Tender For Internal Painting And Anti-Termite Work In Hostel 3 , 5 And 7 At Aiims Patna, patna-Bihar

All India Institute Of Medical Sciences-AIIMS has published Tender For Internal Painting And Anti-Termite Work In Hostel 3 , 5 And 7 At Aiims Patna. Submission Date for this Tender is 10-01-2024. Pest Control Services Tenders in patna Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

41242711
Tender For Internal Painting And Anti-Termite Work In Hostel 3 , 5 And 7 At Aiims Patna
Open Tender
Indian
Bihar
patna
10-01-2024

Tender Details

Tender For Internal Painting And Anti-Termite Work In Hostel 3 , 5 And 7 At Aiims Patna

Key Value

Document Fees
INR 1500 /-
EMD
INR 10946.0 /-
Tender Value
INR 5.47 Lakhs /-

BOQ Items

Name of Work:Internal Painting and anti-termite work in hostel3 , 5 and 7 at AIIMS Patna.
Sl. No. Item Description
1EARTH WORK Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos emulsifiable concentrate of 20%
2Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along the external wall below concrete or masonry apron us- ing chemical emulsion @ 2.25 litres per linear metre includ- ing drilling and plugging holes etc.:With ChlorpyriphosE.C. 20% with 1% concentration
3Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 ce- ment : 2 coarse sand) to the full depth of the hole :With Chlorpyriphos E.C. 20% with 1% concentration
4WOOD AND P. V. C. WORKProviding and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
5Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading
6Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : (copper oxidized as per IS: 1378)300x16 mm
7Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : (copper oxidized as per IS: 1378)250x10 mm
8Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : (copper oxidized as per IS: 1378) 125 mm
9Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm
10Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm
11Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC "C" channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the "C" Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer"s specification & drawing. 30 mm thick plain PVC door shutters
12STEEL WORKProviding & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.0 mm thick glass panes (weights not less than 12.50 kg/ sqm)
13FLOORINGProviding and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm
14FINISHINGApplying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
15Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
16Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
17Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
18REPAIRS TO BUILDING Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand)
19SANITARY INSTALLATIONSProviding and fixing 600x450 mm beveled edge mirror of superiorglass (of approved quality) complete with 6 mm thick hard boardground fixed to wooden cleats with C.P. brass screws and washers complete.
20Providing and applying for water proofing of approved brand and manufacture over the plastered wall surface to prepare the damp proof surface all complete as per specification and direction of engineer incharge
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail