Tender For Repair / Maintenance Of Standby Power Supply System, High Mast Lights, Tarmech Lights, Aviation Lights, Hanger Lights, Dispersal Lights And Allied Works At Certain Locations At Afs Under Ge (Af) Jorhat., jorhat-Assam

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Standby Power Supply System, High Mast Lights, Tarmech Lights, Aviation Lights, Hanger Lights, Dispersal Lights And Allied Works At Certain Locations At Afs Under Ge (Af) Jorhat.. Submission Date for this Tender is 09-01-2024. Power Supply Unit Tenders in jorhat Assam. Bidders can get complete Tender details and download the document.




Tender Notice

41238717
Corrigendum : Tender For Repair / Maintenance Of Standby Power Supply System, High Mast Lights, Tarmech Lights, Aviation Lights, Hanger Lights, Dispersal Lights And Allied Works At Certain Locations At Afs Under Ge (Af) Jorhat.
Open Tender
Indian
Assam
jorhat
09-01-2024

Tender Details

Tender For Repair / Maintenance Of Standby Power Supply System, High Mast Lights, Tarmech Lights, Aviation Lights, Hanger Lights, Dispersal Lights And Allied Works At Certain Locations At Afs Under Ge (Af) Jorhat.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:REPAIR / MAINT OF STANDBY POWER SUPPLY SYSTEM, HIGH MAST LIGHTS, TARMECH LIGHTS, AVIATION LIGHTS, HANGER LIGHTS, DISPERSAL LIGHTS AND ALLIED WORKS AT CERTAIN LOCATIONS AT AFS UNDER GE (AF) JORHAT
Sl. No. Item Description
1Labour only for servicing of 750 KVA DG Set with draining out and refilling/top up of engine oil / lubricant coolant, taking out of unserviceable Oil Filter element, Fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element, cleaning of fuel tank, etc. complete all as specified and as directed. Make : Kirloskar Note : (i) Location may be ascertained before quoting of tender. (ii) Spares (as per sample) and lubricantto be measured and paid separately under respective items here-in-after.
2Supply only Fuel Filter Element
3Supply onlyLub Oil Filter Element,
4Supply onlyFuel Filter Cartridge
5Supply onlyAir Filter Element (outer)
6Supply onlyAir Filter Element (inner)
7Supply only "V" Belt,
8Supply onlyHose Rubber,
9Supply only Hose Fuel
10Supply only Expansion Bellow
11Supply only thermostat
12Labour only for servicing of 320 KVA DG Set with draining out and refilling / top up of engine oil / lubricant coolant, taking out of unserviceable oil filter element, fuel filter element, fuel flexible pipe, V-belt for water pump and alternator, air filter element, cleaning of fuel tank, etc. complete all as specified and as directed. Make : Kirloskar. Note : (i) Loc. : Main Power House (ii) Spares (as per sample) and lubricant to be measured and paid separately under respective items here-in-after.
13Supply only fuel filter element
14Supply only lubricant oil filter element
15Supply onlyFuel Filter cartridge
16Supply onlyAir Filter Element (outer)
17Supply onlyAir Filter Element (inner)
18Supply only "V" Belt,
19Supply onlyHose Rubber,
20Supply onlyHose Fuel pipe
21Supply onlyExpansion Bellow
22Supply only fuel pipe
23Calibration of fuel injection pump including minor repair and servicing of injector nozzles complete all as specified and as directed
24Labour only for servicing of 320 KVA DG Set with draining out and refilling / top up of engine oil / lubricant coolant, taking out of unserviceable Oil Filter element, Fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element, cleaning of Fuel tank etc. complete all as specified and as directed. Make : Jakson. Note : (i) Location : Main Power House (ii) Spares (as per sample) and lubricantto be measured and paid separately under respective items here-in-after.
25Supply only fuel filter element
26Supply only lubricant oil filter element,
27Supply onlyFuel Filter cartridge
28Supply onlyAir Filter Element,(outer)
29Supply onlyAir Filter Element,(inner)
30Supply only"V" Belt/fan belt,
31Supply onlyHose Rubber,
32Supply only hose fuel
33Supply only expansion Bellow
34Supply only water separator
35Calibration of fuel injection pump including minor repair and servicing of injector nozzles complete all as specified and as directed.
36Labour only for servicing of 250 KVA DG Set with draining out and refilling / top up of engine oil / lubricant coolant, taking out of unserviceableOil Filter element, Fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element, cleaning of Fuel tank etc. complete all as specified and directed. Make : Kirloskar. Note : (i) Loc. : 49 Sqn Stage-III bldg. (ii) Spares (as per sample) and lubricantto be measured and paid separately under respective items here-in-after.
37Supply only Lub Oil Filter element
38Supply only Fuel Filter element
39Supply only Air Filter Element, (Primary)
40Supply only Air Filter Element, (Secondary)
41Supply only "V" Belt/fan belt
42Supply only Hose Rubber
43Supply only Gasket water pump
44Supply only Solenoid switch 24 Volts
45Supply only Expansion Bellow
46Calibration of fuel injection pump including minor repair and servicing of injector nozzles complete all as specified and as directed.
47Labour only for servicing of 200 KVA DG Set with draining out and refilling / top up of engine oil / lubricant coolant, taking out of unserviceableOil Filter element, Fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element, cleaning of Fuel tank etc.Complete all as specified and directed. Make : Cummins. Note : (i) Loc. : Auditorium. (ii) Spares (as per sample) and lubricantto be measured and paid separately under respective items here-in-after.
48Supply only Lub Oil Filter element
49Supply only Fuel Filter element
50Supply only Air Filter Element, (Primary)
51Supply only Air Filter Element, (Secondary)
52Supply only "V" Belt/fan belt
53Supply only Hose Rubber
54Supply only Gasket water pump
55Supply only Solenoid switch 24 Volts
56Supply only Expansion Bellow
57Calibration of fuel injection pump including minor repair and servicing of injector nozzles complete all as specified and as directed
58Labour only for servicing of 200 KVA DG Set with draining out and refilling / top up of engine oil / lubricant coolant, taking out of unserviceableOil Filter element, Fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element, cleaning of Fuel tank etc. complete all as specified and directed. Make : Kirlosker. Note : Loc. : MGR. (ii) Spares (as per sample) and lubricantto be measured and paid separately under respective items here-in-after.
59Supply only Lub Oil Filter element
60Supply only Fuel Filter element
61Supply only Air Filter Element, (Primary)
62Supply only Air Filter Element, (Secondary)
63Supply only "V" Belt/fan belt
64Supply only Hose Rubber
65Supply only Gasket water pump
66Supply only Expansion Bellow
67Calibration of fuel injection pump including minor repair and servicing of injector nozzles complete all as specified and as directed.
68Labour only for servicing of 160 KVA DG Set with draining out and refilling / top up of engine oil / lubricant coolant,taking out of unserviceable Oil Filter element, Fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element,cleaning of Fuel tank etc. complete all as directed. Make : Kirloskar. Note : Loc. : WWR, Rubber Store & PS II. (ii) Spares (as per sample) and lubricantto be measured and paid separately under respective items here-in-after.
69Supply only Fuel Filter element,
70Supply only Lub Oil Filter element,
71Supply only Air cleaner assembly with safty element,
72Supply only "V" Belt/fan belt,
73Supply only Hose Rubber,
74Supply only Hose for water pipe,
75Supply only Hose for air cleaner
76Supply only Fuel pipe (Fuel filter to fuel pump)
77Supply only Expansion Bellow
78Calibration of fuel injection pump including minor repair and servicing of injector nozzles complete all as specified and as directed
79Labour only for servicing of 125 KVA DG Set with draining out and refilling / top up of engine oil/lubricant coolant, taking out of unserviceableOil Filter element, Fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element, cleaning of Fuel tank etc. complete all as specified and as directed. Make : Greaves. Note : Loc. : Near WT No. 13, Avonics Lab. (ii) Spares (as per sample) and lubricantto be measured and paid separately under respective items here-in-after.
80Supply only Lub Oil Filter element
81Supply only Fuel Filter element
82Supply only Air Filter Element, (Primary)
83Supply only Air Filter Element, (Secondary)
84Supply only "V" Belt/fan belt
85Supply only Hose Rubber
86Supply only Expansion Bellow
87Labour only for servicing of 100 KVA DG Set with draining out and refilling / top up of engine oil / lubricant coolant,taking out of unserviceableOil Filter element, Fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element,cleaning of Fuel tank etc. complete all as specified and as directed. Make : Kirloskar, Ashok Leyland and Greaves. Note : (i) Loc. : CAN Project, ATC & 43 Sqn and Near signal sub Stn respectivelly. (ii) Spares (as per sample) and lubricantto be measured and paid separately under respective items here-in-after.
88Supply only Fuel Filter element
89Supply only Lub Oil Filter element
90Supply only Air Filter Element, (Inner & outer)
91Supply only "V" Belt
92Supply only Hose Rubber
93Supply only Expansion Bellow
94Labour only for servicing of 100 KVA DG Set with draining out and refilling / top up of engine oil/lubricant coolant, taking out of unserviceable Oil Filter element, fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element,cleaning of fuel tank etc. complete all as specified and as directed. Make : Cummins. Note : Loc. : Base Ops and AATC (ii) Spares (as per sample) and lubricantto be measured and paid separately under respective items here-in-after.
95Supply only Lub Oil Filter element
96Supply only Fuel Filter element
97Supply only Air Filter Element, (Primary)
98Supply only Air Filter Element, (Secondary)
99Supply only "V" Belt
100Supply only Hose Rubber
101Supply only Expansion Bellow
102Labour only for servicing of 62.5 KVA DG Set with draining out and refilling / top up of engine oil / lubricant coolant, taking out of unserviceable Oil Filter element, fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element,cleaning of Fuel tank etc. complete all as specified and as directed. Make :Cummins. Note : (i) Loc : Logistic Section (ii) Spares (as per sample) and lubricantto be measured and paid separately under respective items here-in-after.
103Supply only Lub Oil Filter element
104Supply only Fuel Filter element
105Supply only Air Filter Element, (Primary)
106Supply only Air Filter Element, (Secondary)
107Supply only "V" Belt
108Supply only Hose Rubber
109Labour only for servicing of 63 KVA//62.5 KVA DG Set with draining out and refilling / top up of engine oil / lubricant coolant, taking out of unserviceable Oil Filter element, fuel filter element, fuel flexible pipe, V- belt for water pump and alternator, air filter element,cleaning of fuel tank etc. complete all as specified and directed. Make : Kirloskar. Note : (i) Loc. : Avionic Lab - 1, OTES Hall, OMQ (ii) Spares (as per sample) and lubricantto be measured and paid separately under respective items here-in-after.
110Supply only Air Filter Element, (outer)
111Supply only Air Filter Element, (inner)
112Supply only Hose rubber,
113Supply only "V" Belt/fan belt
114Supply only Fuel Filter Element,
115Supply only Lub oil filter element,
116Supply only L.O. Hose. (FIP),
117Supply only Fuel pipe (Feed pump to fuel filter)
118Supply only Fuel pipe( Fuel filter to fuel pump)
119Labour only for servicing of 30 to 40 KVA DG Set with draining out and refilling / top up of engine oil / lubricant coolant, taking out of unserviceable Oil Filter element, fuel filter element, fuel flexible pipe, V- belt for water pump and alternator, air filter element,cleaning of Fuel tank etc. complete all as specified and as directed. Make : Kirloskar. Note : (i) Location :-16 Provost Unit, 43 Sqn, Perimeter-3 (ii) Spares (as per sample) and lubricantto be measured and paid separately under respective items here-in-after.
120Supply only Air Filter Element, (outer)
121Supply only Air Filter Element, (inner)
122Supply only Hose radiator,
123Supply only "V" Belt
124Supply only Fuel Filter Element,
125Supply only Lub oil filter element,
126Supply only L.O. Hose. (FIP),
127Supply only Fuel pipe (Feed pump to fuel filter)
128Supply only Fuel pipe( Fuel filter to fuel pump)
129M&L for dismantling of radiator assembly of 30/40 KVA from generating set and re-fixing of the same after proper cleaning of the copper cooling tubes with caustic soda and brazing the tube if any leakage observed during cleaning complete all as specified and as directed.
130All as per Serial item No. 14 here-in-before but for 62.5/63 KVADG set.
131All as per Serial item No. 14 here-in-before but for 100 /125 KVA DG set.
132All as per Serial item No. 14 here-in-before but for 160 KVA DG set.
133All as per Serial item No. 14 here-in-before but for 200/250 KVA DG set.
134All as per Serial item No. 14 here-in-before but for 320 KVA DG set.
135All as per Serial item No. 14 here-in-before but for 750 KVA DG set.
136Supply only engine oil 20W/40multi grade to topup / refilling of all DG sets of various capacity, model & locations as mentioned here-in-before as per the standard practice complete all as specified and as directed.
137Supply only coolant suitable for DG set as per manufacture"s recommendation complete all as specified and as directed.
138Supply and pouring distilled water / acid mixure for battery and radiator complete all as specified and as directed.
139S&F Glass wool insulation (50mm thick), duly wrapped over the exhaust pipe (80 - 100mm dia) of generating set includingcladding over the insulation with aluminium foiltape complete all as specified and as directed. Note :Length of exhaust pipe shall be taken into account for measurement.
140M&L for repairing of AMF panel suitable for 62.5 KVA to 100 KVADG set, including repair / partly replacement (if and asrequired) ofinternal wiring, fuse holder 160 Amps - 03 Noscomplete all as specified and as directed.
141M&L for repairing of AMF panel suitable for 160 KVA to 200 KVA DG set, etc including repairing of internal wiring complete all as specified and as directed.
142M&L for repairing of AMF panel suitable for 250 KVA to 320 KVADG set, including internal wiring complete all as specified and as directed.
143Disconnecting the self starter (24 volt) from the engine body, dismantling the same, checking for identification of faulty spares and reassembling the same after replacement of faulty spares (if required) including refixing to it"s original position (for 160 to 320KVA DG) complete all as specified and as directed. Note: Spares required to be replaced shall be measured and paid separately as below.
144Supply only clutch assembly Make : LUCAS TVS
145Supply only Bendex pinion Make : LUCAS TVS
146Supply only Solenoid switch Make : LUCAS TVS
147Supply only Carbon Brush Make : LUCAS TVS
148Supply only Armature Field Coil Make : LUCAS TVS
149Supply only Bush Make : LUCAS TVS
150Supply only self armature coil Make : LUCAS TVS
151Disconnecting the self starter (24 volt) from the engine body, dismantling the same, checking for identification of faulty spares and reassembling the same after replacement of faulty spares (if required) including refixing to its original position (for 63 to 125 KVA DG) complete all as specified and as directed. Note: Spare required to be replaced shall be measured and paid separately as below.
152Supply only clutch assembly. Make : LUCAS TVS
153Supply only Bendex pinion Make : LUCAS TVS
154Supply only Solenoid switch Make : LUCAS TVS
155Supply only Carbon Brush Make : LUCAS TVS
156Supply only Armature Field Coil Make : LUCAS TVS
157Supply only Bush Make : LUCAS TVS
158Supply only self armature coil Make : LUCAS TVS
159S&F automatic voltage regulator (24 Volt) of the following DG capacity including taking down old unserviceable one complete all as specified and as directed of the followings:- Make : Stamford/Kirloskar/MRI /Crompton Greaves
160Suitable for 62.5/63 KVA DG Set,
161Suitable for 100/125 KVA DG Set,
162Suitable for 160 KVA DG Set,
163Suitable for 200/250 KVA DG Set,
164Suitable for 320 KVA DG Set,
165Suitable for 750 KVA DG Set,
166S&F as in repairs battery, 12 volt, 180 AH, heavy duty battery complete all as specified and as directed. MAKE : EXIDE/AMARON/AMCO
167S&F as in repairsbattery, 12 volt, 150 AH, heavy duty battery complete all as specified and as directed. MAKE : EXIDE/AMARON/AMCO
168S&F as in repairsbattery, 12 volt, 100 AH, heavy duty battery complete all as specified and as directed. MAKE : EXIDE/AMARON/AMCO
169S&F door lock assembly with keys suitable for aqustic enclosure for DG Sets of any capacity including all accessories complete all as specified and as directed.
170S&F as in repairs Automatic Battery Charger, I/P-230 Volt, AC, O/P - 12Volt DC, 10 Amps. having electric circuit consisting of triodes rectifiers, capacitors and resistance etc. The battery charger should be able to charge the battery at all the time whenever electric supply given to battery charger though control panel or electric power point complete all as specified and as directed. Make : Escorp/Su-Kam/Microtek/Exide
171S&F as in repairs Automatic Battery Charger, I/P-230 Volt, AC, O/P - 24Volt DC, 10 Amps. having electric circuit consisting of triodes rectifiers, capacitors and resistance etc. The battery charger should be able to charge the battery at all the time whenever electric supply given to battery charger though control panel or electric power point, complete all as specified and as directed. Make : Escorp/Su-Kam/Microtek/Exide
172S&F Power contactor of 600 Amps, 4 Pole with 2 NO & 2 NCand auxilary contact block of coil rating 415 Volt, 50 Hz,Including taking out old unserviceable one complete all as specified and as directed. Make : L&T, Cat No : CS97027, Type : MCX45 or equivalent model from make HAVELLS / BCH/Siemens/Legrand.
173S&F Power contactor of 500 Amps, 4 Pole with 2 NO & 2 NCand auxilary contact block of coil rating 415 Volt, 50 Hz,Including taking out old unserviceable one complete all as specified and as directed. Make : L&T, Cat No : CS97026, Type : MCX44 or equivalent model from make HAVELLS / BCH/Siemens/Legrand
174S&F Power contactor of 400 Amps, 4 Pole with 2 NO & 2 NCand auxilary contact block of coil rating 415 Volt, 50 Hz,Including taking out old unserviceable one complete all as specified and as directed. Make : L&T, Cat No : CS97025, Type : MCX43 or equivalent model from make HAVELLS / BCH/Siemens/Legrand
175S&F Power contactor of 360 Amps, 4 Pole with 2 NO & 2 NCand auxilary contact block of coil rating 415 Volt, 50 Hz,Including taking out old unserviceable one complete all as specified and as directed. Make : L&T, Cat No : CS97024, Type : MCX41 or equivalent model from make HAVELLS / BCH /Siemens/Legrand.
176S&F Power contactor of 250/255 Amps, 4 Pole with 2 NO & 2 NC auxilary contacts of coil rating 415 Volt, 50 Hz,Including taking out old unserviceable one complete all as specified and as directed. Make : L&T, Cat No.: CS97022; Type : MCX34 or equivalent model from make HAVELLS / BCH /Siemens/Legrand
177S&F Power contactor of 200 Amps, 4 Pole with 2 NO & 2 NC auxilary contact of coil rating 415 Volt, 50 Hz, including taking out old unserviceable one complete all as specified and as directed. Make : L&T, Cat No : CS97021, Type : MCX 33 or equivalent model from make HAVELLS / BCH /Siemens/Legrand
178S&F Power contactor of 160 Amps, 4 Pole with 2 NO & 2 NC auxilary contacts of coil rating 415 Volt, 50 Hz, including taking out old unserviceable one complete all as specified and as directed. Make : L&T, Cat No.: CS97014; Type : MCX12 or equivalent model from make HAVELLS / BCH /Siemens/Legrand.
179S&F HBC fuse link of rating 630 Amps of breaking capacity 80 KA & rated voltage 415 volt of size 03, DIN type, including taking out old unserviceable one complete all as specified and as directed. Make : Havells, Cat No. IHHCD03630 or equivalent model from make Indo Asian/L&T/Siemens/Legrand.
180S&F HBC fuse link of rating 400 Amps of breaking capacity 80 KA & rated voltage 415 volt of size 02, DIN type, including taking out old unserviceable one complete all as specified and as directed. Make : Havells, Cat No. IHHCD02400 or equivalent model from make Indo Asian/L&T/Siemens/Legrand
181S&F HBC fuse link of rating 250 Amps of breaking capacity of 80 KA & rated voltage 415 volt of size 02, DIN type including taking out old unserviceable one, complete all as specified and as directed. Make : Havells, Cat No.- IHHCD01250 oor equivalent model from make Indo Asian/L&T/Siemens/Legrand
182S&F HBC fuse link of rating 160 Amps of breaking capacity of 80 KA & rated voltage 415 volt of size 01, DIN type including taking out old unserviceable one, complete all as specified and as directed. Make : Havells, Cat No.- IHHCD01160 or equivalent model from make Indo Asian/L&T/Siemens/Legrand
183S&F cam operated rotary selector switch Auto / Manual type complete all as specefied and as directed. MAKE : Kaycee/HPL/L&T/Schneider/BCH
184S&F Voltage Monotoring relay suitable for 63 to125 KVA DG Set including taking down old unserviceable one complete all as specified and as directed. MAKE : Kirloskar/ MRI / Johnson / Crompton Greaves/BCH
185S&F Voltage Monotoring relay suitable for 160 to 320 KVA DG Set including taking down old unserviceable one complete all as specified and as directed. MAKE : Kirloskar/ MRI / Johnson / Crompton Greaves/BCH
186S&F in replacement of fuel / over flow pipe for DG set / diesel driven pump set complete all as specified and as directed.
187M&L for Earthing complete with copper plate electrode 30 cm x 30 cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 mtrsdeep below ground level) with top edge of the platenot less than 1.5 mtrs below normal ground level,connected tocopper strip 20x3 mm as earthing leadby means of bolts, nuts, check nutsand washers of galvanised iron or steel all as shownin electrical plate No 3 in SSR Part I of 2009 connected to earthingtest point all as specified and directed complete withexcavation & earth work, PCC pit in cement concrete type C2 1:3:6 (Using 20mm graded stone aggregate) and 50mm thickRCC cover of size 450X450X50mm in RCC type B-1 1:2:4 (Using 20mm graded stone aggregate) reinforced with and including 8.0 mm dia TMT bar @100mm centre to centre both ways, having suitable handle(10mm MS Rod) 20mm dia GI medium gradewatering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked) for protection of earth leadconductor all as directed and testing on completion complete all as specified and directed.
188M&L for Earthing complete with mild steel galvanised plate electrode of size 60cm x 60cm x 6.0mm buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the platenot less than 1.5m below normal ground level,connected togalvanised iron strip 32 x 6mm as earthing leadby means of bolts, nuts, check nutsand washers of galvanised iron or steel all as shown in Electrical Plate No. 3 in SSR Part-I of 2009, connected to earthing test point all as specified and directed complete including necessary excavation & earth work, PCC pit in cement concrete (1:3:6)type C-2 (Using 40mm graded stone aggregate) and 50mm thickRCC cover of size 450x450x50mm in RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with and including 8.0mm dia TMT bar @ 100mm centre to centre both ways, having suitable handle (10mm MS Rod) 20mm dia GI pipe, medium grade for watering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade, for protection of earth lead conductor including testing complete all as specified and as directed.
189S&F as in repairs selector switch for AMF panel of suitable size complete all as specified and as directed.
190S&F as in repairs LLOP sensor suitable for 40 KVA DG set complete all as specified and as directed. MAKE : VDO/Gems
191S&F as in repairs LLOP sensor suitable for 63 KVA DG set complete all as specified and as directed. MAKE : VDO/Gems
192S&F as in repairs LLOP sensor suitable for 100 KVA DG set complete all as specified and as directed. MAKE : VDO/Gems
193S&F as in repairs LLOP sensor suitable for 125 KVA DG set complete all as specified and as directed. MAKE : VDO/Gems
194S&F as in repairs LLOP sensor suitable for 160 KVA DG set complete all as specified and as directed. MAKE : VDO/Gems
195S&F as in repairs LLOP sensor suitable for 200 KVA DG set complete all as specified and as directed. MAKE : VDO/Gems
196S&F as in repairs LLOP sensor suitable for 250 KVA DG set complete all as specified and as directed. MAKE : VDO/Gems
197S&F as in repairs LLOP sensor suitable for 320 KVA DG set complete all as specified and as directed. MAKE : VDO/Gems
198S&F as in repairs LLOP sensor suitable for 750 KVA DG set complete all as specified and as directed. MAKE : VDO/Gems
199S&F as in repairs water hose pipe suitable for 40 to 100 Amp DG set complete all as specified and as directed.
200S&F as in repairs water hose pipe suitable for 125 to 200 Amp DG set complete all as specified and as directed.
201S&F as in repairs water hose pipe suitable for 250 to 320 Amp DG set complete all as specified and as directed.
202S&F as in repairs coolant reserve box with pipe of suitable size of DG set as existing complete all as specified and as directed.
203S&F as in repairs brass battery terminal connectors with all accessories for DG set battery, complete all as specified and as directed.
204S&F as in repairs controller suitable for 40 to 63 KVA DG set complete all as specified and as directed. MAKE : Power command/ Procom/ Deep sea electronics/ Leypower
205S&F as in repairs controller suitable for 100 to 125 KVA DG set complete all as specified and as directed. MAKE : Power command/ Procom/ Deep sea electronics/ Leypower
206S&F as in repairs controller suitable for 200 to 250 KVA DG set complete all as specified and as directed. MAKE : Power command/ Procom/ Deep sea electronics/ Leypower
207S&F as in repairs controller suitable for 320 KVA DG set complete all as specified and as directed. MAKE : Power command/ Procom/ Deep sea electronics/ Leypower
208S&F as in repairs thermostat valve suitable for 40 to 63 KVA DG set complete all as specified and as directed.
209S&F as in repairs thermostat valve suitable for 100 to 200 KVA DG set complete all as specified and as directed.
210S&F as in repairs magnetic pick up suitable for 40 to 63 KVA DG set complete all as specified and as directed.
211S&F as in repairs magnetic pick up suitable for 100 to 200 KVA DG set complete all as specified and as directed.
212S&F as in repairs magnetic pick up suitable for 200 to 320 KVA DG set complete all as specified and as directed.
213S&F as in repairs centrifugal filter suitable for 160 to 200 KVA DG set complete all as specified and as directed.
214S&F as in repairs centrifugal filter suitable for 250 to 320 KVA DG set complete all as specified and as directed.
215Labour only for major overhaulling of 63 to 125 KVA DG Set including fixing of the following spares, testing and commissioning complete all as specified and as directed. Note : Spares parts to be measured and paid separately.
216Supply only piston of suitable size for 63 to 125 KVA DG Set complete all as specified and as directed.
217Supply only piston ring of suitable size for 63 to 125 KVA DG Set complete all as specified and as directed.
218Supply only CR bearing STD of suitable size for 63 to 125 KVA DG Set complete all as specified and as directed.
219Supply only set of copper washer of suitable size for 63 to 125 KVA DG Set complete all as specified and as directed.
220Supply only set of gasket of suitable size for 63 to 125 KVA DG Set complete all as specified and as directed.
221Supply only cylinder head bolt of suitable size for 63 to 125 KVA DG Set complete all as specified and as directed.
222Supply only CR bearing bolt of suitable size for 63 to 125 KVA DG Set complete all as specified and as directed.
223Supply only valve seal of suitable size for 63 to 125 KVA DG Set complete all as specified and as directed.
224Supply only cyliner head gasket of suitable size for 63 to 125 KVA DG Set complete all as specified and as directed.
225Supply only liner with "O" ring of suitable size for 63 to 125 KVA DG Set complete all as specified and as directed.
226S&F as in repairs motorised change over switch 400 Amp with suitable enclosure to be fixed to wall complete all as specified and as directed. Make : L&T/Legrand / Havells / Indoasian / Schneider
227S&F as in repairs base card for the following DG setcomplete all as specified and as directed:-
228320 KVADG set
229250 KVADG set
230200 KVADG set
231160 KVADG set
232100/125 KVADG set
233S&F as in repairs etectronic governor for the following DG setcomplete all as specified and as directed:-
234320 KVADG set
235250 KVADG set
236200 KVADG set
237S&F as in repairs controller assembly with all accessories for 250 to 320 KVA DG set complete all as specified and as directed.
238S&F as in repairs suppressor, transient with all accessories for 250 to 320 KVA DG setcomplete all as specified and as directed.
239S&F as in repairs module electronic control with all accessories for 250 to 320 KVA DG setcomplete all as specified and as directed.
240S&F as in repairs PVC insulated and FR PVC round sheathed, control copper conductor (flexible), 1100 volt, 2.5 sqmm, 19 core with all accessories complete all as specified and as directed.
241S&F as in repairs with new water pump of 63 to 125 KVA DG Set with all accessories complete all as specified and as directed
242S&F as in repairs with new water pump of 163 to 250 KVA DG Set with all accessories complete all as specified and as directed
243S&F as in repairs control relay with AC coil 10 Ampswith 2 No and 2 NC contact arrangement fixed in repairs, including taking down old unserviceable one complete all as specified and as directed. Make : Havells/L&T/ABB/Schneider/Legrand.
244S&F as in repairs indicator lamp LED type, 220 volt AC (RED/GREEN) for each capacitor showing ON/OFF and including taking down old unserviceable one complete all as specefied and as directed. Make: L&T/SIEMENS/LEGRAND/SCHNEIDER
245S&F as in repairs push button actuator Red / Green and as approved including contact element, including taking down old unserviceable one, suitable as existing at site with contact element NO/NC complete all as specefied and as directed. Make: L&T/SIEMENS/LEGRAND/SCHNEIDER
246S&F as in repairs wiring harness for the following DG setcomplete all as specified and as directed:-
247250 to 320 KVADG set
248100 to 163 KVADG set
249M&L for complete servicing of high mast light of any height and descriptionfor general checking, mechanical parts checking and electrical system maintenance complete all as specified and as directed for the followings :- (a) Checking and repair of head frame of the high mast poles fitted with wire ropes and cables. (b) Checking and repairof gear box for seal leakage. (c) Checking and repair of lift cables for frayed strands (d) Testing and repairing of lowering device and fully operate to fully down position. (e) Repair and maintenance of any mechnical devices as required. (f) Checking and repairing of all electrcial devices. (g) Checking and repair of luminaires box, control gear and junction box nad tightened properly. (h) Checking and reparing of all screws and nuts properly. Note - Major items like gear box and steel wire rope will be measured and paid seperately under relevant items.
250Supply, fixing, testing and commissioning in replacement 3-5 inch double drum with gear box winch complete with motor double gear type, suitable for 30 mtr high mast pole, 3 phase supple, 415 Volt complete with rope and all accessories like wire lock GI thimbles rigging and GI U clamps complete including taking down carefully old unserviceable winch set all as specified and directed. Note- Necessary T&P required for completion of the job is deemed to be included in quoted rate.
251M&L for steel wire rope on High mast light of dia 8mm SS/galvanised IWRC as per IS-2262/02 alongwith suitable size clamps & "U" bolts for holding the high mast bracket at a height of 30 mtr from normal ground levelcomplete all as specified and directed. Note- Necessary T&P required for completion of the job is deemed to be included in quoted rate.
252Material and labour for taking out burnt winding of 3 phase power tool electric motorof high mast fittings from any position, rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning on reinstating complete all as specified and as directed. Note: Quoted rate shall be deemed to be inclusive of any minor spares / parts replaced for successful functionality of the motor
253M&L for ELECTRICAL HOIST CABLES shall be 5 core X 2.5/4.0 sq.mm. round type or 8 core x 2.5 sq.mm. flat type made of strands of plain copper wires, core insulation of PVC based compound, core identification in accordance with VDE 0293 or equivalent, special cold resistant PVC outer sheath, black and flame retardant complete all as specified and as directed.
254S&F as in repair LED aviation light luminaries comprising of alluminium housing with polycarbonate encloser with 302 Nos LED including cable for connection after taking down old unserviceable light fittings, complete all as directed. Make : Bajaj, Cat No. BGAV302 LED or equivalent model from make Philips/Havells/GE/Wipro
255Supply of outdoor stand mounted feeder pillar in repairwith 32A TPN MCB incomer, single dial time switch, 25 Amps TP contactor for the automatic switching of luminaries, power tool control with 2 No 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals complete all as specified and as directed.
256M&L for painting of LT Termac structure tower of any height and any size, any pattern with one coat of aluminium paint over one coat of red oxide primer in full length of the pole and marking the pole numbering with serially complete all as specified and as directed.
257Supply, fixing, testing and comissioning as in repairs ofstreet light panel IP-54 suitable for 415V AC, 3 Phase system complete with following accessories and including complete including wiring and other accessories as per manufacturer"s design complete all as specified and as directed. (i) AC-3duty 3 pole power contactor, 32 amps-01 Nos. (ii) TPN MCB 40Amps(10KA)-01 No. (iii) Selector switch (Auto Manual)01 No. (iv) Indicator lamp (v) Digital time switch 24Hrs-01No. Make : Havells, Cat No. IHXTS 03060 or equivalent model from make INDO ASIAN/L&T/LEGRAND/SIEMENS
258Disconnecting/Taking down led street light/termac light/aviation light and repair / checking and identifying of faulty spares wirings, cleaning of fittings, cover, etc. and re-assembling the same after repair, testing and re-fixing in original position and reconnecting with the electrical line complete all as specified and as directed. NOTE : Spare parts shall be measured and paid separately under relevent items here in after.
259S&F as in repair 300 watt LED flood light fitting luminaries with high pressure die cast housing acting as heat sink in order to ensure better performance of the luminaries, complete including clamp, nuts, bolts and other accessories for fixing, including cable for connection after taking down old unserviceable light fittings from pole complete all as specified and as directed. Make : Crompton, Cat No-CFS-501-300-57-60D-SL-GL-NGG or equivalent model from make of Philips/GE/WIPRO/ HAVELLS
260All as per Serial item No. 97 here-in-before but of 250 Watt Make : Crompton, Cat No-CFS-506-250-57-60D-SL-GL-NGG or equivalent model from make of Philips/GE/WIPRO/HAVELLS.
261All as per Serial item No. 97 here-in-before but of200 Watt. Make : Crompton, Cat No. CFS-501-200-57-60D-SL-GL-NGG or equivalent model from make of Philips/GE/WIPRO/ HAVELLS
262All as per Serial item No. 97 here-in-before but of 150 Watt. Make : Crompton, Cat No. -CFS-501-150-57-60D-SL-GL-NGG or equivalent model from make of Philips/GE/WIPRO/ HAVELLS
263All as per Serial item No. 97 here-in-before but of 120 Watt Make : Crompton, Cat No. TFS-504-120-57-60D-SL-GL-NSG or equivalent model from make of Philips/GE/WIPRO/ HAVELLS
264S&F as in repairs LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. Make : Crompton/Philips/GE/WIPRO/HAVELLS
265All as per Serial item No. 102 here-in-before including makes but of60 Watt.
266All as per Serial item No. 102 here-in-before including makes but of 70 Watt.
267All as per Serial item No. 102 here-in-before including makes but of90 Watt.
268All as per Serial item No. 16 here-in-before including makes but of 100 Watt.
269All as per Serial item No. 102 here-in-before including makes but of 120 Watt.
270S&F as in repairs 100 Watt highbay light luminaire with high pressure die cast housing acting as heat sink in order to ensure better performance of the luminaires after and including taking down old unserviceable light fittings complete all as specified and as directed. Make : Crompton, Cat No-LHB11-100-CDL/60-M or equivalent model from make of Philips/GE/WIPRO/ HAVELLS
271S&F as in repairs Cable Junction Box of size200x160x98mm, made out of thermoplastic having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 -02 No & M-25 -01 No) fixed on poles with aluminium clamps of size 25x3mm, nuts, bolts, washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed. Make : HENSEL, Cat No. K-9250 or equivalent model from make SPELSBERG/Sintex/C&S Electric Ltd.
272M&L as in repairs for PVC insulated two core 2.5 sq.mm multistrand aluminium conductor for connection of security light from Junction Box to security light complete all as specified and as directed. Make : Finolex/Havells/Asian Cable/KEI/RR Kable Ltd.
273M&L as in repair for PVC insulated two core 4 sq.mm multistrand aluminium conductor for connection of security light from Junction Box to security light complete all as specified and as directed. Make : Finolex/Havells/Asian Cable/KEI/RR Kable Ltd.
274M&L as in repairs for PVC insulated two core 6 sq.mm multistrand aluminium conductor for connection of security light from Junction Box to security light complete all as specified and as directed. Make : Finolex/Havells/Asian Cable/KEI/RR Kable Ltd.
275Excavating in trenches not exc. 1.50m wide and not exc. 1.50m in depth and taking out and laying of cables, etc. and getting out in soft/loose soil complete all as specified and as directed.
276M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil complete all as specified and as directed.
277M&L for removing excavated materials/soils not exc. 50mand depositing where directed at a level not exc. 1.50m above the starting point in soil complete all as specified and as directed.
278Taking down/out unserviceable or serviceable UG cables of any cross sectional area and connections including bricks, GI pipes, etc. of any descriptions, laid in trenches and/or fixing with walls/poles including segregating of serviceable materials viz bricks, cables, GI pipes, etc. and keep in safe custody for re-use complete all as specified and as directed. NOTE : Earth Work shall be measured and paid separately.
279M&L for relaying and rerouting of serviceable UG cable of any size and any type of cable up to 35 sq.mm , 2 core, 3.5 core & 4 core size all as specified and as directed. Note : Excavation, sand, bricks and connected items measured and paid separately.
280Laying only old serviceable bricks laid flat equal to width of bricks, perpendicular to UG cable over the dry sand cushioning for cable protection complete all as specified and as directed .
281M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness complete all as specified and as directed. NOTE : For the purpose of payment, punned thick-ness of sand cushioning only shall be measured and paid.
282S&F sub-class "B" bricks, well burnt, laid breadth-wise along the length of cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and as directed.
283M&L for cable in trenches or passing through pipe, XLPE insulated,heavy duty,galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 25 sq.mm 4 core complete all as specified and as directed. Make : Finolex/Havells/Asian Cable/KEI/RR Kable Ltd.
284All as per Serial item No. 121 here-in-before but of 16 sq.mm 4 core. Make : Finolex/Havells/Asian Cable/KEI/RR Kable Ltd.
285S&F as in repair on pole street light bracket fabricated out of GI tubing light grade 40mm bore bend to the shape as directed and of length 1.0m complete with mounting MS clamp of flat iron size 25x5mm of suitable length 02 pairs including nut bolts, etc. of suitable size and painting to MS clamp with two coats of aluminium paints over a coat of red oxide metal primer complete all as specified and as directed.
286S&F as in repairs polycarbonate unbreakable white globe doom of 8 inch dia in existing garden light pole complete all as specified and as directed. Make : Havells/Anchor/Legrand/Schneider/L&T
287S&F as in repairs lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and as directed. Make : Havells/Anchor/Legrand/Schneider/L&T
288S&F 7 watt LED bulb B-22 type complete all as specified and as directed. Make : Philips/Wipro/GE/Crompton
289S&F as in repairs GI pipe 40mm bore (dia) ‘light grade’ for protection of UG cable, laid in floors/ road crossing, fixing to pole with MS clamps, nuts, bolts, etc. complete all as specified and as directed.
290Labour only for horizontal boring for passingprotection pipe up to 40mm bore (dia), under road/foot path, not exc. 10m in a single length complete all as specified and as directed. Note : Pipe to be measured and paid separately.
291M&L for PCC (1:2:4) type B-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete for road complete all as specified and as directed.
292M&L for PCC (1:2:4) type B-1 (using 20mm graded broken stone aggregate) as in coping and footing for poles, etc including necessary form work complete all as specified and as directed.
293M&L for painting of LT electric pole, steel tubular swaged pole (8.5 meter to 9 meter long) of any size, any pattern with one coat of aluminium paint over a coat of red oxide primer in full length of the pole and marking the pole with black and yellow strip (upto to 1 metre length, 1 metre height of PCC coping) alternatively including numbering the pole serially complete all as specified and as directed.
294S&F 40mm dia, light density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors, etc. complete all as specified and as directed .
295S&F as in replacement of steel tubing of size 25mm dia, light grade with all fittings, laid in trenches/wall for protection of cablesfixing on poles/on wall complete all as specified and as directed.
296M&L for PVC sheathed copper cable of1.5 sq.mm, 3 core for street light connection including taking down old unserviceable PVC insulatedaluminium conductor cablefrom steel pole/PCC pole /Junction box, etc. complete all as specified and as directed.
297Material and labour for Earthing complete with GI earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below ground level with top edge of plate not less than 1.5m below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanized iron as steel,protected by galvanized iron pipe 40mm bore (medium grade) complete allas directed including cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in Electrical Plate No. 3 of SSR Part-I including testing on completion all complete as specified and as directed. NOTE : GI wire upto 7.5m including testing consider in this item.
298M&L Straight Through Cable Joint Kit including Jointing Materials for making Joints of UG Electric cable 1100 volt grade, heavy duty with PVC/XLPE insulated Aluminium Stranded Conductor, Nominal Cross-Sectional area 25 Sq.mm to 50 Sqmm, 3½/4 Core and Testing complete all as specified and as directed. Make : M-Seal/Cab-Seal/Denson/Raychem/Birla 3M
299S&F aluminum lugs of the following sizes : - Make : Dowells/TVS/Dehmy/Daystar/Jaico/BSE
300(a) 10 sq mm
301(b) 16 sq mm
302(c) 25 sq mm
303(d) 35 sq mm
304(e) 50 sq mm
305M&L for mild steel nuts, bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n. exc. 5cm long and diameter of neck 5-10mm complete all as specified and as directed.
306M&L forsaddle clamp/fastener size up to 40mm suitable for fixing of UG cable onto the perimeter wall surface and attached with a suitable screw, bolt, or pin, etc. complete all as specified and directed.
307M&L for plastic emulsion painting with two coats on concrete/plaster sufraces (Pole coping) of any description of as directed over 10cm girth or width complete all as specified and as directed.
308M&L for straight through cable joint kit including jointing materials for making Joints of UG electric cable 1100 volt grade, heavy duty with PVC/XLPE insulated aluminium stranded conductor, nominal cross-sectional area 70 sq.mm to 95 Sq.mm, 3½/4 Core and testing complete all as specified and as directed. Make : M-Seal/Cab-Seal/Denson/Raychem/Birla 3M
309M&L for straight through cable joint kit including jointing materials for making joints of UG electric cable 1100 volts grade, heavy duty with PVC/XLPE insulated aluminium stranded conductor, nominal cross-sectional area 120 Sq.mm to 185 Sq.mm, 3½/4 Core and Testing complete all as specified and as directed. Make : M-Seal/Cab-Seal/Denson/Raychem/Birla/3M
310S&F as in repairs power contactor for street light panel 100A AC1 (4NO),220 volts, 50 Hz WB including taking down old unserviceable power contactor complet all as specified and as directed. Make : Schneider,Cat No. LC1E65008*N or equivalent model from make T&T/Legrand/ Havells NOTE : The contract sum shall be derieved by deducting the amount shown in Schedule of Credit attached to this tender from total amount of Schedule "A"/BOQ.
Disclaimer :