Tender For Repair/Maint Of Ro Plant And Water Supply Pipe Lines In Kwc Area Under Ge I Rnd Delhi, delhi-Delhi

Military Engineer Services-MES has published Tender For Repair/Maint Of Ro Plant And Water Supply Pipe Lines In Kwc Area Under Ge I Rnd Delhi. Submission Date for this Tender is 17-01-2024. Pipe Laying Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

41215766
Corrigendum : Tender For Repair/Maint Of Ro Plant And Water Supply Pipe Lines In Kwc Area Under Ge I Rnd Delhi
Open Tender
Indian
Delhi
delhi
17-01-2024

Tender Details

Repair/Maint Of Ro Plant And Water Supply Pipe Lines In Kwc Area Under Ge I Rnd Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Dec-2023 Corrigendum01 BOQ 10-01-2024
2 10-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-01-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 97000.0 /-
Tender Value
INR 48.46 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR/MAINT OF RO PLANT AND WATER SUPPLY PIPE LINES IN KWC AREAUNDER GE I RND DELHI
Sl. No. Item Description
1M&L for openingof the Filter media tank and remove the existing media and Sand from the tank and clean the tank properly and last wash with Hypo/ bleaching solution complete all as specified and directed
2Supply and pouring in repair natural gravels of different sizes (5mm-40mm) 25 Kg each packas per requirement complete all as specified and directed
3All as per ser item No. 2.00 above but selex media 25 Kg each packas per requirement.
4All as per ser item No. 2.00 above but coarse sand media sizes as per requirement.
5All as per ser item No. 2.00 above but Carbon media 25Kg each pack as per requirement.
6S&F in repair stainless steeltubing (SS-304 grade) 80mm dia heavy duty with all accessories /joints/ modification as per site requirement complete all as specified and directed.
7All as per ser item No. 6.00 above but 50 mm dia.
8All as per ser item No. 6.00 above but 40 mm dia.
9S&F in repair CI 50mm bore hand operated butterfly valveincluding gasket & flange complete all as specified and directed.
10S&F in repairCI 80mm bore hand operated butterfly valve including gasket & flange complete all as specified and directed.
11S&F in repair CI 100mm bore hand operated butterfly valveincluding gasket flange completeall as specified and directed.
12S&F in repair CI 150mm bore hand operated butterfly valveincluding gasket & flange completeall as specified and directed.
13S&F in repairCPVC ball valve of 25mm dia brass threaded with all fitting and fixtures complete all as specified and directed.
14All as per ser item No. 13.00 above but 40mm dia.
15All as per ser item No. 13.00 above but 50mm dia.
16S&F in repair Stainless steel longball valve(SS-304 grade) 50mm dia heavy duty with all accessories /joints/ modification as per site requirement complete all as specified and directed
17All as per ser item No. 16.00 above but 80 mm dia.
18S&F in repair CPVC long length ball valve 50mm dia with all fittings & fixtures complete all as specified and directed.
19All as per ser item No. 18.00 above but 80 mm dia.
20All as per ser item No. 18.00 above but 100 mm dia.
21S&F in repairNon Return Valve 50 mm dia with all acessories/joints/ modification as per site requirement complete all as specified and directed
22All as per ser item No. 21.00 above but 80 mm dia.
23All as per ser item No. 21.00 above but 100 mm dia.
24S&F in repairmembrane of size 80mmx40mm complete all as specified and directed
25S&F in repair Cartridge 20"X 4.5 "dia for PP filter water treatment plant complete all as specified and directed.
26All as per ser item No. 25.00 above but 20"X 4.5 "diafor wound cartriagewater treatment plant complete all as specified and directed
27All as per ser item No. 25.00 above but 30"X 4.5 "dia for PP filter water treatment plant complete all as specified and directed
28All as per ser item No. 25.00 above but 30"X 4.5 "dia forwound cartriagewater treatment plant.
29S&F in repairCPVC pipe outer dia25mmSDR II with all fitting and fixtures (CPVC SDR-II)and joints complete all as specified and directed
30All as per ser item No. 29.00 above but40 mm dia.
31All as per ser item No. 29.00 above but 50 mm dia.
32All as per ser item No. 29.00 above but 80 mm dia.
33All as per ser item No. 29.00 above but100 mm dia.
34Opening of Softner tank and remove all the raisen & gravel, mud and wash with the Hypo/ bleaching solution and fill the new gravels not less than 200 kg and raisen not less than 100 cubic feet after washing/cleaning complete all as specified and directed
35Supply only industrial salt 50 kg each pack for water softner tank complete all as specified and directed
36S&F in repairfoot valve CPVC 100 mm complete all as specified and directed
37S&F in repairfoot valve CPVC 80 mm complete all as specified and directed
38M&L for servicing automatic panelwith replacement of existing wiringas per existing materialand upload of software for working of all RO system in automode complete all as specified and directed.
39S&F in repairchemical Dozing pump for RO plant complete all as specified and directed.
40S&F in repair water meter of size 80 mm for RO plant complete all as specified and directed.
41M&L in repair chemical Dozer pipe for RO plant complete all as specified and directed.
42S&F rolled Mild Steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), Fe410- W(Gde-E-250) quality- A complete all as specified and as directed.
43Supply only sodium hypochloride (liquid bleach) 10 % (20 ltr each pack)
44Supply only sodium meta bi-sulphite (25 Kg each pack).
45Supply only citric acid monohydrate (25 Kg each pack)
46Supply only light soda ash (25 Kg each pack)
47Supply only CX-002 RO Antiscalant Solution (25 kg each pack)
48M&L for painting with two coat of synthetic enamel paint over a coat of red oxide primer on new steel surface including preparation of surfacecomplete all as specified and directed.
49S&F in repairPVC copper conductorunsheathed 6 Sqmm single corecable three Nos including flexible PVC conduit medium grade of size 25 mm dia complete all as specified and directed.
50S&F in repair of PVC copper conductor unsheathed 10 Sqmm single core cable three Nos including flexible PVC conduit medium grade of size 40 mm dia complete all as specified and directed. Note for item No 49 & 50 : Three run of cables & one run of PVC conduit shall be measured as one unit i.e.
51Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron strip of 32mmx6mm by means of Copper nuts, bolts and washers.Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a)GI strip of size 32mm x 6mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel shall be properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
52M&L for Lead wool complete all as specified and directed.
53M&L in repair mild steel Nuts ,Bolts and Washers 25 to 150 mm long of 6 to 20 mm dia complete all as specified and directed.
54M& L in repairGland dori as per requirement & directed.
55S&F in repair Digital ammeter of existing size 100mm (Square type) and connecting up & testing complete all as specified and directed.
56S&F in repairDigital Voltmeter of existing size 100mm (Square type) and connecting up & testingcomplete all as specified and directed.
57S&F in repairElectronic timer type ET-100, 9 to 30 sec, 415V suitable for star-delta/DOL starter upto 20 HP capacity complete all as specified and directed.
58S&F in repairRelay of current range 10 to 16amps, 415 volts suitable for mounted on ML-1.5 and ML-3 Contactors complete all as specified and directed.
59S&F in repairRelay of current range 28 to 42amps, 415 volts suitable for mounted on ML-2 and ML-3 Contactors complete all as specified and directed.
60S&F in repairPressure gauge of capacity 0 to 6 kg/cm² complete all as specifiedanddirected
61S&F in repairPVC float valve with epoxy coated aluminium rod and high density ballofsizes 15 mm bore complete all as specified and directed.
62S&F in repair PVC float valve with epoxy coated aluminium rod and high density ballofsizes 20 mm bore complete all as specified and directed.
63S&F in repair PVC float valve with epoxy coated aluminium rod and high density ballofsizes 25 mm bore complete all as specified and directed.
64S&F in repairPVC float valve with epoxy coated aluminium rod and high density ballofsizes 40 mm bore complete all as specified and directed.
65S&F in repair PVC float valve with epoxy coated aluminium rod and high density ballofsizes 50 mm bore complete all as specified and directed.
66S&F in repairgun metal gatevalve with iron wheel head screwedboth ends for iron pipe , ISI marked , as per IS : 778 of size 15 mm bore complete all as specified and directed.
67S&F in repairgun metal gatevalve with iron wheel head screwedboth ends for iron pipe , ISI marked , as per IS : 778 of size 20 mm bore complete all as specified and directed.
68S&F in repair gun metal gatevalve with iron wheel head screwedboth ends for iron pipe , ISI marked , as per IS : 778 of size 25 mm bore complete all as specified and directed.
69S&F in repair gun metal gatevalve with iron wheel head screwedboth ends for iron pipe , ISI marked , as per IS : 778 of size 40 mm bore complete all as specified and directed.
70S&F in repairgun metal gatevalve with iron wheel head screwedboth ends for iron pipe , ISI marked , as per IS : 778 of size 50 mm bore complete all as specified and directed.
71Testing of drinking water being collected from local source (bore wells/sump /shallow wells) of KWC Area & Metcalfe House Area underGE(I) R&D Delhi and submission of detailed test report to the office of Engr-in-Charge. (a) Collection of water from different sources of water ie. Sump, bore wells & shallow well in a sterilized bottle and testing in Govt Approved laboratory as mentioned in specification. (b )Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, PH valve TDS total hardness iron, chloride, fluride and residual free chlorine and Bacteriological total coil from organisms per 100 ml (MPN) and E coli in 100 ml) and to this office with specific recommendation regarding suitabiulity of water for drinking purpose. Note:- Rate Quoated shall deemed to be included for :- (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source (sump, bore & shallow wells) (iii) Testing should be carried out from Govt approved lab.
72Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out completeall as specified and as directed.
73All as per item No. 72.00 above but in hard/dense soil including road cutting ect.
74Returning,fillingin and including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
75Removing surplus soil to a distance exceeding 1.5Km but not exc 5km and depositing where directed at a level n.exc 1.5mabove the starting point complete all as specified and as directed.
76M&L in replacement for burning out lead joint in any position including removing old lead joint and making new lead jointby using retrieved lead and new lead approx 700gms for CI pipe of 150mm bore complete all as specified and directed.
77M&L in replacement for burning out lead joint in any position including removing old lead joint and making new lead jointby using retrived lead and new lead minimum 500 gms for CI pipe of 100mm bore complete all as specified and directed.
78M&L in replacement for burning out lead joint in any position including removing old lead joint and making new lead joint by using retrived lead and new lead minimum 400 gms for CI pipe of 80mm bore complete all as specified and directed.
79Isolate the water supply by operating the sluice valve at main pump house and empty the underground water sump by using pumps of suitable capacity, after emptying the sump cutting /opening the existing rusted/damaged foot valve. S&F new foot valve of size 150mm bore, Flanged/ threaded type, IS: 4038, PN 0.2 with strainer of cast iron IS 210 Gr FG 200 and joining with the existing suction pipe line including all connected items like nuts, bolts, washers, flanges etc complete all as specified and directed.
80All as per item No. 79.00 above but of size 100mm bore
81All as per item No. 79.00 above but of size 80mm bore
82Isolate the water supply from Main pump house or by operating sluice valve /gate valve.T&P for opening old unserviceable non return valve by unsrewing the nut bolts, washer, flanges and S&F CIDF swing type non return valve of size 150mm bore as per IS-5312 (part 1&2) PN 1.60 CI body, door/bronze to rubber ring /SS 410 hinge pin alongwith neccessary hardware, packing material like nuts, bolts, washers, flanges etc complete for the following sizes complete all as specified and directed.
83All as per item No. 82.00 above but of size 100mm bore.
84All as per item No. 82.00 above but of size 80mm bore.
85S&F in repair automatic star-delta motor starter in sheet metal enclosure type ML suitable for 3 phase electric motor of capacity upto 30 HP, 3 phase 415V with relay range 16-25 Amps complete all as specified and directed.
86S&F in repairpower contactor ofcurrent rating upto 60 amps and standard coil voltage240v, 50Hz type ML-3of aux contact (2 NO + 2 NC) including reconnection of cable complete all as specified and directed.
87All as per itemNo 123.00 above but ofcurrent rating upto 125 Amps and standard coil voltage240v, 50Hz type ML-6of aux contact (2 NO + 2 NC) including reconnection of cable.
88S&F in repair General Purpose Load Changeover Switch Confirms to IS:13947 (Part I & III) Onload Changeover Switch - AC 23 (side handle) in sheet enclosure, 415, 4 pole of capacity 400 Amps complete all as specified and directed.
89S&F in repair6 Sqmm PVC cable unsheathed multistandarded copper conductorincluding 25mm dia metallicconduit complete all as specified and directed.
90All as per item srl No 89.00 above but of cable size 10 sqmm
91All as per item srl No 89.00 above but of cable size 16 sqmm Note for item No 89.00 to 91.00 :- One RM of cable & one RM of conduit shall be measured as one unit(RM)
92M&L for brick work in cement mortar 1:6 using sub class "B" brick straight or curved on plain not exceeding 6M mean radius including demolition of old unserviceablebrick work complete all as specified and directed
93M&L for 15mm thick cement plaster in CM 1:4 on brick/concrete surface etc finished even and smooth without using extra cement complete all as specified and directed.
94M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate)in roof kerbs or mud stops, rounded or chamfered on edges including demolition of old existing surface complete all as specified and directed.
95M&L for PCC 1:4:8 Type D2 (using 40 mm graded crushed stone aggregate)foundations, filling and mass concreteincluding demolition of old existing surface complete all as specified and directed.
96S&F in replacement of motor of domestic RO of capacity 100 GPD complete all as specified and directed.
97S&F in replacement of SV-SLX- of domestic RO complete all as specified and directed.
98S&F in replacement of Membrane ECO of domestic ROcomplete all as specified and directed.
99S&F in replacement ofInline of domestic ROcomplete all as specified and directed.
100S&Fin replacement of UV LED of domestic ROcomplete all as specified and directed.
101S&F in replacement of UV barrel of domestic ROcomplete all as specified and directed.
102S&F in replacement of SMPS 24 of domesticROcomplete all as specified and directed.
103S&F in replacement of Float Valve of domestic ROcomplete all as specified and directed.
104S&F in replacement of SPUN Filter of domestic ROcomplete all as specified and directed.
105S&F in replacement of Outer Bowl of domestic ROcomplete all as specified and directed.
106S&F in replacement of Water TAP of domestic ROcomplete all as specified and directed.
107S&F in replacement of elbow of domestic ROcomplete all as specified and directed.
108S&F in replacement of Pipe (90 mtr) of domestic ROcomplete all as specified and directed.
109S&F in replacement of Membrane Housing of domestic ROcomplete all as specified and directed.
110S&F in replacement of Motor 150 GDP Industrial RO of capacity 25 ltrcomplete all as specified and directed.
111S&F in replacement of HPS Industrial RO of capacity 25 ltrcomplete all as specified and directed.
112S&F in replacement of NRV Industrial RO of capacity 25 ltrcomplete all as specified and directed.
113S&F in replacement of SvSLX 02 (Qty) Industrial RO of capacity 25 ltrcomplete all as specified and directed.
114S&F in replacement of Membrane 02 No Industrial RO of capacity 25 ltrcomplete all as specified and directed.
115S&F in replacement of Spun10" filter Industrial RO of capacity 25 ltrcomplete all as specified and directed.
116S&F in replacement of CTO 10" Industrial RO of capacity 25 ltrcomplete all as specified and directed.
117S&F in replacement of GAC 10" Industrial RO of capacity 25 ltrcomplete all as specified and directed.
118S&F in replacement of elbow 3/8"" (6Qty) Industrial RO of capacity 25 ltrcomplete all as specified and directed.
119S&F in replacement of SMPS 24 V (3 amp) Industrial RO of capacity 25 ltrcomplete all as specified and directed.
120S&F in replacement of Inline Industrial RO of capacity 25 ltrcomplete all as specified and directed.
121S&F in replacement of Bowl (03 Qty) Industrial RO of capacity 25 ltrcomplete all as specified and directed.
122S&F in repairmembrane of size 40mmx40mm complete all as specified and directed
123S& F in replacement of Motor 150 GDP (02 Qty) Industrial RO of capacity 50 ltrcomplete all as specified and directed.
124S&F in replacement of SPUN 20" Industrial RO of capacity 50 ltrcomplete all as specified and directed.
125S&F in replacement of CTO 20" Industrial RO of capacity 50 ltrcomplete all as specified and directed.
126S&F in replacement of GAC 20" Industrial RO of capacity 50 ltrcomplete all as specified and directed.
127S&F in replacement of 20" Bowl (03 Qty) Industrial RO of capacity 50 ltrcomplete all as specified and directed.
128S&F in replacement of SV SLX (04 Qty) Industrial RO of capacity 50 ltrcomplete all as specified and directed.
129S&F in replacement of Membrane ECO (04 Qty) Industrial RO of capacity 50 ltrcomplete all as specified and directed.
130S&F in replacement of 3/8"" elbow (10 Qty) Industrial RO of capacity 50 ltrcomplete all as specified and directed.
131S&F in replacement of SMPS (03 AMP) Industrial RO of capacity 50 ltrcomplete all as specified and directed.
132S&Fin replacement of HPS Industrial RO of capacity 50 ltrcomplete all as specified and directed.
133S&F in replacement of NRV Industrial RO of capacity 50 ltrcomplete all as specified and directed.
134Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric Centrifugal/Monoblock/High pressure motor ofcapacitiesupto 15 HP from base plate of pump set after opening the nuts, bolts etc and transporting the motor to workshop for repair and back, re-installed after repair including testing complete all as specified and as directed .
135All as per item No 134.00 above but of capacity more than 15-30 HP
136Opening the electric Centrifugal/Monoblock/High pressure motor ofcapacity upto 15 HP including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge ,weight etc. including all other insulating material to make it functionalcomplete all as specified and as directed . Note:- Copper winding wire of approprioate guage will be measured in supply only
137All as per item No 136.00 above but of capacity more than 15-30 HP
138Supply only super enamelled copper winding wire of appropriate gauge suitable upto 100 HP capacitycentrifugal pump sets.
139Disconnecting and De-coupling the Centrifugal/Monoblock/High pressure pump ofcapacity uptp 15 HP from foundation after opening /cutting the rustednuts, bolts etc including transporting the pump to workshop for repairand back, re-installed at existing position after repair and providing new MS nuts, bolts,packing flange etcincluding testing complete all as specified and as directed.
140All as per item No 139.00 above but of capacity more than 15-30 HP
141Opening the Centrifugal/Monoblock/High pressure pump ofcapacity, upto 15 HP repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position complete all as specified and as directed. Note:-All Spare Parts required to make pump fully functional is deemed to be included in above quoted rates.
142All as per item No 141.00 above but of capacity more than 15-30 HP
143S&F in replacement GI pipe medium grade ISI marked including all new fittings in trenches/ wall/ floor of sizes 15mm bore complete all as specified and directed.
144All as per item No 143.00 above but 20 mm bore.
145All as per item No 143.00 above but 25 mm bore.
146All as per item No 143.00 above but 40 mm bore.
147All as per item No 143.00 above but 50 mm bore.
148All as per item No 143.00 above but 80 mm bore.
149All as per item No 143.00 above but 100 mm bore.
150Supplying, Laying, jointing, testing and commmisioning in replacement of DI Pipe of 150 mm bore size, with spigot and socketed ends centrifugally castClass K-7 Push on joint confirming to IS 8329laid in trenches complete all as specified and directed.
151Supplying, Laying, jointing, testing and commmisioning in replacement of DI Pipe of 100 mm bore size, with spigot and socketed ends centrifugally castClass K-7 Push on joint confirming to IS 8329laid in trenches complete all as specified and directed.
152Supplying, Laying, jointing, testing and commmisioning in replacement of DI Pipe of 80 mm bore size, with spigot and socketed ends centrifugally castClass K-7 Push on joint confirming to IS 8329laid in trenches complete all as specified and directed.
153M&L in replacement DI fittings for spigot/socket pipes such as bends of any radious and angle, collars, tapers, tail pieces, Tee pieces, Caps and plugs suitable upto 150 mm bore dia all socketed or socket and spigot or side flanged complete all as specified and directed.
154Material and labour in replacement for Rubber Gasket Joint (tyton joint)including jointingmaterial for DI/CI pipe of size 150 mm bore, complete all as specified and directed.
155Supplying, laying jointing testing in replacementMS pipe,of dia 80 mm Heavy duty class"C" confirming to IS - 1239 of undermentioned sizes, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connected out-going water mains, complete all as specified and directed. (Note : Welded flanges will be measured and paid seperately.)
156Supplying, laying jointing testing in replacement MS pipe,of dia 100 mm Heavy duty class"C" confirming to IS - 1239 of undermentioned sizes, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connected out-going water mains, complete all as specified and directed. (Note : Welded flanges will be measured and paid seperately.)
157Supplying, laying jointing testing in replacement MS pipe,of dia 150 mm Heavy duty class"C" confirming to IS - 1239 of undermentioned sizes, laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header and to connected out-going water mains, complete all as specified and directed. (Note : Welded flanges will be measured and paid seperately.)
158Supply and fixing welded to flanges on ends for MS pipe of dia 80 mm,flange not less than 15m thick, as specified and directed.
159Supply and fixing welded to flanges on ends for MS pipe of dia 100 mm,flange not less than 15m thick, as specified and directed.
160Supply and fixing welded to flanges on ends for MS pipe of dia 150 mm,flange not less than 15m thick, as specified and directed.
161M&L Joints with rubber or fibre board gasket of sizes 80 mmcomplete with nut,bolt and double washers, complete all as specified and directed.
162M&L Joints with rubber or fibre board gasket of sizes 100 mmcomplete with nut,bolt and double washers, complete all as specified and directed.
163Supplying & Fixing ,in replacement of cast iron Sluice Valveof dia 50 mm ISI marked(PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed.
164Supplying & Fixing ,in replacement of cast iron Sluice Valveof dia 80 mm ISI marked(PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed.
165Supplying & Fixing in replacement of cast iron Sluice Valveof dia 100 mm ISI marked(PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed.
166Supplying & Fixing , in replacement of cast iron Sluice Valveof dia 150 mm ISI marked(PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed.
167Supplying & Fixing , in replacement of cast iron Sluice Valveof dia 200 mm ISI marked(PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed.
168Supply and fixingin replacement CI Non return Valve of dia 50 mmwith GM seat, PN-1.0 ISI mark, includingflange joints such as packing, nut and boltsetc.
169Supply and fixingin replacement CI Non return Valve of dia 80 mmwith GM seat, PN-1.0 ISI mark, includingflange joints such as packing, nut and bolts etc
170Supply and fixingin replacement CI Non return Valve of dia 100 mmwith GM seat, PN-1.0 ISI mark, includingflange joints such as packing, nut and bolts etc
171Supply and fixing in replacement CI Non return Valve of dia 150 mmwith GM seat, PN-1.0 ISI mark, includingflange joints such as packing, nut and bolts etc etc.
172Supply and fixing in replacement CI Non return Valve of dia 200 mmwith GM seat, PN-1.0 ISI mark, includingflange joints such as packing, nut and bolts etc etc.
173Supplying and fixingin replacement CI foot valve flanged type of dia 80 mm with strainer confirming to IS:4038 with flanged ends of following size complete all as specified and directed.
174Supplying and fixingin replacement CI foot valve flanged type of dia 100 mm with strainer confirming to IS:4038 with flanged ends of following size complete all as specified and directed.
175Supplying and fixingin replacement CI foot valve flanged type of dia 150 mm with strainer confirming to IS:4038 with flanged ends of following size complete all as specified and directed.
176Labour only for cutting of existing CI / DI pipe of dia 80 mm for insertion of CI specials /valvesetc. all as required including dewatering of lekage water all as required .
177Labour only for cutting of existing CI / DI pipe of dia 100 mm for insertion of CI specials /valvesetc. all as required including dewatering of lekage water all as required .
178Labour only for cutting of existing CI / DI pipe of dia 150 mm for insertion of CI specials /valvesetc. all as required including dewatering of lekage water all as required .
179S&F in replacement flanged water meter woltman type of dia 50 mm including gasket, nut,bolt & double washer as per IS 779, IS 6784, and ISO 4064.
180S&F in replacement flanged water meter woltman type of dia 80 mm including gasket, nut,bolt & double washer as per IS 779, IS 6784, and ISO 4064.
181S&F in replacement flanged water meter woltman type of dia 100 mm including gasket, nut,bolt & double washer as per IS 779, IS 6784, and ISO 4064.
182S&F in replacement flanged water meter woltman type of dia 150 mmincluding gasket, nut,bolt & double washer as per IS 779, IS 6784, and ISO 4064.
183Supply and fix in replacement Strainer Y type conforming to IS, size 80 mm (3”) dia, complete all as specified and directed
184Supply and fixin replacement Strainer Y type conforming to IS, size 100 mm (4”) dia, complete all as specified and directed
185Supply and fixin replacement Strainer Y type conforming to IS, size 150 mm (6”) dia, complete all as specified and directed
186S&F in repair of mild steel work MS sheet, angle iron, flat iron etc including cutting welding etc complete all as specified and directed
187S&F in replacement of PVC water tank triple layered of capacity 2000 ltrs cyliindrical verical with closed hop) including connection inlet- outlet, air vent pipe, complete all as specified and directed
188All as per item Srl No. 187.00 but 3000 ltrs capacity.
189All as per item Srl No.187.00 but 5000 ltrs capacity.
190All as per item Srl No.187.00 but 10,000 ltrs capacity.
191M&L for bocky system under path/road to pass the GI/CI/DI Pipes upto 150 mm dia manually, complete all as specified and directed.
192Supply and fixingin replacement 3 pole power contactor type ML-1.5, 415 Volts, 50 HZ range 25 Amps complete all as specified and as directed.
193Supply and fixingin replacement 3 pole power contactor type ML-2, 32 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
194Supply and fixingin replacement 3 pole power contactor type ML-3, 40 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
195Supply and fixingin replacement 3 pole power contactor type ML-4, 70 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
196Supply and fixingin replacement 3 pole power contactor type ML-6,110 Amps,415 Volts, 50 HZ complete all as specified and as directed.
197S & F in replacement of Bimetal over load replay type ML 1.5, starter type MNX, relay range 14-23 Amp complete all as specified and as directed.
198S & F in replacement of Bimetal over load relay typeML 2, starter type MNX, relay range 20-32 Amps complete all as specified and as directed.
199S & F in replacement of Bimetal over load relay typeML 3, starter type MNX, relay range 28-42 Amps complete all as specified and as directed.
200S & F in replacement of Bimetal over load relay typeML 4/6, starter type MNX, relay range 45-75 Amps complete all as specified and as directed.
201S & F in replacement of Bimetal over load relay typeML 5, starter type MN, relay range 66-110 Amps CT operated.
202Supply and fixing in replacement PVC insulated multistranded copper conductor wire of following size 6 sqmm, single core, 1100 volts complete all as specified and as directed.
203All same as item No 202.00 above but size 10 sqmm
204All same as item No 202.00 above but size 16 sqmm
205S&F in replacement of3 Pole MCCB,250 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified and directed
206S&F in replacement of 3 Pole MCCB,400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed
207S&F in replacement of 3 Pole MCCB,630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA complete all as specified and directed.
208S&F in replacement of4 Pole MCCB,250 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified and directed.
209S&F in replacement of4 Pole MCCB,400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed.
210Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron wire 4mm dia by means of Copper nuts, bolts and washers. GI wire laid in 20mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a)GI wire 4 mm dia (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
211Material and Labour for earthing complete with copper plate electrode 600mmx600mmx3.15mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.Copper plate connected with copper earth strip 20x3mm by means ofnuts, bolts and washers.Copper striplaid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) as shown in electrical plat No. 03 of SSR Part-I with following:- (a)Copper strip 20x3mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothlyfinished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-inforced with 8mm dia bars 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
212M&L for copper strip 20mmx3mm buried in ground including necessary excavation & earth work in soft/loose soil and removal of excavated material to a distance n.exc 50 mtrs and deposited where directed including taking out old unserviceablecomplette all as specified & directed.
213Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50Sqmm 3.5 core including suitable size Aluminium lugs properly crimpled with crimping tools including testing complete all as specified and directed
214Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70Sqmm 3.5 core including suitable size Aluminium lugs properly crimpled with crimping tools including testing complete all as specified and directed
215Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95Sqmm 3.5 core including suitable size Aluminium lugs properly crimpled with crimping tools including testing complete all as specified and directed
216Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and as directed. Note : Punned thickness shall be measured.
217Supply and laying in trenches burnt brick sub class "B" standard size for cable protection keeping width of the brick parallel to the length of the cable all as specified and directed.
218S&F in repair3 phase sequencer complete all as specified and directed.
219Supplying and laying in replacement of CPVC pipes of outer dia 16 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
220Supplying and laying in replacement of CPVC pipes of outer dia 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed..
221Supplying and laying in replacement of Unplasticised PVC pipes of dia 15 mm of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed.
222Supplying and laying in replacement of Unplasticised PVC pipes of dia 20 mm of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed.
223Supplying and laying in replacement of Unplasticised PVC pipes of dia 25 mm of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed.
224Supplying and laying in replacement of Unplasticised PVC pipes of dia 40 mm of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed.
225Supplying and laying in replacement of Unplasticised PVC pipes of dia 50 mm of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed.
226Supply and fixin replacement of CPVC Ball Valves, with brass threaded (two sided) , 16 mm (1/2”)dia.
227Supply and fixin replacement of CPVC Ball Valves, with brass threaded (two sided) , 20 mm (3/4”)dia.
228S&Fin replacement of UPVC Ball Valves, of size 16 mm (1/2”)dia, complete all as specified and directed
229Supply and fixin replacement of UPVC Ball Valves, of size 20 mm (3/4”)dia, complete all as specified and directed.
230Supply and fixin replacement of UPVC Ball Valves, of size 25 mm (1”)dia, complete all as specified and directed
231Supply and fixin replacement of UPVC Ball Valves, of size40 mm (3/2”)dia, complete all as specified and directed.
232Supply and fixin replacement of UPVC Ball Valves, of size50 mm (2”)dia, complete all as specified and directed.
233M & L for digital printing in any font on night glow acrylic sheet 3mm thick in any size of board for data of Installations/plants/line diagram/signboard fixed on board of suitable size including fixing on wall with suitable screws, nails complete all as specified and directed.
234Material and labour for writing letters or figures (block, Roman, Italic or Indian) n.exc 30cm high with thick paint so that they stand out boldly & solidly without showing signs of brush marks complete all as specified and as directed.
235M & L for preparation of old decorated wall surfaces by complete remowal of existing treatment and applying two coats of cement base paints, white or tinted (colour and shade as per new colour scheme approved by GE over a coat of primer of same make including scaffolding for two story building complete all as specified and directed.
236M & L for praparation by complete removal of existing treatment, washing down and stopping of distempered and painted surfaces and old plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care putty complete all as specified and directed.
237M & L for applying two coat of white wash on ceiling of old surfaces including preparation of ceiling surfaces.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail