pipe type earthing with 40mm dia G.I Pipe or 20 mm dia G.I Rod complete with all materials as per specifications no EA-EPPlate type Electrode (IS 3043)1. For panel board- 1No. |
| 86 | Supplying and erecting \"b\" class GI bend in position withnecessary material.50 mm dia |
| 87 | Supplying and erecting \"b\" classGI Teein position withnecessary material.50 mm dia |
| 88 | Pumping Machinary 3 BHP, , Discharge = 2078 LPH, Head = 26 mProviding, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer. Pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump.Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) upto 8 stages |
| 89 | Supplyingand erecting Cupboard type panel board. |
| 90 | Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 91 | Providing & erecting ISI mark G.I. pipeof followingclassanddia. including all local and central taxes, octroi, inspection charges, transportation to stores, etc. complete50mm dia (heavy) on well |
| 92 | Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 150 mm dia |
| 93 | Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc complete.a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 94 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 95 | Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia) |
| 96 | Providing pipe type earthing with 40mm dia G.I Pipe or 20 mm dia G.I Rod complete with all materials as per specifications no EA-EPPlate type Electrode (IS 3043)1. For panel board- 1No. |
| 97 | Supplying and erecting \"b\" class GI bend in position withnecessary material.50 mm dia |
| 98 | Supplying and erecting \"b\" classGI Teein position withnecessary material.50 mm dia |
| 99 | Switch RoomExcavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
| 100 | Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc complete. |
| 101 | Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. |
| 102 | Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) Excluding M. S. orTor Reinforcement |
| 103 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. |
| 104 | Providing and casting in situ Cement Concrete of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted )RCC Column M-200 |
| 105 | Providing and casting in situ C. C. of trap / granite / quartzite/ gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C. M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever nesessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.)RCC beam & lintel M-200 |
| 106 | Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and desingns or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use ofL&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) Slab M-200 |
| 107 | Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use fo L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) Excluding M S or Tor reinforcement.Chajja M-200 |
| 108 | Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar of following proportion superstructure including striking out & racking out joint watering and scafolding etc complete. |
| 109 | Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation ,slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) |
| 110 | Providing and laying Rough shahabad stone flooring upto 40 mm. thick and of required width in plain / diamond pattern on a bed of bed 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaning etc. complete. |
| 111 | Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete |
| 112 | Providing sand faced plasterexternally in cement motar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 Kg. per cement bag, curing the same fornot less than 2 days and keeping the surface of the base coat rough to recive the sand faced tretment 6 to8 mm. thick in cement mortar 1:4 finishingthe surface by taking out grains and curing for foureen days scaffolding etc. complete. |
| 113 | Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc.complete. |
| 114 | Provinding and applying washable oil-bound distemper of approved colour and shade to old and new surface in two coats including scaffolding preparing the surfaces (excluding the primer coat) etc. complete. |
| 115 | providing and fixing steel frame of angle 50 x 50 x 6 mm size for window with 16 mm with mild steel bars horizontally at 10 cm c/c for ventilator portion and at 15 cm c/c for remaining portion with M.S. flat of size 40 x 6 mm vertical at center including iron hold fast boxes for fixing 40 x 6 mm vertical at center including iron hold fast boxes for fixing 40 x 6 mm vertical at center including iron hold fast boxes for fixing shutters including welding finishing painting etc. complete. |
| 116 | Providing and fixing in position factory made box type steel window with glazed fan light including steelwindows of cold rolled section of 105 mm x 60 mm x 1.25 mm thick frame section filled with cement concrete (1:2:4) and metal pressed steel shutters of 20 gauge (1mm )as per detailed drawing and design or as directed including providing horizontal mild steel 12 mm square bars at 10 cm center to center, required F7B section, section76, section 20 mm x 5 mm mild steel flat for shutter and F4B section for frame, 3 mm thick glass of approved quality for fan light necessary fixtures and fastening etc.complete finishing with one coat of anticorrosive paint etc.complete |
| 117 | Providing and fixingsteelframe door of angle 50X 50X 6 mm with 16mm with mild steel bar horizantally at 10 cm c/c for ventilator portionincluding iron hold fast boxes for fixing shutters including welding, finishing,painting etc complete. |
| 118 | Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15mm (5mmx3) thick x 30 mm width on one style and top rail and 10 mm (5mmx2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and/orprelim colours on one side after routing the moulded design on flush doors and 2 mmplain and/or prelam PVC on other side using rubber adhesive on flush door and solven tcement adhesive on the PVC lipping etc.as per direction of Engineer in charge and manufacturers specification and drawing etc. complete. |
| 119 | Pumping Machinary 5 BHP, , Discharge = 6853 LPH, Head = 90 mProviding, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer. Pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump.Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) upto 8 stages |
| 120 | Supplyingand erecting Cupboard type panel board. |
| 121 | Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 122 | Providing & erecting ISI mark G.I. pipeof followingclassanddia. including all local and central taxes, octroi, inspection charges, transportation to stores, etc. complete50mm dia (heavy) on well |
| 123 | Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 150 mm dia |
| 124 | Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc complete.a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 125 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 126 | Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia) |
| 127 | Providing pipe type earthing with 40mm dia G.I Pipe or 20 mm dia G.I Rod complete with all materials as per specifications no EA-EPPlate type Electrode (IS 3043)1. For panel board- 1No. |
| 128 | Supplying and erecting \"b\" class GI bend in position withnecessary material.50 mm dia |
| 129 | Supplying and erecting \"b\" classGI Teein position withnecessary material.50 mm dia |
| 130 | Pumping Machinary 5 BHP, , Discharge = 6853 LPH, Head = 102 mProviding, erecting and giving tests of submersible pump set confirming to IS 8034 and motor confirming to IS 9283, with water proof winding and discharge with stainless steel shaft. Mortar suitable for working on 415 V = 10% 3 phase 50 Hz A.C. supply with cable guard, thrush carbon/fible bearing to withstand entire hydraulic thrust with suitable suction strainer. Pump should have suitable discharge outlet as per manufacture\"s design. Antithrust streamlined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump.Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) upto 8 stages |
| 131 | Supplyingand erecting Cupboard type panel board. |
| 132 | Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 133 | Providing & erecting ISI mark G.I. pipeof followingclassanddia. including all local and central taxes, octroi, inspection charges, transportation to stores, etc. complete50mm dia (heavy) on well |
| 134 | Providing, supplying and fixing ISI mark CI D/F Reflux valve (non-return valves of following dia including all taxes (central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store/site, unloading, stacking etc. complete. Reflux valves as per I.S. 5312 part I (1984)a) Without bypass arrangement - PN - 150 mm dia |
| 135 | Providing and fixing double flanged sluice valve confirming for IS-2096/14846 including worn gear arrangements as per test pressure stainles steel spindle, caps including all taxes transportation etc complete.a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 136 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)a) Sluice valve - PN - 1(Without bypass)50 mm dia |
| 137 | Providing and erecting pressure gauge of required capacity complete with syphon tube, isolating cock suitable for 12mm dia GI pipe. Pressure gauge shall be installed as directed, with tapping on rising main pressure gauge (100 mm dia) |
| 138 | Providing pipe type earthing with 40mm dia G.I Pipe or 20 mm dia G.I Rod complete with all materials as per specifications no EA-EPPlate type Electrode (IS 3043)1. For panel board- 1No. |
| 139 | Supplying and erecting \"b\" class GI bend in position withnecessary material.50 mm dia |
| 140 | Supplying and erecting \"b\" classGI Teein position withnecessary material.50 mm dia |
| 141 | Rising Main Providing and supplying in standard lengthsPolyethelene Pipes, confirming to IS 4984 /14151 / 12786 / 13488 with nesessary jointingmaterial like mechanical connector i. e. thread /insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete.HDPE 90 mm - 6 kg/cm2 |
| 142 | .HDPE 90 mm - 8 kg/cm2 |
| 143 | .HDPE 90 mm - 10 kg/cm2 |
| 144 | Providing & Supply of Electro Fusion Fittingsin accordance with BS EN12201: Part-3 suitablefor drinking water with in black/ blue colourmanufactured from compounded PE80/ PE100virgin polymer and compatible with PE80/PE100pipes, in pressure rating SDR11 with min PN12.5rated for water application and shall be inclusive ofall cost such as testing, inspection charges,transportation up to store, transit insurance,loading, unloading, stacking excluding GST leviedby GOI & GOM in all respect, etc. complete.Couplers 90 |
| 145 | Equal Tee 90 |
| 146 | LNPE 90 Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint |
| 147 | Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Medium Pipe80 ø |
| 148 | Providing and supplying ISl mark CI D/F reflux valves (non-return valves ) of following dia including all taxes (Central and Local), railway freight, inspection charges unloding from railwaywagon,loadinginto truck, transportation upto departmentalstroes/ site, unloading, stacking etc. complete.Reflux valves as per I.S.5312 Part I (1984)Without by pass arrangement - PN -180 ø |
| 149 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. completeWithout by pass arrangement - PN -1 Scour Valve80 ø |
| 150 | Providingandsupplying Air Valvesas per IS-10845and MJP’s standard specificationsdoubleorificetypecombinedwithscrewdownisolatingvalve,small orificeelasticballrestingonagunmetalorificenipple,largeorificevulcaniteball seatingon mouldedseatring,inletfaceanddrilled,includingall taxes(Centraland local), insurance, third party inspection charges, loading, unloding, transportatoin upto departmental stores / site, etc. complete. Air Valve Single Ball Flanged Type - PN -125 ø |
| 151 | Labour SectionExcavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5 |
| 152 | Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-2/259)Lift 0 to 1.5 |
| 153 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in_x0002_charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259)Lift 0 to 1.5 |
| 154 | Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259)Lift 0 to 1.5 |
| 155 | Filling in plinth and floors murum bedding intrenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)from excavated stuff |
| 156 | Lowering, Laying and Jointing H. D. P. E./M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part IIHDPE 90 mm - 6 kg/cm2 |
| 157 | HDPE 90 mm - 8 kg/cm2 |
| 158 | HDPE 90 mm - 10 kg/cm2 |
| 159 | Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position..Working pressure 6 kg/cm2HDPE 90 mm - 6 kg/cm2 |
| 160 | HDPE 90 mm - 8 kg/cm2 |
| 161 | HDPE 90 mm - 10 kg/cm2 |
| 162 | Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.Medium Pipe80 ø |
| 163 | Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.Medium Pipe80 ø |
| 164 | Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )80 ø |
| 165 | Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameters of pipe lines (type design attached.)upto 150mm |
| 166 | ProvidingandconstructingB.B.masonryvalvechamberwith15cmthick1:2:4 proportionPCCbedding,excludingexcavation,B.B. masonryin C.M. 1:5 Proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge.As above of 60x45cm internal size and depth upto 0.9 m with precast R.C.C slab and cover. |
| 167 | Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)Forencasingand reconstruction of road |
| 168 | Refillingthetrenches withavailableexcavated stuffwithsoftmaterialfirstover pipelineandthenhardmaterialin15cmlayerswithallleadsandliftsincluding consolidation, surcharging,etc. complete.Net Volume of Refilling |
| 169 | Making cross connection to existing distribution main of any type including excavation, breaking and removing existing pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line. (The number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores.)80mm |
| 170 | 100 mm |
| 171 | Distribution System Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GSTlevied by GI & GOM in all respect etc. complete.63 ø |
| 172 | Providing & Supply of Electro Fusion Fittingsin accordance with BS EN12201: Part-3 suitablefor drinking water with in black/ blue colourmanufactured from compounded PE80/ PE100virgin polymer and compatible with PE80/PE100pipes, in pressure rating SDR11 with min PN12.5rated for water application and shall be inclusive ofall cost such as testing, inspection charges,transportation up to store, transit insurance,loading, unloading, stacking excluding GST leviedby GOI & GOM in all respect, etc. complete.Couplers 63 |
| 173 | Equal Tee 63 |
| 174 | LNPE 63 Spigot Long Neck Pipe End (Stub End) for Electro Fusion joint |
| 175 | Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Medium Pipe65 ø |
| 176 | 80 ø |
| 177 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOt & GOM in all respect etc. complete.Without by pass arrangement - PN-1.65 ø |
| 178 | 80 ø |
| 179 | LABOURExcavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5 |
| 180 | Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5 |
| 181 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in_x0002_charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259)Lift 0 to 1.5 |
| 182 | Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259)Lift 0 to 1.5 |
| 183 | Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263) from excavated stuff |
| 184 | Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including allspecials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part IIWorking Pressure 6 kg/cm²63 ø |
| 185 | Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position...63 ø |
| 186 | Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.Medium Pipe65 ø |
| 187 | 80 ø |
| 188 | Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.Medium Pipe65 ø |
| 189 | 80 ø |
| 190 | Lowering, laying, jointing in positionfollowing CI/DF Reflux, butterfly valves and sluice valves including cost of all labors jointing material including nutbolts and giving satisfactory hydraulic testing etc complete ( Rates for all class of valves )65 ø |
| 191 | 80 ø |
| 192 | Providing and fixing C.I. road box including loading, unloading and carting to site of work including all necessary excavation in all types of strata and fixing in murum packing, etc. complete100 mm x 225 mm (20 kg) |
| 193 | Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)For Road Reconstruction PCC M150 |
| 194 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.Net volume of refilling |
| 195 | Making cross connection to existing distribution main of any type including excavation, breaking and removing existing pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line. (The number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores.)80mm |
| 196 | 100 mm |
| 197 | INFORMATORY SIGN BOARDS AND TRIAL RUN Commisioning running and maintaining the scheme to quantities, rate capacity, including manning necessory personnel such as operator, valveman, etc, as pr requirements of the scheme and who should also administer chemical dose for a period of one month for individual scheme together with training of personnel spared by MJP/ Local Body and handling over the scheme to Local Body after completion of the above period as directed by Engineer - in charge. |
| 198 | Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Chargewith two coats of greystove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground levelas per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete. |
| 199 | FHTCProviding and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour , UPVC/MDPE Pipe of required length with or without Road crossing as described below, including cost of specials like Saddle/Clamp Saddle of suitable material, and diameter suitable for Distribution main, 15mm /20mm/ 25mm respective Dia Heavy duty Brass/Polyprophylyne(Twin Jacketed ) Ferrule , Male and Female thread adapter Elbow, Bends,couplers ,Tees, Clamps of suitable material and sundry materials as per requirment, including providing and fixing medium duty 15.mm brass bib tap, GI casing pipe of suitable diameter of 32mm/ 40mm/ 50mm respectively of required length for Road crossing, including requird labour for excavation in all types of strata up to the depth of 0.75m or as per site requirement,all types of plumbing fittings, refilling , Closing the water supply in that area, dewatering, hydraulic testing and restarting the water supply ,transportation of material etc. complete as directed by Engineer inFor MDPE/UPVC Pipe Service Connection on Disribution main.(Without Road Crossing)For 15 mm Service connection |
| 200 | For MDPE/UPVC Pipe Service Connection on Disribution main.(With Road Crossing)For 15 mm Service connection |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender